Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Stacja Uzdatniania Wody" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
The use of the biological method for treating iron containing underground waters
Wykorzystanie metody biologicznej do oczyszczania wód podziemnych zawierających żelazo
Autorzy:
Kvartenko, O.
Sabliy, L.
Kovalchuk, N.
Lysytsya, A.
Powiązania:
https://bibliotekanauki.pl/articles/293309.pdf
Data publikacji:
2018
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
biological method
iron bacteria
treatment stations
underground water
bakterie żelazowe
metoda biologiczna
stacja uzdatniania wody
wody podziemne
Opis:
The use of the biological method is promising for treating underground waters from iron compounds. Iron bacteria used in the process are widely spread in weak acidic and neutral underground waters containing iron ions (II), dissolved carbon dioxide and minimum concentrations of oxygen. The relevant direction of present-day biotechnology is the use of iron bacteria for treating underground waters. The goal of this research is to compare the efficiency of using the biological method for treating underground iron containing weak acidic and neutral waters under different conditions. As the testobjects, Gallionella and Lepthotrix iron bacteria were used. The sedimentation of bio-minerals was obtained from the washout waters of the biological deironing station. Calcium soda was used as an additional source of inorganic carbon for bacteria. As a result of the studies it is established that the use of the non-reagent method gives the possibility to achieve only 80% efficiency in removing iron compounds while the use of sodium carbonate results in increasing efficiency up to 93%. To determine the contribution of biological purification of ground water from iron compounds, the bacteria were inhibited with the preparation of polyhexamethylene guanidine (PHMG) chloride. It was found that inhibition of Gallionella and Lepthotrix led to the reduction of 50% of the iron removal effect. The mechanism was developed of inhibiting the process of iron bacteria metabolism by PHMG (polyhexamethylene guanidine). The new technology of arranging a blockmodule station for treating underground waters is proposed.
Metoda biologiczna stwarza obiecującą możliwość oczyszczania wód podziemnych ze związków żelaza. Bakterie żelazowe używane w tym procesie są szeroko rozpowszechnione w słabo kwaśnych i obojętnych wodach podziemnych zawierających jony żelaza (II), rozpuszczony ditlenek węgla i minimalne stężenie tlenu. Współczesne kierunki w biotechnologii zmierzają do użytkowania bakterii żelazowych w procesie uzdatniania wód podziemnych. Celem przedstawionych badań było porównanie w różnych warunkach wydajności metody biologicznej stosowanej do uzdatniania słabo kwaśnych i obojętnych wód podziemnych zawierających żelazo. Obiektem badań były bakterie żelazowe Gallionella i Lepthotrix. Biominerały sedymentowały z wód płuczących pochodzących ze stacji odżelaziania wody. Jako dodatkowe źródło nieorganicznego węgla dla bakterii użyto węglan sodu. W wyniku przeprowadzonych badań ustalono, że wykorzystanie metody bez dodatku odczynnika umożliwia osiągnięcie 80-procentowej wydajności usuwania związków żelaza; dodanie węglanu sodu zwiększa tę wydajność do 93%. W celu określenia udziału biologicznego oczyszczania wód gruntowych ze związków żelaza zahamowano aktywność bakterii za pomocą chlorowodorku poliheksametylenoguanidyny (PHMG). Stwierdzono, że zahamowanie aktywności Gallionella i Lepthotrix zredukowało efekt usuwania żelaza o 50%. Opracowano mechanizm hamowania metabolizmu bakterii przez PHMG. Zaproponowano nową technologię blokowo-modułową dla stacji uzdatniania wód podziemnych.
Źródło:
Journal of Water and Land Development; 2018, 39; 77-82
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the properties and particle size distribution of spent filter backwash water from groundwater treatment at various stages of filters washing
Badania właściwości i rozkładów wielkości cząstek zawiesin w popłuczynach w różnych czasach trwania cykli filtracji
Autorzy:
Wiercik, P.
Matras, K.
Burszta-Adamiak, E.
Kuśnierz, M.
Powiązania:
https://bibliotekanauki.pl/articles/296715.pdf
Data publikacji:
2016
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
water treatment plant
spent filter backwash water
laser granulometer
laser diffraction
groundwater
stacja uzdatniania wody
popłuczyny
granulometr laserowy
dyfrakcja laserowa
wody podziemne
Opis:
In Poland, water supply for villages and small towns is provided mainly from groundwater resources. In spite of good physicochemical and bacteriological properties for groundwater, in most cases it is required to remove iron and manganese, which influences the applied treatment technologies. The processes of potable water treatment result in the emergence of certain by-products, i.e. technological wastewater (mainly spent filter backwash water) and sediments that contain the pollutants removed from water. The study presents the results of the Authors’ tests of particle size and quantity distribution in spent filter backwash water from the groundwater treatment plant in Kąty Wrocławskie. The paper also contains an analysis of the changeability of iron and manganese content and turbidity in different phases of filter backwashing (initial backwashing, air backwashing, second backwashing). The research consisted of four series of tests conducted during the period from July 2013 to May 2014. Spent filter backwash water samples were collected during backwashing of two filters. Test results have shown that the quality of spent filter backwash water changed on subsequent stages of backwashing. Suspension particles of a size ranging from 10÷20 μm accounted for the highest volume percentage share in the analysed samples of spent filter backwash water from both filters, while the quantitative distribution of particles of the given diameters was heterogeneous and it depended on the stage of filter backwashing.
W Polsce w celu zaopatrzenia w wodę wsi i małych miasteczek ujmowane są przede wszystkim zasoby wód podziemnych. Pomimo dobrych właściwości fizyczno-chemicznych i bakteriologicznych wykazywanych przez wody podziemne większość z nich wymaga odżelaziania i odmanganiania, co ma wpływ na technologie ich uzdatniania. Podczas procesów uzdatniania wody przeznaczonej do spożycia przez ludzi powstają produkty uboczne, tj. ścieki technologiczne (głównie popłuczyny) oraz osady, w których zawarte są zanieczyszczenia usuwane z wody. W pracy przedstawiono wyniki własnych badań rozkładów wielkości i ilości cząstek zawiesin w popłuczynach ze stacji uzdatniania wód podziemnych w Kątach Wrocławskich. W artykule przeanalizowano również zmienność zawartości żelaza, manganu oraz mętności w różnych fazach płukania filtrów (płukanie wstępne wodą, płukanie powietrzem, płukanie właściwe wodą). Badania obejmowały cztery serie badawcze w okresie od lipca 2013 roku do maja 2014 roku. Próbki popłuczyn były pobierane podczas płukania dwóch filtrów. Wyniki badań wykazały, że jakość popłuczyn ulegała zmianie w kolejnych etapach płukania. Największy udział procentowy cząstek w badanych próbkach popłuczyn z płukania obydwu filtrów w ujęciu objętościowym stanowiły cząstki zawiesin o wielkościach z zakresu 10÷20 μm. Natomiast rozkład ilościowy cząstek o danych średnicach był niejednorodny i zależał od etapu płukania filtrów.
Źródło:
Inżynieria i Ochrona Środowiska; 2016, 19, 1; 149-161
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modernizacja stacji uzdatniania wód podziemnych "Letniki" koło Elbląga
Retrofit of the Letniki groundwater treatment plant near Elbląg
Autorzy:
Olańczuk-Neyman, K.
Bray, R.
Powiązania:
https://bibliotekanauki.pl/articles/237730.pdf
Data publikacji:
2001
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
wody podziemne
stacja uzdatniania wód
jakość wód
prace modernizacyjne
Opis:
The object under study was retrofitted in the late 1990s with the aim to upgrade the quality of the water sent to the distribution system in general, and the removal efficiency for iron, manganese and ammonia nitrogen in particular. The taken-in water, which comes predominantly from the Quaternary aquifer, is classified as "hard water" because of the high concentrations of iron, manganese and ammonium nitrogen (5.0 gFe/m[3], 1.5 gMn/m[3] and 2.0 gN/m[3]). The water treatment train made use of prior to the retrofit (which included aeration and single-stage filtration) yielded only iron removal to the level of about 0.3 gFe/m[3]; the concentrations of the other investigated compounds still exceeded considerably the admissible values, as they ranged from 0.5 to 1.0 gMn/m[3] and from 0.9 to 2.0 gN/m[3]. Following analysis of the pilot-plant results, an additional filtration stage, which involved a mature high-silica sand bed, was proposed. The retrofit of the treatment plant brought about a noticeable improvement of water quality. The concentrations of iron, manganese and ammonia nitrogen in the treated water amounted to 0.2 gFe/m[3], 0.05 gMn/m[3] and 0.2 gN/m[3], respectively. However owing to the incomplete separation of the tanks and to the distribution of mixed water (after the first and second stage of filtration), the concentration of manganese in the tap water slightly exceeds the admissible values.
Źródło:
Ochrona Środowiska; 2001, 3; 21-24
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies