Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "water treatment process" wg kryterium: Temat


Wyświetlanie 1-8 z 8
Tytuł:
The Use of Biofiltration Process to Remove Organic Matter From Groundwater
Autorzy:
Papciak, D.
Kaleta, J.
Puszkarewicz, A.
Tchórzewska-Cieślak, B.
Powiązania:
https://bibliotekanauki.pl/articles/952351.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
groundwater
biofiltration process
total organic carbon (TOC)
water treatment
Opis:
The article describes the research on the removal of organic matter from natural underground water using biofiltration process. The study was carried out in semi-technical scale on a model filter composed of activated carbon WD-extra. The development of biological activity in a biosorption bed, as well as observations on the relationship between the processes of sorption and biodegradation was evaluated based on the Eberhardt, Madsen, Sontheimer (EMS) test. Leading operation control parameters of biologically active carbon filter BAF included: change of TOC content, dissolved oxygen and permanganate index. To evaluate the colonization of granular carbon determination of ATP value was used. The presence of the biofilm was found by observation using light and scanning microscopes. The organic compounds in the water taken were adsorbed 100% and 70% biodegradable. The combination of sorption process with biodegradation until depletion of activated carbon adsorption capacity allowed in the initial phase of coalbed work for the removal of organic matter in approx. 100%. Formation of biofilm at the right time allowed to extend the filtration cycle and helped lower the TOC by 70%, i.e. from 10 mg C/l to 3–4 mg C/l.
Źródło:
Journal of Ecological Engineering; 2016, 17, 3; 119-124
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Założenia technologiczne systemu sterowania procesami koagulacji i flotacji ciśnieniowej w układzie oczyszczania wody
Technological assumptions of coagulation and dissolved air flotation control system in water treatment process
Autorzy:
Kłos, M.
Powiązania:
https://bibliotekanauki.pl/articles/237854.pdf
Data publikacji:
2013
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
water treatment
turbidity
water quality
process control
oczyszczanie wody
mętność
absorbancja w nadfiolecie
sterowanie
Opis:
Based on technical and laboratory scale study results, design recommendations for coagulation and dissolved air flotation control system in water treatment train with high quality variability were presented. Hydrolyzing coagulants, when applied, were demonstrated to require fluent rotational stirrer speed regulation in flocculators. This allows maintenance of adequate floc size which determines bubble-floc agglomerate formation efficacy and their resistance to mechanical tension in the contact zone of flotation tank. In practice, real time rotation regulation in flocculators might be applied, depending on water turbidity or particle number in water fraction leaving flotation tank. Required recirculation factor might be estimated in real time, based on the clarified water quality. However, this solution is very difficult to implement due to many factors that affect efficiency of coagulation and dissolved air flotation processes. It was demonstrated that special attention should be paid to differentiation between the effect of inadequate coagulant dose and the improper recirculation factor. Use of information on the amount and type of suspensions in the intake water, obtained based on UV-absorbance and turbidity measurements, appears to be a better approach.
Na podstawie wyników badań wykonanych w skali laboratoryjnej i technicznej przedstawiono zalecania do projektowania systemu sterowania koagulacją i flotacją ciśnieniową w układzie oczyszczania wody o dużej zmienności jakościowej. Wykazano, że w przypadku stosowania koagulantów hydrolizujących konieczne jest zastosowanie płynnej regulacji prędkości obrotowej mieszadeł w komorach flokulacji. Pozwala to na utrzymanie odpowiedniej wielkości kłaczków, od czego zależy skuteczność powstawania aglomeratów flotacyjnych oraz ich wytrzymałość na naprężenia mechaniczne występujące w strefie kontaktu komory flotacji. W praktyce możliwe jest zastosowanie regulacji obrotów w komorach flokulacji w czasie rzeczywistym w zależności od mętności wody lub liczby cząstek w wodzie opuszczającej komorę flotacji. Wartość wymaganego stopnia recyrkulacji może być określana w czasie rzeczywistym w oparciu o jakość wody sklarowanej. Jednak jest to rozwiązanie bardzo trudne w realizacji z uwagi na to, że na sprawność działania procesów koagulacji i flotacji ciśnieniowej wpływa zbyt wiele czynników. Wykazano, że szczególną uwagę należy zwrócić na rozgraniczenie wpływu nieodpowiedniej dawki koagulantu oraz niewłaściwego stopnia recyrkulacji. Wydaje się, że lepszym rozwiązaniem jest wykorzystanie informacji o ilości i rodzaju zawiesin obecnych w ujmowanej wodzie, uzyskanych na drodze pomiaru absorbancji w nadfiolecie i mętności.
Źródło:
Ochrona Środowiska; 2013, 35, 3; 39-43
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usuwanie mykoestrogenów z roztworów wodnych w zintegrowanym procesie fotokataliza-mikrofiltracja-nanofiltracja
Removal of mycoestrogens from aqueous solutions in the integrated photocatalysis-microfiltration-nanofiltration process
Autorzy:
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/236700.pdf
Data publikacji:
2012
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie wody
mykoestrogeny
proces zintegrowany
fotokataliza
nanofiltracja
water treatment
mycoestrogens
integrated process
photocatalysis
nanofiltration
Opis:
Wykazano dużą skuteczność (>90%) usuwania zanieczyszczeń, w tym małocząsteczkowych mykoestrogenów (zearalenon i [alfa]-zearalenol w ilości 500 mg/m3) w zintegrowanym procesie oczyszczania wody fotokataliza-mikrofiltracja-nanofiltracja. Skuteczność usuwania mykoestrogenów w tym procesie była znacznie większa niż w samym procesie fotokatalizy. Porównując skuteczność samej nanofiltracji ze skutecznością procesu zintegrowanego stwierdzono, że usunięcie mykoestrogenów w obu przypadkach było zbliżone, jednakże realizacja nanofiltracji w procesie zintegrowanym była korzystniejsza pod względem wydajności hydraulicznej membrany. Rozpatrując skuteczność i wydajność nanofiltracji w procesie zintegrowanym wykazano większą przydatność membran wykonanych z octanu celulozy (CK) niż membran kompozytowych (DK) o poliamidowej warstwie naskórkowej, które były bardziej podatne na blokowanie. Wprowadzenie do układu oczyszczania wody fotokatalizy przed nanofiltracją w zasadniczy sposób ograniczyło występowanie zjawiska blokowania membran. Należy wziąć jednak pod uwagę niebezpieczeństwo pojawienia się w wodzie związków organicznych o mniejszej masie cząsteczkowej niż występujące w wodzie modelowej, co może zmniejszyć skuteczność procesu oczyszczania.
The efficiency of pollutant removal obtained with the integrated photo-catalysis-microfiltration-nanofiltration process exceeded 90%, which includes the removal of low-molecular-weight mycoestrogens (zearalenone and [alfa]-zearalenole, at concentrations of 500 mg/m3). The extent of mycoestrogen removal was significantly higher in the integrated process than in photocatalysis alone. Comparisons have shown that nanofiltration alone produced removal of mycoestrogens similar to that obtained in the integrated process, but when nanofiltration was integrated with photocatalysis and microfiltration, the hydraulic capacity of the membrane was more advantageous. Analysis of the efficiency and capacity of nanofiltration in the integrated process substantiated the advantage of cellullose acetate membranes over composite membranes with polyamide skin, which display greater proneness to clogging. When in the integrated system photocatalysis preceded nanofiltration, the occurrence of membrane clogging was noticeably reduced. Yet, there is still a real risk that surface water may contain organic compounds with lower molecular weight as compared to those present in model solutions, and this may cause the removal efficiency of the treatment process to decline.
Źródło:
Ochrona Środowiska; 2012, 34, 1; 29-32
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usuwanie arsenu z wody podziemnej w zintegrowanym procesie koagulacja/mikrofiltracja
Arsenic removal in integrated coagulation/microfiltration process
Autorzy:
Bray, R. T.
Powiązania:
https://bibliotekanauki.pl/articles/237341.pdf
Data publikacji:
2013
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie wody
pierwiastek śladowy
proces membranowy
membrany rurowe
water treatment
trace element
membrane process
tubular membranes
Opis:
Przedstawiono wyniki badań przeprowadzonych w skali ułamkowo-technicznej nad zastosowaniem procesu koagulacji zintegrowanej z mikrofiltracją do usuwania arsenu z wody podziemnej zawierającej 40 mgAs/m3, 0,7 gFe/m3 oraz 0,1 gMn/m3. Jako koagulant zastosowano wodny roztwór siarczanu żelaza(III) – PIX 112 w dawkach 0,5÷19gFe/m3. W badaniach wykorzystano rurowe membrany mikrofiltracyjne z PVDF o granicznej rozdzielczości (cut off) 400 kDa. Zastosowano przepływ jednokierunkowy (dead-end) przy ciśnieniu transmembranowym 0,1÷0,2 MPa. Wykazano, że już przy dawce koagulantu około 2,0 gFe/m3 uzyskano usunięcie arsenu do wartości mniejszej niż dopuszczalna w wodzie przeznaczonej do spożycia (10 mgAs/m3), a współczynnik retencji arsenu przekraczał 76 %. Dalsze zwiększanie dawki koagulantu skutkowało tylko niewielkim zmniejszeniem zawartości arsenu w wodzie oczyszczonej. Zawartość związków żelaza w permeacie, w całym zakresie zastosowanych dawek, była śladowa. Usuwaniu arsenu towarzyszyło zmniejszenie intensywności barwy wody, absorbancji w nadfiolecie oraz utlenialności. Badany proces był natomiast nieskuteczny w usuwaniu związków manganu z wody podziemnej.
Pilot plant results of studies on arsenic removal from groundwater that contained 40 mgAs/m3, 0.7 gFe/m3, and 0.1 gMn/m3, using integrated coagulation/microfiltration process were presented. Iron sulfate(III) (PIX 112) water solution was used as coagulant in doses ranging from 0.5 to 19 gFe/m3. For the experimental purposes PVDF tubular microfiltration membrane with cut-off of 400 kDa was used. One direction (dead-end) flow was applied with pressure ranging from 0.1 to 0.2 MPa. It was demonstrated that at coagulant dose of 2.0 gFe/m3 arsenic was brought down to below target value (<10 mgAs/m3), accepted for human consumption, while the retention coefficient exceeded 76%. Further increase in the coagulant dose led to only insignificant reduction in arsenic content in the purified water. In the dose range applied, there was only a trace amount of iron in the permeate. Arsenic removal was accompanied by reduction in water color intensity, UV-absorbance and chemical oxygen demand (COD). The process, however, was not effective for groundwater manganese removal.
Źródło:
Ochrona Środowiska; 2013, 35, 4; 33-37
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usuwanie zanieczyszczeń z wód w hybrydowym reaktorze membranowym przy współudziale procesu MIEX®DOC
Removal of contaminants from water in hybrid membrane reactor in cooperation MIEX®DOC process
Autorzy:
Rajca, M.
Powiązania:
https://bibliotekanauki.pl/articles/127542.pdf
Data publikacji:
2013
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
proces MIEX DOC
ultrafiltracja
reaktor membranowy
oczyszczanie wód
MIEX DOC process
ultrafiltration
membrane reactor
water treatment
Opis:
Celem pracy było określenie efektywności usuwania zanieczyszczeń organicznych i nieorganicznych z wody w hybrydowym reaktorze membranowym, w którym realizowano proces wymiany jonowej i ultrafiltracji. W badaniach wykorzystano żywicę MIEX® firmy Orica Watercare oraz ultrafiltracyjny moduł kapilarny zanurzeniowy ZeeWeed 1 (ZW 1), pracujący w podciśnieniu, wykonany z polifluorku winylidenu, firmy GE Power&Water. Zastosowanie wielofunkcyjnego reaktora korzystnie wpływało na efektywność usuwania zanieczyszczeń, uzyskując wodę oczyszczoną wysokiej jakości, a w odniesieniu do procesu ultrafiltracji zminimalizowano problem foulingu membrany.
The aim of this study was to determine the effectiveness of removal of organic and inorganic contaminants from water using hybrid membrane reactor in which ion exchange and ultrafiltration processes were performed. MIEX® resin by Orica Watercare and immersed ultrafiltration polyvinylidene fluoride capillary module ZeeWeed 1 (ZW 1) by GE Power&Water operated at negative pressure were used. The application of multifunctional reactor had a positive effect on the removal of contaminants and enabled the production of high quality water. Additionally, in refer to single stage ultrafiltration it minimalized the occurrence of membrane fouling.
Źródło:
Proceedings of ECOpole; 2013, 7, 1; 393-398
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of the most effective operating conditions of membrane bioreactor used to industrial wastewater treatment
Autorzy:
Świerczyńska, A.
Bohdziewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/208164.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
wastewater treatment
activated sludge process
bioconversion
bioreactors
industrial water treatment
landfill
leachate treatment
water treatment
activated sludge
dairy wastewater
industrial wastewater treatment
membrane bioreactor
municipal landfills
oczyszczalnia ścieków
proces osadu czynnego
biokonwersja
bioreaktory
uzdatnianie wody przemysłowej
uzdatnianie wody
osad czynny
ścieki mleczarskie
oczyszczanie ścieków przemysłowych
bioreaktor membranowy
składowiska odpadów komunalnych
Opis:
The effectiveness of co-treatment of leachates from an old site of municipal landfill with a dairy industry wastewater in a membrane bioreactor has been investigated. The subjects of the study were leachates collected at the municipal landfill in Tychy and dairy wastewaters from Dairy Plant in Bieruń. The determination of the most effective technological parameters of the process, i.e. activated sludge load and its concentration and types of COD fractions in the reactor influent was made. It was shown that the activated sludge load at the level of 0.06 g COD/(gDM·d) was the highest permissible one among all the investigated loads and the process run effectively within the whole investigated range of concentrations of activated sludge in a bioreactor. It was found that in the treated wastewater, the fraction of easily degradable organic compounds was the dominant one.
Źródło:
Environment Protection Engineering; 2015, 41, 1; 41-51
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Post-coagulation sludge as an adsorbent of dyes from aqueous solutions
Osad pokoagulacyjny jako adsorbent barwników z roztworów wodnych
Autorzy:
Pieczykolan, B.
Płonka, I.
Powiązania:
https://bibliotekanauki.pl/articles/127092.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
water treatment
coagulation
post-coagulation sludge
dyes
waste sorbent
sorption process
sorption isotherm
uzdatnianie wody
koagulacja
osad pokoagulacyjny
barwnik
proces sorpcji
sorbenty odpadowe
izoterma sorpcji
Opis:
Water taken from the environment, before it is directed to recipients as drinking water, must be purified via different processes. From the water, inter alia, suspensions, organic compounds, colloidal particles as well as bacteria and viruses must be removed. The main source of usable water supply is surface water. The most frequently used methods of surface water treatment are coagulation and filtration processes. During these processes post-coagulation sludge is generated, which is the main waste produced in water treatment plants. This sludge is characterized by an amorphous structure with a strongly developed specific surface, similar to sewage sludge. In addition, it has a high content of organic compounds. In recent years, attempts have been made to transform sewage sludge from municipal wastewater treatment plants into waste sorbents. Taking into account some similarity between sewage sludge and post-coagulation sludge, an attempt was made to apply post-coagulation sludge as sorbent of dyes from aqueous solutions. Dried and crushed post-coagulation sludge was used in the studies. The most favourable pH of process and contact time as well as sorption isotherm were established. Moreover, based on the different isotherm two-parameter models, the sorption capacity, type of sorption and energy of sorption were calculated.
Woda pitna, zanim zostanie skierowana do odbiorców, musi zostać poddana procesom oczyszczania. Z wody muszą zostać usunięte między innymi zawiesiny, substancja organiczna, cząstki koloidalne oraz bakterie i wirusy. Głównym źródłem zaopatrywania w wodę użytkową są wody powierzchniowe. Najczęściej stosowanymi metodami uzdatniania wody powierzchniowej są metody koagulacji i filtracji. W trakcie tych procesów powstają osady pokoagulacyjne, które są głównymi odpadami powstającymi w zakładach uzdatniania wody. Osady te charakteryzują się strukturą amorficzną o mocno rozbudowanej powierzchni właściwej, podobnie jak osady ściekowe. Ponadto posiadają dużą zawartość związków organicznych. W ostatnich latach podjęto próby przeróbki osadów ściekowych pochodzących z komunalnych oczyszczalni ścieków w celu uzyskania odpadowych sorbentów. Uwzględniając pewne podobieństwo pomiędzy osadami ściekowymi, jak również pokoagulacyjnymi podjęto próbę wykorzystania osadów pokoagulacyjnych jako sorbentów barwników z roztworów wodnych. W trakcie badań wykorzystano wysuszone i rozdrobnione osady pokoagulacyjne. Wyznaczono najkorzystniejsze parametry procesu sorpcji statycznej (pH i czas kontaktu), jak również izotermę adsorpcji. Ponadto wykorzystując różne modele dwuparametryczne, wyznaczono maksymalną pojemność sorpcyjną, typ adsorpcji oraz energię adsorpcji.
Źródło:
Proceedings of ECOpole; 2018, 12, 2; 315-323
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Removal of pesticides and inorganic pollutants by reverse osmosis
Autorzy:
Šír, M.
Podhola, M.
Patočka, T.
Honzajková, Z.
Kocurek, P.
Bystrianský, M.
Vurm, R.
Kubal, M.
Powiązania:
https://bibliotekanauki.pl/articles/207770.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
groundwater
groundwater pollution
pesticides
reverse osmosis
water treatment
batch process
chlorinated pesticides
inorganic pollutants
polyamide membranes
wody gruntowe
zanieczyszczenie wód gruntowych
pestycydy
odwrócona osmoza
uzdatnianie wody
proces wsadowy
chlorowane pestycydy
zanieczyszczenia nieorganiczne
membrany poliamidowe
Opis:
Contamination of soil and groundwater with pesticides is mainly caused by old ecological burdens. This study focuses on the treatment of groundwater contaminated with chlorinated pesticides. The contaminants mainly include α-HCH, β-HCH, γ-HCH, HCB, DDE, DDD and DDT. Reverse osmosis technology using RO98pHt polyamide membranes was used to remove the pollutants under batch process conditions. The observed rate of removal ranged from 98.4% to 99.7%. Total dissolved content solids decreased from 1.35 g/dm3 to below 0.05 g/dm3.
Źródło:
Environment Protection Engineering; 2015, 41, 2; 159-166
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies