Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "treatment process" wg kryterium: Wszystkie pola


Tytuł:
Studies on the Efficiency of Grundwater Treatment Process With Adsorption on Activated Alumina
Autorzy:
Szatyłowicz, E.
Skoczko, I.
Powiązania:
https://bibliotekanauki.pl/articles/123695.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
activated alumina
water treatment
adsorption
popular pollutants
Opis:
One of inorganic sorbents used in water treatment technology is activated alumina. It is recommended by the European Commission to remove inorganic impurities, such as arsenic, fluoride, selenium and silicates. The adsorbent is usually applied in a granular form, under flow conditions. It can become absorbent material, increasingly used due to the presence of arsenic beside iron and manganese in groundwater intakes. The aim of the study was to evaluate the effectiveness of groundwater treatment in the technological system containing adsorption on activated alumina. The experiment was performed on test model CE 581 manufactured by G.U.N.T. Hamburg, in which four treatment stages can be extracted. The first stage is used in a gravel filter of grain size 1–2 mm, in the second sand filter of grain size 0.4–0.8 mm. The third and fourth phase includes two adsorbers. The first adsorber comprises activated alumina (Al,sub>2O3) and the other comprises a granular activated carbon. The study was conducted at different speeds of filtration: 5, 10 and 15 m/h. In the raw water samples and the purified water samples after each treatment step the following parameters were determined: pH, O,sub>2 concentration, electrolytic conductivity, SO42-, concentration, NO3- concentration, PO43- concentration, Cl- concentration, color, turbidity, iron and manganese concentration, CODMn, total hardness, calcium hardness, magnesium hardness, content of dissolved substances. The conducted research indicates that optimum filtration rate for most pollution is 15 m/h. Moreover, the presence of activated alumina has contributed to increasing the efficiency of nitrate (V) and phosphate (V) ions removal.
Źródło:
Journal of Ecological Engineering; 2017, 18, 4; 211-218
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody oceny stopnia zużycia węgla aktywnego w procesie oczyszczania wody
Estimating the extent of depletion of active carbon in water treatment process
Autorzy:
Świątkowski, A.
Biniak, S.
Pakuła, M.
Trykowski, G.
Powiązania:
https://bibliotekanauki.pl/articles/236802.pdf
Data publikacji:
2005
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie wody
węgiel aktywny
zużynie węgla
zdolność sorpcyjna
active carbon
depletion
water treatment
sorption capacity
Opis:
Przeprowadzono porównawcze badania nad oceną przydatności metod określania stopnia zużycia węgla aktywnego stosowanego do oczyszczania wody. Do tego celu wykorzystano próbki formowanego węgla aktywnego pochodzące ze złóż filtracyjnych, przez które przepłynęły trzy różne objętości wody. Dla każdej próbki węgla wyznaczono powierzchnię właściwą BET na podstawie niskotemperaturowej adsorpcji azotu, liczbę jodową, zawartość popiołu oraz ubytek masy podczas termograwimetrycznego ogrzewania w zakresie temperatur od 150 oC do 600 oC. Dla każdej próbki węgla zarejestrowano także cykliczne krzywe woltamperometryczne, używając techniki proszkowych elektrod węglowych i jonów żelaza(III) w roztworze kwasowym jako depolaryzatora. Wszystkie wyniki skorelowano z objętościowym przepływem wody przez złoża węgla aktywnego. Analizowano przydatność każdej metody do oceny stopnia zużycia węgla aktywnego w procesie oczyszczania wody.
Comparative studies were carried out to assess the usefulness of the available methods for estimating the extent of depletion of the active carbon used in the water treatment process. For this purpose, we made use of extruded active carbon samples from filter beds after passage of three different quantities of water. The specific BET surface area was determined for each sample on the basis of low-temperature nitrogen adsorption, iodine number, ash content, and loss of mass during thermogravimetric heating from 150 oC to 600 oC. Also for each sample the cyclic voltammetric curve was recorded by the powdered carbon electrode technique, using Fe(III) ions in acidic solution as depolarizers. The results were correlated with the volumetric water flow through the active carbon filters. The benefits offered by each method when estimating the extent of depletion of the active carbon in the course of the water treatment process were analyzed.
Źródło:
Ochrona Środowiska; 2005, R. 27, nr 1, 1; 3-6
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Założenia technologiczne systemu sterowania procesami koagulacji i flotacji ciśnieniowej w układzie oczyszczania wody
Technological assumptions of coagulation and dissolved air flotation control system in water treatment process
Autorzy:
Kłos, M.
Powiązania:
https://bibliotekanauki.pl/articles/237854.pdf
Data publikacji:
2013
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
water treatment
turbidity
water quality
process control
oczyszczanie wody
mętność
absorbancja w nadfiolecie
sterowanie
Opis:
Based on technical and laboratory scale study results, design recommendations for coagulation and dissolved air flotation control system in water treatment train with high quality variability were presented. Hydrolyzing coagulants, when applied, were demonstrated to require fluent rotational stirrer speed regulation in flocculators. This allows maintenance of adequate floc size which determines bubble-floc agglomerate formation efficacy and their resistance to mechanical tension in the contact zone of flotation tank. In practice, real time rotation regulation in flocculators might be applied, depending on water turbidity or particle number in water fraction leaving flotation tank. Required recirculation factor might be estimated in real time, based on the clarified water quality. However, this solution is very difficult to implement due to many factors that affect efficiency of coagulation and dissolved air flotation processes. It was demonstrated that special attention should be paid to differentiation between the effect of inadequate coagulant dose and the improper recirculation factor. Use of information on the amount and type of suspensions in the intake water, obtained based on UV-absorbance and turbidity measurements, appears to be a better approach.
Na podstawie wyników badań wykonanych w skali laboratoryjnej i technicznej przedstawiono zalecania do projektowania systemu sterowania koagulacją i flotacją ciśnieniową w układzie oczyszczania wody o dużej zmienności jakościowej. Wykazano, że w przypadku stosowania koagulantów hydrolizujących konieczne jest zastosowanie płynnej regulacji prędkości obrotowej mieszadeł w komorach flokulacji. Pozwala to na utrzymanie odpowiedniej wielkości kłaczków, od czego zależy skuteczność powstawania aglomeratów flotacyjnych oraz ich wytrzymałość na naprężenia mechaniczne występujące w strefie kontaktu komory flotacji. W praktyce możliwe jest zastosowanie regulacji obrotów w komorach flokulacji w czasie rzeczywistym w zależności od mętności wody lub liczby cząstek w wodzie opuszczającej komorę flotacji. Wartość wymaganego stopnia recyrkulacji może być określana w czasie rzeczywistym w oparciu o jakość wody sklarowanej. Jednak jest to rozwiązanie bardzo trudne w realizacji z uwagi na to, że na sprawność działania procesów koagulacji i flotacji ciśnieniowej wpływa zbyt wiele czynników. Wykazano, że szczególną uwagę należy zwrócić na rozgraniczenie wpływu nieodpowiedniej dawki koagulantu oraz niewłaściwego stopnia recyrkulacji. Wydaje się, że lepszym rozwiązaniem jest wykorzystanie informacji o ilości i rodzaju zawiesin obecnych w ujmowanej wodzie, uzyskanych na drodze pomiaru absorbancji w nadfiolecie i mętności.
Źródło:
Ochrona Środowiska; 2013, 35, 3; 39-43
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie testów naczyniowych do oceny skuteczności usuwania substancji organicznych z wody w procesie MIEX®DOC
Application of jar tests to estimating the efficiency of organic substances removal in the MIEX®DOC water treatment process
Autorzy:
Mołczan, M.
Biłyk, A.
Slunjski, M.
Celer, K.
Powiązania:
https://bibliotekanauki.pl/articles/236804.pdf
Data publikacji:
2005
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie wody
substancje organiczne
żywica MIEX
wymiana jonowa
water treatment
organics removal
MIEX® resin
ion exchange
Opis:
Usunięcie związków organicznych do jak niższego poziomu z wody przeznaczonej do spożycia staje się coraz pilniejszym zadaniem technologicznym, głównie z uwagi na tworzenie ubocznych produktów dezynfekcji. Obok klasycznych procesów jednostkowych oczyszczania wody, bardzo obiecująca jest nowa technologia MIEX®DOC, zaproponowana przez firmę Orica Watercare, polegająca na zastosowaniu namagnetyzowanych żywic anionowymiennych do usuwania substancji organicznych z wody. W pracy przedstawiono wyniki standardowych testów oczyszczania wody, tj. kinetycznego, symulacyjnego oraz koagulacji, na przykładzie wody powierzchniowej (Oława), ujmowanej na potrzeby Zakładu Produkcji Wody "Mokry Dwór" we Wrocławiu. Uzyskane wyniki pozwoliły na wstępną ocenę przydatności nowej metody do oczyszczania badanej wody, a także na zaplanowanie badań pilotowych, w tym ustalenie zakresów czasu kontaktu, stężenia oraz krotności wymian objętości żywicy. Stwierdzono, że proces MIEX®DOC jest skuteczniejszy w usuwaniu organicznych domieszek wody niż koagulacja. Jego zastosowanie pozwoli na obniżenie dawki koagulantu do minimum wynikającego z potrzeby klarowania wody. Zoptymalizowanie współdziałania procesów wymiany jonowej oraz koagulacji pozwoli na obniżenie oraz ustabilizowanie poziomu zanieczyszczenia organicznego badanej wody, co korzystnie wpłynie na pracę złóż sorpcyjnych, tworząc warunki do wydłużenia cyklu ich pracy.
The need of reducing the organic matter content in potable water to the lowest possible level has taken on a sense of urgency in technological terms, mainly due to the formation of disinfection by-products. The magnetized anion exchange resin (MIEX®) developed by Orica Watercare shows great promise for the removal of organic matter from water, when compared to classical water treatment processes. This paper shows the results of standard MIEX®DOC laboratory tests, such as kinetic, simulation and coagulation tests performed on the river water taken in for the Water Treatment Plant of Wrocław (Mokry Dwór). With the results obtained it was possible to estimate the main parameters of the overall MIEX®DOC process, such as contact time, resin concentration, and resin bed volume. On average, the MIEX®DOC process yielded a much higher DOC removal, and much lower UV absorption, as compared to standard coagulation with PAX-18. Another series of experiments was carried out to study a sequence MIEX®DOC followed by coagulation. It was found that this setup allowed the coagulant dose to be lowered to the level typical of standard turbidity removal, since the MIEX®DOC process did not remove turbidity from the tested water.
Źródło:
Ochrona Środowiska; 2005, R. 27, nr 2, 2; 3-7
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Change of toxicity of water containing bisphenol A during its treatment by complex oxidation process
Zmiany toksyczności wody zawierającej bisfenol a w trakcie jej uzdatniania w złożonym procesie utleniającym
Autorzy:
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/388558.pdf
Data publikacji:
2014
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
bisphenol A
water treatment
toxicity
Microtox® biotest
bisfenol A
uzdatnianie wody
toksyczność
biotest Microtox®
Opis:
Water containing bisphenol A was UV irradiated (medium pressure immersion lamp with the electric power of 150 W) with and without the addition of H2O2 (6–12 mg/dm3 dose). To control of the water quality Microtox® biotest was used. Bioluminescent bacteria Vibrio fisheri was involved. Decomposition of bisphenol A was depended on the UV irradiation time and dose of the H2O2. The observations connected with the bioluminescence value in the examined solutions were surprised. Decomposition of the compound did not cause of decrement the bioluminescence inhibition value characterizing solution indicating the formation of toxic intermediates products. However, the combined use of H2O2 with UV radiation improves the rate of decomposition of bisphenol A, but also causes an increase in bioluminescence inhibition of the solutions. For this reason selection of the most favorable conditions for the oxidative process have to be proceed based on both agents: effectiveness of the compounds decomposition and the toxicity of the solution after process.
Wodę zawierającą bisfenol A poddano napromieniowaniu UV (zanurzeniowa lampa średniociśnieniowa o mocy elektrycznej 150 W) bez i z dodatkiem H2O2 (dawka 6–12 mg/dm3). Do kontroli jakości wody zastosowano biotest Microtox® wykorzystujący bakterie bioluminescencyjne Vibrio fisheri. Określono, że rozkład bisfenolu A zależał od czasu napromieniowania UV jak i dawki H2O2. Zaskakujące z kolei były obserwacje związane z wartością inhibicji bioluminescencji w badanych roztworach. Rozkład związku nie powodował obniżenia wartości inhibicji bioluminescencji charakteryzującej roztwór, co wskazuje na powstawanie toksycznych produktów pośrednich. Z kolei łączne zastosowanie nadtlenku wodoru z promieniowaniem UV poprawia stopień rozkładu bisfenolu A, ale jednocześnie powoduje wzrost wartości inhibicji bioluminescencji roztworów. Z tego względu w doborze najkorzystniejszych warunków prowadzenia procesu utleniającego nie można opierać się wyłącznie na skuteczności rozkładu związków, lecz należy również rozważyć toksyczność roztworu poprocesowego.
Źródło:
Ecological Chemistry and Engineering. A; 2014, 21, 3; 269-277
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ technologii oczyszczania wody na proces kształtowania biofilmu na wybranych materiałach instalacyjnych
The influence of water treatment technology on the process of biofilm formation on the selected installation materials
Autorzy:
Pietrzyk, A.
Papciak, D.
Powiązania:
https://bibliotekanauki.pl/articles/104329.pdf
Data publikacji:
2017
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
uzdatnianie wody
jakość wody
błona biologiczna
mikroskopia skaningowa
water treatment
water quality
biological membrane
scanning microscopy
Opis:
W artykule oceniono wpływ technologii oczyszczania wody na proces formowania obrostów biologicznych na wybranych materiałach instalacyjnych (miedzi, stali ocynkowanej oraz polipropylenie). W pracy określona została podatność badanych powierzchni na powstawanie biofilmów. Wykorzystując techniki skaningowej mikroskopii elektronowej obserwowano zmiany zachodzące na powierzchniach materiałów instalacyjnych. Jakość wód pozostających w kontakcie z próbkami poddana została dodatkowo analizie mikrobiologicznej w celu oszacowania zmian liczebności drobnoustrojów w trakcie trwania eksperymentu. Wykonane zdjęcia SEM wykazały znaczne różnice w strukturze przestrzennej powstałych biofilmów w zależności od jakości wody oraz rodzaju badanego materiału instalacyjnego. Technologia oczyszczania wody miała wpływ na powstawanie i strukturę obrostu biologicznego. Stwierdzono, że materiałem szczególnie podatnym na adhezję mikroorganizmów jest stal ocynkowana. Powierzchnia tego materiału została całkowicie zdominowana przez komórki bakterii, a utworzony biofilm charakteryzował się złożoną strukturą przestrzenną. Miedź okazała się najbardziej odporna na kolonizację przez mikroorganizmy.
The influence of water treatment technology on the process of biofilm formation on the selected plumbing materials (copper, galvanized steel and polypropylene) was assessed in this paper. The sensitivity of the investigated surfaces to biofilm formation was determined in the paper. Using the scanning electron microscope technique, changes occurring on the surfaces of the installation materials have been observed. The quality of the water in contact with the samples was subjected to microbiological analysis in order to estimate changes in the abundance of microorganisms during the experiment. The SEM photos showed significant differences in the spatial structure of the biofilms depending on the quality of the water and the type of test material. Water treatment technology has influenced the formation and structure of biological growth. It has been found that the material particularly susceptible to the adhesion of microorganisms is galvanized steel. The surface of this material was completely dominated by bacterial cells, and the biofilm formed was characterized by a complex spatial structure. Copper has proven to be the most resistant to colonization by microorganisms.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2017, 64, 2/II; 131-143
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the possibility of replacing the rapid filtration process with ultrafiltration in surface water treatment systems
Autorzy:
Wolska, Małgorzata
Wisniewski, Jacek A.
Ferenc, Zbigniew
Adamski, Wojciech
Mołczan, Marek
Pawłowska, Magdalena
Szerzyna, Slawomir
Powiązania:
https://bibliotekanauki.pl/articles/2032923.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
water treatment
coagulation
sedimentation
filtration
uzdatnianie wody
koagulacja
sedymentacja
filtracja
Opis:
The presented study aimed to compare the effectiveness of ultrafiltration and filtration through a sand bed during the water treatment process after the coagulation and sedimentation. The study was conducted in two flow-type water treatment systems: the reference and the test system. Both systems functioned continuously with a throughput of 1 m3/h. The research has shown that both processes ensured a very effective removal of post-coagulation suspensions, however, ultrafiltration was more effective. The filtration process allowed a slightly higher removal of organic substances as compared to ultrafiltration. The effectiveness of the removal of organic substances was determined by the biological activity of sand beds, which is not allowed in the ultrafiltration process. Besides, during the filtration process, aluminum remaining after coagulation was more effectively removed. In turn, the ultrafiltration process ensured an almost 100% effectiveness in reducing the total microorganism cell count, while the effectiveness of the filtration process was approximately half of that. In the end, the possibility of replacing the filtration process with the ultrafiltration process is determined by the costs of both processes.
Źródło:
Environment Protection Engineering; 2021, 47, 2; 83-92
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ zmiany rodzaju koagulantu na parametry procesu koagulacji
Effect of the type of the coagulant on the parameters of the coagulation process
Autorzy:
Kłos, M.
Gumińska, J.
Powiązania:
https://bibliotekanauki.pl/articles/237820.pdf
Data publikacji:
2007
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie wody
koagulacja
koagulant hydrolizujący
koagulant wstępnie zhydrolizowany
water treatment
coagulation
hydrolyzing coagulant
pre-hydrolyzed coagulant
Opis:
W obecnej praktyce wodociągowej stosuje się koagulanty hydrolizujące (np. siarczan glinu) oraz wysokozasadowe koagulanty wstępnie zhydrolizowane. W pracy przedstawiono wyniki badań laboratoryjnych, pilotowych oraz rezultaty uzyskane podczas eksploatacji układów technicznych, przeprowadzone w celu określenia wpływu zmiany rodzaju koagulantu na przebieg procesów technologicznych, ze szczególnym uwzględnieniem koagulacji. W oparciu o uzyskane dane stwierdzono, że zastosowanie koagulantów wstępnie zhydrolizowanych w miejsce reagentów hydrolizujących pozwala na zmniejszenie stosowanych dawek, zmniejszenie ilości powstających zawiesin pokoagulacyjnych oraz poprawę stabilności chemicznej wody. Zmiana rodzaju koagulantu powinna być jednak poprzedzona badaniami laboratoryjnymi i pilotowych, które pozwolą na kompleksową ocenę wpływu zmiany koagulantu na przebieg całego proces oczyszczania wody.
The use of hydrolyzing coagulants (e.g. aluminum sulfate) and prehydrolyzed high-alkalinity coagulants is now commonplace in water treatment plants. In this paper, the results of laboratory- and pilot-scale tests are presented, as well as those obtained under full-scale conditions involving a real treatment train. The aim of the study was to examine how the replacement of a coagulant type (a hydrolyzing reagent) with another one (a prehydrolyzed coagulant) influences technological processes in general, and that of the coagulation process in particular. The results have revealed the following advantages of such replacement: a reduction in the coagulant dose required, a lower quantity of the precipitate produced, and a higher chemical stability of the water. It is essential to note, however, that before the coagulant is replaced, laboratory and pilot tests have to be performed in order to assess how the change of the coagulant will influence the course of the whole treatment process.
Źródło:
Ochrona Środowiska; 2007, R. 29, nr 4, 4; 73-76
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usuwanie mykoestrogenów z roztworów wodnych w zintegrowanym procesie fotokataliza-mikrofiltracja-nanofiltracja
Removal of mycoestrogens from aqueous solutions in the integrated photocatalysis-microfiltration-nanofiltration process
Autorzy:
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/236700.pdf
Data publikacji:
2012
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie wody
mykoestrogeny
proces zintegrowany
fotokataliza
nanofiltracja
water treatment
mycoestrogens
integrated process
photocatalysis
nanofiltration
Opis:
Wykazano dużą skuteczność (>90%) usuwania zanieczyszczeń, w tym małocząsteczkowych mykoestrogenów (zearalenon i [alfa]-zearalenol w ilości 500 mg/m3) w zintegrowanym procesie oczyszczania wody fotokataliza-mikrofiltracja-nanofiltracja. Skuteczność usuwania mykoestrogenów w tym procesie była znacznie większa niż w samym procesie fotokatalizy. Porównując skuteczność samej nanofiltracji ze skutecznością procesu zintegrowanego stwierdzono, że usunięcie mykoestrogenów w obu przypadkach było zbliżone, jednakże realizacja nanofiltracji w procesie zintegrowanym była korzystniejsza pod względem wydajności hydraulicznej membrany. Rozpatrując skuteczność i wydajność nanofiltracji w procesie zintegrowanym wykazano większą przydatność membran wykonanych z octanu celulozy (CK) niż membran kompozytowych (DK) o poliamidowej warstwie naskórkowej, które były bardziej podatne na blokowanie. Wprowadzenie do układu oczyszczania wody fotokatalizy przed nanofiltracją w zasadniczy sposób ograniczyło występowanie zjawiska blokowania membran. Należy wziąć jednak pod uwagę niebezpieczeństwo pojawienia się w wodzie związków organicznych o mniejszej masie cząsteczkowej niż występujące w wodzie modelowej, co może zmniejszyć skuteczność procesu oczyszczania.
The efficiency of pollutant removal obtained with the integrated photo-catalysis-microfiltration-nanofiltration process exceeded 90%, which includes the removal of low-molecular-weight mycoestrogens (zearalenone and [alfa]-zearalenole, at concentrations of 500 mg/m3). The extent of mycoestrogen removal was significantly higher in the integrated process than in photocatalysis alone. Comparisons have shown that nanofiltration alone produced removal of mycoestrogens similar to that obtained in the integrated process, but when nanofiltration was integrated with photocatalysis and microfiltration, the hydraulic capacity of the membrane was more advantageous. Analysis of the efficiency and capacity of nanofiltration in the integrated process substantiated the advantage of cellullose acetate membranes over composite membranes with polyamide skin, which display greater proneness to clogging. When in the integrated system photocatalysis preceded nanofiltration, the occurrence of membrane clogging was noticeably reduced. Yet, there is still a real risk that surface water may contain organic compounds with lower molecular weight as compared to those present in model solutions, and this may cause the removal efficiency of the treatment process to decline.
Źródło:
Ochrona Środowiska; 2012, 34, 1; 29-32
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Supporting the process of removing humic substances on activated carbon
Autorzy:
Olesiak, Paulina
Stępniak, Longina
Powiązania:
https://bibliotekanauki.pl/articles/1039200.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
water treatment
biosorption
biodegradation
ultrasounds
Opis:
This study is focused on biosorption process used in water treatment. The process has a number of advantages and a lot of research has been done into its intensification by means of ultrasonic modification of solutions. The study carried out by the authors leads to the conclusion that sonication of organic solutions allows for extension of the time of operation of carbon beds. For the analysis of the results obtained during the sorption of humic substances (HS) from the solution dependencies UV/UV0 or DOC/DOC0 were used. In comparative studies the effectiveness of sorption and sonosorption (UV/UV0) shows that the share of ultrasounds (US) is beneficial for extension of time deposit, both at a flow rate HS solution equal to 1 m/h and 5 m/h. Analysis of the US impact sorption on HS sorption in a biological fluidized bed, both prepared from biopreparat and the activated sludge confirms the higher efficiency compared to sonobiosorption than biosorption. These results confirm the degree of reduction UV254/UV0 and DOC/DOC0 for the same processes. EMS index also confirms the improvement of HSbiodegradation by sludge microorganisms.
Źródło:
Acta Biochimica Polonica; 2014, 61, 4; 711-716
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stabilizowanie przebiegu procesu koagulacji zanieczyszczeń wody o zmiennej jakości przez zastosowanie recyrkulacji osadu pokoagulacyjnego
Stabilization of coagulation process of variable quality water by post-coagulation sludge recirculation
Autorzy:
Gumińska, J.
Powiązania:
https://bibliotekanauki.pl/articles/236981.pdf
Data publikacji:
2015
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie wody
mechanizm koagulacji
koagulant wstępnie zhydrolizowany
dawka optymalna
water treatment
coagulation mechanism
pre-hydrolyzed coagulant
optimal dose
Opis:
Podczas eksploatacji konwencjonalnych systemów oczyszczania wód górskich występują trudności w szybkim dostosowaniu dawki koagulantu do nagłych i znacznych zmian jakości ujmowanej wody. Wynika to głównie z małych właściwości buforujących tego typu wód i ich zmiennej jakości (zarówno dobowej, jak i godzinowej) w ciągu roku. Z tego względu utrzymanie odpowiednich warunków prowadzenia procesu koagulacji, a głównie dawki koagulantu i pH wody, jest bardzo trudne. Stosowanie typowych koagulantów hydrolizujących w takich warunkach skutkuje niekontrolowanymi wahaniami wartości pH, hamując całkowicie proces oczyszczania wody. Brak możliwości natychmiastowego dostosowania dawki koagulantu do zmian jakości wody powoduje, że przez pewien czas następuje przedawkowanie albo stosowanie zbyt małej dawki koagulantu w stosunku do wymaganej wartości, co skutkuje pogorszeniem jakości wody oczyszczonej. Dlatego też w miejsce koagulantów hydrolizujących w stacjach oczyszczania ujmujących wody górskie wprowadza się reagenty wstępnie zhydrolizowane, takie jak chlorek poliglinu. Wyniki badań pilotowych wykazały, że skuteczną metodą utrzymania wysokiej skuteczności procesu koagulacji, zarówno w warunkach przedawkowania, jak i stosowania zbyt małej dawki koagulantu wstępnie zhydrolizowanego, jest prowadzenie recyrkulacji osadu pokoagulacyjnego do układu flokulacji.
Operating conventional treatment systems of mountain waters generates difficulties in immediate coagulant dose adjustment to sudden and significant changes in raw water quality. This is mainly due to poor buffering properties of this type of water and its varying quality, both daily and hourly, over the course of the year. This is the reason why the maintenance of optimum conditions for coagulation process, especially coagulant dose and water pH, is very difficult. Under such conditions, application of typical hydrolyzing coagulants results in uncontrolled pH drops, completely inhibiting the water treatment process. An inability to immediately adjust the coagulant dose to variations in water quality causes overdosing or underdosing of coagulant in relation to its optimal value, leading to deterioration of treated water quality. Therefore, instead of hydrolyzing coagulants at mountain water treatment stations the pre-hydrolyzed coagulants are introduced, such as polyaluminium chlorides (PAC). The pilot study results show that the use of post-coagulation sludge recirculation into flocculation system is an effective method to maintain high and stable coagulation effectiveness, both under an overdose and underdose conditions.
Źródło:
Ochrona Środowiska; 2015, 37, 4; 9-12
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ układu oczyszczania wody na zakres stosowalności procesu MIEX®DOC
The effect of the water treatment train on the range of applicability for the MIEX®DOC process
Autorzy:
Mołczan, M.
Karpińska, A.
Powiązania:
https://bibliotekanauki.pl/articles/236894.pdf
Data publikacji:
2007
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie wody
wymiana jonowa
żywica MIEX
koagulacja
ozonowanie
water treatment
ion exchanger
MIEX® resin
ozonation
Opis:
Analiza położenia zakresu stosowalności procesu MIEX®DOC miała na celu wskazanie racjonalnych wartości podstawowych parametrów tego procesu, tj. dawki żywicy i czasu kontaktu. Wykazano, że zakres ten ograniczony jest skrajnymi wartościami iloczynu dawki żywicy i czasu kontaktu (FPmin; FPmaks), określonymi na podstawie badania przebiegu krzywej kinetycznej. Położenie zakresu stosowalności określono badając wodę powierzchniową ujmowaną do zaopatrzenia Wrocławia, oczyszczaną w układzie technologicznym składającym się z koagulacji, filtracji (sand filtration), ozonowania pośredniego, filtracji przez złoże węglowe (GAC) i dezynfekcji. W badaniach nie stwierdzono wyraźnie powtarzalnych relacji w przebiegach krzywych kinetycznych procesu stosowanego w różnych miejscach układu technologicznego. Wyraźna była natomiast tendencja do obniżania wartości dolnej granicy zakresu stosowalności po kolejnych procesach oczyszczania, z wyjątkiem wody po filtracji przez złoże węgla aktywnego. Podobna tendencja w odniesieniu do górnej granicy zakresu stosowalności była znacznie mniej powtarzalna. Wykazano, że wraz z postępującym stopniem oczyszczenia wody zakres stosowalności procesu MIEX®DOC ulegał zawężeniu oraz nieznacznemu przesunięciu w kierunku niższych wartości iloczynu dawki żywicy i czasu kontaktu. W konsekwencji można wnioskować, że lokowanie procesu wymiany anionowej po kolejnych procesach oczyszczania wody będzie wiązało się z malejącymi nakładami na jego realizację. Biorąc jednak pod uwagę znacznie szybciej malejące ładunki usuwanych zanieczyszczeń, nakłady jednostkowe będą wzrastały.
The position of the range of applicability for the MIEX®DOC process was analyzed in order to indicate the rational values for the basic parameters of the process (resin dosage, contact time). The applicability range was found to be limited by the extreme values of the product of resin dosage and contact time (FPmin; Fpmax) defined from the plot of the kinetic curve. The position of the applicability range was determined by analyzing samples of surface water (taken in for municipal supply to the city of Wroclaw) treated via a treatment train involving coagulation, sand filtration, direct ozonation, GAC filtration and disinfection. The study revealed no apparently repeatable relations in the plots of the kinetic curves for the process applied at various points of the treatment train. However, the lower limit values of the applicability range showed a tendency to decrease after successive unit processes (except after GAC filtration). As for the upper limit values of the applicability range, this tendency was less repeatable. It was demonstrated that as the efficiency of the treatment process increased, the applicability range for the MIEX®DOC process became narrower, and there was a slight shift towards the lower values of the product of resin dosage and contact time. Hence, it can be concluded that the location of the anion exchange process after successive unit processes will involve decreasing operating expenses. But taking into account the decrease in the quantity of the organics removed (which proceeds at a much faster rate), unit expenses will tend to increase.
Źródło:
Ochrona Środowiska; 2007, R. 29, nr 1, 1; 11-17
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ procesu wymiany anionowej na zmianę jakości domieszek organicznych wody charakteryzowanych wartościami absorbancji właściwej (SUVA) i barwy właściwej (SCOA)
Effect of the anion exchange process on the change in the quality of organic water pollutants characterized by the specific UV absorbance (SUVA) and specific colour absorbance (SCOA) values
Autorzy:
Mołczan, M.
Powiązania:
https://bibliotekanauki.pl/articles/236935.pdf
Data publikacji:
2007
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie wody
wymiana anionowa
żywica MIEX
absorbancja właściwa
substancje organiczne
water treatment
organics removal
ion exchanger
MIEX® resin
specific UV absorbance
specific colour absorbance
Opis:
Zarówno barwa, jak i absorbancja w nadfiolecie charakteryzują jakość obecnych w wodzie substancji organicznych. Absorbancja właściwa (SUVA - Specific UV Absorbance) oraz barwa właściwa (SCOA - Specific Colour Absorbance) opisują zagęszczenie cech substancji organicznych związanych z ich potencjalną reaktywnością (SUVA) oraz zdolnością do nadawania wodzie zabarwienia (SCOA). Wartości tych wskaźników pozwalają na ocenę selektywności procesów oczyszczania wody pod kątem usuwania organicznych zanieczyszczeń barwnych (których zawartość jest ograniczona) oraz reaktywnych (których zawartość jest ograniczona pośrednio, np. ubocznych produktów dezynfekcji, środka dezynfekcyjnego itp.). Procesem zdolnym do selektywnego usuwania substancji organicznych cechujących się dużymi wartościami absorbancji w UV oraz barwy właściwej jest wymiana anionowa na namagnetyzowanych żywicach drobnoziarnistych MIEX® . Wykazano, że składniki usuwane z wody w procesie wymiany anionowej wykazują wartość absorbancji właściwej oraz barwy właściwej odpowiednio o 6悝% oraz 5悛% wyższą od wartości charakteryzujących wodę surową. Wodę oczyszczoną cechują natomiast wartości tych wskaźników odpowiednio o 14悯% oraz 12悹% niższe niż w wypadku wody surowej. Stwierdzono, że proces wymiany anionowej może potencjalnie dać podobną skuteczność zmniejszenia wartości SUVA, jaki jest osiągany w całym ciągu technologicznym oczyszczania wody, złożonym z koagulacji, filtracji pospiesznej, ozonowania i biosorpcji.
The quality of the organic substances that are present in the water is characterized both by colour and UV absorbance. Specific UV Absorbance (SUVA) and Specific Colour Absorbance (SCOA) describe the density of the organic matter properties that are indicative of the potential reactivity (SUVA) and capability of the organic substance to colour the water (SCOA). Knowing the values of SUVA and SCOA enables the selectivity of the water treatment process to be assessed with respect to the removal of organic coloured matter (whose content is limited) and reactive substances (whose content is indirectly limited, e.g. by the by-products of disinfection, by disinfectant dosage, etc.). When the organics to be removed are characterized by high SUVA and SCOA values, anion exchange over magnetized fine-grained MIEX® resins is the treatment mode that provides a selective removal of such organic substances. The experiments have revealed the following: the organic pollutants being removed via anion exchange display SUVA and SCOA values that are by 6 to 33% and 5 to 31%, respectively, higher than those characterizing raw water; the SUVA and SCOA values of treated water are by 14 to 51% and 12 to 61% lower than those of raw water. The study has substantiated the potentiality of anion exchange for providing a reduction in the SUVA value similar to the one achieved by the entire water treatment train involving coagulation, rapid filtration, ozonation and biosorption.
Źródło:
Ochrona Środowiska; 2007, R. 29, nr 2, 2; 13-19
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie napowietrzania do poprawy skuteczności sedymentacji zawiesin powstających podczas oczyszczania wód podziemnych.
The use of the aeration process for upgrading the efficiency of suspended solids sedimentation during groundwater treatment.
Autorzy:
Łomotowski, J.
Wiercik, P.
Powiązania:
https://bibliotekanauki.pl/articles/236606.pdf
Data publikacji:
2009
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
wody podziemne
popłuczyny
napowietrzanie
sedymentacja
groundwater
backwash water
aeration
water treatment
Opis:
W pracy podjęto próbę wykorzystania procesu napowietrzania sprężonym powietrzem do poprawy skuteczności sedymentacji zawiesin powstających podczas oczyszczania wód podziemnych. Przeprowadzone doświadczenia wykazały, że napowietrzanie popłuczyn odprowadzanych z filtrów do odżelaziania i odmanganiania wody podziemnej przyspiesza wytrącanie związków żelaza i manganu oraz zwiększa szybkość i skuteczność klarowania wody w odstojnikach. W dużych i średnich zakładach oczyszczania wód podziemnych możliwe będzie zastosowanie napowietrzania do podczyszczania popłuczyn, a po usunięciu osadu można rozważyć zawrócenie sklarowanej wody nadosadowej przed układ oczyszczania. Stosując okresowe napowietrzanie popłuczyn przed sedymentacją możliwe jest znaczne skrócenie czasu ich przetrzymania w odstojnikach, a tym samym zmniejszenie wielkości tych urządzeń.
The aeration process involved compressed air and was aimed at improving the sedimentation of the suspended solids that form in the course of groundwater treatment. The experiments have revealed that the aeration of the backwash water from the filters used for iron and manganese removal from the groundwater being treated not only accelerated the precipitation of iron and manganese compounds but also increased the rate and efficiency of water clarification in the settling tanks. The use of compressed-air aeration seems to be recommendable in large and medium-sized groundwater treatment plants where the process can be applied to the pretreatment of backwash water. It also seems worthwhile to consider the possibility of recirculating (upon sludge removal) the clarified supernatant into the treatment train. Periodic aeration conducted prior to the sedimentation process will shorten the time of backwash water retention in the settling tanks and thus permit their dimensions to be reduced.
Źródło:
Ochrona Środowiska; 2009, 31, 4; 21-24
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Use of Biofiltration Process to Remove Organic Matter From Groundwater
Autorzy:
Papciak, D.
Kaleta, J.
Puszkarewicz, A.
Tchórzewska-Cieślak, B.
Powiązania:
https://bibliotekanauki.pl/articles/952351.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
groundwater
biofiltration process
total organic carbon (TOC)
water treatment
Opis:
The article describes the research on the removal of organic matter from natural underground water using biofiltration process. The study was carried out in semi-technical scale on a model filter composed of activated carbon WD-extra. The development of biological activity in a biosorption bed, as well as observations on the relationship between the processes of sorption and biodegradation was evaluated based on the Eberhardt, Madsen, Sontheimer (EMS) test. Leading operation control parameters of biologically active carbon filter BAF included: change of TOC content, dissolved oxygen and permanganate index. To evaluate the colonization of granular carbon determination of ATP value was used. The presence of the biofilm was found by observation using light and scanning microscopes. The organic compounds in the water taken were adsorbed 100% and 70% biodegradable. The combination of sorption process with biodegradation until depletion of activated carbon adsorption capacity allowed in the initial phase of coalbed work for the removal of organic matter in approx. 100%. Formation of biofilm at the right time allowed to extend the filtration cycle and helped lower the TOC by 70%, i.e. from 10 mg C/l to 3–4 mg C/l.
Źródło:
Journal of Ecological Engineering; 2016, 17, 3; 119-124
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies