Tytuł:
Failure risk analysis in the water distribution system
Autorzy:
Tchórzewska-Cieślak, B.
Powiązania:
https://bibliotekanauki.pl/articles/2069656.pdf
Data publikacji:
2010
Wydawca:
Uniwersytet Morski w Gdyni. Polskie Towarzystwo Bezpieczeństwa i Niezawodności
Tematy:
risk analysis
failure
risk
water distribution system
Opis:
A water distribution system (WDS) ought to be high reliable continuous operating system. Failure factors in WDS should be identified and prioritised, for example, the causing factors in the most frequent failures in water-pipe network. In this paper, the failure risk analysis of the WDS is presented, and accordingly, a New method consisting the failures index (FI) and the evaluation of risk of failure within the relevant area, based on the assumed categories (tolerable, controlled and unacceptable risk). It is expecting that the methodology for the WDS performance risk analysis would provide the city leadership for decision making support.
Źródło:
Journal of Polish Safety and Reliability Association; 2010, 1, 1; 247--254
2084-5316
Pojawia się w:
Journal of Polish Safety and Reliability Association
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nadezhnost vodoprovodnykh metalicheskikh trub Ukrainy
Reliability of metal water pipes of Ukraine
Autorzy:
Matjash, A.
Powiązania:
https://bibliotekanauki.pl/articles/77738.pdf
Data publikacji:
2014
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
pipe
reliability
water supply system
water distribution system
Ukraine
Źródło:
Motrol. Motoryzacja i Energetyka Rolnictwa; 2014, 16, 6
1730-8658
Pojawia się w:
Motrol. Motoryzacja i Energetyka Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Time-Spatial Analysis of the Functioning of the Water Distribution System in the Mathematical Modeling Process
Autorzy:
Trębicka, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/2105269.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
mathematical model
pumping station
water distribution system
failure analysis
energy
Opis:
This paper presents the process of the temporal and spatial functioning of the water distribution system in the mathematical modeling process. The research was carried out on the Bialystok water network model with particular emphasis on the efficiency and energy efficiency of the pumping units located on the analyzed water distribution system (SDW). The calculations and calibration of the model were performed using the ISYDYW software, with particular emphasis on time and spatial distribution. Particular situations were analyzed, especially when the system operated in exceptional conditions, which most often resulted in failure, leading to a shortage of water supply, and thus energy losses of the pumping units. The obtained results allowed demonstrating the auxiliary role of the simulation method in determining and predicting the effects on the existing emergency states. Possible scenarios were prepared for the observed changes, both in the entire network and at the selected points of the pump systems. Assuming the duration of the failure, its consequences were determined and presented in the form of the indicators discussed.
Źródło:
Journal of Ecological Engineering; 2022, 23, 6; 90--99
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza uszkodzeń i kosztów naprawy przewodów wodociągowych w okresie zimowym
Analysis of failure events and damage repair costs for water-pipe networks in the winter season
Autorzy:
Hotloś, H.
Powiązania:
https://bibliotekanauki.pl/articles/236554.pdf
Data publikacji:
2009
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
dystrybucja wody
sieć wodociągowa
water distribution system
water-pipe network
Opis:
Jedną z przyczyn występowania uszkodzeń przewodów wodociągowych w okresie zimowym jest nieprzestrzeganie, w czasie projektowania i budowy sieci, wymagań dotyczących minimalnej głębokości ułożenia przewodów ze względu na przemarzanie gruntu. Posadowienie przewodów w strefie przemarzania gruntu powoduje powstawanie uszkodzeń wskutek pęknięcia materiału rur, a nawet zamarznięcia wody. Dotyczy to zwłaszcza odcinków sieci o małej średnicy i bardzo małej prędkości przepływu wody. Przedstawione w pracy doświadczenia z eksploatacji sieci wodociągowych w Polsce i we wschodnich landach Niemiec wykazały, że czynniki te spowodowały bardzo dużo awarii i strat finansowych, szczególnie w czasie srogiej zimy na przełomie lat 1995/1996. W wybranych systemach wodociągowych w kraju (Brzeg, Kłodzko, Oleśnica, Wrocław, Opole, Świdnica) dokonano analizy częstości uszkodzeń przewodów magistralnych i rozdzielczych w miesiącach jesienno-zimowych i wiosenno-letnich (z obserwacji w wieloleciu oraz w 1996 r.). W większości systemów odnotowano kilkakrotnie większą intensywność uszkodzeń przewodów w miesiącach zimowych niż w pozostałym czasie. Dotyczyło to w większym stopniu uszkodzeń rurociągów (głównie pęknięcia rur) niż armatury. Trudne warunki atmosferyczne spowodowały także wzrost kosztów naprawy poszczególnych rodzajów uszkodzeń przewodów, a w konsekwencji bardzo duże koszty naprawy sieci w okresie zimowym. Przeprowadzona analiza eksploatacji sieci wodociągowej we Wrocławiu wykazała, że średnie miesięczne koszty naprawy uszkodzeń w czasie od stycznia do marca 1996 r. były nawet sześciokrotnie większe niż w pozostałych miesiącach tego roku.
One of the major underlying causes of water pipe failure in the winter season is negligence (during design and construction of the network) in conforming to the regulations that specify the minimal depth for pipe laying. When the pipeline is laid within a freezing soil layer, this will contribute to the occurrence of failure events due to pipe burst or frozen water, which holds true specifically for pipeline segments of a small diameter and very low flow velocity. In this paper observations are reported on the water-pipe networks that are in service in Poland and in the eastern Lands of Germany. They have revealed a very high number of frost-related failure events, as well as heavy financial losses concomitant with pipe failure, particularly during the harsh winter of 1996. In Poland, six water-pipe networks of choice (Brzeg, Klodzko, Olesnica, Wroclaw, Opole and Swidnica) were analyzed for the number of failure events in distributing pipes and mains in the autumn and winter months (November-February), as well as in the spring and summer months (March-October). Those analyses were based on many years' observations, with emphasis on the ones made in 1996. In the majority of instances, the rate of failure in the time span of November to February was several times as high as in the other months, and was observed in the water-pipe network rather than fittings. The harsh weather conditions are also to be blamed for the rise in the repair costs for particular types of pipe damage and, more importantly, for the very high costs of the repairs that had to be done in the water-pipe network during the winter months. In-service analysis of the Wroclaw water-pipe network has shown that the average monthly costs of damage repair in the time span of January to March 1996 were even six times those observed in the other months of that year.
Źródło:
Ochrona Środowiska; 2009, 31, 2; 41-48
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Model-Based Approach to Risk Evaluation and the Assessment of Protection Provided by Water Intake and Treatment Systems
Autorzy:
Wysowska, Ewa
Kicińska, Alicja
Powiązania:
https://bibliotekanauki.pl/articles/2173238.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
health risk
metals
organic compound
microbiological pathogen
water distribution system
Opis:
This study presents an assessment of the protection provided by water intake and treatment systems against potential health risk to water consumers. To perform the assessment a case study was conducted involving modelling and risk assessment based on scenarios of decreasing water quality at the intakes (i.e. emergency situations). The study sites were two continuously operating water treatment plants in Southern Poland (CEE). The study material were the results of tests conducted in the years 2012–2019 on samples of water taken directly at the intakes and samples of treated water. The samples were used to determine the concentration of selected metals (Cd, Cr, Mn, Ni, Pb and Zn), organic pollutants (benzo(a)pyrene, benzene, acrylamide, epichlorohydrin, vinyl chloride and 1,2-dichloroethane) and bacteriological pollutants (Coliform bacteria, Escherichia coli, Enterococcus faecali and Clostridium perfringens). The non-carcinogenic (HI) and carcinogenic (CR) hazard indexes were estimated based on the quality of water at the intake using linear regression models. The risk values obtained were compared with permissible values specified in the US EPA methodology. It was demonstrated that the concentrations of the xenobiotics analysed in treated water would have to increase 11 times in the case of adults and 29 times in the case of children before the risk level related to drinking water exceeded permissible values. In the least favourable exposure scenario modelled, assuming the presence of organic xenobiotics in potable water, the total HI amounts to only 10% of the permissible value in adults and 1.5% in children. The total CR calculated for the 3-times lower water quality did not exceed permissible values, which proves that the water treatment systems are safe.
Źródło:
Journal of Ecological Engineering; 2022, 23, 7; 284--298
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie analizy jakości wody do oceny pracy sieci wodociągowej
Application of Water Quality Analysis to the Modeling of a Water Distribution System
Autorzy:
Kłos, M.
Zimoch, I.
Powiązania:
https://bibliotekanauki.pl/articles/237233.pdf
Data publikacji:
2005
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
system wodociągowy
modelowanie
jakość wody
water distribution system
modeling
water quality
Opis:
W wielu małych systemach wodociągowych problemy z wtórnym zanieczyszczeniem wody w systemie dystrybucji są szczególnie uciążliwe, z uwagi na często wadliwą strukturę sieci, niekorzystną czasową strukturę poboru wody oraz brak armatury kontrolno-pomiarowej. Dane eksploatacyjne tych systemów zawierają jednak pewien zakres analiz wskaźników jakości wody, prowadzonych zarówno podczas rutynowych, obowiązkowych badań, jak i interwencyjnie, podczas kontroli i usuwania awarii sieci. Dane te mogą stanowić bardzo cenne źródło informacji, pozwalające na potwierdzenie lub odrzucenie pewnych założeń dotyczących modelu hydraulicznego i mechanizmów przemian jakościowych w systemach, gdzie inne sposoby weryfikacji są niemożliwe. W artykule przedstawiono wyniki analizy systemu wodociągowego małej miejscowości. Na podstawie minimalnego zakresu informacji dotyczących ilości wody podanej do systemu, a także danych dotyczących zakupu oraz struktury sieci, stworzono jej model hydrauliczny. Z uwagi na brak możliwości jego kalibracji, do oceny jego poprawności i stopnia zgodności z rzeczywistością wykorzystano dane analiz jakościowych wody, obejmujące zarówno analizy rutynowe, jak wyniki specjalnie zaprogramowanego systemu monitoringu punktów krytycznych.
Recent years have witnessed a continuing decrease in potable water demand, which raises serious problems in small water distribution systems rather than in the large ones. This is so because small systems generally operate defective distribution networks, as well as suffer from considerable variations in water demand and a shortage of monitoring devices. The first step to upgrade the performance of such systems includes the construction of a hydraulic model describing a small distribution system. However, the calibration of the model may be troublesome when flow and pressure data are lacking. In such instances it is possible to make use of the water quality data collected on other occasions (analyses of water quality parameters during routine investigations or failure damage removal, etc.). This paper reports on a study where a water distribution system in a small locality was analyzed. The available information was poor (amount of water passed to the system, purchase and structure of the network, water quality data collected at critical points), yet it was possible to construct, calibrate and verify the hydraulic model describing the water distribution system of interest.
Źródło:
Ochrona Środowiska; 2005, R. 27, nr 4, 4; 27-30
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of the Effect of Environmental Factors on the Corrosion of Water Distribution System Based on Analysis of On-line Corrosion Monitoring Results
Autorzy:
Jażdżewska, A.
Gruszka, M.
Mazur, R.
Orlikowski, J.
Banaś, J.
Powiązania:
https://bibliotekanauki.pl/articles/355721.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
water distribution system
acid rain
corrosion monitoring
online
linear polarization method
Opis:
Corrosion of water distribution system is a significant issue causing problems with quality, safety and continuity of distribution. The changes of corrosion rates of the water distribution systems in Cracow made of carbon steel were investigated by analysis of online corrosion monitoring system results. Corrosion rates were determined using the linear polarization method. The impactof rain, temperatures, conductivity, dissolved oxygen content on corrosion rate were characterized. The corrosivity of different water sources like mountain water, underground water or river water were indicated. The possible actions for reducing corrosion losses were characterized. Results show that pollution of the environment in the form of acid rain and runoff from agriculture as well as the type of the source water has significant influence on corrosion of water distribution system. Corrosion monitoring system gives possibility of controlling corrosion rate by mixing waters from different sources in the way to obtain less corrosive mixture. (see Fig 8).
Źródło:
Archives of Metallurgy and Materials; 2020, 65, 1; 109-116
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Genetic algorithms and neural networks for solving water quality model of the Egyptian research reactor
Autorzy:
El-Sayed Wahed, M.
Ibrahim, W. Z.
Effat, A. M.
Powiązania:
https://bibliotekanauki.pl/articles/148150.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
genetic algorithm
neural networks
model calibration
water distribution system
water quality model
Opis:
The second Egyptian research reactor ETRR-2 became critical on 27th November, 1997. The National Center of Nuclear Safety and Radiation Control (NCNSRC) has the responsibility for the evaluation and assessment of safety of this reactor. Modern managements of water distribution system (WDS) need water quality models that are able to accurately predict the dynamics of water quality variations within the distribution system environment. Before water quality models can be applied to solve system problems, they should be calibrated. The purpose of this paper is to present an approach which combines both macro and detailed models to optimize the water quality parameters. For an efficient search through the solution space, we use a multi-objective genetic algorithm which allows us to identify a set of Pareto optimal solutions providing the decision maker with a complete spectrum of optimal solutions with respect to the various targets. This new combinative algorithm uses the radial basis function (RBF) metamodeling as a surrogate to be optimized for the purpose of decreasing the times of time-consuming water quality simulation and can realize rapidly the calibration of pipe wall reaction coefficients of chlorine model of large-scaled WDS.
Źródło:
Nukleonika; 2009, 54, 4; 239-245
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Water Age and Flushing of the Water Supply Network of the Pressure Reduction Zone
Autorzy:
Świętochowska, Martyna
Bartkowska, Izabela
Powiązania:
https://bibliotekanauki.pl/articles/2202171.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
water distribution system
water age
water quality
flushing water system
pressure zone
Opis:
The water of appropriate quality introduced in the water system changes its chemical properties. Depending on the chemical properties of water and pipe materials, various phenomena may occur, e.g. corrosion, and biofilm structure. The decreasing water demand in existing water systems leads to a reduction in the water flow velocity in the pipes. Accordingly, the age of the water in the system increases. It is especially visible at connections and long sections of the network. The deteriorating water quality along with the elapsing time of its stay in the pipes makes it necessary to perform appropriate measures, e.g. flushing the network. Water supply services usually perform them intuitively. The choice of flushing sites, times, or flow rates is not measured and verified. The age of the water and the efficiency of flushing can be simulated in computer programs. EPANET provides tools for such simulations. The research aimed to check the effects of flushing the network and the age of water in the pressure reduction zone. This is a case that is particularly prone to the increasing age of water. The research has shown that the network flushing sites used so far contribute to the exchange of water in the main water pipes. The simulations showed the need for the additional flush in new places, and in the tested case, the age of the water in the pipes is as much as the intervals between subsequent rinses.
Źródło:
Journal of Ecological Engineering; 2022, 23, 10; 229--238
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie metod geostatystycznych do analizy zmienności składu wody w systemach wodociągowych
Application of the Kriging Method to the Analysis of Water Composition Variations in the Water Distribution System
Autorzy:
Łomotowski, J.
Skwarek, J.
Powiązania:
https://bibliotekanauki.pl/articles/236638.pdf
Data publikacji:
2003
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
jakość wody
geostatystyka
kriging
sieć wodociągowa
water quality
geostatistics
water distribution system
Opis:
Jakość wody w sieci wodociągowej ulega bardzo często niekorzystnym zmianom. W pracy wykazano, że oparciu o wyniki badań składu wody wodociągowej można, stosując geostatystyczną metodę krigingu, sporządzać mapy zmienności wskaźników jakości wody na obszarze zasilanym przez dany system. Mapy krigingowe, pomimo pewnych ograniczeń metodycznych, mogą być wykorzystywane do oceny i przebiegu zjawisk fizyczno-chemicznych i biologicznych zachodzących w wodzie zgromadzonej w sieci wodociągowej.
It is a well-established fact that in a water distribution system water quality undergoes some undesired changes. Our study shows that monitoring the composition of the tap water and making use of the kriging method it is possible to plot maps visualizing the variability of water quality indexes in the area fed by a given water distribution system. In spite of some methodological drawbacks, the kriging maps can be of utility in assessing the phenomena that occur in water distribution system.
Źródło:
Ochrona Środowiska; 2003, R. 25, nr 4, 4; 61-64
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie wskaźników strat wody do oceny efektywności jej dystrybucji w systemach wodociągowych
Application of water loss indicators as a measure of its distribution effectiveness in water supply systems
Autorzy:
Kwietniewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/237063.pdf
Data publikacji:
2013
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
system dystrybucji wody
wskaźnik strat wody
ILI
water distribution system
water loss indicator
Opis:
Wykorzystanie międzynarodowych standardów szacowania strat wody do oceny efektywności systemu jej dystrybucji przekłada się bezpośrednio na możliwość poprawy jakości zarządzania systemami wodociągowymi. W pracy wykazano nieprzydatność do tej oceny procentowego wskaźnika strat wody, który nie uwzględnia wielu czynników wpływających istotnie na wielkość tych strat. Przeprowadzone rozważania zostały odniesione do standardów światowych w zakresie zarządzania systemami dystrybucji wody, rekomendowanych przez International Water Association (IWA). Najważniejszą miarą, jaką wykorzystano do oceny efektywności dystrybucji wody w systemach wodociągowych był infrastrukturalny wskaźnik wycieków (ILI – Infrastructure Leakage Index). Dużą przydatność tego wskaźnika zilustrowano na przykładzie oceny efektywności dystrybucji wody w mieście średniej wielkości (Siedlce). Uzyskane wyniki (ILI w przedziale 2÷4) potwierdzają możliwość wprowadzenia usprawnień w celu zwiększenia rentowności systemów wodociągowych poprzez poprawę zarządzania ciśnieniem w sieci, aktywną kontrolę wycieków oraz konserwację sieci.
Application of international standards of water loss estimates to the effectiveness assessment of water distribution system translates into the opportunity to improve quality of water supply system management. The water loss percentage indicator is found not to be useful for water loss estimates as it does not take into account many factors significantly affecting the magnitude of losses. The presented considerations relate to global standards for water distribution system management, recommended by the International Water Association (IWA). A key measure used to evaluate the effectiveness of water distribution in water supply systems is the infrastructure leakage index (ILI). Great usefulness of this parameter is illustrated by the exemplary evaluation of water distribution system for the medium-sized town of Siedlce. The results obtained (ILI in the range of 2–4) confirm that in order to increase profitability of water supply systems there is a potential for improvements in terms of network pressure management, leakage control, and network maintenance.
Źródło:
Ochrona Środowiska; 2013, 35, 4; 9-16
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of various control techniques for motor-pump sets applied in selected water distribution systems
Autorzy:
Popenda, A.
Powiązania:
https://bibliotekanauki.pl/articles/1372738.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
elektrociepłownia
system dystrybucji wody
pompa
thermal-electric power station
water distribution system
pump
Opis:
The water distribution system applied in the thermal-electric power station EC Tychy SA is analyzed. The economical aspects of various control techniques for motor-pump sets in the aforementioned system are presented in the paper on the example of pumps working out of the cold season. The reasons of control losses occurring in the present system are depicted. The way of improvement of control effectiveness is proposed but unprofitability of the investment is also shown. A control of pumps by throttling and control by rotational speed changes are compared in the paper. It is shown that control by rotational speed changes causes similar losses like control by throttling if application of variable-speed technique is not preceded by appropriate adaptation of water distribution system, especially by adjustment of pump rated parameters.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2011, 4, 92; 97-101
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kohonen Artificial Networks for the Verification of the Diameters of Water-pipes
Autorzy:
Dawidowicz, Jacek
Czapczuk, Andrzej
Kruszyński, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/2069889.pdf
Data publikacji:
2021
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
water distribution system
hydraulic calculations
diameter selection
Kohonen Network
evaluation of calculation results
Opis:
The design of the water distribution system is inherently linked to the execution of calculations, which aim, among other things, to determine the flow rate through individual pipes and the selection of diameters at the appropriate speed. Each step in the calculations is followed by an evaluation of the results and, if necessary, a correction of the data and further calculations. It is up to the designer to analyse the accuracy of the calculation results and is time-consuming for large systems. In this article, a diagnostic method for the results of hydraulic calculations, based on Kohonen Network, which classifies nominal diameters [DN] on the basis of data, in the form of flows, has been proposed. After calculating the new variant of the water distribution system, the individual calculation sections are assigned to the neurons of the topological map of Kohonen Network drawn up for nominal diameters. By comparing the diameter used for the calculation, with the diameter obtained on the topological map, the accuracy of the chosen diameter can be assessed. The topological map, created as a result of labelling the neurons of the output layer of the Kohonen Network, graphically shows the position of the classified diameter, relative to those diameters with similar input values. The position of a given diameter, relative to other diameters, may suggest the need to change the diameter of the pipe.
Źródło:
Rocznik Ochrona Środowiska; 2021, 23; 835--844
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przyczyny zużycia pozostałego chloru wolnego w systemie dystrybucji wody
Causes underlying the free chlorine in the water distribution system
Autorzy:
Świderska-Bróż, M.
Wolska, M.
Powiązania:
https://bibliotekanauki.pl/articles/236508.pdf
Data publikacji:
2007
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
dystrybucja wody
chlor wolny
biofilm
zużycie chloru
water distribution system
free chlorine
chlorine consumption
Opis:
Omówiono czynniki wpływające na zużycie chloru wolnego w systemie dystrybucji wody, takie jak dezaktywacja mikroorganizmów, utlenianie organicznych i nieorganicznych substancji zredukowanych obecnych w wodzie i osadach (biofilm), jonizacja korodujących materiałów instalacyjnych i utlenianie produktów korozji, a także chlorowanie związków organicznych. Do opisu zmian zawartości chloru wolnego w systemie dystrybucji najczęściej stosuje się równanie kinetyczne reakcji pierwszego rzędu, a stała szybkości całkowitego zużycia chloru wolnego jest sumą stałych szybkości zużycia tego utleniacza w strumieniu wody oraz na powierzchni przewodów wodociągowych. Omówiono wpływ jakości wody wprowadzanej do sieci wodociągowej, rodzaju materiałów instalacyjnych i ich stanu technicznego i sanitarnego oraz warunków hydraulicznych panujących w systemie dystrybucji wody na zmniejszenie zawartości chloru wolnego w wodzie podczas jej transportu w sieci wodociągowej.
The factors that affect the free chlorine decay in the water distribution system are diverse. In this paper consideration is given to the deactivation of microorganisms, oxidation of organic and inorganic reduced substances that are present in the water and biofilm, ionization of corroding structural materials, oxidation of corrosion products, and chlorination of organic compounds. To describe the variations in the content of free chlorine in the water distribution system, use is made predominantly of the kinetic equation for a first-order reaction, and the rate constant of the total consumption of free chlorine is the sum of the rate constants of the consumption of this disinfectant in the water stream and on the pipe walls. The paper also addresses the problem of how the quality of the water entering the pipeline, the type and condition (both technical and sanitary) of the structural materials, and the hydraulic conditions in the water distribution system contribute to the decrease in the content of free chlorine in the water during transport in the pipeline.
Źródło:
Ochrona Środowiska; 2007, R. 29, nr 3, 3; 19-24
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Concept of Calculating the Water Distribution System as a Repeatable Process with Elements of Diagnostics Using Neural Modeling
Autorzy:
Dawidowicz, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/2174897.pdf
Data publikacji:
2022
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
water distribution system
hydraulic calculation
process diagnostics
evaluation of calculation results
artificial neural network
Opis:
Calculations of water distribution systems are most often performed many times because the correct solution from a technical point of view is rarely obtained after the first calculation run; hence, we can talk about a multistage calculation process. In connection with this, the calculation process of computer water distribution systems can be additionally supplemented with elements of process diagnostics. Diagnostic activities should be carried out using numerical algorithms, which can be a complement to classical hydraulic calculations of water distribution systems. The condition for reliable functioning of the diagnostic system formulated in this way is the efficient detection of computational irregularities. For this purpose, diagnostic problems were defined for the water pipes and the connection nodes in the water distribution system. The proposed diagnostic tests analyze the calculation results and indicate whether the solution is correct or, if irregularities are detected, suggest a way to solve the problem. Diagnostic tests are carried out using artificial neural networks.
Źródło:
Rocznik Ochrona Środowiska; 2022, 24; 493--504
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies