Wyświetlanie 1-5 z 5
Tytuł:
Determination of reliable concentrations of pollutants in raw wastewater based on different sampling methods
Wyznaczanie miarodajnych stężeń zanieczyszczeń w ściekach surowych w oparciu o różne metody poboru próbek
Autorzy:
Myszograj, S.
Sadecka, Z.
Qteishat, O.
Suchowska-Kisielewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/396193.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
sampling methods
raw sewage
wastewater treatment plant
metody poboru próbek
ścieki
analiza ścieków
oczyszczalnia ścieków
Opis:
The aim of this study was to check the extent to which the sampling method and the volume of sewage (size of the wastewater treatment plant) influence the determined daily average concentrations of pollution components. Within three days of dry weather, the composition of two raw sewage wastewater treatment plants was continuously monitored. The WWTPs were designed for the flow of 820 m3d and 51000 m3d, respectively. The concentrations of pollutants were measured in samples taken both in time-proportional and flow-proportional ways. The obtained values show the possibility of taking the samples mixed at equal time intervals and in proportion to the flow as reliable sources for design values of concentrations. The size of WWTP, i.e. the amount of investigated raw sewage, was of no significant importance to the obtained results regarding concentrations of pollutants.
Nowelizacja i dostosowywanie przepisów prawnych do wymagań UE wymusza na eksploatatorach oczyszczalni ścieków wykonywanie precyzyjnych pomiarów ilości i analiz składu fizyko-chemicznego ścieków. Postęp techniczny oraz bogata oferta producentów urządzeń umożliwia sprostanie tym wymaganiom. Jednak o przydatności wyników pomiarowych do projektowania oczyszczalni ścieków obok dokładności urządzeń pomiarowych decyduje fakt, czy próbkę ścieków można uznać za próbkę reprezentatywną. Często pomimo najnowocześniejszych urządzeń i wykwalifikowanego personelu wyniki badań nie mogą być traktowane wiarygodnie. W artykule na podstawie pomiarów ilości i analiz składu ścieków surowych zweryfikowano w jakim stopniu metoda poboru próbek oraz ilość dopływających ścieków (wielkość oczyszczalni ścieków) wpływa na wartość wyznaczonych średniodobowych stężeń wskaźników zanieczyszczeń. W ciągu trzech dób w pogodzie suchej przeprowadzono ciągły monitoring składu ścieków surowych w oczyszczalniach zaprojektowanych na przepływ 820 m3d (OŚ1) i 51000 m3d (OŚ2). W próbkach zbieranych czasowo-proporcjonalnie i przepływowo-proporcjonalnie wyznaczono stężenia miarodajne wskaźników zanieczyszczeń. Uzyskane wartości wskazują na możliwości przyjmowania do projektowania stężeń miarodajnych wyznaczonych w próbkach zlewanych w jednakowych interwałach czasowych, jak i proporcjonalnie do przepływu. Nie stwierdzono również istotnego wpływu wielkości oczyszczalni, a tym samym nierównomierności dopływu ścieków surowych na obliczone wartości stężeń wskaźników zanieczyszczeń.
Źródło:
Civil and Environmental Engineering Reports; 2013, 10; 99-107
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ ścieków oczyszczonych odprowadzanych z Oczyszczalni Ścieków w Tucholi na jakość wody w strudze Kicz
The influence of treated sewage discharged from wastewater treatment plant in tuchola on water quality of Kicz stream
Autorzy:
Lewandowska-Robak, M.
Górski, Ł.
Kowalkowski, T.
Dąbkowska-Naskręt, H.
Miesikowska, I.
Powiązania:
https://bibliotekanauki.pl/articles/296919.pdf
Data publikacji:
2011
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
zanieczyszczenia wody
analiza jonów nieorganicznych
oczyszczalnia ścieków
analiza statystyczna
water pollution
inorganic ions analysis
wastewater treatment plant
statistic analysis
Opis:
Tuchola jest największym miastem położonym w Borach Tucholskich dużym kompleksie lasów sosnowych, wchodzącym w skład obszarów Natura 2000. W 1992 r. w Tucholi zbudowano oczyszczalnię ścieków typu mechaniczno-biologicznego z podwyższonym usuwaniem związków biogennych, odbierającą ścieki z terenu miasta i gminy Tuchola oraz gmin Cekcyn i Kęsowo. Od tamtej pory struga Kicz (zlewnia rzeki Brdy), odbierająca wcześniej ścieki nieoczyszczone, jest odbiornikiem ścieków oczyszczonych i jakość jej wód wzrosła. Celem badań była analiza wpływu ścieków oczyszczonych odprowadzanych z oczyszczalni ścieków do strugi Kicz na jakość wody tej strugi. W okresie od listopada 2008 roku do czerwca 2009 roku pobierano raz w miesiącu próbki wody ze strugi Kicz powyżej i poniżej ujścia ścieków oraz próbki ścieków nieoczyszczonych i oczyszczonych. Stwierdzono wysoką, choć niewystarczającą efektywność procesu oczyszczania ścieków w Oczyszczalni Ścieków w Tucholi. Na podstawie analizy statystycznej za pomocą testu kolejności par Wilcoxona stwierdzono istotnie gorszą jakość wody w strudze poniżej ujścia ścieków pod względem BZT5, azotanów(III) i (V) oraz chlorków. Zrzut ścieków nie miał natomiast istotnego wpływu na inne parametry jakości wody, tj. pH, ChZT, azot amonowy, fosforany i zawiesinę ogólną. Nadal niezbędne są działania prowadzące do poprawy jakości wody w strudze Kicz, przy czym w szczególności poprawy wymaga wartość ChZT.
Tuchola (14,000 inhabitants) is the biggest town in Bory Tucholskie one of the largest pine forest complex in Poland, which is at the same time a part of Natura 2000. There are 4 natural landscape parks and 17 nature reserves in Bory Tucholskie. Until 1992 untreated sewage from Tuchola was discharged to Kicz stream (within Brda catchment), thus the values of water quality indicators in the stream significantly exceeded the national requirements (among others BOD5, phosphates, total phosphorus, total suspended solids, bacteriological indices). In 1992 a Wastewater Treatment Plant (WWTP) in Tuchola was built, which was in accordance with ecological politics of Poland, aiming among others at enhancing water quality. WWTP in Tuchola is of mechanical-biological type with enhanced removal of biogenic compounds and it collects sewage from Tuchola town and commune areas, and from Cekcyn and Kęsowo communes. Despite the fact that since 1992 water quality in Kicz and Brda has significantly increased, in 2000 the values of some water quality indicators were still too high. The aim of the research was to analyze the influence of treated sewage discharged from WWTP in Tuchola to Kicz stream on the stream water quality. The efficiency of wastewater treatment process in WWTP in Tuchola was also evaluated, and water in Kicz stream was classified as adequate quality class. In the period from November 2008 to June 2009 once a month samples of surface water from Kicz stream above and below sewage outlet were taken, as well as samples of untreated and treated sewage from WWTP in Tuchola. On the same day, the samples were analyzed for various water quality indices, i.e. COD, BOD5, ammonium nitrogen, nitrates(V) and (III), total Kjeldahl nitrogen, ortophosphates, chlorides, total suspended solids and pH. Based on calculated reduction coefficients it was found that in case of BOD5, COD, total suspended solids, phosphates, ammonium nitrogen and total nitrogen the efficiency of WWTP work is high. However the total nitrogen concentration in treated sewage was slightly above the values required. By comparing the results of analyzes of water samples from Kicz stream above and below the treated sewage outlet with the use of non-parametric Wilcoxon signed-rank paired test, it was found that the water quality is significantly worse below the sewage outlet in case of BOD5, nitrates(III) and (V), and chlorides. Values of pH, COD, ammonium nitrogen, phosphates and total suspended solids did not differ significantly in water above and below the sewage outlet. The obtained results of water analyzes in Kicz stream indicate that in case of COD the water quality is poor. BOD5 value corresponds to II quality class, whereas the concentration of nitrates(V) and ammonium nitrogen water on the border of I//II class. With respect to pH, chlorides and total suspended solids water of Kicz stream is of very good quality (I class). Thus, in spite of significant increase in water quality of Kicz stream after the rise of WWTP, activities are still needed to ensure more efficient work of WWTP.
Źródło:
Inżynieria i Ochrona Środowiska; 2011, 14, 3; 209-221
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characteristic of Fulvic Acids Extracted from the Wastewater by Different Methods
Właściwości kwasów fulwowych wyekstrahowanych ze ścieków za pomocą różnych metod
Autorzy:
Łomińska-Płatek, Dominika
Anielak, Anna M.
Powiązania:
https://bibliotekanauki.pl/articles/1811776.pdf
Data publikacji:
2019
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
substancje humusowe
kwasy fulwowe
oczyszczalnia ścieków
ekstrakcja kwasów fulwowych
analiza elementarna
charakterystyka spektroskopowa
humic substances
fulvic acids
wastewater treatment plant
extraction of fulvic acids
elemental analysis
spectroscopic characteristics
Opis:
Fulvic acids (FAs) were isolated from the wastewater by two different extraction methods. The first one with ammonia water (NH4OH) and the second with an ion exchange using a hydrophobic ion exchanger and desorbed using aqueous sodium hydroxide (NaOH). The samples were collected directly from the primary and secondary effluents at the WWTP and the obtained results were averaged. The WWTP treats mainly wastewater from individual users and industrial plants. The selected plant comprises mechanical and biological wastewater trains as well as sludge processing and biogas trains. The plant works as a three-stage Bardenpho system and operates five identical biological reactors. The main objective of the study was to conduct a mass balance and assess the amount of FAs in the primary and secondary effluent. The extracted acids were subjected to an analysis of their elemental composition, trace elements content and IR spectrum analysis. Based on elemental composition, atomic ratios: C/O, C/H, C/N and O/H, as well as a degree of inside oxidation, have been determined. The studies have shown that the highest amount of FAs was extracted from the primary effluent with the NaOH method and in the secondary effluent less inorganic impurities were removed. Based on the results, it can be concluded that extraction with NaOH solution and a two-stage ion exchange process (hydrophobic ion-cation exchanger-H+) reduces the degree of internal oxidation of FAs. Soluble HSs extracted from the primary effluent had a higher level of humification in both methods. Comparing an elemental composition of four samples, it can be noticed that a structure of FAs extracted with the same method is very similar for both primary and secondary effluent, but when two different methods are compared some small differences can be found. Based on the research, it can be stated that the WWTP discharged less FAs compared to the input pollution load, regardless of the extraction method used.
Kwasy fulwowe (KF) zostały wyekstrahowane ze ścieków z wykorzystaniem różnych metod ekstrakcji. Pierwsza metoda z użyciem wody amoniakalnej (NH4OH) natomiast druga oparta na procesie wymiany jonowej na hydrofobowym wymienniku jonitowym przy użyciu wodnego roztworu wodorotlenku sodu (NaOH). Próbki zostały pobrane bezpośrednio z mechanicznie oraz biologicznie oczyszczonych ścieków z wybranej oczyszczalni ścieków a podane wyniki zostały uśrednione. Oczyszczalnia ścieków (OŚ) odprowadza głównie ścieki od indywidualnych użytkowników, ale i również z zakładów przemysłowych. Wybrana OŚ składa się z części mechanicznej i biologicznej oraz osadowej i gazowej. W skład części mechanicznej wchodzą: kraty rzadkie, pompownia, kraty gęste, piaskowniki, osadniki wstępne, pompownia II stopnia. Część biologiczna składa się z reaktorów i osadników wtórnych. OŚ pracuje w układzie 3 stopniowym Bardenpho i składa się z 5 identycznych biologicznych reaktorów. Z kolei część osadowa to: zagęszczarki mechaniczne, stacja dezintegracji osadu, zagęszczanie grawitacyjne, prasy taśmowe, wydzielone komory fermentacji oraz ciąg generowania gazu. Oczyszczone ścieki trafiają do rzeki poprzez wylot kaskadowy. Głównym celem badań był bilans masy oraz określenie ilości KF w mechanicznie i biologicznie oczyszczonych ściekach. Wyekstrahowane KF poddano analizie ich składu elementarnego, zawartości pierwiastków oraz przeprowadzono badanie absorbancji widma IR w podczerwieni. Na podstawie składu elementarnego określono ilorazy atomowe: C/O, C/H, C/N i O/H oraz wyliczono stopień utlenienia wewnętrznego. Wyniki badań pokazały, że największe stężenie KF wyekstrahowano przy użyciu metody z wykorzystaniem NaOH z mechanicznie oczyszczonych ścieków. Przy użyciu tej samej metody mniej zanieczyszczeń nieorganicznych usunięto z KF wyekstrahowanych ze ścieków biologicznie oczyszczonych. Na podstawie wyników badań można wnioskować, że ekstrakcja KF z użyciem roztworu NaOH podczas dwu stopniowej wymiany jonowej (hydrofobowy wymiennik jonitowy H+) zmniejsza stopień utlenienia wewnętrznego (ω). KF wyekstrahowane ze ścieków mechanicznie oczyszczonych miały wyższy stopień humifikacji, w obu metodach. Porównując skład elementarny czterech próbek można zauważyć, że budowa KF wyekstrahowanych tą samą metodą jest bardzo zbliżona, ale kiedy porówna się ze sobą KF wyekstrahowane z tych samych ścieków jednak różnymi metodami zauważalne są małe różnice. Badania wykazały, że wybrana OŚ odprowadza mniejszy ładunek KF w porównaniu do wprowadzanego, bez względu na rodzaj zastosowanej metody ekstrakcji.
Źródło:
Rocznik Ochrona Środowiska; 2019, Tom 21, cz. 1; 184-200
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stan awaryjny reaktorów biologicznych A i B znajdujących się na oczyszczalni ścieków w Wałczu jako skutek popełnionych błędów przy ich projekcie i użytkowaniu
Emergency state of biological reactors located in the area of sewage treatment plant in Walcz as a result of commited faults during their projection process and expliotation
Autorzy:
Przybyłowicz, E.
Pikos, M.
Powiązania:
https://bibliotekanauki.pl/articles/160299.pdf
Data publikacji:
2017
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
oczyszczalnia ścieków
zbiornik na ścieki
reaktor biologiczny
zbiornik żelbetowy
stan techniczny
pęknięcie
destrukcja betonu
analiza przyczyn
wastewater treatment plant
sewage tank
biological reactor
reinforced concrete tank
technical condition
crack
concrete destruction
causes analysis
Opis:
W pracy omówiono uszkodzenia i przyczyny, które doprowadziły do stanu awaryjnego dwóch reaktorów biologicznych na remontowanej oczyszczalni ścieków w Wałczu. Powstałe uszkodzenia ścian i den zbiorników stworzyły zagrożenie skażenia środowiska ściekami komunalnymi. Bezpośrednią przyczyną tego stanu były popełnione błędy na etapie projektowania konstrukcji zbiorników bez zachowania odpowiednich zasad odnośnie posadowienia, rozwiązań dylatacji, zbrojenia i wymagań co do jakości betonu. W reaktorach nie zastosowano odpowiednich powłok ochronnych na betonie, co w połączeniu ze złą jakością betonu doprowadziło do całkowitej degradacji obiektów i podjęcia decyzji o ich rozbiórce z uwagi na nieopłacalny remont.
Present paper discusses the damages and causes that led to the emergency condition of two biological reactors on the renovated sewage treatment plant in Walcz. Resulting damages of walls and bottom of tanks caused a risk of contamination of the environment with municipal sewage. The direct cause of this condition was mistakes/errors made at the stage of structural design of the tanks without maintaining proper rules of foundation process, construction of dilation, propositions of suitable reinforcements and concrete quality requirements. In the reactors appropriate protective coatings on a concrete were not used, which, in combination with poor quality of concrete, led to complete degradation of objects and decided to demolish them due to unprofitable repairs.
Źródło:
Przegląd Budowlany; 2017, 88, 9; 86-88
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Błędy projektowe i wykonawcze jako przyczyna uszkodzeń dwóch zbiorników – komór napowietrzania ścieków znajdujących się na terenie oczyszczalni ścieków w Grodzisku Wielkopolskim
Design and building process mistakes as the cause of damages of two tanks – aeration chambers of sewage located on the area of sewage treatment plant in Grodzisk Wielkopolski
Autorzy:
Przybyłowicz, E.
Pikos, M.
Powiązania:
https://bibliotekanauki.pl/articles/161615.pdf
Data publikacji:
2017
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
oczyszczalnia ścieków
zbiornik na ścieki
komora napowietrzania
konstrukcja żelbetowa
stan techniczny
spękanie ścian
analiza przyczyn
błąd projektowania
błąd wykonawstwa
wastewater treatment plant
sewage tank
aeration chamber
reinforced concrete structure
technical condition
wall cracking
causes analysis
design fault
execution fault
Opis:
W pracy omówiono przyczyny uszkodzeń ścian dwóch zbiorników – komór napowietrzania ścieków znajdujących się na terenie modernizowanej oczyszczalni ścieków w Grodzisku Wlkp. Zasadniczą przyczyną powstałych uszkodzeń było niewłaściwe rozmieszczenie dylatacji w ścianach zbiorników, zbyt małe zbrojenie poziome ścian niezabezpieczające ich przed wpływem skurczu betonu i zmian temperatury, zła jakość betonu oraz prowadzone roboty budowlane związane z budową w pobliżu nowego zbiornika. Po przeanalizowaniu kosztów naprawy zbiorników stwierdzono, że najbardziej racjonalnym rozwiązaniem będzie ich rozbiórka i budowa nowych obiektów z zachowaniem zasad współczesnej wiedzy technicznej, a do czasu podjęcia tych prac doraźne uszczelnienie spękanych ścian i ich lokalne wzmocnienie.
Present paper discusses the causes of damage of walls of two tanks – aeration chambers of wastewater located in the area of modernized sewage treatment plant in Grodzisk Wlkp. The main cause of the damage was improper location of dilatation in the tank walls, too low reinforcement of horizontal walls not protect them against the effect of concrete shrinkage and temperature changes, bad concrete quality and building work carried out near the new tank. After analyzing the costs of repairing tanks, it was found that the most rational solution would be their dismantling and construction of new facilities according to principles of modern technical knowledge. The temporary sealing of cracked walls and their local reinforcement will be applied until repair works are done.
Źródło:
Przegląd Budowlany; 2017, 88, 9; 89-92
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies