Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "wastewater treatment efficiency" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Evaluation of wastewater treatment efficiency in Wolbrom
Autorzy:
Gawron, M.
Łukasiewicz, M.
Malinowski, M.
Salamon, J.
Powiązania:
https://bibliotekanauki.pl/articles/101059.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
wastewater treatment plant
efficiency
wastewater treatment
Opis:
The study was conducted to assess the effectiveness of wastewater treatment at the municipal wastewater treatment plant in Wolbrom, to which predominantly domestic wastewater and industrial sewage flow. The assessment was made based on the analysis of the physical and chemical research results of raw and treated wastewater. The research was carried out in the period from January 2014 to December 2014. To perform the analysis of the treatment plant efficiency, four indicators of wastewater pollutants such as BOD5 , COD, total nitrogen and total phosphorus were selected for further investigation. For each of the indicators degrees of reduction and coefficients of treatment plant operational reliability were calculated. The calculated degrees of reduction for each of the indicators were high and amounted to 99.0% for BOD5 , 95.2% for COD, 91.0% for total nitrogen and 91.6%. for total phosphorus. These results prove the effective reduction in the amount of pollutants. The determined coefficients of treatment plant operational reliability were at a low level: BOD5 - 0.27, COD - 0.44, total nitrogen - 0.33 and total phosphorus - 0.53. The conducted analyses prove the effective operation of the treatment plant, which was confirmed by high efficiency of pollutants removal.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, IV/4; 1889-1897
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wybranych parametrów pracy oczyszczalni w technologii „Lemna” na przykładzie gminnej oczyszczalni ścieków w Chmielniku (woj. Podkarpackie)
Analysis of selected operational parameters of „Lemna” treatment plant, on the example of the MWWTP in Chmielnik (Poland, Subcarpathian Province)
Autorzy:
Jurczyk, Ł
Koc-Jurczyk, J.
Winiarska, K.
Powiązania:
https://bibliotekanauki.pl/articles/400273.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ścieki komunalne
Lemna
oczyszczanie ścieków
efektywność oczyszczania
wskaźnik niezawodności
municipal wastewater
wastewater treatment
treatment efficiency
reliability index
Opis:
W pracy przedstawiono analizę pracy gminnej oczyszczalni ścieków typu „Lemna”, a badaniami objęto okres siedmiu lat (2009–2015). Badano sprawność usuwania takich wskaźników jak BZT5, ChZT oraz zawiesiny ogólnej. Pomimo bardzo wysokiej zmienności stężeń w ściekach dopływających, we wszystkich przypadkach stwierdzono wysoką skuteczność i niezawodność działania instalacji. Średnia efektywność usuwania zanieczyszczeń organicznych i zawiesiny ogólnej wyniosła 94,23% BZT5, 82,55% ChZT oraz 76% zawiesiny ogólnej i była dodatnio skorelowana z obciążeniem tymi parametrami ścieków surowych.
In this paper the analysis of „Lemna” municipal treatment plant performance is reported, the study covered a period of seven years (2009–2015). The efficiency of removal of such indicators as BOD5, COD and total suspended solids were examined. Despite the very high variability of concentrations in raw wastewater, high efficiency and reliability of the installation was found in all cases. The average removal efficiency of organic compounds and total solids was 94.23% for BOD5, 82.55% for COD and 76% for total suspended solids; moreover, it was positively correlated with the load on these parameters in inflow.
Źródło:
Inżynieria Ekologiczna; 2017, 18, 5; 10-17
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrafiltracyjne doczyszczanie odpływów z oczyszczalni ścieków komunalnych
The municipal sewage treatment plant effluent polishing in ultrafiltration
Autorzy:
Dudziak, M.
Kudlek, E.
Łaskawiec, E.
Felis, E.
Kowalska, K.
Garbaczewski, L.
Powiązania:
https://bibliotekanauki.pl/articles/400811.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ultrafiltracja
oczyszczanie ścieków
efektywność procesu
ultrafiltration
wastewater treatment
efficiency of the process
Opis:
Odpływ z oczyszczalni ścieków komunalnych poddano porównawczo oczyszczaniu w procesie ultrafiltracji z wykorzystaniem membrany ceramicznej i polimerowej. Filtrację prowadzono w systemie cross-flow w warunkach ciśnienia transmembranowego procesu 0,1 MPa – membrana ceramiczna i 0,2 MPa – membrana polimerowa oraz w temperaturze 20°C. Skuteczność procesu oceniono wykonując różne analizy fizyko-chemiczne (m.in. pH, mętność, barwa, absorbancja, OWO i indeks fenolowy). Włączono również ocenę toksykologiczną (stosując jako organizm wskaźnikowy bakterie bioluminescencyjne Aliivibrio fischeri) oraz mikrobiologiczną badanych próbek wodnych. Podczas filtracji badano wydajność hydrauliczną membran. Określono, że skuteczność procesu zależy od warunków prowadzenia filtracji membranowej, przy czym lepsze efekty usunięcia zanieczyszczeń organicznych odnotowano w przypadku membrany polimerowej niż ceramicznej. Jednak membrana polimerowa w porównaniu do membrany ceramicznej była bardziej podatna na zjawisko blokowania porów powodujące obniżenie wydajności hydraulicznej. Bez względu na rodzaj membrany permeaty nie były toksyczne jak i nie zawierały mikroorganizmów.
The effluent from the municipal sewage treatment plant was comparatively treated in the ultrafiltration process using ceramic and polymer membranes. Filtration was carried out in the cross-flow system under the conditions of the transmembrane process pressure of 0.1 MPa in the case of the ceramic membrane and 0.2 MPa with the polymer membrane, at a temperature of 20°C. The effectiveness of the process has been assessed by means of various physical and chemical analyses (pH, turbidity, color, absorbance, TOC and phenol index). The toxicological assessment (by applying the bioluminescent bacteria Aliivibrio fischeri as an indicator organism) and microbiological assessment of tested samples were included. The hydraulic efficiency of membranes was studied during filtration. Is was specified that the efficiency of the process depends on the conditions of membrane filtration, wherein the better effects of the removal of organic pollutants have been noted in the case of polymer membrane than with the ceramic membrane. However, the polymer membrane, in comparison to the ceramic membrane, was more susceptible to pore blocking, which caused the reduction of hydraulic efficiency. Regardless of the type of membrane, the permeates were not toxic and did not contain microorganisms.
Źródło:
Inżynieria Ekologiczna; 2017, 18, 4; 40-46
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of gas holdup on the efficiency of cyclonic-static microbubble flotation column for oily wastewater treatment
Autorzy:
Ning, K.
Huang, G.
Xu, H.
Wu, L.
Li, X.
Wang, Y.
Powiązania:
https://bibliotekanauki.pl/articles/208139.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
bubble columns
efficiency
flotation
wastewater treatment
oil water separation
kolumna flotacyjna
efektywność
flotacja
oczyszczanie ścieków
separacja wody
Opis:
A cyclonic-static microbubble flotation column of a novel construction was used in oil-water separation fields and has high efficiency for oil-water separation. The gas holdup is a key parameter for the evaluation of the performance of a flotation column. The gas holdup, closely related to the bubble size, bubble velocity and superficial gas velocity, is one of the most important parameters characterizing the hydrodynamics of a bubble column. The effect of gas holdup in a cyclonic-static microbubble flotation column was investigated. In addition, several operating parameters such as the circulating pressure, superficial gas velocity, and frother consumption were also investigated. The gas holdup was positively correlated to the superficial gas velocity. The gas holdup of clean water and oil wastewater increased along with the increase of the frother consumption. The separation mechanism of cyclonic-static microbubble flotation column was analyzed.
Źródło:
Environment Protection Engineering; 2018, 44, 2; 5-17
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Accurate oxygen transfer efficiency measurements by off-gas method - tank coverage dilemma
Pomiar sprawności transferu tlenu metodą off-gas - problem stopnia pokrycia reaktora
Autorzy:
Muszyński-Huhajło, M.
Janiak, K.
Powiązania:
https://bibliotekanauki.pl/articles/126006.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
wastewater treatment
aeration
oxygen transfer efficiency
off-gas method
oczyszczanie ścieków
napowietrzanie
stopień wykorzystania tlenu
metoda off-gas
Opis:
The off-gas method is one of two primary aeration efficiency examination methods. In off-gas method, exhaust air from aeration tank is collected by a floating hood and conveyed to a measurement module. In this part of the installation, gas flow is measured, collected air is dried, stripped of CO2 and subsequently oxygen concentration is measured. The hood area is usually few square meters or even less and is a very small part of the aeration tank area. The main advantage of the off-gas method is that it offers measurement without disturbances to reactor routine work, which are necessary in the case of alternative, absorption method. Thereby, the off-gas method can be used in any circumstances and is free from uncertainty about the influence of reactor disturbances on the obtained results. However, a question remains about the number of measurement points required to obtain representative results for the whole reactor. According to The Environmental Protection Agency (EPA) guidelines, coverage of 2% of the tank area is sufficient, but this number seems insufficient. This article presents an analysis of the influence of tank coverage on the obtained oxygen transfer efficiency values. The presented analysis is based on real data.
Pomiary off-gas są jedną z dwóch dostępnych metod określenia stopnia wykorzystania tlenu w systemach napowietrzania oczyszczalni ścieków. Największą zaletą prezentowanej metody jest możliwość prowadzenia pomiarów w warunkach procesowych bez ingerencji w funkcjonowanie układu oczyszczania ścieków. Na podstawie danych zebranych podczas pomiarów wykonanych na jednej z komunalnych oczyszczalni ścieków w Polsce przeprowadzono analizę wpływu ilości punktów pomiarowych na uzyskiwane wartości stopnia wykorzystania tlenu. Analizę przeprowadzono, wykorzystując wyniki uzyskane z pomiarów zapewniających dużo wyższe pokrycie powierzchni reaktora (odpowiednio 12 i 8,8%) względem wytycznych literaturowych mówiących o 2% stopniu pokrycia reaktora.
Źródło:
Proceedings of ECOpole; 2017, 11, 1; 45-53
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency of organic substance removal in a hybrid sand filter with horizontal flow
Efekty usuwania substancji organicznej w hybrydowych filtrach piaskowych z przepływem poziomym
Autorzy:
Jóźwiakowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/292933.pdf
Data publikacji:
2017
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
BOD5
COD
efficiency
horizontal flow
sand filter
wastewater treatment
BZT5
ChZT
efektywność oczyszczania ścieków
filtr piaskowy
przepływ poziomy
Opis:
The paper presents the results of the research about the efficiency of organic substance removal in a hybrid sand filter. The investigations were carried out on a model wastewater treatment plant consisting of a preliminary sedimentation tank and two sand filter with a horizontal flow of wastewater (aerobic and anaerobic beds). The efficiency of BOD5 and COD removal was analysed for different wastewater hydraulic load levels: 0.72; 1.08; 1.44 dm3·d–1. The best efficiency of BOD5 and COD removal was obtained when the hydraulic load level was 1.08 dm3·d–1, respectively 83.8 and 72.3%. The average values of BOD5 and COD in the treated wastewater were significantly higher than the values deemed acceptable by relevant regulations in Poland. Based on the studies in the analyzed case, it was found that, sand filters with horizontal flow, do not guarantee high effluent treatment effect of typical household wastewater. In order to obtain a better efficiency of organic substance removal in a hybrid sand filter wastewater need to be oxygenate before being carried to these systems.
W pracy zaprezentowano wyniki dotyczące efektywności usuwania substancji organicznej w hybrydowych filtrach piaskowych. Badania prowadzono w modelowej oczyszczalni ścieków składającej się z osadnika wstępnego i dwóch filtrów piaskowych z poziomym przepływem. Efektywność zmniejszania BZT5 i ChZT była analizowana w warunkach różnego obciążenia hydraulicznego ściekami: 0,72; 1,08; 1,44 dm3·d–1. Najlepsze efekty obniżania BZT5 i ChZT uzyskano w warunkach obciążenia hydraulicznego na poziomie 1,08 dm3·d–1, odpowiednio 83,8 i 72,3%. Średnie wartości BZT5 i ChZT w oczyszczonych ściekach były zazwyczaj większe niż dopuszczalne w odpowiednich przepisach w Polsce. Na podstawie badań w analizowanym przypadku stwierdzono, że filtry piaskowe o przepływie poziomym nie dają gwarancji wysokiej sprawności oczyszczania ścieków bytowych. W celu uzyskania lepszych efektów eliminacji substancji organicznej w filtrach piaskowych konieczne jest napowietrzanie ścieków przed doprowadzeniem ich do tych systemów.
Źródło:
Journal of Water and Land Development; 2017, 35; 95-100
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies