Tytuł:
Sorption of organic compounds by organo-zeolites
Autorzy:
Wołowiec, M.
Muir, B.
Bajda, T.
Powiązania:
https://bibliotekanauki.pl/articles/184432.pdf
Data publikacji:
2016
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
water system
human health
wastewater
Opis:
Organic compounds such as BTEX and PAHs are one of the most common contaminants in water system. These contaminants would take decades to degrade and they have harmful effects on human health (Qin et al. 2008). Several treatment methods have been developed to remove those contaminants from industrial wastewater. They include ion-exchange, filtration, adsorption and the use of various types of sorbents for example zeolites (Kibazohi et al. 2004, Mathur et al. 2007, Aivaliotiet al. 2012, Almeida et al. 2012). Natural clinoptilolite (Cp) from the Bystré deposit in Slovakia and zeolite Na-X synthesized from fly ash has been modified with a hexadecyltrimethyl ammonium bromide (HDTMA) in amounts of 1.0 and 2.0 of external cation exchange capacity (ECEC) of the zeolites (Szala et al. 2013). The sorption properties of unmodified zeolites and organo-zeolites in terms of aqueous solutions of benzene, ethylobenzene, toluene, p-xylene (BTEX) and their mixtures as well as anthracene, naphthalene, benzo[a]pyrene, dibenzo[a,h]anthracene (PAHs) and their mixtures at different concentrations were evaluated. The results showed that the modification of the zeolite Na-X and Cp with HDTMA improves the sorption properties. Modification in the amount of 1.0 ECEC proved to be the best in terms of p-xylene, anthracene, naphthalene, benzo[a]pyrene, dibenzo[a,h]anthracene. On the other hand benzene, ethylobenzene and toluene were adsorbed the most effectively by 2.0 ECEC modification of Na-X and Cp. Based on experimental data, the removal efficiencies for BTEX follows the order: p-xylene > toluene > benzene > ethylobenzene, for POHs: dibenzo[a,h]anthracene > benzo[a] pyrene > anthracene > naphthalene. P-xylene and naphtalene were adsorbed in the greatest quantity and benzene and anthracene in the lowest quantity from the mixtures of BTEX and PAHs, respectively. The sorption efficiency depends on the physicochemical properties of the organic compounds (dipole moment, molar mass, molecule structure and the time of the sorption process) as well as natural Cp and synthetic zeolite Na-X properties, such as Si/Al ratio, texture parameters and external cation exchange capacity. With an increasing concentration of the hydrocarbons in the solution the sorption capacity increases (Szala et al. 2015). Natural Cp is a better sorbent than synthetic zeolite Na-X in case of BTEX sorption, while PAHs are adsorbed more effectively by zeolite Na-X and its modifications. The mechanism of the sorption consists on the dissolving of the organic compounds into the organic layer of the surfactant (on the zeolites’ surface) as well as on the organic compounds’ penetration into the mesopores.
Źródło:
Geology, Geophysics and Environment; 2016, 42, 1; 139-140
2299-8004
2353-0790
Pojawia się w:
Geology, Geophysics and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the Proportion of Incidental Water in Annual Wastewater Inflows to a Selected Treatment Plant During a 15-year Observation Period
Autorzy:
Kaczor, Grzegorz
Cupak, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/1955390.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
sewerage system
wastewater
incidental water
Opis:
The main aim of the study was to determine whether the amount and share of incidental water in wastewater inflows to the wastewater treatment plant increased with the age and development of the sewage system. The object of the study is a small sewerage system located in southern Poland, in the Lesser Poland Province, 15 km northeast of the Kraków city. The analysis of a 15-year observation series of daily wastewater flows, from 01.01.1994 to 31.12.2018, allowed a reliable assessment of the actions taken by the sewage system operator to reduce the sources of incidental water inflow to the sewage network. The study showed that the percentage share of incidental waters in the annual wastewater inflow to the analysed treatment plant decreased from 35.9% in 2004 to 8.4% in 2018. This reduction should be treated as a success of the remedial actions of the sewage system operator. However, the study showed at the same time that in 2017 alone, 56 709 m3 of incidental water flowed into the analysed sewerage system, compared to 166 075 m3 of wastewater. A similar case was repeated in 2013, when 53 060 m3 of incidental water and 132 860 m3 of real wastewater flowed into the treatment plant. These cases show that all remedial measures by the network operator are still insufficient when heavy precipitation occurs in a given year for a long period of time.
Źródło:
Journal of Ecological Engineering; 2021, 22, 7; 204-211
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ lokalizacji oczyszczalni na temperaturę dopływających do niej ścieków
Influence of treatment plant location on temperature of inflowing sewage
Autorzy:
Kaczor, G.
Bugajski, P.
Chmielowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/101199.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
oczyszczalnia ścieków
ścieki
kanalizacja
temperatura ścieków
wastewater treatment plant
wastewater
sewage system
wastewater temperature
Opis:
Celem przeprowadzonych badań było uzyskanie wiedzy, jak umiejscowienie oczyszczalni względem zlewni kanalizacyjnej wpływa na temperaturę dopływających do niej ścieków. Analizą objęto cztery systemy kanalizacyjne, różniące się długością kolektora tranzytowego pomiędzy oczyszczalnią a zabudowaniami mieszkalnymi, w których wytwarzane były ścieki bytowe. W badanych systemach kanalizacyjnych ścieki odprowadzane były do oczyszczalni o przepustowości hydraulicznej od 100 do 300 m3·d-1, charakteryzujących się liczbą RLM nie większą niż 2000. Pomiary temperatury ścieków odpływających z kanalizacji oraz powietrza atmosferycznego, w analizowanym roku 2012, prowadzono w sposób ciągły, z interwałem 1 godzinnym, za pomocą czujników rezystancyjnych połączonych z rejestratorami danych. Przeprowadzone badania wykazały, że odległość oczyszczalni od zlewni kanalizacyjnej wywiera istotny wpływ na temperaturę ścieków odpływających z sieci kanalizacyjnej. W okresie zimowym średnia dobowa temperatura ścieków odpływających z kolektorów tranzytowych o długości od 300 do 600 m była niższa nawet o blisko 3ºC, natomiast w okresie letnim aż o 8ºC, w porównaniu do kolektorów tranzytowych o długości nieprzekraczającej 10 m. Wykazano ponadto, że na temperaturę ścieków dopływających do oczyszczalni, oprócz długości kolektora tranzytowego, istotnie wpływa także natężenie przepływu ścieków. Przy wzroście natężenia odpływu ścieków z kanalizacji o 100%, ich temperatura może wzrosnąć w okresie zimowym o 1ºC, natomiast w letnim o 3ºC. W przypadku sieci kanalizacyjnych zakończonych długimi kolektorami tranzytowymi, niekorzystnemu skróceniu ulega czas trwania temperatury ścieków optymalnej w aspekcie usuwania związków biogennych, a przy tym jednocześnie wydłuża się czas trwania temperatury ścieków niekorzystnej dla ich biologicznego oczyszczania.
The aim of the research was to get the expertise, how location of wastewater treatment plant to basin of sewage system influences the temperature of inflowing wastewater. The analysis included four sewage systems, which are different for the sake of length of transit canal between treatment plant and residential buildings, in which domestic sewage was produced. In analysed systems sewage flew into the treatment plants with hydraulic capacity range from 100 to 300 m3·d-1, and with population equivalent less than 2000. Measurements of temperature of air and wastewater outflowing from sewage system, in analysed year 2012, were conducted continuously, with 1 hour interval, with use resistance sensors connected with data recorder. The research showed, that the distance of treatment plant to basin of sewage system has a significant impact on wastewater temperature outflowing from sewage system. In winter period mean daily wastewater temperature outflowing from transit manifolds with length from 300 to 600 m was lower even about 3ºC, but in summer period up to 8ºC, in comparison to transit manifolds with length less than 10 m. Moreover, it was proved that, apart from length of transit manifold, also intensity of wastewater flow has a significant impact on wastewater temperature flowing into the treatment plant. With increase of intensity of wastewater flow about 100%, its temperature can increase in winter period about 1ºC, and about 3ºC in summer period. In case of sewage systems ended with long transit manifold, the duration time of optimal sewage temperature in terms of biogenic compounds removal is unfavourable reduced, and at the same time the duration time of wastewater temperature unfavourable for its biological treatment is extended.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, II/2; 615-626
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Providing of resource saving in Danube rice irrigation systems based on reuse of drainage water and wastewater
Oszczędzanie zasobów w systemach nawadniania pól ryżowych w dolinie Dunaju wynikające z ponownego wykorzystania wody drenażowej i ścieków
Autorzy:
Rokochynskiy, A.
Turcheniuk, V.
Volk, P.
Prykhodko, N.
Frolenkova, N.
Powiązania:
https://bibliotekanauki.pl/articles/2083877.pdf
Data publikacji:
2020
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
drainage water
wastewater
rice irrigation system
reuse
Opis:
Questions of reuse of drainage water and wastewater of rice systems on the example of rice irrigation systems are determined. The technological scheme, which saves water and energy resources during the irrigation of crops in the rice system, is proposed. Calculations of economic efficiency of water circulation technology in the Danube rice irrigation systems (RIS) with drainage water and wastewater (DWW) dilution with fresh water in the ratio of 1 : 1 showed that the net profit will amount to UAH 26,266.5 per 1 ha, while the dilution in the ratio of 1 : 2 – to UAH 26,161.5 per 1 ha. Complementary net profit will accordingly amount to UAH 1,337.8 and 1,231.5 per 1 ha. The most perspective technique to use DWW in rice irrigation systems is their reuse with dilution with fresh water at a ratio of 1 : 1 or 1 : 2. This ratio corresponds to most indicators for which was done an evaluation of water that is supplied for irrigation. Also this ratio does not lead to deterioration of soil salt regime.
Źródło:
Acta Scientiarum Polonorum. Architectura; 2020, 19, 1; 43-48
1644-0633
Pojawia się w:
Acta Scientiarum Polonorum. Architectura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Variable dynamics of sewage supply to wastewater treatment plant depending on the amount of precipitation water inflowing to sewerage network
Zmienność dynamiki dopływu ścieków do oczyszczalni w aspekcie przedostawania się wód opadowych do systemu kanalizacyjnego
Autorzy:
Bugajski, P. M.
Kaczor, G.
Chmielowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/292612.pdf
Data publikacji:
2017
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
precipitation
precipitation water
sewerage system
wastewater
opad atmosferyczny
system kanalizacyjny
ścieki
wody opadowe
Opis:
The paper analyzes the effect of precipitation water that inflowing to sanitary sewage system as accidental water on the changes in the total amount of treated sewage. The effects of accidental water supply on the total amount of sewage inflowing to treatment plant were analyzed based on mean daily amounts from the investigated periods and mean daily amounts from incidental supplies. The study was conducted in the years 2010–2015. Six characteristic research periods were identified (one per each calendar year), when the amount of sewage in the sanitary sewage system was greater than during dry weather. The analysis of changes in the amount of sewage supplied to the sewerage system in the six investigated periods revealed that the accidental water constituted from 26.8% to 48.4% of total sewage inflowing to the wastewater treatment plant (WWTP). In exceptional situations, during intense rains, the share of precipitation water in the sewerage system would increase up to 75%. Then, the rainwater inflowing the sewerage system caused hydraulic overloading of the WWTP by exceeding its maximum design supply.
W artykule przedstawiono analizę dotyczącą wpływu wielkości opadów atmosferycznych, które trafiają do kanalizacji sanitarnej jako wody przypadkowe, na zmienność ilości ścieków poddawanych procesom oczyszczania. Analizą dotyczącą wpływu wód przypadkowych na ilość ścieków dopływających do oczyszczalni objęto wartości średnie dobowe z badanych okresów oraz średnie dobowe dopływy ścieków z przypadków incydentalnych. Badania prowadzono w okresie od 2010 do 2015 roku, w którym wyróżniono 6 charakterystycznych okresów badawczych po jednym w każdym roku kalendarzowym, w których stwierdzono zwiększoną ilość ścieków w kanalizacji sanitarnej w porównaniu z ilością ścieków w kanalizacji w okresie pogody bezdeszczowej. W wyniku przeprowadzonej analizy dotyczącej zmienności ilości ścieków w kanalizacji w 6 okresach badawczych stwierdzono, że udział wód przypadkowych stanowił od 26,8 do 48,4% ogólnej ilości ścieków dopływających do oczyszczalni, natomiast w przypadkach incydentalnych w warunkach intensywnych opadów atmosferycznych udział wód opadowych w ogólnej ilości ścieków w systemie kanalizacyjnym wzrastał do 75%. W okresie badań w incydentalnych przypadkach wody opadowe przedostające się do kanalizacji powodowały przeciążenia hydrauliczne obiektu ponad dopływ maksymalny, na jaki została zaprojektowana oczyszczalnia.
Źródło:
Journal of Water and Land Development; 2017, 33; 57-63
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oczyszczalnie przydomowe a zagrożenie środowiska wodnego
Water environment pollution and building on-site waste-water treatment systems
Autorzy:
Eymontt, A.
Rogulski, B.
Powiązania:
https://bibliotekanauki.pl/articles/239330.pdf
Data publikacji:
2006
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
ścieki
oczyszczalnia przydomowa
złoże
rozsączanie
wastewater
on-site system
bed
drainage
Opis:
Oczyszczalnie przydomowe ścieków bytowych są od kilkunastu lat wprowadzane na tereny wiejskie jako rozwiązanie alternatywne w stosunku do zbiorczych systemów oczyszczania ścieków. W wielu gminach, korzystając z liberalnych przepisów dotyczących ich budowy i eksploatacji, zastosowano rozwiązania grupowe, po kilkaset oczyszczalni w jednej gminie lub wsi, co stwarza zagrożenie dla środowiska wodnego i glebowego przy niewielkiej, wymaganej przepisami redukcji zanieczyszczeń w odprowadzanych, oczyszczonych ściekach. Dotychczasowe wyniki badań jakości odprowadzanych ścieków wykazały, że równolegle należy badać jakość wód gruntowych i podziemnych wokół oczyszczalni przydomowych, a szczególnie grup oczyszczalni, co pozwoli na określenie zakresu ich zastosowania. Na terenach wiejskich znajduje się większość zasobów wodnych i należy przeciwdziałać ich zanieczyszczaniu. W ocenie badanych oczyszczalni mogą być szczególnie przydatne normy i projekty tematycznych norm europejskich.
On-site waste-water treatment systems have been implemented on rural areas for several years as alternative solution to the typical canalization. In many gminas, availing of the liberal building and exploitation regulations treated about the on-site systems have been implemented grouped such a systems with a few hundred in one gmina or village. It causes great pollution water and soil environment, when pollution reduction level in treated waste-water, according to the existing regulations is very low. Up till now, measurement results of the quality of outlet waste-water from on-site systems showed us, that parallel should be measured quality of the surface and underground waters from around on-site systems, particularly groups of the on-site systems, what allows for the evaluation of the future scope of these systems building. It must be underlined, that on the rural areas are the greatest part of the water magazines, and we must prevent water pollution. In evaluation of the on-site systems will be very helpful European Standards and Standards Projects from that area.
Źródło:
Problemy Inżynierii Rolniczej; 2006, R. 14, nr 2, 2; 107-116
1231-0093
Pojawia się w:
Problemy Inżynierii Rolniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of the Magnetic Water Treatment Mechanism
Autorzy:
Vaskina, Iryna
Roi, Ihor
Plyatsuk, Leonid
Vaskin, Roman
Yakhnenko, Olena
Powiązania:
https://bibliotekanauki.pl/articles/123611.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wastewater
aqueous solutions
water isomer
magnetic induction
non-equilibrium system
librational fluctuation
Opis:
The main problem of widespread introduction of magnetic water treatment (MWT) in the processes of water and wastewater treatment is the lack of modern research aimed at studying the mechanisms of MWT effects, in particular the influence on the physicochemical properties of aqueous solutions. This study explains the effect of MWT taking into account the physical and chemical properties of aqueous solutions due to the presence of the quantum differences in water molecules. All of the MWT effects are related to the change in the physicochemical properties of aqueous solutions. It is due to the presence of two types of water molecule isomers and their librational oscillations. The result of MWT is a violation of the synchronism of para-isomers vibrations, with the subsequent destruction of ice-like structures due to the receiving of energy from collisions with other water molecules (ortho-isomers). One of the most important MWT effects includes the change in the nature and speed of the physicochemical processes in aqueous solutions by increasing the number of more physically and chemically active ortho-isomers. The MWT parameters specified in the work allow explaining the nature of most MWT effects and require developing the scientific and methodological principles for the implementation of the MWT process and mathematical modeling of the MWT process in the water and wastewater treatment. It can be used in the design of the MWT devices taking into account the constructive and mode parameters of MWT devices.
Źródło:
Journal of Ecological Engineering; 2020, 21, 2; 251-260
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies