Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Vibroacoustic Method" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Evaluation of the Technical Condition of the Active Part of the High Power Transformer Based on Measurements and Analysis of Vibroacoustic Signals
Autorzy:
Borucki, S.
Cichoń, A.
Majchrzak, H.
Zmarzły, D.
Powiązania:
https://bibliotekanauki.pl/articles/176397.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
vibration
vibroacoustic method
core
power transformer
transformer diagnostics
Opis:
This article presents the results of research connected with the development and industrial use of vibroacoustic methods for the evaluation of the technical condition of the active part of transformers. The article presents the results of the analysis of vibrations generated by the high power transformer in which a defect was found on the basis of tests of oil carried out using the chromatography tests. In order to confirm the damage of the active part of this transformer, vibroacoustic measurements were performed in three states of its operation. The measurement using the classical vibroacoustic method included the registration of vibrations at the idle speed and during the load operation of the transformer. The original diagnostic method, so-called the modified vibroacoustic method, was also used during the measurement. The analysis of signals recorded using the classical vibroacoustic method was carried out in the frequency domain by indicating the amplitude of even harmonic vibrations. However, the analysis of signals measured during the commissioning of the transformer was conducted in the time-frequency domain using the short-time Fourier transform (STFT), continuous wavelet transform (CWT), and discrete wavelet transform (DWT). On the basis of the analysis of the results obtained it was stated that the increased level of vibrations of this transformer is a consequence of the loss of rigidity of the mechanical structure of its core.
Źródło:
Archives of Acoustics; 2017, 42, 2; 313-320
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania charakterystyki drgań zaworu homogenizującego
The research on vibration characteristics for homogenisation valve
Autorzy:
Komsta, H.
Łukasik, K.
Powiązania:
https://bibliotekanauki.pl/articles/287211.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
zawór homogenizujący
drgania
metoda wibroakustyczna
metoda fotooptyczna
homogenisation valve
vibration
vibroacoustic method
photo-optic method
Opis:
W pracy przedstawiono wyniki badań wibroakustycznych zaworu homogenizującego homogenizatora wysokociśnieniowego. Zarejestrowane drgania poddano analizie z wykorzystaniem szybkiej transformaty Fouriera oraz analizie JTFA. Badania miały na celu ocenę możliwości wykorzystania charakterystyk wibracyjnych zaworu homogenizującego do wnioskowania, o jakości pracy homogenizatora wysoko-ciśnieniowego metodami wibroakustycznymi. Ocenę tą odnoszono do bezpośrednich pomiarów drgań grzybka zaworu metodą fotooptyczną.
The paper presents the results of vibroacoustic tests carried out for homogenisation valve of a high-pressure homogeniser. Registered vibrations were put to analysis using fast Fourier transform and to the JTFA analysis. The purpose of the research was to assess the potential for using vibration characteristics of homogenisation valve to determine quality of high-pressure homogenizer work on the basis of vibroacoustic methods. The assessment was referred to direct measurements of valve head vibrations using the photo-optic method.
Źródło:
Inżynieria Rolnicza; 2008, R. 12, nr 9(107), 9(107); 143-150
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka transformatorów energetycznych z wykorzystaniem metody wibroakustycznej
Diagnostics of Power Transformers Using the Vibroacoustic Method
Autorzy:
Borucki, S.
Cichoń, A.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/155761.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformator energetyczny
drgania
rdzeń
metoda wibroakustyczna
diagnostyka
power transformer
vibration
core
vibroacoustic method
diagnostic
Opis:
Tematyka artykułu dotyczy diagnostyki rdzeni transformatorów elektro-energetycznych dużej mocy z wykorzystaniem pomiarów drgań wibroaku-stycznych. W artykule, na podstawie analizy drgań mechanicznych kadzi, dokonano oceny stanu technicznego czterech transformatorów blokowych typu TFBb 240000/400. Scharakteryzowano układ pomiarowy, który został wykorzystany podczas rejestracji sygnałów pochodzących od przenoszonych przez kadź drgań rdzenia poszczególnych jednostek. W oparciu o przyjęte w artykule wartości kryterialne podjęto próbę oceny stanu technicznego diagnozowanych urządzeń elektroenergetycznych.
During its operation a power transformer is subjected to the influence of numerous unfavourable factors which shorten its operation time and can cause unexpected disastrous failures. As far as the active part of a transformer is considered, magnetostrictic vibrations and cellulose depolymerization are the most harmful factors causing the loss of mechanical strength. Their influence results in the gradual loosening of the pressing and clamping of the core and transformer windings, which leads to the weakening of the active part mechanical construction (Fig. 1). In the electric power sector there are a few methods for detection of damages in power transformers. One of them is the vibroacoustic method which consists in measurement and analysis of vibrations of the object under study. Its application to high-power transformer diagnostics enables, first of all, assessing the technical condition of the core. Additionally, combining this method with other diagnostic methods can provide information not only on the core technical condition but also on the solid insulation properties of the device being tested [5 - 6]. In the paper the technical assessment of the condition of four unit transformers of type TFBb 240000/400 is performed basing on the analysis of mechanical vibrations of the tub. The basic technical parameters of the transformers are listed in Table 1. The measuring system used for recording the signals coming from the core vibrations of the particular units and transferred by the tub is described. Based on the criterion values [among others 6 - 8] an attempt to assess the technical condition of the electric power appliances diagnosed is made. The investigations and analyses carried out confirm that the measurement results of vibrations of the particular units have not revealed any damage to their cores or other defects of mechanical character.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 1, 1; 19-22
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka rdzenia transformatora elektroenergetycznego z wykorzystaniem zmodyfikowanej metody wibroakustycznej
Diagnosis of power transformer core using the modified vibroacoustic method
Autorzy:
Borucki, S.
Powiązania:
https://bibliotekanauki.pl/articles/153865.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformator elektroenergetyczny
rdzeń
diagnostyka
analiza czasowo-częstotliwościowa
drgania
metoda wibroakustyczna
power transformer
core
diagnosis
time and frequency domain analysis
vibration
vibroacoustic method
Opis:
Genezę podjętych w artykule prac stanowi problem skutecznej oceny stanu technicznego konstrukcji mechanicznej rdzeni transformatorów elektroenergetycznych. W publikacji zaprezentowano wyniki wskazujące na możliwość opracowania nowej i bezinwazyjnej metody diagnostycznej rdzeni z wykorzystaniem zaproponowanej przez autora tzw. zmodyfikowanej metody wibroakustycznej (MVM). Zamieszczone w artykule oryginalne rezultaty badań uzyskano podczas prób laboratoryjnych z wykorzystaniem transformatora olejowego o mocy 200 kVA.
The problem of effective assessment of the technical condition of power transformer core mechanical structure originated the research work discussed in this paper. The investigation results show the possibility of developing a new and non-invasive diagnostic method for the transformer magnetic circuit. The method developed is based on time-frequency analysis of measured mechanical vibrations of the device monitored. The recording of vibrations is performed during the monitored transformer no-load operation. The paper characterises the power object under study (Fig. 1), the measuring system applied and discusses the new methodology for assessing the core technical condition using the modified vibroacoustic method (MVM). The original measurement results presented in the paper were obtained during switching on a 200 kVA transformer under laboratory conditions. The analysis of the signals measured was carried out for three operating conditions of the transformer under study: with the core pressed by a manufacturer; with the core with loose screws fixing the upper yoke (Fig. 2a) and with the core with loose screws fixing the upper and lower yokes (Fig. 2b). The research results (Figs. 3-5) obtained from this experiment show a potential possibility of developing a non-destructive and effective method for assessing the technical condition of the core mechanical structure of transformer units operating in the electric power system, especially the ones of a strategic character.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 4, 4; 331-334
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies