Wyświetlanie 1-8 z 8
Tytuł:
An estimation of conditions inside construction works during a fire with the use of Computational Fluid Dynamics
Autorzy:
Sztarbała, G.
Powiązania:
https://bibliotekanauki.pl/articles/201986.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
computational fluid dynamics (CFD)
fire
buildings
ventilation systems
Opis:
The aim of this paper is to present the application of Computational Fluid Dynamics (CFD) to the assessment of conditions inside construction works during a fire. The CFD method is now commonly used to support the design process of fire safety in construction works. This method is very useful at the preliminary stage of design because it is possible to check the internal environment during a fire and evaluate whether requirements of fire safety are met.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 1; 155-160
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Threats occurring in the functioning of shelter ventilation installations
Autorzy:
Wasilczuk, Jarosław
Powiązania:
https://bibliotekanauki.pl/articles/132000.pdf
Data publikacji:
2019
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
energy-efficient buildings
climate
multi-family shelter
ventilation systems
Opis:
Ventilation of facilities such as shelters is a very complex issue. First of all, such an object should be extremely tight so that intentional air pollution outside does not pose a threat to people inside. Secondly, the system must be characterized by high reliability, because for airtight objects the failure of the air conditioning system is also a threat to people inside. Thirdly, the system must provide microlimatic vacancies inside acceptable by people passing through the shelter - it is mainly about temperature and humidity.
Źródło:
Modern Engineering; 2019, 2; 55-60
2450-5501
Pojawia się w:
Modern Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zagrożenia metanowego w ścianie G-6 w pokładzie 412łg+łd i 412 łg w KWK „A” – studium przypadku
The analysis of methane hazard in the G-6 longwall of coal seam 412 (top layer + lower layer) at the “A” Coal Mine – case study
Autorzy:
Badura, H.
Araszczuk, D.
Powiązania:
https://bibliotekanauki.pl/articles/164457.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Górnictwa
Tematy:
zagrożenie metanowe
metanowość
stężenie metanu
sposoby przewietrzania
methane hazard
methane content
methane concentration
ventilation systems
Opis:
Artykuł napisano na podstawie danych pomiarowych stężenia metanu na wylocie z rejonu ściany, strumienia objętości powietrza na wylocie z rejonu wentylacyjnego ściany, strumienia objętości metanu ujętego systemem odmetanowania oraz notowań przekroczeń dopuszczalnych stężeń metanu w rejonie ściany. Omówiono warunki naturalne panujące w rejonie ściany i stosowane sposoby przewietrzania. Obliczono metanowość całkowitą oraz wentylacyjną rejonu ściany i przeanalizowano ich zmiany. Przebadano zmiany strumienia objętości metanu ujętego systemem odmetanowania. Omówiono statystykę miejsc i częstości występowania przekroczeń dopuszczalnego stężenia metanu i porównano ryzyko wybuchu metanu dla zastosowanych sposobów przewietrzania na „Y” i „U”.
This paper was written on the basis of measurement data concerning methane concentration at the outlet of the longwall area, the air flow at the outlet of the longwall ventilation area, the flow rate of methane encompassed in methane drainage system, and permissible concentration of methane in the longwall area exceedance ratings. The paper discusses natural conditions in the longwall area and its ventilation systems. The total methane bearing capacity and methane content in the ventilation air were calculated and their changes analyzed. The changes in rate of methane flow through its drainage system were analyzed as well. Finally, the exceedances of methane concentration and the risk of methane explosion for “Y” and “U” ventilation systems were examined.
Źródło:
Przegląd Górniczy; 2017, 73, 4; 47-55
0033-216X
Pojawia się w:
Przegląd Górniczy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie technologii skaningu laserowego i termowizji do inwentaryzacji tunelu i znajdujących się w nim urządzeń przeciwpożarowych
The Use of Laser Scanning Technology and Infrared Thermography to Survey a Tunnel and its Fire Protection Devices
Autorzy:
Dronszczyk, P.
Strach, M.
Powiązania:
https://bibliotekanauki.pl/articles/373778.pdf
Data publikacji:
2016
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
systemy przeciwpożarowe
systemy wentylacyjne
tunel
skanowanie laserowe
termowizja
fire protection systems
ventilation systems
tunnel
laser scanning
infrared thermography
Opis:
Cel: Celem badań było przedstawienie wyników inwentaryzacji wybranych elementów wyposażenia przeciwpożarowego krakowskiego tunelu szybkiego tramwaju (KST). W pracach doświadczalnych zostały zastosowane nowoczesne techniki pomiarowe 3D ze szczególnym uwzględnieniem skanowania laserowego uzupełnionego o termowizję. W celu ułatwienia korzystania z opracowanych obiektów wszystkie dane zostały udostępnione zdalnie na portalu internetowym. Metody: Pomiary inwentaryzacyjne przeprowadzono z wykorzystaniem skanera laserowego 3D – Faro Focus X130. Skaner wykonuje jednocześnie pomiar kąta poziomego i pionowego oraz odległości do danego punku. Dodatkowo każdy punkt może posiadać atrybut koloru rzeczywistego w modelu przestrzeni barw RGB. Możliwe jest także wyświetlanie chmur punktów wraz z informacją o intensywności odbicia wiązki w skali szarości. Zbiory punktów zarejestrowanych na poszczególnych stanowiskach pomiarowych dają w rezultacie chmurę punktów reprezentującą geometrię obiektu. W ramach badań wykonano uzupełniające pomiary termowizyjne kamerą FLIR S60. W następnej kolejności skalibrowano ze sobą obrazy termowizyjne i połączono je z chmurą punktów uzyskaną ze skanowania laserowego. Wyniki: Otrzymane wyniki potwierdziły, że metoda skanowania laserowego, uzupełniona o obrazy termowizyjne, pozwala na uzyskanie bogatej informacji przestrzennej o mierzonym obiekcie. Wśród zinwentaryzowanych elementów wyposażenia obiektu można zidentyfikować: przewody prądowe, oświetlenie, rozdzielnie prądowe, przewody wentylacyjne czy też systemy przeciwpożarowe. Do tych ostatnich można zaliczyć: system przeciwdymowy wraz z systemem klap i kanałów. Wnioski: Wyniki przeprowadzonych badań inwentaryzacyjnych dowodzą, jak bardzo przydatne może być połączenie technologii skanowania laserowego i termowizji. Jest to szczególnie istotne w pomiarach obiektów ważnych z punktu widzenia bezpieczeństwa pożarowego. Przestrzenna wizualizacja ułatwia i usprawnia pozyskanie informacji oraz jej dalsze wykorzystanie. Zalety tych połączonych technik to przede wszystkim uzyskanie pełnej informacji o geometrii obiektu i urządzeniach towarzyszących. Cennym uzupełnieniem informacji o obiekcie jest wówczas termowizja, dzięki której można rozpoznać urządzenia czy elementy systemów o różniącej się temperaturze.
Aim: The main aim of the study was to present the results of a survey of a variety of fire-preventive equipment in the Kraków Fast Tram tunnel (KST). Experimental studies involved modern 3D surveying techniques, particularly 3D laser scanning and infrared thermography. In order to facilitate the use of the generated findings, all data have been made available remotely on a web portal. Methods: Survey measurements were taken using a Faro Focus X130 3D laser scanner. The scanner simultaneously performs vertical and horizontal angle measurements and calculates the distance to a given point. In addition, each point can have a real colour value in RGB space. It is also possible to present point clouds together with the intensity values in grayscale. The collections of points registered at individual vantage points result in a cloud of points representing the geometry of the object. Additional thermal measurements were carried out as part of the study, using a FLIR S60 camera. Finally, thermal images were calibrated and merged with the point cloud obtained from the laser scanning. Results: The results confirmed that laser scanning, together with thermal, images allows us to obtain detailed spatial information about the surveyed structure. Among the surveyed elements of the structure’s equipment the following can be identified: cable trays, lighting, switchboards, ventilation ducts, and fire-protection systems. The latter include a smoke protection system, together with valves and channels. Conclusions: The results demonstrate the usefulness of combining 3D laser scanning measurements and infrared thermography. This is especially important in the measurement of objects responsible for security and fire safety. Spatial visualisation facilitates and streamlines the acquisition of data and their further use. The primary advantage of combining these two techniques is the acquiring of complete geometrical information on the object and the corresponding devices. Another valuable addition is infrared thermography. It allows the identifying of devices or items in a single system with varying temperatures.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2016, 43, 3; 199-214
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exposure of ventilation system cleaning workers to harmful microbiological agents
Narażenie pracowników konserwujących instalacje wentylacyjne na szkodliwe czynniki mikrobiologiczne
Autorzy:
Gołofit-Szymczak, Małgorzata
Ławniczek-Wałczyk, Anna
Górny, Rafał L.
Powiązania:
https://bibliotekanauki.pl/articles/2166331.pdf
Data publikacji:
2014-11-05
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
bioaerozole
instalacje wentylacyjne
narażenie zawodowe
szkodliwe czynniki biologiczne
bioaerosols
ventilation systems
occupational exposure
harmful biological agents
Opis:
Background: Regular inspection of the cleanliness of the ventilation systems, as well as their periodic cleaning and disinfection, if necessary, are the main factors of the proper maintenance of each system. Performing maintenance operations on the ventilation system, workers are exposed to risk associated with the exposure to harmful biological agents. The aim of this study was to assess the employees' exposure to bioaerosols during maintenance work on ventilation systems. Material and Methods: Bioaerosol measurements were carried out using a button sampler. The microbial particles were collected on gelatin filters. Settled-dust samples from the inner surface of the air ducts and filter-mat samples were selected for the microbiological analysis. In the collected air, dust and filter samples the concentration of bacteria and fungi were determined. Results: Bacteria and fungi concentrations ranged between 3.6×10²-2.2×10⁴ CFU/m³ and 4.7×10²-4.5×10³ CFU/m³ at workplaces where the operations connected with mechanical ventilation cleaning were performed and 2.2×10⁴-1.2×10⁵ CFU/m³ and 9.8×10¹-2.5×10² CFU/m³ at workplaces where filter exchange was performed, respectively. The qualitative analysis of microorganisms isolated from the air in all studied workplaces revealed that the most prevalent bacteria belonged to Bacillus genus. The average concentrations of bacteria and fungi in filter-mat samples were 3.3×10³ CFU/cm² and 1.4×10⁴ CFU/cm², respectively. In settled-dust samples, average concentrations were 591 CFU/100 cm² and 52 CFU/100 cm², for bacteria and fungi respectively. Conclusions: Workers cleaning ventilation systems are exposed to harmful biological agents classified into risk groups, 1 and 2, according to their level of the risk of infection. The research conducted in the workplace can be the basis of risk assessment related to exposure to harmful biological agents during maintenance work in ventilation. Med Pr 2013;64(5):613–623
Wprowadzenie: Istotnym elementem właściwej eksploatacji instalacji wentylacyjnych jest regularna kontrola czystości wentylacji oraz jej okresowe czyszczenie i dezynfekcja. W ostatnich latach obserwuje się dynamiczny rozwój firm zajmujących się konserwacją instalacji wentylacyjnych. Pracownicy prowadzący prace konserwacyjne instalacji wentylacyjnej narażeni są na działanie szkodliwych czynników biologicznych. Celem niniejszej pracy było określenie narażenia na te czynniki podczas prac konserwacyjnych w instalacjach wentylacyjnych. Materiał i metody: Pobieranie próbek powietrza wykonano jako pomiar indywidualny za pomocą pobornika guzikowego. Powierzchnię wychwytu stanowiły sterylne filtry żelatynowe. Analizie poddano również próbki pyłu osiadłego z wewnętrznych powierzchni przewodów wentylacyjnych oraz próbki zużytych mat filtracyjnych. Zarówno w próbkach powietrza, pyłu osiadłego, jak i filtrach określano stężenie bakterii i grzybów, a następnie identyfikowano rodzaj lub gatunek wyizolowanych mikroorganizmów. Wyniki: Stężenia aerozolu bakteryjnego i grzybowego mieściły się w zakresie odpowiednio 3,6×10²-2,2×10⁴ jtk/m³ i 4,7×10²-4,5×10³ jtk/m³ na stanowiskach pracy, na których wykonywano czynności związane z mechanicznym czyszczeniem instalacji wentylacyjnych, oraz 2,2×10⁴-1,2×10⁵ jtk/m³ i 9,8×10¹-2,5×10² na stanowiskach pracy, na których wymieniano filtry. W powietrzu na wszystkich badanych stanowiskach pracy dominowały bakterie z rodzaju Bacillus. Średnie stężenie mikroorganizmów wyizolowanych z próbek mat filtracyjnych wynosiło dla bakterii: 3,3×10³ jtk/cm², a dla grzybów: 1,4×10⁴ jtk/cm², natomiast z próbek pyłu osiadłego - 591 jtk/100 cm² dla bakterii i 52 jtk/100 cm² dla grzybów. Wnioski: Pracownicy konserwujący instalacje wentylacyjne są narażeni na kontakt ze szkodliwymi czynnikami biologicznymi z 1. i 2. grupy zagrożenia. Badania przeprowadzone na stanowiskach pracy mogą być podstawą oceny ryzyka zawodowego związanego z narażeniem na szkodliwe czynniki biologiczne podczas prac konserwacyjnych w instalacjach wentylacyjnych. Med. Pr. 2013;64(5):613–623
Źródło:
Medycyna Pracy; 2013, 64, 5; 613-623
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Testing the Acoustic Silencers
Autorzy:
Pierchała, M.
Powiązania:
https://bibliotekanauki.pl/articles/176514.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
silencers
aerodynamic noise
noise reduction
ventilation systems
numerical tests
acoustic field
sound absorbing cassettes
dispersing component
Opis:
Problems associated with designing silencers are presented. Results of direct tests of silencers for cooperation with systems of axial fans, as well as results of numerical tests of a two stage acoustic silencer, are given. The numerical tests enabled determining the distribution of acoustic field inside the silencer and in the surrounding area. In those tests A sound insertion losses for different variants of installation inside the silencer, as well as for two different types of absorbing material used to fill the silencer walls, were determined. Impact of design features of silencers on effectiveness of noise reduction is described. Also, a technical sketch of a universal silencer with significant noise reduction (DipS = 39:1 dB) which can be successfully used in many ventilation systems is presented.
Źródło:
Archives of Acoustics; 2018, 43, 2; 313-321
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie poziomu stężenia bioaerozolu w centralnym systemie wentylacyjnym
Modeling of bioaerosol concentration in HAVC system
Autorzy:
Grzybowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/2071167.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
bioaerozol
filtracja powietrza
syndrom chorego budynku
systemy wentylacyjne
bioaerosol
air filtration
Sick House Syndrome
ventilation systems
Opis:
Zaprezentowano model opisujący dynamikę zanieczyszczania kanału wentylacyjnego i jego kolonizację mikroorganizmami. Model umożliwia przewidywanie zmian stężenia cząstek bioaerozolowych na wylocie z kanału wentylacyjnego. Przedstawiono także wyniki pomiarów bioaerozolowych wykonanych w rzeczywistym budynku w Warszawie sugerujące wtórne generowanie się cząstek bioaerozolowych w tamtejszym kanale wentylacyjnym.
A mathematical model describing the dynamics of ventilation duct contamination and its colonization with microorganisms is presented. The model enables the prediction of changes of bioaerosol particles concentration at the duct outlet. The results of bioaerosol measurements conducted in a real building in Warsaw are also presented. These results indicated a secondary generation of bioaerosol particles inside the duct.
Źródło:
Inżynieria i Aparatura Chemiczna; 2010, 4; 24-25
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie hybrydowych kolektorów fotowoltaicznych PVT w systemach przygotowania ciepłej wody użytkowej i centralnego ogrzewania w budynkach jednorodzinnych
Use of PVT hybrid solar collectors in hot water and central heating systems in single-family buildings
Autorzy:
Rozpondek, Maciej
Kapsrzyk, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/115398.pdf
Data publikacji:
2018
Wydawca:
Wyższa Szkoła Techniczna w Katowicach
Tematy:
hybrydowe kolektory fotowoltaiczne PVT
systemy grzewcze
systemy wentylacyjne
pompa ciepła
photovoltaic thermal hybrid solar collectors
heating systems
ventilation systems
heat pump
Opis:
Przeanalizowano sposoby zastosowania hybrydowych kolektorów fotowoltaicznych PVT do wytwarzania energii elektrycznej i ciepłej wody użytkowej. Zaprezentowano schematy procesowe instalacji ciepłowniczej dla domu jednorodzinnego wykorzystującej powietrzną pompę ciepła z wymiennikiem zasilanym z wodnych hybrydowych paneli fotowoltaicznych PVT. Opracowano schemat procesowy instalacji grzewczej z udziałem fotowoltaicznej I termicznej pompyciepła PVT-HP zwbudowanym parownikiem pompyciepła orazzespolonej z magazynem ciepła. Zaprezentowano uniwersalne rozwiązanie wykorzystujące możliwość kompleksowego wykorzystania dwuobiegowej fotowoltaicznej I termicznej pompy ciepła w układzie z gruntowym wymiennikiem ciepła w systemie wentylacyjnym.
Methods of using PVT hybrid solar collectors to generate electrical energy and hot tap water were analyzed. The process diagrams of heating installation for a single-family house using an air-to-water heat pump with an interchanger powered by water-based hybrid PVT solar panels were presented. A process diagram of heating installation with the use of a PVT-HP solar thermal / heat pump with a built-in heat pump evaporator, combined with heat storage was developed. A universal solution using the capability of a complex use of a two-speed photovoltaic / thermal heat pump in a system with a ground heat interchanger in a ventilation system was presented.
Źródło:
Zeszyty Naukowe Wyższej Szkoły Technicznej w Katowicach; 2018, 10; 91-104
2082-7016
2450-5552
Pojawia się w:
Zeszyty Naukowe Wyższej Szkoły Technicznej w Katowicach
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies