Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "turbina, J." wg kryterium: Wszystkie pola


Wyświetlanie 1-5 z 5
Tytuł:
Infrasound and low frequency noise of a wind turbine
Autorzy:
Wojsznis, M.
Szulczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/128032.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Instytut Mechaniki Stosowanej
Tematy:
low frequency noise
infrasound
wind turbine
hałas niskoczęstotliwościowy
infradźwięki
turbina wiatrowa
Opis:
The paper presents noise evaluation for a 2 MW wind turbine. The obtained results have been analyzed with regard to infrasound and low frequency noise generated during work of the wind turbine. The evaluation was based on standards and decrees binding in Poland. The paper presents also current literature data on the influence of the infrasound and low frequency noise on a human being. It has been concluded, that the permissible levels of infrasound for the investigated wind turbine were not exceeded.
Źródło:
Vibrations in Physical Systems; 2014, 26; 327-334
0860-6897
Pojawia się w:
Vibrations in Physical Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical modeling and preliminary validation of drag-based vertical axis wind turbine
Autorzy:
Krysiński, T.
Buliński, Z.
Nowak, A. J.
Powiązania:
https://bibliotekanauki.pl/articles/240209.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
numerical modeling
numerical axis wind turbine
computational fluid dynamics (CFD)
modelowanie numeryczne
turbina wiatrowa
komputerowa mechanika płynów
Opis:
The main purpose of this article is to verify and validate the mathematical description of the airflow around a wind turbine with vertical axis of rotation, which could be considered as representative for this type of devices. Mathematical modeling of the airflow around wind turbines in particular those with the vertical axis is a problematic matter due to the complex nature of this highly swirled flow. Moreover, it is turbulent flow accompanied by a rotation of the rotor and the dynamic boundary layer separation. In such conditions, the key aspects of the mathematical model are accurate turbulence description, definition of circular motion as well as accompanying effects like centrifugal force or the Coriolis force and parameters of spatial and temporal discretization. The paper presents the impact of the different simulation parameters on the obtained results of the wind turbine simulation. Analysed models have been validated against experimental data published in the literature.
Źródło:
Archives of Thermodynamics; 2015, 36, 1; 19-38
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ryzyko uszkodzeń instalacji i urządzeń turbin wiatrowych spowodowanych wyładowaniami atmosferycznymi
Risk of installations and wind turbines damage caused by lightning strike
Autorzy:
Głogowski, P.
Orymowska, J.
Pilip, K.
Powiązania:
https://bibliotekanauki.pl/articles/311243.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
turbina wiatrowa
ochrona odgromowa
wyładowania atmosferyczne
wind turbine
lightning protection
atmospheric discharges
Opis:
Wszystkie koncepcje ochrony odgromowej oparte są na teorii, że uszkodzenia popiorunowe będą najmniejsze wówczas, gdy impedancja elementów odprowadzających ładunek do podłoża będzie możliwie mała. Zastosowanie ścieżek małej impedancji powoduje, że prądy piorunowe zwykle nie docierają do elementów podatnych na uszkodzenia. Ochrona odgromowa łopat, łożysk, agregatu prądotwórczego i podzespołów elektronicznych wymaga, aby zapewnione było skuteczne uziemienie. W artykule przeanalizowano istniejące przepisy i regulacje definiujące co to oznacza oraz wskazano przykładowe sposoby jak je realizować w praktyce.
All lightning protection concepts are based on the theory that the lightning bolts will be the smallest when the impedance of the discharge elements to the ground will be as small as possible. Applying low impedance paths causes lightning currents to fail to reach the susceptible components. Lightning protection for blades, bearings, generator sets and electronic components requires effective grounding. The article discusses the existing rules and regulations defining what does it mean and shows examples how to implement it in practice.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 12; 880-884, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Three-dimensional representation of diagnostic features in application to wind turbines
Trójwymiarowa reprezentacja parametrów diagnostycznych w zastosowaniu do turbin wiatrowych
Autorzy:
Strączkiewicz, M.
Urbanek, J.
Barszcz, T.
Powiązania:
https://bibliotekanauki.pl/articles/329408.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
turbina wiatrowa
analiza drgań
zmienne warunki eksploatacyjne
wykrywanie uszkodzeń
wind turbine
vibration analysis
non-stationary operation
damage detection
Opis:
Wind turbine condition monitoring is essential task in the process of maintaining machine operation at the optimal level. It is related to ensuring the profitability of investment and the provision of security in the environment of the turbine. However, the working conditions of turbine associated with non-stationary nature of the stimulus which is wind, impede the correct diagnosis of the machine. In addition, a multitude of parameters adversely affects the clarity of predictions and setting alarm thresholds. In the article, the authors evaluate the impact of power generator and bearing rotational speed on the root-mean-square (RMS) value received on the generator bearing. The study was performed in various dynamic states of the bearing: the intact and after discovery of damage. It was possible due to long term monitoring of the system and further analysis of the RMS as a function of power and rotational speed. For this purpose the method that bases on calculation of arithmetic mean of the data in the segments corresponding to the chosen ranges of both rotational speed and generator output power. Results are presented in the form of three-dimensional charts, which allow assessing the impact of parameters on the estimator. As observed, a greater impact on the RMS has the power which reveals as more dynamic changes of RMS to the fluctuation of power. The variation of rotational speed does not affect RMS so rapidly. This was confirmed by an analysis of the slope the function obtained by linear regression. Therefore, it might lead to the conclusion that operational state of wind turbines should be assessed due to generated power level not in respect to rotational speed.
Monitorowanie stanu pracy turbiny wiatrowej jest niezbędnym zadaniem w procesie utrzymania pracy maszyny na optymalnym poziomie. Jest to związane zarówno z utrzymaniem rentowności inwestycji jak i zapewniania bezpieczeństwa w otoczeniu pracy turbiny. Jednakże warunki pracy turbiny związane z niestacjonarnym charakterem czynnika pobudzającego, jakim jest wiatr, utrudniają poprawną diagnozę stanu maszyny. Dodatkowo mnogość parametrów wpływa niekorzystnie na klarowność prognozy i ustawienie progów alarmowych. W artykule autorzy oceniają wpływ mocy generatora i prędkości obrotowej łożyska generatora na zmianę wartości skutecznej (RMS) wibracji otrzymanej na łożysku generatora. Obserwacja została poczyniona w dwóch stanach dynamicznych łożyska: w stanie nieuszkodzonym oraz po stwierdzeniu uszkodzenia. Umożliwiła to długoczasowa obserwacja turbiny pod kątem ww. parametrów, a następnie analiza zależności RMS w funkcji mocy i prędkości obrotowej. W tym celu zaproponowano metodę polegającą na obliczaniu średniej arytmetycznej wartości RMS w segmentach odpowiadającym wybranym zakresom prędkości obrotowej i mocy generatora. Wyniki przedstawiono w postaci trójwymiarowych wykresów, które pozwalają na ocenę wpływu parametrów na estymator. Jak zaobserwowano, większy wpływ na RMS ma parametr mocy generatora, co objawia się bardziej dynamiczną zmianą RMS w odniesieniu do zmiany mocy. Wahania prędkości obrotowej nie wpływają na estymator tak gwałtownie. Zostało to potwierdzone analizą współczynników kierunkowych funkcji otrzymanej przy pomocy regresji liniowej. Może to prowadzić do wniosku, że stan działania turbin wiatrowych powinien być oceniany ze względu na generowany poziom mocy a nie z powodu prędkości obrotowej.
Źródło:
Diagnostyka; 2012, 4(64); 9-16
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odnawialne źródła energii wizytówką innowacyjnego miasta - Worrstadt, Bydgoszcz, Częstochowa, Szczawnica
Autorzy:
Juchimiuk, J.
Powiązania:
https://bibliotekanauki.pl/articles/162873.pdf
Data publikacji:
2011
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
oszczędność energii
źródło energii odnawialne
efektywność energetyczna
energia słoneczna
farma fotowoltaiczna
turbina wiatrowa
przykład
Niemiecy
Polska
energy conservation
renewable energy source
energetic efficiency
solar energy
solar farm
wind turbine
example
Germany
Polska
Źródło:
Przegląd Budowlany; 2011, R. 82, nr 9, 9; 23-29
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies