Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "turbine" wg kryterium: Temat


Tytuł:
Review of design of high-pressure turbine
Autorzy:
Bugała, P.
Powiązania:
https://bibliotekanauki.pl/articles/246988.pdf
Data publikacji:
2017
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
preliminary design
turbomachinery
gas turbine
high-pressure turbine
HPT
projekt wstępny
turbo mechanizm
turbina gazowa
turbina wysokociśnieniowa
Opis:
The engine manufacturers adopt new measures in order to further improve the characteristics of a turbine engine. They pose new challenges to reduce a fuel consumption and an emission of pollution to the environment (including noise), but also keeping the highest level of reliability. Based on those considerations, current research in propulsion is conducted. Modern turbines are characterised by high inlet temperature. This has implications for engine efficiency, which is expressed with a change of mass, cross-section and fuel consumption. In this article, main trends in the development of turbine engines are presented. This analysis was carried out on the basis of Rolls-Royce engine data. The article presents literature review concerning the analytical methods of high-pressure turbines preliminary design. The aerodynamic design process is highly iterative, multidisciplinary and complex. Due to this, modern gas turbines need sophisticated tools in terms of aerodynamics, mechanical properties and materials. The article depicts simplified model of real turbine engine. As showed in the article, this model gives only a 10% error level in engine thrust value. The calculations may be used for preliminary engine analyses.
Źródło:
Journal of KONES; 2017, 24, 1; 67-76
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermo-economic comparative analysis of gas turbine GT10 integrated with air and steam bottoming cycle
Autorzy:
Czaja, D.
Chmielnak, T.
Lepszy, S.
Powiązania:
https://bibliotekanauki.pl/articles/240831.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
gas turbine air bottoming cycle
air bottoming cycle
gas turbine
GT10
układ gazowo-powietrzny
turbina gazowa
Opis:
A thermodynamic and economic analysis of a GT10 gas turbine integrated with the air bottoming cycle is presented. The results are compared to commercially available combined cycle power plants based on the same gas turbine. The systems under analysis have a better chance of competing with steam bottoming cycle configurations in a small range of the power output capacity. The aim of the calculations is to determine the final cost of electricity generated by the gas turbine air bottoming cycle based on a 25 MW GT10 gas turbine with the exhaust gas mass flow rate of about 80 kg/s. The article shows the results of thermodynamic optimization of the selection of the technological structure of gas turbine air bottoming cycle and of a comparative economic analysis. Quantities are determined that have a decisive impact on the considered units profitability and competitiveness compared to the popular technology based on the steam bottoming cycle. The ultimate quantity that can be compared in the calculations is the cost of 1 MWh of electricity. It should be noted that the systems analyzed herein are power plants where electricity is the only generated product. The performed calculations do not take account of any other (potential) revenues from the sale of energy origin certificates.
Źródło:
Archives of Thermodynamics; 2014, 35, 4; 83-95
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Marine gas turbine performance diagnostics: a case study
Autorzy:
Yfantis, E. A.
Kapasakis, P.
Powiązania:
https://bibliotekanauki.pl/articles/329290.pdf
Data publikacji:
2008
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
diagnostyka
turbina gazowa
wydajność
gas turbine
performance
diagnostics
Opis:
The paper discusses how performance models can be used for marine gas turbines. A particular performance model, built for on board training purposes is employed to demonstrate the different aspects of this process. The model allows the presentation of basic rules of gas turbine engine behavior and helps understanding different aspects of its operation. A smart designed graphics user interface is used to present engine operation in different ways: operating line, operating points of the components, interrelation between performance variables and parameters etc. The perception of fault signatures on monitoring parameters is clearly demonstrated. Diagnostics capabilities of the existing performance model installed at the Hellenic Naval Academy Gas Turbines Virtual Lab are examined and tested using the measurement data from real marine gas turbines. A case study is discussed in this paper where the model results and the real engine conditions are compared for diagnostic purposes.
Źródło:
Diagnostyka; 2008, 3(47); 61-64
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selection of the air heat exchanger operating in a gas turbine air bottoming cycle
Autorzy:
Chmielniak, T.
Czaja, D.
Lepszy, S.
Powiązania:
https://bibliotekanauki.pl/articles/240817.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
air heat exchanger
air bottoming cycle
gas turbine air bottoming cycle
gas turbine
powietrzny wywietrznik ciepła
obieg powietrza
turbina gazowa
Opis:
A gas turbine air bottoming cycle consists of a gas turbine unit and the air turbine part. The air part includes a compressor, air expander and air heat exchanger. The air heat exchanger couples the gas turbine to the air cycle. Due to the low specific heat of air and of the gas turbine exhaust gases, the air heat exchanger features a considerable size. The bigger the air heat exchanger, the higher its effectiveness, which results in the improvement of the efficiency of the gas turbine air bottoming cycle. On the other hand, a device with large dimensions weighs more, which may limit its use in specific locations, such as oil platforms. The thermodynamic calculations of the air heat exchanger and a preliminary selection of the device are presented. The installation used in the calculation process is a plate heat exchanger, which is characterized by a smaller size and lower values of the pressure drop compared to the shell and tube heat exchanger. Structurally, this type of the heat exchanger is quite similar to the gas turbine regenerator. The method on which the calculation procedure may be based for real installations is also presented, which have to satisfy the economic criteria of financial profitability and cost-effectiveness apart from the thermodynamic criteria.
Źródło:
Archives of Thermodynamics; 2013, 34, 4; 93-106
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energetic efficiency of the combined ORC and gas turbine installation powered by the anaerobic sewage sludge stabilization system
Autorzy:
Matysko, R.
Powiązania:
https://bibliotekanauki.pl/articles/240869.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ORC
sludge
biogas
gas turbine
ścieki
biogaz
turbina gazowa
Opis:
The present paper describes a cycle, which may be applied in sewage treatment plants as a system to convert biological waste into process heat and electricity. In sludge stabilization processes anaerobic fermentation acts as the source of methane, which can be used then to generate heat and electric current in gas turbines. Products of high-temperature oxidation can be utilized in organic Rankine cycles to generate electric power. Waste heat is used for heating the fermenting biomass. Energy balance equations mentioned in the thesis: organic Rankine cycle, regenerative gas turbine engine, anaerobic sludge stabilization system.
Źródło:
Archives of Thermodynamics; 2018, 39, 4; 71--83
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie emisji związków toksycznych w spalinach turbiny gazowej do zastosowań morskich w oparciu o charakterystyki emisji turbinowego silnika lotniczego
Determination of toxic exhaust emissions of a gas turbine for seagoing vessels based on a jet engine emission characteristic
Autorzy:
Pawlak, M.
Kuźniar, M.
Powiązania:
https://bibliotekanauki.pl/articles/316453.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
turbina gazowa
silniki okrętowe
turbinowe silniki lotnicze
współczynnik emisji
porównanie silników
gas turbine
marine engines
turbine aircraft engine
emission factor
engine comparison
Opis:
W artykule opisano metodykę wyznaczenia emisji wybranych szkodliwych związków do atmosfery przez turbinę gazową napędzającą morską jednostkę pływającą. Opisano konstrukcję takiego silnika, porównano go do spokrewnionego z nim silnika odrzutowego. Powiązano parametry obiegu silników używając do tego formuł gazodynamicznych, a na tej podstawie dobrano współczynniki emisji NOx, CO, HC. Wyniki zebrano w tabelach i przedstawiono na wykresach. Rezultaty analizy zostały omówione i są podstawą do dalszych, bardziej szczegółowych symulacji i analiz.
The paper describes the methodology for determining the emission into the atmosphere of selected harmful compounds generated by a gas turbine that drives a seagoing vessel. The design of such an engine was described and compared to its related jet engine. The engine parameters were adjusted using gasodynamic formulas and the NOx, CO, HC emission coefficients were adjusted accordingly. The results are summarized in tables and graphed. The results of the analysis are discussed and are the basis for further, more detailed simulations and analyzes.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 12; 345-350, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Gas turbine fault diagnostic system based on fuzzy logic
System diagnostyki awarii turbiny gazowej oparty na logice rozmytej
Autorzy:
Shuvatov, T.
Suleimenov, B.
Komada, P.
Powiązania:
https://bibliotekanauki.pl/articles/407986.pdf
Data publikacji:
2012
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
turbina gazowa
logika rozmyta
diagnostyka
gas turbine
fuzzy logic
diagnostic
Opis:
In the article a method of parametric diagnostics of a gas turbine, based on fuzzy logic is proposed. The diagnostic map of interconnection between some parts of turbine and changes of corresponding parameters has been developed. Also we have created model to define the efficiency of the compressor using fuzzy logic algorithms.
W artykule zaproponowano metodę parametrycznej diagnostyki turbiny gazowej w oparciu o logikę rozmytą. Opracowana została diagnostyczna mapa połączeń między niektórymi zespołami turbiny gazowej oraz zmianami odpowiednich parametrów. Ponadto udało nam się stworzyć model do określania wydajności sprężarki przy użyciu algorytmów logiki rozmytej.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2012, 3; 40-42
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Increased temperature impact on durability of gas turbine blades
Wpływ podwyższonej temperatury na trwałość łopatek turbiny gazowej
Autorzy:
Błachnio, J.
Bogdan, M.
Zasada, D.
Powiązania:
https://bibliotekanauki.pl/articles/1365612.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
gas turbine
blade
microstructure
durability
turbina gazowa
łopatka
mikrostruktura
trwałość
Opis:
The paper presents the research results of a microstructure of the turbine rotor blades made of nickel-based super alloys. The purpose of the research was to determine the high temperature impact on the microstructure stability of the material of the blades. The degree of advancement of the super alloy microstructure changes after the exposure to high temperature was compared to the mictrostructure condition of new blades. The research material includes blades made of EI 867 and ŻS 32 types of alloys. The microstructure research of blades subject to the high temperature impact, and the blades after operation showed the occurrence of adverse changes in relation to the microstructure of new blades. It was found that the cause of adverse changes in the microstructure was the super alloy overheating. The blade in such a condition has low heat and creep resistance. The element, in which the overheating will occur, is exposed to damage, which usually entails faulty turbine operation. This type of damage is removed during the engine major repair, which is associated with huge costs.
W artykule przedstawiono wyniki badań mikrostruktury łopatek wirnika turbiny wykonanych z nadstopów na bazie niklu. Celem badań było określenie skutków oddziaływania wysokiej temperatury na stabilność mikrostruktury materiału łopatek. Stopień zaawansowania zmian mikrostruktury nadstopu po oddziaływaniu wysokiej temperatury porównywano ze stanem mikrostruktury łopatek nowych. Materiałem do badań były łopatki ze stopów typu EI 867 oraz ŻS 32. Badania mikrostruktury łopatek poddawanych oddziaływaniu wysokiej temperatury oraz łopatek po eksploatacji wykazały występowanie niekorzystnych zmian w stosunku do mikrostruktury łopatek nowych. Stwierdzono, że przyczyną niekorzystnych zmian w mikrostrukturze było przegrzanie nadstopu. Łopatka w takim stanie wykazuje niską żaroodporność oraz żarowytrzymałość. Element, w którym wystąpi przegrzanie jest narażony na uszkodzenie, co przeważnie pociąga za sobą wadliwą pracę turbiny. Tego typu uszkodzenia usuwa się w trakcie naprawy głównej silnika co wiąże się z ogromnymi kosztami.
Źródło:
Eksploatacja i Niezawodność; 2017, 19, 1; 48-53
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of vapor superheating on the level of heat regeneration in a subcritical ORC coupled with gas power plant
Autorzy:
Wiśniewski, S.
Borsukiewicz-Gozdur, A.
Powiązania:
https://bibliotekanauki.pl/articles/240231.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ORG
regeneracja ciepła
turbina gazowa
gas turbine
heat regeneration
ORC
Opis:
The authors presented problems related to utilization of exhaust gases of the gas turbine unit for production of electricity in an Organic Rankine Cycle (ORC) power plant. The study shows that the thermal coupling of ORC cycle with a gas turbine unit improves the efficiency of the system. The undertaken analysis concerned four the so called "dry" organic fluids: benzene, cyclohexane, decane and toluene. The paper also presents the way how to improve thermal efficiency of Clausius-Rankine cycle in ORC power plant. This method depends on applying heat regeneration in ORC cycle, which involves pre-heating the organic fluid via vapour leaving the ORC turbine. As calculations showed this solution allows to considerably raise the thermal efficiency of Clausius-Rankine cycle.
Źródło:
Archives of Thermodynamics; 2010, 31, 3; 185-199
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of pressure drop in combustion chamber on gas turbine performance
Wpływ spadku ciśnienia w komorze spalania na osiągi turbiny gazowej
Autorzy:
Herdzik, Jerzy
Powiązania:
https://bibliotekanauki.pl/articles/1818415.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Technologiczno-Humanistyczny im. Kazimierza Pułaskiego w Radomiu
Tematy:
gas turbine
gas turbine performance
impact on performance
pressure drop measurement
turbina gazowa
osiągi turbiny gazowej
wpływ na osiągi
pomiar spadku ciśnienia
komora spalania
Opis:
Paper discusses the problem of pressure drop in the process of working medium flow through combustion chamber of gas turbine. The pressure loss is an internal disadvantage of combustion chamber depends on many parameters, especially the chamber design and working gas flowrate. There is a problem to calculate the parameters of working medium in characteristic points of gas turbine thermodynamic cycle because the total pressure before and after combustion chamber is not known. There is a lack of information from manufacturer about it and in publications as well (mainly no experimental data, only theoretical considerations). It will be important information because the pressure drop has an meaningful influence on gas turbine performance. The paper presents an estimation of decreasing the performance of gas turbine from discussed reason. Author of that manuscript recognized the necessity of showing the importance of that parameter and turning the attention to not fully recognized problem.
W artykule omówiono problem spadku ciśnienia w procesie przepływu czynnika roboczego przez komorę spalania w turbinie gazowej. Spadek ciśnienia jest wewnętrzną wadą turbiny zależną od wielu parametrów, głównie od projektu komory i natężenia przepływu gazu przez nią. Problemem jest wyznaczenie parametrów cyklu termodynamicznego turbiny w charakterystycznych punktach, ponieważ nie jest znane całkowite ciśnienie przed i za komorami spalania. Występuje brak tej informacji ze strony producenta urządzenia, jak i również w publikacjach naukowych (brak danych eksperymentalnych, tylko rozważania i modelowania teoretyczne). Jest to ważna informacja, ponieważ spadek ciśnienia w komorze spalania ma istotny wpływ na osiągi turbiny gazowej. W artykule przedstawiono oszacowanie obniżenia osiągów turbiny z omawianego powodu. Autor artykułu uznał potrzebę zwrócenia uwagi na ten parametr i nie do końca rozeznany problem.
Źródło:
Journal of Civil Engineering and Transport; 2020, 2, 3; 131-138
2658-1698
2658-2120
Pojawia się w:
Journal of Civil Engineering and Transport
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The problem of thermal unit elasticity under the conditions of dynamic RES development
Problem elastyczności bloków cieplnych w warunkach dynamicznego rozwoju OZE
Autorzy:
Kowalczyk, T.
Badur, J.
Ziółkowski, P.
Kornet, S.
Banaś, K.
Ziółkowski, P. J.
Stajnke, M.
Bryk, M.
Powiązania:
https://bibliotekanauki.pl/articles/397195.pdf
Data publikacji:
2017
Wydawca:
ENERGA
Tematy:
energy storage
operational flexibility
steam turbine
gas turbine
SOEC
hydrogen technologies
machine monitoring
magazyn energii
elastyczność pracy
turbina parowa
turbina gazowa
technologie wodorowe
monitoring maszyn
Opis:
The paper is an overview of selected ways of increasing the operational flexibility of steam units, which are predominant in the Polish power system. These studies were prompted by the dynamic changes in the structures of installed capacity and generation output in the National Power System due to a rapid increase in the number of wind turbines in the country. The methods of thermal unit operational flexibility improvement are divided into two groups. The first group comprises solutions with heat and mass storage as well as chemical energy storage. These are solutions to manage the auxiliary load of units regardless of system load. The second group consists of methods for an off-design increase in the safe level of thermal energy machine design stress. The development of numerical tools using complex methods of thermal stress determination, such as Burzyński-Pęcherski’s theory, combined with advanced on-line machine diagnostics, allows for an extension in the operational range of a machine, beyond the original safe operation limit without risk of damage or loss of service life, in other words.
W pracy przedstawiono przegląd wybranych sposobów zwiększania elastyczności pracy bloków parowych, które stanowią największą siłę wytwórczą w polskim systemie elektroenergetycznym. Motywacją do podjęcia prac w tym kierunku są dynamiczne zmiany w strukturze mocy zainstalowanej i energii wytwarzanej w Krajowym Systemie Elektroenergetycznym związane z szybkim wzrostem liczby siłowni wiatrowych na terenie kraju. Metody poprawy elastyczności pracy bloków cieplnych podzielono na dwie grupy. Pierwszą grupę stanowią rozwiązania wykorzystujące magazyny ciepła i masy oraz magazyny energii chemicznej. Są to rozwiązania pozwalające kształtować obciążenie potrzeb własnych bloku niezależnie od obciążenia systemu. Drugą grupę stanowią metody pozwalające na pozaprojektowe wytężanie konstrukcji maszyn cieplnych. Rozwój narzędzi numerycznych wykorzystujących złożone metody wyznaczania naprężeń cieplnych, takie jak np. teoria Burzyńskiego–Pęcherskiego, w połączeniu z zaawansowanymi systemami diagnostyki maszyn online, umożliwiają wychodzenie z pracą maszyn poza granice tzw. bezpiecznej pracy bez ryzyka uszkodzeń lub utraty żywotności.
Źródło:
Acta Energetica; 2017, 2; 116-121
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Image of the surface of gas turbine blade as a diagnostic signal
Autorzy:
Błachnio, J.
Zabrocka, I.
Powiązania:
https://bibliotekanauki.pl/articles/386743.pdf
Data publikacji:
2013
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
turbina gazowa
łopata
wspomaganie komputerowe
gas turbine
blade
discoloration
computer assistance
Opis:
This paper outlines a non-destructive method that is suitable for evaluation of condition demonstrated by gas turbine blades and is based on digital processing of images acquired from the blade surface in visible light. To enable high clearness of these images the particular attention is paid to the problem of how to provide optimum conditions for investigations and mitigate geometrical distortions of images acquired from maintenance operations. The paper demonstrates that there are relationships between operation lifetime of blades and discoloration of their surfaces due to overheating of the blade material. These relationships are revealed by digital analysis of images acquired for the blade surfaces and expressed as statistical parameter of the first and second order. To improve unambiguity of the analysis results a low-pass filter was applied. It was demonstrated that these relationships are suitable for evaluation how much the status of the blade material microstructure is altered.
Źródło:
Acta Mechanica et Automatica; 2013, 7, 4; 209-214
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energetic and exergetic analysis of a triple-pressure reheat combined cycle power using different primary movers
Autorzy:
Almutairi, Abdulrahman
Alhajeri, Hamad
Alenezi, Abdulrahman
Powiązania:
https://bibliotekanauki.pl/articles/240192.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
exergy
aeroderivative
gas turbine
reheat and waste exergy
egzergia
turbina gazowa
Opis:
In this work, actual operating data for Sabiya combined cycle power plant located in Kuwait were used to conduct the performance evaluation based on the energetic and exergetic analysis. The proposed system consist of an advanced gas turbine engines, with two triple pressure reheat heat recovery steam generator, and one steam turbine. Three types of primary movers were selected carefully, in order to cover different types, sizes and technologies. The movers are gas turbine engine frame 9FA, LM6000 and GT26. The proposed models have been developed using specialised software and validated with the manufacturer’s data featuring a high level of compatibility. The performance of a combined cycle power plant was investigated for different operating conditions. The result shows that the highest exergy destruction takes place in 9FA engine due to high irreversibility in combustion chamber because of low-pressure ratio, which causes low inlet temperature of compressed air to the combustion chamber. The 9FA engine also has the highest exergy loss due to high exhaust gases temperature, which is caused high useful work from a steam turbine. The GT26-reheat gas turbine engine constitute the best choose as primary mover due to low waste exergy, which is equal to 43.93% whereas 9FA and LM6000 equal to 47.27% and 45.17%, respectively. LM6000 aeroderivative gas turbine is considered the second best choice but the combined cycle power plant will consist of a large number of engines compared to other industrial gas turbine engine, and that may increase the number of auxiliary equipment, capital and maintenance cost.
Źródło:
Archives of Thermodynamics; 2019, 40, 2; 87-105
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of technical condition assessment of gas turbine blades with non-destructive methods
Autorzy:
Błachnio, J.
Powiązania:
https://bibliotekanauki.pl/articles/387534.pdf
Data publikacji:
2013
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
turbina gazowa
łopata
diagnozowanie
warunki techniczne
gas turbine
blade
diagnosing
technical condition
Opis:
Structural components of gas turbines, particularly the blades, sustain a variety of damages during the operation process. The most frequent cause of these damages are the overheating and thermal fatigue of the material. A primary technique to assess condition of the blades is the metallographic examination. In spite of the fact that metallographic analysis delivers much more information on the structure of examined blade material, it is a type of destructive test resulting in the destruction of the blade which makes further utilization of the item impossible. The paper has been intended to discuss non-destructive testing methods and to present capabilities of applying them to diagnose objectively changes in the microstructure of a turbine blade with computer software engaged to assist with the analyses. The following techniques are discussed: a visual method, based on the processing of images of the material surface in visible light, active thermography, based on the detection of infrared radiation, and the X-ray computed tomography. All these are new non-destructive methods of assessing technical condition of structural components of machines. They have been intensively developed at research centers worldwide, and in Poland. The computer-aided visual method of analyzing images enables diagnosis of the condition of turbine blades, without the necessity of dismantling of the turbine. On the other hand, the active thermography and the X-ray computed tomography, although more sensitive and more reliable, can both be used with the blades dismounted from the turbine. If applied in a complex way, the non-destructive methods presented in this paper, are expected to increase significantly probability of detecting changes in the blade’s condition, which in turn would be advantageous to reliability and safety of gas turbine service.
Źródło:
Acta Mechanica et Automatica; 2013, 7, 4; 203-208
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The methodology of the gas turbine efficiency calculation
Autorzy:
Kotowicz, J.
Job, M.
Brzęczek, M.
Nawrat, K.
Mędrych, J.
Powiązania:
https://bibliotekanauki.pl/articles/240275.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
gas turbine
polytropic efficiency
isentropic efficiency
turbina gazowa
efektywność politropowa
obiekt chłodniczy
Opis:
In the paper a calculation methodology of isentropic efficiency of a compressor and turbine in a gas turbine installation on the basis of polytropic efficiency characteristics is presented. A gas turbine model is developed into software for power plant simulation. There are shown the calculation algorithms based on iterative model for isentropic efficiency of the compressor and for isentropic efficiency of the turbine based on the turbine inlet temperature. The isentropic efficiency characteristics of the compressor and the turbine are developed by means of the above mentioned algorithms. The gas turbine development for the high compressor ratios was the main driving force for this analysis. The obtained gas turbine electric efficiency characteristics show that an increase of pressure ratio above 50 is not justified due to the slight increase in the efficiency with a significant increase of turbine inlet combustor outlet and temperature.
Źródło:
Archives of Thermodynamics; 2016, 37, 4; 19-35
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies