Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "przejściowe" wg kryterium: Temat


Wyświetlanie 1-7 z 7
Tytuł:
Comparison of transient states in step-down power converter (BUCK) in continuous and discontinuous conduction mode
Autorzy:
Janke, W.
Walczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/200450.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
step-down converter
BUCK
transient states
CCM
DCM
step-down konwerter
stany przejściowe
Opis:
The object of this paper is a step-down (BUCK) power converter working in the continuous conduction mode (CCM) or discontinuous conduction mode (DCM). Two types of transient states in a converter have been analyzed and observed experimentally: slow transients, described by averaged models of a converter and fast transients, in the course of a single switching period. The averaged models of converter working in CCM, presented in various sources are similar, with some differences concerning only the description of parasitic effects. The averaged models for DCM depend on the adopted modeling method. Models obtained by the switch averaging approach are second-order models (containing two reactive elements in equivalent circuit representation). Models obtained by the separation of variables approach are first-order models. The experimental results given in this paper show the first-order type of transients. Another group of experiments concern fast transients in the course of a single switching period. The oscillations of inductor voltage in the part of a switching period are observed for DCM.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2014, 62, 4; 773-778
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przepięcia występujące w stanach łączeniowych dla linii przesyłowej współpracującej z podsystemem lokalnym
Overvoltages occurring in switching states in transmission line cooperating with a local subsystem
Autorzy:
Macha, Daria
Sowa, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/269088.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przepięcia
stany łączeniowe
stany przejściowe
lokalne podsystemy
overvoltages
switching states
transient states
local subsystems
Opis:
W artykule przeprowadzono badania dotyczące przepięć występujących podczas stanów łączeniowych dla linii współpracującej z podsystemem lokalnym. Przeanalizowano przepięcia pojawiające się w linii połączonej z podsystemem lokalnym podczas operacji łączeniowych, wymuszanych przez zmianę warunków pracy sieci. Badane były elektromagnetyczne przebiegi przejściowe w nieobciążonej linii po jej nagłym odłączeniu od zasilania. W badaniach szczególną uwagę zwrócono na warunki wyłączania linii (moment oraz niejednoczesność odłączania), wpływ urządzeń przeciwprzepięciowych, rodzaj przekładnika oraz moc zwarciową podsystemów zasilających.
In the paper the overvoltages occurring during switching states in the line cooperating with a local subsystem were investigated. Overvoltages appearing in the line connected to the local subsystem during switching operations, were analyzed, forced by the change of network operation conditions. Electromagnetic transients in the unloaded line were tested after its sudden disconnection from the power supply. In the research, particular attention was paid to the conditions of switching off the line (moment and non-simultaneous disconnection), the influence of surge protection devices, the type of voltage transformer and the short-circuit power of the power subsystems.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 63; 43-46
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mathematical model of a general motion of vibratory machines driven by motors of a limited power
Model matematyczny ruchu ogólnego maszyn wibracyjnych napędzanych silnikami ograniczonej mocy
Autorzy:
Michalczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/219070.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
maszyny wibracyjne ograniczonej mocy
samosynchronizacja
stany przejściowe
vibratory machines of a limited power
self-synchronisation
transient states
Opis:
The method of creating the mathematical model of over-resonant vibratory machines driven in a general motion by the inertial vibrator of a limited power is presented in the paper. This model can constitute the basis for digital simulation of single- or multi-drive vibratory machines used in industry. It allows to investigate the steady and transient states of these machines as well as to investigate the advanced problems of the free synchronisation of drives.
W pracy przedstawiono sposób budowy modelu matematycznego nadrezonansowej maszyny wibracyjnej w ruchu ogólnym, napędzanej wibratorem inercyjnym ograniczonej mocy. Model ten może stanowić podstawę dla symulacji cyfrowej jedno-, lub wielonapędowych maszyn wibracyjnych używanych w przemyśle. Pozwala on na badanie zarówno pracy ustalonej tych maszyn jak i ich stanów przejściowych oraz na badanie zaawansowanych problemów synchronizacji swobodnej napędów.
Źródło:
Archives of Mining Sciences; 2013, 58, 2; 591-600
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie analizy statystycznej w badaniach pracy sieci elektroenergetycznej w stanach przejściowych z uwzględnieniem niepewności parametrów
The use of statistical analysis for the simulation investigation of power system dynamics including uncertainties of power system parameters
Autorzy:
Nocoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/267713.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
power system
transient states
uncertainty of the mathematical model parameters
system elektroenergetyczny
stany przejściowe
niepewność parametrów modelu matematycznego
Opis:
Obecnie w analizach pracy systemu elektroenergetycznego (SEE), coraz częściej wymagana jest ocena możliwości współpracy istniejących źródeł energii elektrycznej z nowoprojektowanymi źródłami. Podczas takich analiz często pojawia się problem braku wiarygodnych parametrów modeli matematycznych nowoprojektowanych i już działających źródeł w SEE. Problem ten można rozwiązać w różny sposób, między innymi poprzez przeprowadzenie obliczeń wielokrotnych (wariantowych). W artykule zaproponowano sposób ograniczenia niezbędnej liczby symulacji poprzez śledzenie współczynników statystycznych opisujących zbiór uzyskanych rozwiązań. W ramach badań przeprowadzono analizę różnych elektromechanicznych stanów przejściowych występujących w sieci średniego napięcia pracującej autonomicznie.
Nowadays, when analyzing the power system (PS) operation, the assessment of the possibility of cooperation of existing power sources with newly planned ones is required more and more often. During the PS analysis, there often appears a problem of the lack of reliable parameters of the mathematical models of newly designed and already operating in PS devices. This problem can be solved in many ways, i.a. by carrying out repeated calculations for the values of unknown parameters being changed in a given search interval. In the paper, there is presented a method for estimating the reliability of the obtained results based on monitoring the statistic factors describing the set of solutions obtained. The analysis of different statistic factors was performed within the framework of the research. The analysis was made for a factory medium voltage (15 kV) power network. The investigated network included the already installed asynchronous generator of 1.9 MW rated power and a newly designed synchronous generator of 4.56 MW rated power. Low voltage induction motors were connected to the network. There were investigated the transient states associated with a transient short-circuit in a line connecting the network of the factory with a high voltage network. The uncertainty of the mathematical model parameters of the generating units and the uncertainty of the PS load state were taken into account based on the measured and recorded average values of the active power taken from the PS.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 53; 111-114
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of the propagation of methane from the longwall goaf, performed by means of a two-dimensional description
Modelowanie propagacji metanu ze zrobów ściany wydobywczej przy pomocy dwuwymiarowego opisu
Autorzy:
Krawczyk, J.
Janus, J.
Powiązania:
https://bibliotekanauki.pl/articles/220340.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
zagrożenie metanowe
ściana wydobywcza
opis dwuwymiarowy
stany przejściowe
przepływ turbulentny
symulacja z adaptacją skali
methane hazard
longwall
two-dimensional description
transient states
turbulent flow
scale adaptive simulation
Opis:
The paper presents results of a research on the migration of methane from goaf into an area of a longwall ventilated by means of the U-type ventilation system. Two-dimensional models of the area in question were prepared. The models encompassed longwalls whose length was 240 m, as well as segments of the main and tailgate whose length was minimum 50 m. The geometry of the models took into account the details that could make three-dimensional models too complex. These details include: the ribs of the arch support of the headings, frictional and hydraulic props, and the ribs of a section of the longwall powered roof support. Additionally, the presence of gaps between the support sections, by means of which an exchange of gases between the longwall and the adjacent goaf could take place - was taken into consideration. Using the 2D description method, an analysis of the flow of air in the area was carried out. The simulation results were shown as profiles of velocity and streamlines in surrounding of intersections of longwall. with main and tailgate Then, the grid depenadncy of numerical solutions was investigated. This was done by comparing results for three grid densities. The process of methane propagation was simulated for shearer located at two-thirds of the longwall length. The fields of methane concentrations for a steady inflow from goaf were calculated. Subsequently, the effects of a sudden inflow of methane along a segment comprising ten recently advanced roof support sections were computed. The results were presented as a sequence of concentration distributions for selected simulation moments.
Rozpatrywano migrację metanu ze zrobów do wyrobisk rejonu ściany przewietrzanego w systemie na U. Przygotowano dwuwymiarowe modele rejonu ściany obejmujące ściany o długości 240 m i odcinki chodników ścianowych od długościach co najmniej 50 m. W modelach tych wprowadzono reprezentację geometrii z uwzględnieniem szczegółów, które mogą nadmiernie skomplikować modele 3D. Elementami tymi są żebra obudowy łukowej chodników, stojaki cierne i hydrauliczne oraz żebra sekcji zmechanizowanej obudowy ściany. Uwzględniono również obecność szczelin między sekcjami obudowy, poprzez które może następować wymiana gazów ze zrobami. Przeprowadzono analizę przepływu powietrza w rejonie przy pomocy opisu 2D. Wyniki symulacji pokazano w postaci profili prędkości i linii prądu w otoczeniu skrzyżowań z chodnikami pod i nadścianowym w postaci profili prędkości i linii prądu. Sprawdzono zależności rozwiązania od siatki porównując wyniki dla trzech gęstości siatki. Przeprowadzono symulacje rozpływu metanu dla położeń kombajnu w 2/3 długości ściany. Obliczono pola stężeń metanu przy stałym dopływie ze zrobów a następnie skutki nagłego dopływu na odcinku 10 ostatnio dosuniętych sekcji. Wyniki przedstawiono w formie sekwencji rozkładów stężeń dla wybranych chwil symulacji
Źródło:
Archives of Mining Sciences; 2014, 59, 4; 851-868
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza pracy zakładowej sieci elektroenergetycznej przy uwzględnieniu niepewności parametrów modelu sieci
The analysis of the operation of an industrial power network taking into account the uncertainty of network model parameters
Autorzy:
Nocoń, A.
Paszek, S.
Walczak, J.
Powiązania:
https://bibliotekanauki.pl/articles/267181.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
zakładowa sieć energetyczna
praca wyspowa
stany przejściowe
niepewność parametrów modelu
poprawa stabilności kątowej
industrial power network
work autonomously
transient states
uncertainty of the model parameters
improving the angular stability
Opis:
W artykule przedstawiono analizę pracy w wybranych stanach nieustalonych zakładowej sieci elektroenergetycznej pracującej autonomicznie i we współpracy z Krajowym Systemem Elektroenergetycznym (KSE). Założono, że w sieci zainstalowane są dwa zespoły wytwórcze: jeden z generatorem asynchronicznym a drugi z generatorem synchronicznym. Badano zachowanie się zespołów wytwórczych m.in. w następujących stanach nieustalonych: przejście sieci zakładowej od współpracy z KSE do pracy autonomicznej oraz wyłączenie zespołu asynchronicznego w czasie autonomicznej pracy sieci. W analizie uwzględniono niepewność parametrów wybranych modeli elementów sieci. Opisano zagadnienie modelowania rozrzutu parametrów modeli układów elektrycznych. Polega ono na wyznaczeniu obwiedni (pasm granicznych) rodziny przebiegów analizowanych sygnałów. Obwiednie te wyznaczano przez wielokrotne symulacje przy zmienianych w odpowiedni sposób parametrach modelu sieci. Pokazano możliwości poprawy stabilności kątowej analizowanej sieci przy zastosowaniu układów stabilizujących o odpowiedniej strukturze i optymalizowanych parametrach. Zaproponowano wprowadzenie tych układów stabilizujących do układu regulacji mocy turbiny oraz do układu wzbudzenia generatora synchronicznego.
The analysis of the operation of an industrial power network in selected transient states is presented in the paper. The network works autonomously and in cooperation with the Polish National Power System (PNPS). It was assumed that two generating units, one with an asynchronous generator and the other with a synchronous generator, were installed in the network. There was investigated the behaviour of the generating units in the following transient states: network transition from cooperation with the PNPS to autonomous operation and switching off the asynchronous unit during autonomous operation of the network. In the analysis, there was taken into account the uncertainty of the parameters of selected models of the network elements. The problem of modelling the dispersion of parameters of electrical system models is described in the paper. It consists in determining envelopes (limit bands) of a family of waveforms of the analysed signals. These envelopes were determined by multiple simulations for appropriately changed parameters of the network model. Possibilities of improving the angular stability of the analysed network using stabilizing systems with a suitable structure and optimized parameters are shown. Introduction of these stabilizing systems to the turbine governor and the synchronous generator excitation system is proposed.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 53; 79-82
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of The Operation and Improvement of the Stability of the Factory Power Network, Taking into Account the Uncertainty of the Network Model Parameters
Ocena pracy i poprawa stabilności zakładowej sieci elektroenergetycznej z uwzględnieniem niepewności parametrów modelu sieci
Autorzy:
Nocoń, A.
Paszek, S.
Walczak, J.
Powiązania:
https://bibliotekanauki.pl/articles/396948.pdf
Data publikacji:
2017
Wydawca:
ENERGA
Tematy:
factory power network
island mode network operation
transient states
uncertainty of model parameters
improvement of angular stability
zakładowa sieć energetyczna
praca autonomiczna
stany przejściowe
niepewność parametrów modelu
poprawa stabilności kątowej
Opis:
There was analysed the operation of a factory power network working in island mode and cooperating with the Polish National Power System (PNPS) in selected transient states. It was assumed that two generating units: one with an asynchronous generator, and the second with a synchronous generator, were installed in the network. The behaviour of the generating units was analysed in the following transients: transition of the factory network from cooperation with the PNPS to island mode operation and shutdown of the asynchronous unit. The analysis took into account the uncertainty of the parameters of selected models of network elements. In the paper, there is described the problem of modelling the scatter of parameters of the models of electrical systems. It consists in determining the envelopes (limit bands) for a family of waveforms of the analysed signals. These envelopes were determined using multiple simulations when changing the network model parameters in an appropriate manner. There is shown the possibility of improving the angular stability of the analysed network by the use of stabilising systems with an appropriate structure and optimised parameters. It is proposed to introduce these stabilising systems to the turbine governor and the synchronous generator excitation system. Parameters of the stabilising systems were optimised by minimising the defined quality factor of electromechanical control waveforms in the selected transient state. A genetic algorithm was used to minimise this quality factor.
Przeanalizowano pracę w wybranych stanach nieustalonych zakładowej sieci elektroenergetycznej pracującej autonomicznie i we współpracy z Krajowym Systemem Elektroenergetycznym (KSE). Założono, że w sieci zainstalowane są dwa zespoły wytwórcze: jeden z generatorem asynchronicznym, a drugi z generatorem synchronicznym. Badano zachowanie się zespołów wytwórczych m.in. w następujących stanach nieustalonych: przejście sieci zakładowej od współpracy z KSE do pracy autonomicznej oraz wyłączenie zespołu asynchronicznego. W analizie uwzględniono niepewność parametrów wybranych modeli elementów sieci. Opisano zagadnienie modelowania rozrzutu parametrów modeli układów elektrycznych. Polega ono na wyznaczeniu obwiedni (pasm granicznych) rodziny przebiegów czasowych analizowanych sygnałów. Obwiednie te wyznaczano przez wielokrotne symulacje przy zmienianych w odpowiedni sposób parametrach modelu sieci. Pokazano możliwości poprawy stabilności kątowej analizowanej sieci przy zastosowaniu układów stabilizujących o odpowiedniej strukturze i optymalizowanych parametrach. Zaproponowano wprowadzenie tych układów stabilizujących do układu regulacji mocy turbiny oraz do układu wzbudzenia generatora synchronicznego. Optymalizację parametrów układów stabilizujących przeprowadzono poprzez minimalizację zdefiniowanego wskaźnika jakości elektromechanicznych przebiegów regulacyjnych w wybranym stanie nieustalonym. Do minimalizacji tego wskaźnika jakości zastosowano algorytm genetyczny.
Źródło:
Acta Energetica; 2017, 1; 76-82
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies