Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "performance properties" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Certain Ballistic Performance and Thermal Properties Evaluation for Extruded Modified Double-base Propellants
Autorzy:
Fahd, A.
Mostafa, H. E.
Elbasuney, S.
Powiązania:
https://bibliotekanauki.pl/articles/358144.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
solid propellant
modified double-base propellant
combustion
burning rate
ballistic performance
thermal properties
Opis:
The main advantages of modified double-base (MDB) propellants are wide range of burning rates, high energy output, as well as enhanced thrust. This study reports on the effect of potential oxidizers − potassium perchlorate (KP) or ammonium perchlorate (AP), stoichiometric binary mixture of the oxidizer (KP or AP) with metal fuel (Al), and energetic nitramine (HMX) on combustion characteristics of MDB propellants. MDB propellant formulations based on these additives, constituting 10 wt.% of total mass of the MDB formulation, were manufactured by solventless extrusion process. The impact of these additives on ballistic performance particularly the burning rate as well as on the characteristic exhaust velocity of gaseous product (C*), was evaluated using small-scale ballistic evaluation test motor. KP and AP exhibit different effects; KP positively impacts the burning rate, AP positively impacts C*. Stoichiometric binary mixture of AP/Al positively impacts both the burning rate and C*; HMX substantially enhances C*. These energetic additives could alter the combustion mechanism, by thinning the induction zone, allowing the luminous flame zone to be more adjacent to the burning surface. Therefore, the combustion reaction could proceed faster. The developed MDB propellant formulations were found to be more energetic with an increase in calorific value in comparison to reference formulation (using bomb calorimeter); they exhibited similar ignition temperature by means of cook off test. DSC measurements demonstrated similar onset and maximum decomposition temperature of developed MDB propellant formulations to reference DB propellant formulation but with an increase in total heat released (J/g).
Źródło:
Central European Journal of Energetic Materials; 2017, 14, 3; 621-635
1733-7178
Pojawia się w:
Central European Journal of Energetic Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Audyt energetyczny budynku według obowiązujących przepisów
Energy audit in accordance with the existing regulations
Autorzy:
Szmolke, N.
Powiązania:
https://bibliotekanauki.pl/articles/104827.pdf
Data publikacji:
2017
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
termomodernizacja
świadectwo charakterystyki energetycznej budynku
właściwości cieplne
przegroda budowlana
temperatura obliczeniowa
thermal renovation
energy performance certificate
thermal properties
building partitions
design temperature
Opis:
Audyt energetyczny to „opracowanie określające zakres oraz parametry techniczne i ekonomiczne przedsięwzięcia termomodernizacyjnego, ze wskazaniem rozwiązania optymalnego, w szczególności z punktu widzenia kosztów realizacji tego przedsięwzięcia oraz oszczędności energii, stanowiące jednocześnie założenia do projektu budowlanego”. W nawiązaniu do tej definicji, zaczerpniętej z Ustawy o wspieraniu termomodernizacji i remontów, w pracy omówiono szczegółową zawartość audytu energetycznego budynku, wykonanego według aktualnie obowiązujących przepisów. Wymagana zawartość audytu energetycznego oraz procedury jego wykonania znajdują się w Rozporządzeniu Ministra Infrastruktury z dnia 17 marca 2009r. w sprawie szczegółowego zakresu i form audytu energetycznego oraz części audytu remontowego, wzorów kart audytów, a także algorytmu oceny opłacalności przedsięwzięcia termomodernizacyjnego. W artykule przedstawiono etapy wykonania takiego opracowania. Szczególny nacisk położono na znaczenie poprawnie przeprowadzonej inwentaryzacji. W artykule wskazano również na zmiany w obowiązującym prawie, a szczególnie na dynamicznie zmieniające się przepisy, dotyczące izolacyjności przegród. Zwrócono uwagę na stosowanie Polskich Norm, które oficjalnie są wycofane z użycia. Dotyczy to szczególnie wartości temperatur obliczeniowych: zewnętrznej oraz wewnętrznej. W publikacji zamieszczono także kilka uwag praktycznych, pozwalających na poprawne opracowanie audytu energetycznego. Podkreślono także, że audyt energetyczny nie jest charakterystyką energetyczną budynku ani jego świadectwem charakterystyki energetycznej. Aktualnie oba te dokumenty opracowywane są zgodnie z Ustawą o charakterystyce energetycznej budynków.
Energy audit is “elaboration with a set of guidelines setting forward the scope and technical and economic parameters of a thermal upgrade, including indication of an optimum solution in particular with respect to the cost of implementing this upgrade and the resulting energy savings, also providing the basis for a building project”. In connection to this definition derived from Act on supporting thermomodernization and renovation, the present paper discusses the contents of an energy audit of a building performed in accordance with the regulations in force now. The required contents of an energy audit along with the procedures applied in its implementation are contained in The Regulation of the Minister of Infrastructure of 17 March, 2009 and relate to the scope and form of an energy audit and parts of a renovation audit, templates of audit cards, as well as an algorithm applied for the evaluation of the profitability of a thermal upgrade undertaking. The paper also contains the list of stages in such an elaboration. An emphasis was placed on the importance of an adequately performed inventory. This paper also indicates the recent changes in the legislation, in particular with regard to the dynamic changes in the laws in the area of insulation parameters of construction partitions. The common application of Polish Norms is remarked despite the fact that they are no longer officially binding. This in particular concerns the calculation of temperatures: external and internal. Besides, this paper includes a number of practical issues, whose purpose is to ensure the correct development of an energy audit. It is indicated that the energy audit is not synonymous with the characteristic of energy efficiency of a building nor with an energy performance certificate. At present, both documents are drafts under development in accordance with the Act on the energy performance of buildings.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2017, 64, 1; 441-447
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of thermal bridges on the thermal properties of new-type piggeries structures
Wpływ mostów cieplnych na właściwości termiczne konstrukcji nowych budynków chlewni
Autorzy:
Junga, P.
Trávniček, P.
Dobek, T. K.
Mareček, J.
Powiązania:
https://bibliotekanauki.pl/articles/93388.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
piggery
new building
thermal properties
thermal bridge
energy performance
infrared thermography
chlewnia
nowa chlewnia
właściwości termiczne
mostki termiczne
wydajność energetyczna
termografia w podczerwieni
Opis:
Pig production has high energy consumption thus the energy efficiency of a building is very important. The objective of this paper is a qualitative and quantitative evaluation of thermal properties and thermal bridges in the structure of a newly constructed piggery. The results prove unsuitable thermal properties of the majority of structures. Characteristic thermal properties: external walls (UT=0.470 W˖m-2˖K-1), flooring (UT=1.356 W˖m-2˖K-1), ceiling (UT=0.229 W˖m-2˖K-1), windows and doors (UT=1.70 W˖m-2˖K-1). Qualitative detection of thermal defects with utilization of infrared thermography claimed the most significant thermal bridges on uninsulated socle and flooring, steel concrete straining band of the wall, bearing steel roof frames and window and door frames. The energy efficiency of buildings is significantly affected by the built structure properties and some structures of the measured buildings had low thermal insulation and caused high heat losses.
Chów trzody chlewnej związany jest z wysokim poborem energii, dlatego też wydajność energetyczna budynku jest bardzo ważna. Celem niniejszego artykułu jest jakościowa i ilościowa ocena właściwości cieplnych oraz występowania mostków cieplnych w konstrukcji nowo wybudowanej chlewni. Charakterystyczne właściwości termiczne: ściany zewnętrznej (UT = 0,470 W˖m-2˖K-1), podłogi (UT=1,356 W˖m-2˖K-1), sufitu (UT=0,229 W˖m-2˖K-1) oraz okna i drzwi (UT=1,70 W˖m-2˖K-1).Wyniki potwierdzają nieodpowiednie właściwości termiczne większości konstrukcji. Jakościowa ocena wad cieplnych z wykorzystaniem termografii w podczerwieni umożliwia identyfikację najbardziej znaczących mostków cieplnych, występujących przede wszystkim na nieizolowanych cokołach i podłogach. Nasze badania potwierdzają, że nowoczesne konstrukcje umożliwiają wprowadzanie nowych rozwiązań technicznych oraz technologii, które poprawiają charakterystyki energetyczne budynków inwentarskich.
Źródło:
Agricultural Engineering; 2014, 18, 4; 91-101
2083-1587
Pojawia się w:
Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies