Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "thermal power" wg kryterium: Temat


Wyświetlanie 1-11 z 11
Tytuł:
The fresh waters of the Krakow region as the lower source for heat pumps
Autorzy:
Uliasz-Misiak, B.
Winid, B.
Chodań, E.
Powiązania:
https://bibliotekanauki.pl/articles/299054.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
groundwater
heat pump
temperature
thermal power
Krakow
Opis:
Krakow is a city facing a big problem with air pollution, the use of energy accumulated in groundwater may contribute to reducing emissions of gases and dust to the atmosphere. The article analyzes the possibilities of using groundwater made available with intakes located in Krakow. Estimated water temperatures were ranging from 7.9 to 9.7°C. The thermal power that can be obtained in groundwater varies for individual intakes and allows for obtaining thermal outputs from 0.395 to 1108.035 kW, according to calculations. The analysis of groundwater chemistry in the Krakow region and their comparison with the recommendations of heat pump manufacturers indicates that the use of water as a lower heat source may in some cases cause technical problems.
Źródło:
AGH Drilling, Oil, Gas; 2018, 35, 1; 187-200
2299-4157
2300-7052
Pojawia się w:
AGH Drilling, Oil, Gas
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The demand analysis of the biogas plant with chp system on substrate, the aim to obtain required electrical and thermal power
Autorzy:
Piętak, A.
Meus, M.
Nitkiewicz, S.
Powiązania:
https://bibliotekanauki.pl/articles/246798.pdf
Data publikacji:
2012
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
biogas
biogas plant
cogeneration
electrical power
renewable energy
thermal power
transportation
Opis:
Due to the ending resources of fossil fuels, as well as instability of the political situation on the world, especially in countries that are their main supplier, governments of poor countries in resources are forced to seek alternative sources of energy. Currently the most commonly used raw material to produce an electrical and thermal power in Poland are coal and lignite, However, in a result of an increase of their prices and an exacerbated by the EU of regulations about an emission of the greenhouse gas, emerged trends, that aim to transform the energy sector through the implementation of technologies based on alternative energy sources. The main focus is to put on renewable energy sources. The methodology, which is contained in this paper, presents a way to designation the demand of the biogas plant with CHP system on substrate of agricultural origin, the aim to obtain required electrical and thermal power. Moreover, the paper presents a simplified diagram of anaerobic fermentation, which is the basis of biogas production, as well as an illustrative diagram of a biogas plant with CHP system. In this paper also was mentioned the possibility of application biogas for transportation purposes.
Źródło:
Journal of KONES; 2012, 19, 3; 334-344
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody arkhitekturno-stroitel'nykh reshenijj teplovaja effektivnost' zdanijj
Methods of architectural and construction solutions and thermal effectiveness of buildings
Autorzy:
Kulikov, G.
Kaz'mina, A.
Powiązania:
https://bibliotekanauki.pl/articles/77512.pdf
Data publikacji:
2014
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
thermal effectiveness
solar energy
climatic factor
building parameter
microclimate
thermal power
thermal balance
Źródło:
Motrol. Motoryzacja i Energetyka Rolnictwa; 2014, 16, 5
1730-8658
Pojawia się w:
Motrol. Motoryzacja i Energetyka Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Effect of Structure on Thermal Power of Cast-iron Heat Exchangers
Autorzy:
Mróz, M.
Orłowicz, A. W.
Tupaj, M.
Jacek-Burek, M.
Radoń, M.
Kawiński, M.
Powiązania:
https://bibliotekanauki.pl/articles/382256.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat exchanger
gray cast iron
thermal power
wymiennik ciepła
żeliwo szare
ciepło
Opis:
The objective of the study reported in this paper was to determine the effect of structure on thermal power of cast-iron heat exchangers which in this case were furnace chambers constituting the main component of household fireplace-based heating systems and known commonly as fireplace inserts. For the purpose of relevant tests, plate-shaped castings were prepared of gray iron with flake graphite in pearlitic matrix (the material used to date typically for fireplace inserts) as well as similar castings of gray cast iron with vermicular graphite in pearlitic, ferritic-pearlitic, and ferritic matrix. For all the cast iron variants of different structures (graphite precipitate shapes and matrix type), calorimetric measurements were carried out consisting in determining the heat power which is quantity representing the rate of heat transfer to the ambient environment. It has been found that the value of the observed heat power was affected by both the shape of graphite precipitates and the type of alloy matrix. Higher thermal power values characterize plate castings of gray iron with vermicular graphite compared to plates cast of the flake graphite gray iron. In case of plates made of gray cast iron with vermicular graphite, the highest values of thermal power were observed for castings made of iron with ferritic matrix.
Źródło:
Archives of Foundry Engineering; 2020, 20, 1; 27-30
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ ożebrowania rury na warunki wymiany ciepła przy konwekcji swobodnej w powietrzu
The influence of fins on heat transfer performance under free convection in air
Autorzy:
Tychanicz-Kwiecień, Maria
Mazur, Aleksandra
Gil, Paweł
Gałek, Rafał
Powiązania:
https://bibliotekanauki.pl/articles/195178.pdf
Data publikacji:
2019
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
powierzchnie ożebrowane
przenikanie ciepła
konwekcja swobodna
moc cieplna
fins
heat transfer
free convection
thermal power
Opis:
Artykuł przedstawia wstępne wyniki pomiarów cieplnych rurowego wymiennika ciepła typu woda–powietrze, wykonanego z odcinków rur gładkich oraz ożebrowanych z żebrami śrubowymi. Stanowisko pomiarowe znajduje się na wyposażeniu Zakładu Termodynamiki Wydziału Budowy Maszyn i Lotnictwa Politechniki Rzeszowskiej. Dokonano pomiarów mocy cieplnej traconej przez przenikanie na rurze gładkiej oraz ożebrowanej w funkcji różnicy temperatury wody wlotowej i temperatury otoczenia oraz współczynników przenikania ciepła: rury gładkiej – odniesionego do powierzchni zewnętrznej oraz dla rury ożebrowanej – odniesionego do powierzchni całkowitej ożebrowania. Wyniki pomiarów wskazują, że moc cieplna rozpraszana do otoczenia wzrasta niemal trzykrotnie w wyniku zastosowania ożebrowania w stosunku do powierzchni gładkiej. Z kolei współczynnik przenikania ciepła określony dla rury gładkiej osiągnął wartość wielokrotnie większą niż dla rury ożebrowanej.
The article presents preliminary results of thermal parameter measurements of an air-water tubular heat exchanger made of smooth- and finned pipes. The experimental set-up is the equipment of The Department of Thermodynamics at Rzeszow University of Technology. The following parameters have been measured as a function of temperature difference between inlet water temperature and ambient temperature: dissipated thermal power for smooth- and finned pipes and the heat transfer coefficient for a smooth pipe related to the external surface and heat transfer coefficient for a finned pipe related to the overall finned surface. The results indicate that dissipated thermal power increased almost three times for the finned pipe with regard to the smooth pipe. The heat transfer coefficient obtained for a smooth pipe was considerably greater than for a finned pipe.
Źródło:
Zeszyty Naukowe Politechniki Rzeszowskiej. Mechanika; 2019, z. 91 [299], 1-2; 93-107
0209-2689
2300-5211
Pojawia się w:
Zeszyty Naukowe Politechniki Rzeszowskiej. Mechanika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Microstructure and Heat Transfer Surface on the Thermal Power of Cast Iron Heat Exchangers
Autorzy:
Mróz, M.
Orłowicz, A. W.
Tupaj, M.
Lenik, M.
Kawiński, M. J.
Kawiński, M.
Powiązania:
https://bibliotekanauki.pl/articles/2079819.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
vermicular cast iron
heat exchanger
thermal power
calorimetric test
żeliwo wermikularne
wymiennik ciepła
moc cieplna
test kalorymetryczny
Opis:
The paper presents the results of calorimetric tests of segment elements of fireplace inserts. The aim of the work was to optimize their thermal power by replacing the previously used gray cast iron with flake graphite with gray iron with vermicular graphite and replacing the existing geometry of the heat transfer surface with a more developed one. It turned out that the thermal power of the test segments made of cast iron with vermicular graphite was higher compared to the segments of the same shape made of gray cast iron with flake graphite. It was found that the use of segments made of vermicular cast iron with a ferritic matrix allowed for an increase in the thermal power value by dozen percent, compared to segments of the same shape made of vermicular cast iron with a pearlitic matrix. The test results showed that the thermal power of the test segments depends on the variant of the development of both the heat receiving surface and the heat giving off surface. The highest value of the thermal power was obtained when ribbing in the form of a lattice was used on both of these surfaces, and the lowest when using flat surfaces.
Źródło:
Archives of Foundry Engineering; 2021, 21, 4; 93-96
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heat power determination of Dv-290 refrigerator’s evaporator on the basis of thermodynamic parameters of inlet air
Określenie mocy cieplnej parownika chłodziarki Dv-290 na podstawie parametrów termodynamicznych powietrza wlotowego
Autorzy:
Nowak, B.
Kuczera, Z.
Powiązania:
https://bibliotekanauki.pl/articles/218808.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
klimatyzacja kopalń
chłodzenie powietrza
chłodziarka sprężarkowa
moc cieplna
air conditioning of mines
air cooling
compression refrigerator
thermal power
Opis:
The present paper introduces a method for calculating the thermal power of DV-290 mining air cooler’s evaporator. The power usually differs from the nominal power given by the manufacturer. The thermodynamic parameters of cooled air are not obtained as a result of in situ measurements, but in indirect manner that is by determining the evaporation and condensation’s pressure values of R407C refrigerant. The pressure dependencies formulated as a function of air enthalpy at the evaporator’s inlet were obtained using calculations of a computer program which solves the system of equations describing heat and mass transfer in the refrigerator’s compressor on the basis of previous measurements of air performed before and after its cooling. The obtained dependencies are demonstrated in a graphical (fig. 2 and fig. 3) and analytical (the regression equations (19) and (20)) manner, the values of correlation coefficients are also presented. For the known evaporation and condensation pressure values of the refrigerant, and thus for its basic physical parameters the complete thermal power of the evaporator was determined, that is its: air cooling overt power, dehumidification occult power, temperature, relative humidity and specific humidity of air after its cooling. In addition, using the mentioned method, the capacity of DV-290 refrigerator’s evaporator is provided for the given thermodynamic parameters of air before cooling, along with air thermodynamic parameters after cooling.
W pracy zaproponowano metodę obliczania mocy cieplnej parownika górniczej chłodziarki powietrza DV-290. Moc ta zazwyczaj jest różna od mocy znamionowej podanej przez jej producenta. Wymaganą znajomość parametrów termodynamicznych schłodzonego powietrza otrzymuje się, nie jak dotychczas w wyniku ich pomiarów in situ, lecz drogą pośrednią wyznaczając najpierw wartości ciśnień parowania i skraplania czynnika chłodniczego R407C. Odpowiednie zależności tych ciśnień w funkcji jednostkowej entalpii powietrza na wlocie parownika otrzymano, na podstawie wcześniejszych pomiarów parametrów powietrza przed i po jego schłodzeniu, z obliczeń utworzonym programem komputerowym rozwiązującym układ równań opisujący wymianę ciepła i masy w chłodziarce sprężarkowej. Uzyskane zależności przedstawiono w sposób graficzny (rys. 2 i rys. 3) oraz analityczny - równania regresji (19) i (20), podając też wartości współczynników korelacji. Dla znanych wartości ciśnień parowania i skraplania czynnika chłodniczego, a więc także i jego podstawowych parametrów fizycznych, korzystając z wymienionego programu komputerowego, wyznaczono, w funkcji jednostkowej entalpii powietrza na wlocie parownika, całkowitą jego moc cieplną z podziałem na moc jawną ochładzania powietrza, utajoną moc osuszania powietrza, temperaturę, wilgotność względną i wilgotność właściwą powietrza po jego ochłodzeniu. Podano też, dla przykładowych zadanych parametrów termodynamicznych powietrza przed jego schłodzeniem obliczone wspomnianą metodą, moce parownika chłodziarki DV-290 oraz parametry termodynamiczne powietrza po schłodzeniu.
Źródło:
Archives of Mining Sciences; 2012, 57, 4; 911-920
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Analysis of Thermal Properties of Selected Rock Materials by Thermovision Methods
Analiza właściwości cieplnych wybranych surowców naturalnych, na podstawie badań wykorzystujących metody termowizyjne
Autorzy:
Stempkowska, A.
Izak, P.
Mastalska-Popławska, J.
Staszewska, M.
Powiązania:
https://bibliotekanauki.pl/articles/319117.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
ciepło właściwe minerałów
emisja ciepła
termiczne właściwości skał
moc cieplna
termowizja
minerals specific heat capacity
heat emission
rocks thermal properties
thermal power
thermovision
Opis:
Heat accumulation means denotes the of a material to collect and store inside a specific amount of thermal energy, which can be then returned for a period time from the material. There are many investigations devoted to finding a method to collect heat when there is an excess and to use it when there is a deficit. The parameter determining whether the returned heat long for a term will have an impact on the room temperature, is the time of emission of stored energy. For the specified amount of stored energy, the emission time cannot be too short (in such a case too much heat in the unit time is returned) or too long (in this case a too small amount of heat in the time unit is returned, for example insufficient for heating rooms). The main aim of this research is to investigate the behavior (during cooling) of natural rock materials. On the basis of research and performed calculations the evaluation of tested materials to serve as the heat accumulator was performed. This analysis would allow them to be applied for the production of components, including precast, working at elevated temperatures, in which the accumulation and transfer of heat is important (eg. housing furnaces and fireplaces).
Akumulacja ciepła oznacza zdolność materiału do gromadzenia i magazynowania w jego wnętrzu określonej porcji energii cieplnej, która następnie może być przez pewien okres czasu przez ten materiał oddawana. Szuka się więc sposobów gromadzenia ciepła wtedy, gdy jest jego nadmiar oraz wykorzystania, gdy występuje deficyt. Parametrem, decydującym o tym czy oddający ciepło materiał w sposób długotrwały będzie oddziaływał na temperaturę pomieszczenia, jest czas oddawania (emisji) zgromadzonej energii. Przy danej ilości zgromadzonej energii, czas jej emisji nie może być zbyt krótki (wtedy w jednostce czasu oddawane są zbyt duże ilości ciepła) ani zbyt długi (wtedy w jednostce czasu oddawane są zbyt małe ilości ciepła, niewystarczające np. do ogrzania pomieszczenia). W niniejszej pracy zrelacjonowano eksperyment polegający na badaniu zachowania się, podczas studzenia, naturalnych surowców mineralnych. Na tej podstawie badań oraz wykonanych obliczeń oceniono jego zdolność do akumulacji cieplnej. Pozwoliłoby to na stosowanie ich do wytwarzania elementów, w tym prefabrykatów, pracujących w podwyższonych temperaturach, gdzie jest istotna akumulacja i oddawanie ciepła (np. obudowy palenisk i komików).
Źródło:
Inżynieria Mineralna; 2018, R. 20, nr 2, 2; 337-344
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the influence of the heat-absorbing surface of an air-cooled solar collector on its thermal and mechanical properties
Autorzy:
Zhelykh, Vasyl
Ulewicz, Małgorzata
Kozak, Krystyna
Savchenko, Olena
Kasynets, Mariana
Powiązania:
https://bibliotekanauki.pl/articles/88616.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
solar air collector
heat-absorbing plate
flow turbulators
thermal power
air channel
powietrzny kolektor słoneczny
płyta pochłaniająca ciepło
turbulatory przepływowe
energetyka cieplna
kanał powietrzny
Opis:
This paper presents the analysis of existing forms of heat absorbing surfaces of air solar collectors, which gained the greatest popularity in the world. The obtained data allowed to conclude that there is a need for the development of solar collectors with air as a coolant with an improved form of heat absorber, which will reduce the operational and capital costs of solar systems and allow the efficient use of such structures in a moderate climate without additional mechanisms for the transfer of coolant. The use of computer simulation helped to compare the thermal characteristics of air-borne solar collectors of a different design. The substantiation of the expediency of installing as a heat absorber of flow turbulators in the form of a screw has been fulfilled, as well as the height of the air channel of the solar collector has been determined, in which the maximum heating of the transfer medium is observed. In addition, the loss of pressure in the air channel of the solar collector with flow turbulators was determined and the comparison of the obtained data with the values of pressure losses in the air collector of the matrix type and the air collector with V-shaped ribs was made.
Źródło:
System Safety : Human - Technical Facility - Environment; 2019, 1, 1; 481-489
2657-5450
Pojawia się w:
System Safety : Human - Technical Facility - Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energetyka jądrowa – konieczność, a nie zagrożenie
Nuclear power – a necessity, not a threat
Autorzy:
Domański, Roman
Powiązania:
https://bibliotekanauki.pl/articles/2176255.pdf
Data publikacji:
2022
Wydawca:
Mazowieckie Biuro Planowania Regionalnego w Warszawie
Tematy:
promieniowanie
rozpad promieniotwórczy
reaktor jądrowy
chłodziwo
moderator
moc cieplna
moc elektryczna
awaria
obieg parowy
paliwo jądrowe
sprawność
radiation
radioactive decay
nuclear reactor
coolant
thermal power
electrical power
failure
steam cycle
nuclear fuel
efficiency
Opis:
W pracy przedstawiono w skrócie potrzeby energetyczne świata, podział zużycia energii pierwotnej z punku widzenia paliw oraz 3 podstawowe scenariusze rozwoju świata prezentowane przez Międzynarodową Agencję Energii. Omówiono podstawowe procesy dotyczące wytwarzania energii jądrowej i jej konwersji na energię wewnętrzną. Przedstawiono najważniejsze typy reaktorów jądrowych podając ich podstawowe parametry pracy. W posumowaniu przedstawiono zasadnicze wnioski.
The work briefly outlines the world's energy needs, the division of primary energy consumption from a fuel perspective and the three basic world development scenarios presented by the International Energy Agency. The basic processes of nuclear power production and its conversion into internal energy are discussed. The most important types of nuclear reactors are presented with their basic operating parameters. The basic conclusions are presented in the summary.
Źródło:
MAZOWSZE Studia Regionalne; 2022, 42; 25-60
1689-4774
Pojawia się w:
MAZOWSZE Studia Regionalne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the Thermal Power of Groundwater Intakes in The Kielce District
Autorzy:
Nartowska, Edyta
Budzianowski, Dominik
Styś-Maniara, Marta
Powiązania:
https://bibliotekanauki.pl/articles/27314854.pdf
Data publikacji:
2022
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
low-temperature geothermal energy
RES
thermal power
energy efficiency index
groundwater intake
heat pump
geotermia niskotemperaturowa
OZE
moc cieplna
wskaźnik efektywności energetycznej
ujęcie wód podziemnych
pompa ciepła
Opis:
The purpose of the article was to estimate the thermal power of groundwater intakes of the Kielce district within the sheets of hydrogeological maps with the serial numbers MHP 813-817, MHP 850-851, and to indicate in this area prospective areas for the development of low-temperature geothermal energy supported by water/water heat pumps. Based on the calculations on the basis of 147 groundwater intakes, it was determined that the estimated values of thermal power resources are in the range of 3.47 kW to 5757.34 kW. The created map of the low-temperature geothermal potential for groundwater intakes indicates the towns of Bodzentyn, Morawica and the villages of Piekoszów, Wolica and the area around the village of Górno as prospective areas.
Źródło:
Civil and Environmental Engineering Reports; 2022, 32, 4; 25--49
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-11 z 11

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies