Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "destructive tests" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Determination of the strength parameters of pinewood based on the non-destructive sclerometric test with a wood hammer
Autorzy:
Szostak, Bartosz
Trochonowicz, Maciej
Kowalczyk, Mateusz
Powiązania:
https://bibliotekanauki.pl/articles/396645.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
pinewood
non-destructive tests
sclerometric test
compressive strength
drewno sosnowe
testy nieniszczące
testy sklerometryczne
wytrzymałość na ściskanie
Opis:
To assess the technical condition of a structure and design it using existing elements, it is necessary to know its parameters. For existing facilities, it is often not possible to get a sample of material and examine it directly in the laboratory. For this reason, in situ nondestructive testing is very important. The main goal of the paper is to present the issues related to determining the strength parameters of a particular wood based on the non-destructive sclerometric test performed with a wood sclerometric hammer. The study also presents the results of the impact of pinewood density on its compressive strength.
Źródło:
Civil and Environmental Engineering Reports; 2020, 30, 1; 43-52
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indirect measure of corrosion level based on crack opening
Pośrednia miara stopnia korozji bazująca na rozwarciu rysy
Autorzy:
Bossio, A.
Montuori, M.
Bellucci, F.
Lignol, G.P.
Protas, A.
Cosenza, E.
Manfredir, G.
Powiązania:
https://bibliotekanauki.pl/articles/218376.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Konserwatorów Zabytków
Tematy:
RC structures
corrosion
assessment
crack width
design charts
non-destructive tests
konstrukcje żelbetowe
korozja
oszacowanie
szerokość rysy
nomogramy
testy nieniszczące
Opis:
Reinforced concrete (RC) is a widely used material since about 100 years. The early degradation of RC structures has led to intervene on them. Main causes of degradation are carbonation, chlorides and sulphides attacks. Even if diffusion of RC structures is quite recent, however historical and cultural heritage constructions are also made of RC. To preserve the historic value of such structures could require minimally invasive measures aimed at long-term safeguarding, if they are well designed; but it is important to evaluate material characteristics. For this purpose it is necessary to use non destructive tests (NDT) to evaluate the level of degradation reached by the materials composing the structures. Main electrochemical NDT are measurement of corrosion rate and open circuit potential. The use of such techniques requires the removal of small portions of concrete cover only. They, indirectly, allow the value of corrosion penetration to be evaluated. Previous studies provided analytical models to assess crack initiation and propagation according to different values of concrete strength, concrete cover, bar diameter and type of aggregates. Such models better perform for new buildings because historic structures are usually expected to present a visible crack pattern. This paper presents another tool in the box of practitioners to assess and evaluate the vulnerability of existing structures. In particular proposed model provides bar reduction in terms of diameter or cross sectional area, depending on actual crack opening. Outputs of the paper are design charts providing direct correlation between crack width and steel reinforcement loss depending on few geometrical dimensions of RC elements.
Beton zbrojony (RC) jest powszechnie stosowanym materiał od około 100 lat. Głównymi przyczynami degradacji jest nasycenie dwutlenkiem węgla, chlorki i atak siarczki. Pomimo, że dyfuzja konstrukcji żelbetowych jest stosunkowo nowa, konstrukcje dziedzictwa historycznego i kulturowego są także są wykonane z betonu zbrojonego. Aby zachować zabytkową wartość takich struktur wymagana jest długoterminowe zabezpieczenie. W tym celu konieczne jest użycie testów destrukcyjnych (NDT) do oceny stopnia degradacji. Bardzo ważny jest pomiar szybkości korozji i potencjał otwartego obwodu. Stosowanie takich technik wymaga usunięcia jedynie małej części otuliny.
Źródło:
Wiadomości Konserwatorskie; 2013, 34; 36-40
0860-2395
2544-8870
Pojawia się w:
Wiadomości Konserwatorskie
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies