Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "suspended load" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Sedimentation of load in a step-pool rock ramp fishway with biotechnical embedded elements
Autorzy:
Tymiński, T.
Mumot, J.
Karpowicz, D.
Jianxin, X.
Powiązania:
https://bibliotekanauki.pl/articles/108516.pdf
Data publikacji:
2017
Wydawca:
Instytut Meteorologii i Gospodarki Wodnej - Państwowy Instytut Badawczy
Tematy:
fishway
biotechnical embedded elements
suspended load
transport of sediment
Opis:
such structures has resulted in a more and more conventional approach to their design. However, every single hydraulic engineering structure with a negative impact on the possibility of a watercourse in fact requires an individual approach. Often, the solutions which are the most convenient and the easiest for a designer are not in the least the best ones for migratory fish. Semi-natural fishways in particular pose a technical challenge that requires an interdisciplinary approach. Designing and constructing them correctly is not an easy task, but once it is achieved, the structure is highly effective in terms of fish migration and the formation of new habitats. Another, equally important issue related to fishways of this type is their long-term usage and proper maintenance. In this case, it is crucial to consider the transport of load through the fishway channel, and more particularly its sedimentation in zones of lower flow velocities. This paper presents a qualitative analysis of the sedimentation of load based on laboratory research carried out on a model of a vegetated fishway. This research was performed to investigate and confirm the expected locations of accumulation of load in a semi-natural vegetated step-pool rock ramp fishway. Experiments show that the sedimentation of load in fish passes may be a highly problematic issue and may require that more attention be given to the proper upkeep of fishways. It may be necessary to address the problem of fishway maintenance and deal with fishways as structures that change over time not only because of hydrological conditions, but also due to the yearly growth cycle of vegetation.
Źródło:
Meteorology Hydrology and Water Management. Research and Operational Applications; 2017, 5, 2; 35-42
2299-3835
2353-5652
Pojawia się w:
Meteorology Hydrology and Water Management. Research and Operational Applications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Features of the Sediment Runoff Regime Downstream the Ile River
Autorzy:
Duskayev, Kassym
Myrzakhmetov, Akhan
Zhanabayeva, Zhanar
Klein, Igor
Powiązania:
https://bibliotekanauki.pl/articles/125037.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
sediment transport
sediment runoff characteristic
suspended load
bed load
granulometric composition
Opis:
This paper is devoted to study on the sediment runoff of the Ile River downstream. The article analyses the Kapshagai reservoir impact on the regime and characteristics of the sediment runoff in the Ile River downstream before and after construction of the reservoir in 1970. Along with the calculation of characteristics of sediment runoff, an assessment of the amount of the suspended sediment, which is in the bowl of the reservoir, was shown. Furthermore, the impact reservoir on the granulometric composition of the suspended and bed sediment of Ile River was calculated.
Źródło:
Journal of Ecological Engineering; 2020, 21, 2; 117-125
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A two-decade record of variations in suspended sediment in the Warta River, a lowland river in western Poland
Autorzy:
Skolasińska, Katarzyna
Nowak, Bogumił
Bradtke, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/2060129.pdf
Data publikacji:
2020
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
suspended sediment concentration
suspended load
long-term record
anthropogenic impact
lowland river
Warta River
Opis:
Fluctuations in suspended sediment concentration (SSC) has been investigated in the Warta River(western Poland), based on data obtained for the period 1961-1980 from three gauge stations located in upstream, middle-stream and downstream areas. Over the two decades, the SSC values demonstrated wide fluctuations and an overall increase at each gauge station. No significant correlation was generally observed between SSC and discharge but high SSC was found to follow low discharge and increasing temperature during the summer seasons in some years. Measurements of SSC and discharge were used to estimate total annual suspended sediment load (SSL). SSL values were found to increase downstream along with an increase in discharge. SSC decreases along the river course. However, when it comes to changes over time, SSL variability was mainly determined by SSC changes. The maximum SSC values were primary caused by anthropogenic factors: the disposal of mine wastewater upstream, river training works, increased urbanisation and the intensification of sewage disposal. Where the river catchment has been greatly affected by anthropogenic factors, a denudation index calculated solely based on SSC and discharge does not appear to reflect the actual denudation rate, and must be treated with caution.
Źródło:
Geological Quarterly; 2020, 64, 4; 1048--1060
1641-7291
Pojawia się w:
Geological Quarterly
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ obciążenia podwieszonego za pomocą łączników jednostronnych na nośność płyt warstwowych
Influence of suspended loads using blind rivets on the load capacity of the sandwich panels
Autorzy:
Studziński, Robert
Ciesielczyk, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/129047.pdf
Data publikacji:
2020
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
łącznik jednostronny
obciążenie podwieszone
rozciąganie
okładzina płyty
płyta warstwowa
nośność
blind rivet
suspended load
tensioning
panel facing
sandwich panel
load capacity
Opis:
W artykule zostały omówione wyniki badań doświadczalnych przedstawiające wpływ podwieszenia obciążenia zewnętrznego do rozciąganej okładziny płyty warstwowej na nośność tych płyt. Podwieszenie zostało zrealizowane za pomocą łączników jednostronnych (ang. blind rivets). W tym celu zostały wykorzystane nity rozchylne BulbTite. W praktyce połączenie z wykorzystaniem łączników jednostronnych jest połączeniem nieprzelotowym, tj. nie wymaga stosowania podkonstrukcji i nie tworzy punktowych mostków termicznych. W badaniach posłużono się schematem belki czteropunktowo zginanej. Badanie obejmowało kilka poziomów obciążenia podwieszonego oraz jego wpływ na belki warstwowe z rdzeniem wykonanym z pianki poliuretanowej, z wełny mineralnej i styropianu. W wyniku przeprowadzonych badań określono siły niszczące, sztywności sieczne i mechanizmy zniszczenia badanych elementów warstwowych.
The article discusses the results of experimental tests presented the impact of suspended loads to the tensioned sandwich panel facing on the load capacity of these panels. The blind rivets were used to suspend the loads. For this purpose, BulbTite rivets were used. In practice, this type of connection is called the blind connection i.e. it does not require the use of a secondary structure and does not create point thermal bridges. In the research, the four-point bending static scheme was used. The study included several levels of suspended loads and its effect on sandwich beams with a core made of polyurethane foam, mineral wool, and styrofoam. As a result of the tests, the ultimate loads, the secant stiffnesses, and the failure mechanisms of the tested sandwich elements were determined.
Źródło:
Builder; 2020, 24, 3; 16-19
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies