Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "supercritical" wg kryterium: Temat


Wyświetlanie 1-8 z 8
Tytuł:
Selected aspects of operation of supercritical (transcritical) organic Rankine cycle
Autorzy:
Mocarski, S.
Borsukiewicz-Gozdur, A.
Powiązania:
https://bibliotekanauki.pl/articles/240751.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ORC
supercritical power plant
organic fluid
siłownia nadkrytyczna
płyn organiczny
Opis:
The paper presents a literature review on the topic of vapour power plants working according to the two-phase thermodynamic cycle with supercritical parameters. The main attention was focused on a review of articles and papers on the vapour power plants working using organic circulation fluids powered with low- and medium-temperature heat sources. Power plants with water-steam cycle supplied with a high-temperature sources have also been shown, however, it has been done mainly to show fundamental differences in the efficiency of the power plant and applications of organic and water-steam cycles. Based on a review of available literature references a comparative analysis of the parameters generated by power plants was conducted, depending on the working fluid used, the type and parameters of the heat source, with particular attention to the needs of power plant internal load.
Źródło:
Archives of Thermodynamics; 2015, 36, 2; 85-103
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Validation of a program for supercritical power plant calculations
Autorzy:
Kotowicz, J.
Łukowicz, H.
Bartela, Ł.
Michalski, S.
Powiązania:
https://bibliotekanauki.pl/articles/240731.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
blok nadkrytyczny
cykl parowy
walidacja
steam cycle
supercritical power plant
validation
Opis:
This article describes the validation of a supercritical steam cycle. The cycle model was created with the commercial program GateCycle and validated using in-house code of the Institute of Power Engineering and Turbomachinery. The Institute's in-house code has been used extensively for industrial power plants calculations with good results. In the first step of the validation process, assumptions were made about the live steam temperature and pressure, net power, characteristic quantities for high- and low-pressure regenerative heat exchangers and pressure losses in heat exchangers. These assumptions were then used to develop a steam cycle model in GateCycle and a model based on the code developed in-house at the Institute of Power Engineering and Turbomachinery. Properties, such as thermodynamic parameters at characteristic points of the steam cycle, net power values and efficiencies, heat provided to the steam cycle and heat taken from the steam cycle, were compared. The last step of the analysis was calculation of relative errors of compared values. The method used for relative error calculations is presented in the paper. The assigned relative errors are very slight, generally not exceeding 0.1%. Based on our analysis, it can be concluded that using the GateCycle software for calculations of supercritical power plants is possible.
Źródło:
Archives of Thermodynamics; 2011, 32, 4; 81-89
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical thermodynamic optimization of supercritical coal fired power plant with support of IPSEpro software
Autorzy:
Elsner, W.
Kowalczyk, Ł.
Marek, M.
Powiązania:
https://bibliotekanauki.pl/articles/240118.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
optymalizacja termodynamiczna
siłownia nadkrytyczna
symulacja
wydajność
efficiency
simulation
supercritical power plant
thermodynamic optimization
Opis:
The paper presents a thermodynamic optimization of supercritical coal fired power plant. The aim of the study was to optimize part of the thermal cycle consisted of high-pressure turbine and two chosen high-pressure feed water heaters. Calculations were carried out using IPSEpro software combined with MATLAB, where thermal efficiency and gross power generation efficiency were chosen as objective functions. It was shown that the optimization with newly developed framework is sufficiently precise and its main advantage is the reduction of computation time on comparison to the classical method. The calculations have shown the tendency of the increase in efficiency, with the rise of a number of function variables.
Źródło:
Archives of Thermodynamics; 2012, 33, 3; 101-110
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena ekonomiczna nadkrytycznego bloku węglowego dużej mocy zintegrowanego w różnych konfiguracjach z CCS oraz z odzyskiem ciepła ze spalin
An economic analysis of a high capacity coal-fired power unit for supercritical steam parameters integrated in different configurations with the carbon capture system (CCS) and with heat recovery from the organic Rankine cycle (ORC) exhaust gases
Autorzy:
Kochaniewicz, A.
Łukowicz, H.
Powiązania:
https://bibliotekanauki.pl/articles/172847.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
nadkrytyczny blok węglowy
CCS
ORC
odzysk ciepła
ocena ekonomiczna
supercritical power plant
heat recovery
economic assessment
Opis:
W pracy dokonano analizy wskaźników opłacalności ekonomicznej budowy bloków węglowych o parametrach nadkrytycznych opalanych węglem kamiennym i brunatnym. Przeanalizowano trzy warianty konfiguracji bloku, tj.: blok wyjściowy, blok wyjściowy+CCS i blok wyjściowy+ CCS+ORC.W analizie ekonomicznej wykorzystano tzw. próg rentowności BEP (break even point), bazującego na określeniu punktu wyrównania, określającego sytuację w której przychody ze sprzedaży energii elektrycznej pokrywają koszty stałe i koszty zmienne instalacji. Dokonano oceny wpływu zmiany wybranych parametrów takich jak: jednostkowe nakłady inwestycyjne, cena zakupu uprawnień do emisji CO2, a także wpływu ceny paliwa. Dla tych wszystkich uzmiennionych parametrów określono wpływ ich zmian na graniczną cenę sprzedaży energii elektrycznej. Analizie poddano samodzielny oraz po jego zintegrowaniu z CCS (carbon dioxide capture and storage) wysokosprawny nadkrytyczny blok węglowy o mocy 900 MW. Analizowano także wpływ integracji bloku energetycznego z siłownią ORC (organic Rankine cycle) i podjęto próbę określenia jego efektywności ekonomicznej, przy czym przyjęto, że obieg ORC zasilany jest ciepłem odpadowym ze spalin wylotowych z kotła.
This paper presents the analysis of the indices of the economic profitability of the construction of brown- and hard coal-fired power plants for supercritical steam parameters. Three variants of the power plant configuration are analysed within this study: the initial power plant, the initial power plant + CCS, the initial power plant + CCS + ORC. The economic analysis employs the break-even point (BEP), which is based on the determination of the point of balance between the income from the sale of electricity and the plant fixed and variable costs. The impact of change in selected parameters, such as investment expenditures per unit, the price of the CO2 emissions allowances and the price of fuel, is analysed. The effect of changes in all these variable parameters on the minimum selling price of electricity is determined. The analysis concerns a high efficiency 900 MW coal-fired power unit for supercritical steam parameters as the initial plant and its variant after integration with the CCS. The impact of a further integration of the power unit with an ORC plant is analysed and an attempt is made to determine the economic efficiency of such integration. It is assumed that the ORC is fed with the waste heat from the boiler exhaust gases.
Źródło:
Archiwum Energetyki; 2013, 43, 1/2; 157-169
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of technical and economic parameters of an ionic transport membrane air separation unit working in a supercritical power plant
Autorzy:
Kotowicz, J.
Michalski, S.
Balicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/185699.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
four-end type ionic transport membrane module
air separation
supercritical power plant
separacja powietrza
elektrownia nadkrytyczna
Opis:
In this paper an air separation unit was analyzed. The unit consisted of: an ionic transport membrane contained in a four-end type module, an air compressor, an expander fed by gas that remains after oxygen separation and heat exchangers which heat the air and recirculated flue gas to the membrane operating temperature (850 °C). The air separation unit works in a power plant with electrical power equal to 600 MW. This power plant additionally consists of: an oxy-type pulverized-fuel boiler, a steam turbine unit and a carbon dioxide capture unit. Life steam parameters are 30 MPa/650 °C and reheated steam parameters are 6 MPa/670 °C. The listed units were analyzed. For constant electrical power of the power plant technical parameters of the air separation unit for two oxygen recovery rate (65% and 95%) were determined. One of such parameters is ionic membrane surface area. In this paper the formulated equation is presented. The remaining technical parameters of the air separation unit are, among others: heat exchange surface area, power of the air compressor, power of the expander and auxiliary power. Using the listed quantities, the economic parameters, such as costs of air separation unit and of individual components were determined. These quantities allowed to determine investment costs of construction of the air separation unit. In addition, they were compared with investment costs for the entire oxy-type power plant.
Źródło:
Chemical and Process Engineering; 2016, 37, 3; 359-371
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exergy analysis of internal regeneration in supercritical cycles of ORC power plant
Autorzy:
Borsukiewicz-Gozdur, A.
Powiązania:
https://bibliotekanauki.pl/articles/239987.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
analiza egzergii
nadkrytyczny blok węglowy
ORC
regeneracja ciepła
exergy analysis
internal heat regeneration
supercritical power plant
Opis:
In the paper presented is an idea of organic Rankine cycle (ORC) operating with supercritical parameters and so called dry fluids. Discussed is one of the methods of improving the effectiveness of operation of supercritical cycle by application of internal regeneration of heat through the use of additional heat exchanger. The main objective of internal regenerator is to recover heat from the vapour leaving the turbine and its transfer to the liquid phase of working fluid after the circulation pump. In effect of application of the regenerative heat exchanger it is possible to obtain improved effectiveness of operation of the power plant, however, only in the case when the ORC plant is supplied from the so called sealed heat source. In the present paper presented is the discussion of heat sources and on the base of the case study of two heat sources, namely the rate of heat of thermal oil from the boiler and the rate of heat of hot air from the cooler of the dinkier from the cement production line having the same initial temperature of 260[degrees]C, presented is the influence of the heat source on the justification of application of internal regeneration. In the paper presented are the calculations for the supercritical ORC power plant with R365mfc as a working fluid, accomplished has been exergy changes and exergy efficiency analysis with the view to select the most appropriate parameters of operation of the power plant for given parameters of the heat source.
Źródło:
Archives of Thermodynamics; 2012, 33, 3; 51-63
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Increase of power and efficiency of the 900 MW supercritical power plant through incorporation of the ORC
Autorzy:
Ziółkowski, P.
Mikielewicz, D.
Mikielewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/239975.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
supercritical power plant
ORC
regeneration
thermodynamic analysis
numerical analysis
CFM
nadkrytyczny blok węglowy
regenerowanie
analiza termodynamiczna
analiza numeryczna
Opis:
The objective of the paper is to analyse thermodynamical and operational parameters of the supercritical power plant with reference conditions as well as following the introduction of the hybrid system incorporating ORC. In ORC the upper heat source is a stream of hot water from the system of heat recovery having temperature of 90˚C, which is additionally aided by heat from the bleeds of the steam turbine. Thermodynamical analysis of the supercritical plant with and without incorporation of ORC was accomplished using computational flow mechanics numerical codes. Investigated were six working fluids such as propane, isobutane, pentane, ethanol, R236ea and R245fa. In the course of calculations determined were primarily the increase of the unit power and efficiency for the reference case and that with the ORC.
Źródło:
Archives of Thermodynamics; 2013, 34, 4; 51-71
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of a supercritical power plant with an oxy type pulverized fuel boiler, a carbon dioxide capture unit and a ‘four-end’ type membrane air separator
Modelowanie elektrowni na parametry nadkrytyczne z kotłem pyłowym typu oxy, instalacją cc oraz membranowym separatorem powietrza typu ‘four-end’
Autorzy:
Kotowicz, J.
Michalski, J.
Powiązania:
https://bibliotekanauki.pl/articles/172908.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
modelowanie elektrowni
kocioł oxy
membrana typu four-end
separacja membranowa
elektrociepłownia nadkrytyczna
power plant modelling
oxy boiler
four-end membrane
membrane separation
supercritical power plant
Opis:
W artykule analizowano elektrownie o mocy 600 MW i parametrach pary świeżej 30 MPa/650 °C i wtórnej 6 MPa/670 °C. Elektrownia wyposażona jest w następujące instalacje: kocioł pyłowy typu oxy, wysokotemperaturową membranę do separacji powietrza typu ‘four-end’ oraz instalację przygotowania i sprężania CO2. Wymienione instalacje zostały zamodelowane. Przy założeniu stałej mocy brutto analizowanej elektrowni wyznaczono zapotrzebowanie na moc zamodelowanych instalacjach, sprawność obiegu parowego oraz sprawność termiczną kotła. Wielkości te wyznaczono w funkcji stopnia odzysku tlenu w membranie. Pozwoliło to wyznaczyć sprawność wytwarzania energii elektrycznej netto.
The analysis of a 600 MW supercritical power plant with parameters of life steam at 30 MPa/650 °C and of reheated steam 6 MPa/670 °C was made. Power plant is equipped with the following units: oxy type pulverized fuel boiler, ‘four-end’ high temperature membrane air separator and carbon dioxide capture system which were modeled. With the assumption of a constant gross power of the analyzed power plant, the thermal efficiency of the boiler and the steam cycle efficiency were calculated. These parameters were designated as a function of the recovery rate of oxygen in the air separation unit. This allowed to determine gross and net efficiency of electricity generation.
Źródło:
Archiwum Energetyki; 2012, 42, 2; 73-83
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies