Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "steel column" wg kryterium: Temat


Wyświetlanie 1-7 z 7
Tytuł:
Experimental investigations of concrete filled battened steel columns of different slenderness
Badania doświadczalne złożonych słupów stalowych o różnej smukłości wypełnionych betonem
Autorzy:
Siennicki, M.
Powiązania:
https://bibliotekanauki.pl/articles/230414.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
słup stalowy
słup złożony
przewiązka
przekrój wypełniony betonem
eksperyment
nośność na ściskanie
zachowanie
steel column
battened column
concrete filled section
experiment
axial strength
behaviour
Opis:
The study investigates the axial load behaviour of concrete filled battened steel columns not covered by the design standards. A series of full scale tests on two I-sections connected together with intermediate batten plates and filled with concrete were carried out. The main parameters varied in the tests are length of the members and strength of the concrete filling. One bare steel member was also tested and results were compared with those filled with concrete. The tests results were illustrated by load-strain curves. The main objectives of these tests were twofold: first, to describe behaviour of new steel-concrete columns and second, to analyze the influence of slenderness on load-carrying capacity.
W artykule przedstawiono wyniki badań doświadczalnych złożonych słupów stalowych łączonych przewiązkami, wypełnionych betonem. Elementy badawcze poddawane były ściskaniu osiowemu w prasie hydraulicznej, z założonym przyrostem. Parametrami stałymi w badaniach był rodzaj kształtowników stalowych IPE80, rozstaw gałęzi i wielkość przewiązek. Zróżnicowana była długość słupów 1.5m, 2.5m oraz 3.0m a także klasa betonu wypełniającego. Jeden z elementów dla celów porównawczych pozostał nie wypełniony betonem. W trakcie badań dokonywano pomiarów odkształceń części stalowej słupa i betonu wypełniającego w wybranych przekrojach, rejestracji skrócenia oraz wygięcia słupów, a także makroskopowej oceny zachowania się elementów pod wpływem rosnącego obciążenia oraz pomiaru maksymalnej siły obciążającej. Zaobserwowano trzy główne postaci zniszczenia słupów, polegające na pękaniu i miażdżeniu betonu, z jednoczesnych lokalnym wyboczeniem profili stalowych w przypadku słupów o długości 1.5m i 2.0m oraz wyboczeniu globalnym słupów o długości 3.0m. Dokonano analizy odkształceń stali i betonu, stwierdzając ich współpracę w przenoszeniu obciążenia, analogicznie do słupów zespolonych. Pomierzone wartości odkształceń stali wykazały osiągnięcie granicy plastyczności. Natomiast odkształcenia betonu między przewiązkami przekroczyły wartości odkształceń granicznych odpowiadające maksymalnym naprężeniom. Zatem można wyciągnąć wniosek, że wytrzymałość betonu wzrosła z powodu ograniczenia odkształceń przez profile stalowe. Wydaje się, że w przypadku obliczeń nośności plastycznej przekrojów zbliżonych do badanych, zgodnie z Eurokodem 4, współczynnik redukcyjny wytrzymałości betonu można zwiększyć powyżej wartości 0.85. Wypełnienie betonem spowodowało wzrost nośności słupa stalowego o długości 2.0m o ok. 111%. Stwierdzono także, że w badanych słupach dwugałęziowych wypełnionych betonem, wpływ smukłości ma znacząco mniejszy wpływ na zmniejszenie nośności niż w słupach stalowych - dla elementów o długości 2.0m o około 43%. Uzyskane rezultaty badań potwierdzają praktyczny aspekt stosowania tego typu przekrojów w słupach o dużej nośności oraz przemawiają za prowadzeniem badań w kierunku ustalenia czy można traktować je, a w rezultacie obliczać, jako zespolone.
Źródło:
Archives of Civil Engineering; 2019, 65, 4; 3-19
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane zagadnienia modelowania słupów stalowych poddanych oddziaływaniom pożarowym
Selected Issues Concerning the Use of Computational Techniques in the Design of Steel Pillars Subsequently Exposed to a Fire
Autorzy:
Król, P. A.
Kwaśniewski, L.
Łącki, K. J.
Powiązania:
https://bibliotekanauki.pl/articles/372862.pdf
Data publikacji:
2014
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
pożar
słup stalowy
model numeryczny
weryfikacja
walidacja
kalibracja
sprzężone analizy termo-mechaniczne
fire
steel column
numerical model
verification
validation
calibration
coupled structural-thermal analysis
Opis:
Cel: Celem artykułu jest wskazanie możliwości wykorzystania dostępnych, zaawansowanych narzędzi numerycznych do wirtualnego testowania konstrukcji poddanych oddziaływaniom symulowanego pożaru. Przy poprawnie skalibrowanym modelu obliczeniowym, testy przeniesione na platformę wirtualną mogą stanowić wiarygodną alternatywę dla tradycyjnych, kosztownych metod badawczych, w szczególności badań doświadczalnych konstrukcji w skali naturalnej. Wprowadzenie: Modelowanie słupów stalowych w warunkach pożaru napotyka poważne trudności z uwagi na problemy z dopasowaniem i właściwą kalibracją modelu numerycznego w sposób zapewniający jak najlepsze odwzorowanie warunków pracy, zbliżonych do tych, w jakich znajduje się rzeczywista konstrukcja. W trakcie pożaru, w elementach nośnych (słupach, ryglach) rzeczywistej konstrukcji, przesztywnionej w sposób naturalny elementami doń dochodzącymi generują się dodatkowe siły wewnętrzne, trudne do przewidzenia i których wielkość zależy od sztywności elementów zbiegających się w węzłach, sposobu ich deformacji, rozkładu pól temperatury itp. Ograniczenie zarówno przemieszczeniowych, jak i obrotowych stopni swobody wywołuje dodatkowe obciążenie, które w połączeniu ze zmniejszoną (na skutek działania podwyższonej temperatury) sztywnością elementu może powodować jego wcześniejsze wyboczenie i tym samym – zmniejszenie jego odporności pożarowej, często poniżej poziomu wymaganego odpowiednimi przepisami techniczno-budowlanymi. Metodyka: W niniejszym opracowaniu zaprezentowano wyniki analiz i symulacji numerycznych przeprowadzonych z uwzględnieniem nieliniowego charakteru zjawisk. W pracy położono nacisk na doskonalenie przyjętego modelu obliczeniowego, jego weryfikację i wielokryterialną walidację. W analizach uwzględniono kilka wariantów warunków brzegowych – zarówno termicznych, jak i mechanicznych. Wyniki analiz porównano z wynikami autentycznych badań laboratoryjnych przeprowadzonych w Uniwersytecie Ulster we współpracy z Uniwersytetem w Sheffield (Wielka Brytania), które wykorzystano do walidacji modelu numerycznego. Wnioski: Ciągły rozwój technik obliczeniowych stwarza możliwości wykorzystania w analizie konstrukcji budowlanych nowoczesnych metod i narzędzi komputerowych, pozwalających na prowadzenie zaawansowanych analiz termo-mechanicznych. Dostępne narzędzia numeryczne umożliwiają dokładną ocenę przyrostu temperatury elementów konstrukcyjnych z równoczesną analizą wpływu warunków środowiska na mechaniczną odpowiedź konstrukcji. Na obecnym etapie stosowanie tego typu technik obliczeniowych wymaga, poza umiejętnościami obsługi skomplikowanych, komercyjnych narzędzi komputerowych, także zaawansowanej, gruntownej wiedzy teoretycznej. Przeprowadzone analizy wykazały, jak pozornie nieistotne i trudne do uchwycenia błędy modelowe mogą wpływać na jakość uzyskanych wyników.
Aim: The purpose of this study is identification of accessible advanced computational tools to facilitate virtual testing of structures exposed to the thermal action of fire. With correctly calibrated numeric models, structure tests transferred to a virtual platform can provide a credible alternative to traditional costly research methods, particularly experimental research performed on actual scale constructions. Introduction: The modelling process for steel pillars exposed to action of a fire faces serious difficulties because of problems involving matching and proper calibration of the numeric model to ensure the best possible reproduction of working conditions, similar to those in the actual environment. During a fire incident, additional internal forces are generated, which are difficult to predict, culminating in deformation of pillars and adjoining structure elements. Axial and rotational restraints can produce significant loadings which, together with reduced rigidity caused by thermal action, may cause premature buckling of pillars, often below accepted parameters required by relevant building regulations, and reduce pillars’ resistance to the consequence of fire. Methodology: The paper reveals results from an analysis and performed numeric simulations, and takes account of the non-linear character of outcomes. The paper provides a focus on the development of a selected numeric model, its verification and validation. The analysis includes several variations of boundary conditions covering thermal as well as mechanical issues. For validation purposes, the numeric prediction of structural reaction during heating was compared with published experimental data for tests performed at the University of Ulster in collaboration with the University of Sheffield, UK. Conclusions: The continuous development of computational techniques provides opportunities in the application of modern techniques and computer technology for performing advanced structural-thermal analysis for building structures. Available numeric tools allow for an accurate assessment of temperature increases in structures. Simultaneously, they facilitate an examination of influences caused by environmental conditions on the mechanical reaction of structures. In order to use such a computational technique a prerequisite lies in the ability to manipulate complex commercial software. Additionally, it is necessary to have advanced and in depth theoretical knowledge of the topic. Examination by authors reveal how seemingly insignificant and difficult to identify modelling errors can affect the quality of final results.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2014, 4; 65-76
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Seismic evaluation of mixed steel and RC columns in hybrid high-rise buildings
Autorzy:
Kontoni, D. P. N.
Farghaly, A. A.
Powiązania:
https://bibliotekanauki.pl/articles/230311.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
budynek wysoki
konstrukcja hybrydowa
budynek żelbetowo-stalowy
belka żelbetowa
płyta żelbetowa
kolumna żelbetowa
kolumna stalowa
odpowiedź sejsmiczna
konstrukcja odporna na trzęsienia ziemi
odporność na wstrząsy sejsmiczne
high-rise building
hybrid structure
reinforced concrete steel building
reinforced concrete beam
reinforced concrete slab
reinforced concrete column
steel column
seismic response
earthquake-resistant structure
Opis:
The growth in high-rise building construction has increased the need for hybrid reinforced concrete and steel structural systems. Columns in buildings are the most important elements because of their seismic resistance. Reinforced concrete (RC) columns and steel columns were used herein to form hybrid structural systems combining their distinct advantages. Eleven 3D building models subjected to earthquake excitation with reinforced concrete beams and slabs of 12 floors in height and with different distributions of mixed columns were analyzed by the SAP2000 software in order to investigate the most suitable distributions of a combination of reinforced concrete and steel columns. Top displacements and accelerations, base normal forces, base shear forces, and base bending moments were computed to evaluate the selected hybrid structural systems. The findings are helpful in evaluating the efficiency of the examined hybrid high-rise buildings in resisting earthquakes.
Źródło:
Archives of Civil Engineering; 2019, 65, 2; 3-17
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odporność ogniowa konstrukcji słupowych zabezpieczonych okładzinami z gipsu syntetycznego
Fire resistance of pole structures protected with synthetic plastering
Autorzy:
Kania, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2055957.pdf
Data publikacji:
2021
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
konstrukcja prętowa
słup stalowy
zabezpieczenie ogniochronne
okładzina gipsowa
gips syntetyczny
odporność ogniowa
ściana gipsowa
izolacyjność ogniowa
pomiar temperatury
klasyfikacja ogniowa
bar structure
steel column
fire barrier
gypsum panel cladding
synthetic gypsum
fire resistance
gypsum wall board
fire insulation
temperature measurement
fire classification
Opis:
Konstrukcje prętowe, do jakich zaliczamy słupy, nie pełnią zwykle funkcji oddzielającej, w związku z czym powinny spełniać jedynie kryterium nośności ogniowej (R). Jednak w sytuacji, gdy słup tworzy ciągłą przegrodę z przylegającą do niego ścianą, wymagane są w stosunku do niego także dwa pozostałe kryteria: szczelności (E) oraz izolacyjności ogniowej (I). w artykule przedstawiono rozwiązanie zabezpieczeń przeciwpożarowych stalowych słupów konstrukcyjnych z wykorzystaniem okładzin z gipsu syntetycznego, materiału odpadowego uzyskanego w procesie odsiarczania spalin z paliw kopalnych metodą mokrą wapienną.
Bar structures, which include columns, usually do not have a separating function, and therefore should only meet the fire resistance (R) criterion. However, when a column forms a continuous partition with an adjacent wall, two other criteria are also required: tightness (E) and fire insulation (I). The article presents a fire protection solution for structural steel columns with the use of synthetic gypsum cladding, a waste material obtained in the process of desulphurization of fossil fuels using the wet lime method.
Źródło:
Przegląd Budowlany; 2021, 92, 11-12; 119--121
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odporność ogniowa konstrukcji słupowych zabezpieczonych okładzinami z gipsu syntetycznego
Fire resistance of pole structures protected with synthetic plastering
Autorzy:
Kania, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2055983.pdf
Data publikacji:
2021
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
konstrukcja prętowa
słup stalowy
zabezpieczenie ogniochronne
okładzina gipsowa
gips syntetyczny
odporność ogniowa
ściana gipsowa
izolacyjność ogniowa
pomiar temperatury
klasyfikacja ogniowa
bar structure
steel column
fire barrier
gypsum panel cladding
synthetic gypsum
fire resistance
gypsum wall board
fire insulation
temperature measurement
fire classification
Opis:
Konstrukcje prętowe, do jakich zaliczamy słupy, nie pełnią zwykle funkcji oddzielającej, w związku z czym powinny spełniać jedynie kryterium nośności ogniowej (R). Jednak w sytuacji, gdy słup tworzy ciągłą przegrodę z przylegającą do niego ścianą, wymagane są w stosunku do niego także dwa pozostałe kryteria: szczelności (E) oraz izolacyjności ogniowej (I). W artykule przedstawiono rozwiązanie zabezpieczeń przeciwpożarowych stalowych słupów konstrukcyjnych z wykorzystaniem okładzin z gipsu syntetycznego, materiału odpadowego uzyskanego w procesie odsiarczania spalin z paliw kopalnych metodą mokrą wapienną.
Bar structures, which include columns, usually do not have a separating function, and therefore should only meet the fire resistance (R) criterion. However, when a column forms a continuous partition with an adjacent wall, two other criteria are also required: tightness (E) and fire insulation (I). The article presents a fire protection solution for structural steel columns with the use of synthetic gypsum cladding, a waste material obtained in the process of desulphurization of fossil fuels using the wet lime method.
Źródło:
Przegląd Budowlany; 2021, 92, 11-12; 119--121
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies