Tytuł:
Wpływ stałej czasowej obwodu wzbudzenia na przebieg procesu synchronizacji silnika synchronicznego
Influence of time constant excitation circuit on synchronization process in synchronous motors
Autorzy:
Zalas, P.
Zawilak, J.
Powiązania:
https://bibliotekanauki.pl/articles/2077264.pdf
Data publikacji:
2007
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silnik synchroniczny
synchronizacja
stała czasowa
Opis:
The work presents calculation results of synchronization process of a one-speed, silent-pole, high power synchronous motor. The calculations were based on the examined circuit model for the high power motor type GAe 1716t. The motor works in fans drives in underground mines. The influence of time constant excitation circuit on stator currents, angle δ, excitation current and voltage, electromagnetic torque and shaft velocity during synchronization process has been investigated. The influence of change value time constant excitation circuit on choice the synchronization moment was examined. Dynamic diagrams of stator currents, excitation current, excitation voltage, angle δ, electromagnetic torque and shaft velocity during synchronization process as results of computer simulation are presented.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2007, 77; 233-236
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metodyczne aspekty wyznaczania czasów trwania, wielkości zakłócenia i ich wpływu na jakość doju w dojarce rurociągowej
Methodic aspects of determining durations, disturbance size, and their impact on milking quality in pipeline milking machine
Autorzy:
Skalska, D.
Nejman, M.
Powiązania:
https://bibliotekanauki.pl/articles/290056.pdf
Data publikacji:
2010
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
dojarka ruruciągowa
zakłócenie
stała czasowa
uchyb
pipeline milking machine
disturbance
time constant
Opis:
Określono zakłócenia w rurociągu mlecznym przez pomiar podciśnienia: za aparatem udojowym, różnicy ciśnień między rurociągiem podciśnienia i mlecznym, w kolektorze, w komorze podstrzykowej. Następnie dla wyżej wymienionych punktów pomiarowych przedstawiono sposoby wyznaczania: maksymalnego spadku podciśnienia, powierzchnię pod zarejestrowanym spadkiem podciśnienia i całkowitą powierzchnię w przypadku wystąpienia przeregulowania (względem podciśnienia ustalonego) przez regulator - tzw. uchyb przejściowy oraz czas trwania zakłócenia.
The research allowed to determine disturbances in milk pipeline by vacuum (negative pressure) measurement: after milking apparatus, differential pressure between vacuum and milk pipeline, in collector, in chamber under teats. Then, for the above-mentioned measurement points, the work presents methods allowing to determine the following: maximum negative pressure drop, area under recorded negative pressure drop, and total area in case of readjustment (with regard to preset negative pressure value) by control unit - the so-called temporary deviation and disturbance duration.
Źródło:
Inżynieria Rolnicza; 2010, R. 14, nr 2, 2; 163-171
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie właściwości dynamicznych płaskiego kolektora słonecznego
Determination of dynamic properties of a flat plate solar collector
Autorzy:
Obstawski, P.
Powiązania:
https://bibliotekanauki.pl/articles/154496.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
płaski kolektor słoneczny
charakterystyka skokowa
stała czasowa
flat solar collector
step characteristic
time constants
Opis:
W artykule przedstawiono metodykę wyznaczania właściwości dynamicznych płaskiego kolektora słonecznego wg Normy PN-EN 12975-2, którą porównano z metodyką wg automatyki. Zaprezentowano występujące rozbieżności. Zwrócono uwagę na fakt dokonywanych aproksymacji w określaniu właściwości dynamicznych kolektora podczas badań normatywnych.
In order to correctly design a solar installation or a power supply hybrid system based on a solar segment built of flat fluid collectors, it is necessary to know the characteristic of the applied collector efficiency and to determine its dynamic properties.. Exploitation parameters of a flat solar collector and its dynamic proprieties are determined on a basis of normative investigations according to PN - EN 12975-2 [6]. According to that norm, the collector dynamic properties are determined only on the ground of the equivalent time constant obtained from the experimental step characteristic (Fig. 1) and dependence (1). Such a procedure results in obtaining approximation of the collector dynamic properties because of neglecting the time delay and the amplification factor. Figs. 3 and 4 show the experimental step characteristics of the solar collector, basing on which there were determined the collector dynamic properties according to the standard and the classic theory of automatic control. The obtained time constants are similar, whereas the time delay neglected by the standard in the first case (the flow equal to 1.2 dm3/min) (Fig. 3) is equal to 25% of the time constant, which is a large approximation of the collector dynamic properties. The delay time is connected with the flow speed of a medium through the collector and it can be determined form relationship (6) with a good accuracy. Dynamic properties of an existing solar installation can be determined based on the exploitation data with use of the parametric identification method [5].
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 10, 10; 833-836
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reduction of dynamic error in measurements of transient fluid temperature
Autorzy:
Jaremkiewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/240052.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
analiza niepewności
model pierwszego obiektu
pomiar temperatury
stała czasowa
warunki przejściowe
first-order model
temperature measurement
time constant
transient conditions
uncertainty analysis
Opis:
Under steady-state conditions when fluid temperature is constant, temperature measurement can be accomplished with high degree of accuracy owing to the absence of damping and time lag. However, when fluid temperature varies rapidly, for example, during start-up, appreciable differences occur between the actual and measured fluid temperature. These differences occur because it takes time for heat to transfer through the heavy thermometer pocket to the thermocouple. In this paper, a method for determinig transient fluid temperature based on the first-order thermometer model is presented. Fluid temperature is determined using a thermometer, which is suddenly immersed into boiling water. Next, the time constant is defined as a function of fluid velocity for four sheated thermocouples with different diameters. To demonstrate the applicability of the presented method to actual data where air velocity varies, the temperature of air is estimated based on measurements carried out by three thermocouples with different outer diameters. Lastly, the time constant is presented as a function of fluid velocity and outer diameter of thermocouple.
Źródło:
Archives of Thermodynamics; 2011, 32, 4; 55-66
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda wyznaczania stałej czasowej termopary na podstawie pomiaru szybkozmiennej temperatury spalin wylotowych silnika o ZS
Method of Determining the Time Constant of Thermocouple Based on Measurement of the Quick – Changing Temperatures of Exhaust Gases in Marine Diesel Engines
Autorzy:
Puzdrowska, P.
Powiązania:
https://bibliotekanauki.pl/articles/341533.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Morski w Gdyni. Wydawnictwo Uniwersytetu Morskiego w Gdyni
Tematy:
silnik o ZS
termopara typu K
temperatura spalin
stała czasowa
marine diesel engine
thermocouple type K
temperature of exhaust gas
time constant
Opis:
W niniejszym artykule przedstawiono problematykę wyznaczania stałej czasowej termopary. Wskazano na wagę właściwości dynamicznych termopar podczas eksperymentów. Przedstawiono stanowisko laboratoryjne, na którym przeprowadzono badania, mające na celu wyznaczenie stałych czasowych dwóch rodzajów termopar. Zaprezentowano trzy metody obliczania tego parametru. Określono wartość stałej czasowej, wyznaczonej metodą symulacji numerycznej wymiany ciepła między spoiną termopary a spalinami ją otaczającymi, przy założeniu wolnozmienności procesu, czyli przejścia z jednego stanu ustalonego do drugiego. W kolejnym kroku obliczono ten parametr również dla takiego przejścia, jednak dokonano tego na podstawie rzeczywistej szybkozmiennej temperatury spalin, zarejestrowanej podczas badania na stanowisku laboratoryjnym. Jako trzecią metodę przedstawiono określanie wartości stałej czasowej dla warunków chwilowych, dla szybkozmiennej temperatury rejestrowanej podczas eksperymentu, dla przebiegu pseudookresowego w obrębie trwania jednego cyklu roboczego silnika. Dokonano porównania i oceny uzyskanych wyników obliczeń, a co za tym idzie, użyteczności metody wyznaczania stałej czasowej termopar.
The article presents issue of determining the time constant of thermocouple. The importance of dynamic properties of thermocouples during experiments was indicated. This paper presents the laboratory stand where experiments were made to determine the time constants of two types of thermocouples. Three methods of calculating this parameter were presented. The value of the time constant was determined by the numerical simulation of heat transfer between thermocouple’s weld and the surrounding exhaust gases, assuming the slow – changing of the process, namely transition from the steady state to the other. In the next step this parameter was calculated for the same transition but it was based on real and quick – changing temperature of exhaust gases, recorded during the experiment on laboratory stand. As the third method there was shown determining the value of time constant for the temporary conditions, for quick – changing temperature, recorded during the experiment, for the pseudo-periodic process within the duration of the cycle of engine. At the end, a comparison and evaluation of the calculation results was made, and the usefulness of the method of determining the time constant of thermocouples.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Gdyni; 2018, 108; 115-133
1644-1818
2451-2486
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Gdyni
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamiczna metoda pomiaru zawartości materiału fazowo-zmiennego w izolacji włóknistej
Dynamic test method of PCM content in fiberous insulation
Autorzy:
Kossecka, E.
Kośny, J.
Powiązania:
https://bibliotekanauki.pl/articles/362722.pdf
Data publikacji:
2009
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
materiał fazowo-zmienny
izolacja celulozowa z PCM
aparat płytowy
pomiary testowe
stała czasowa
phase change material
cellulose insulation with PCM
camera plate
testing measurements
time constant
Opis:
Przedstawiono koncepcję metodyki prowadzenia testowych pomiarów zawartości materiału fazowo-zmiennego, w dużych i w założeniu jednorodnych próbkach izolacji z włókna szklanego lub celulozy, z użyciem aparatu płytowego. Podano sposób szacowania stałej czasowej próbki w procesie ustalania się strumienia ciepła po skoku temperatury.
Dynamic test method of PCM content in fiberous insulation is considered. Heat balance of a sample of material with PCM is analyzed. Time constants for 7.6 cm thick samples of PCM-Enhanced Cellulose Insulation are estimated.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2009, T. 4; 109-112
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies