Measurement systems in Smart Grid
Autorzy:
Paluszczak, M.
Twardosz, W.
Twardosz, G.
Powiązania:
https://bibliotekanauki.pl/articles/97527.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
smart grid
automatic electricity meter reading
transmission media
renewable energy sources
Opis:
The paper presents to-day’s state of development of intelligent measurement systems used for monitoring and analysis of operation of renewable energy sources. Advantages and faults of various systems of remote electric power read-out.
Źródło:
Computer Applications in Electrical Engineering; 2013, 11; 408-415
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synchrophasors-based transmission line protection in the presence of STATCOM
Autorzy:
Ghorbani, Amir
Powiązania:
https://bibliotekanauki.pl/articles/41184010.pdf
Data publikacji:
2023
Wydawca:
Politechnika Warszawska, Instytut Techniki Cieplnej
Tematy:
flexible AC transmission system (FACTS)
controllers
ground distance relay
phasor measurement unit
static synchronous compensator
smart grid
elastyczny system transmisji prądu przemiennego
kontrolery
przekaźnik odległości naziemnej
jednostka miary fazora
statyczny kompensator synchroniczny
inteligentna sieć
Opis:
The distance relay using the transmission line impedance measurement identifies the type and location of the fault. However, any other factors that cause the failure of the measured impedance, makes the relay detect the fault in incorrect location or do not detect the fault at all. One of these factors is the fault resistance which directly increases the measured impedance by the relay. Another factor that indirectly alters the impedance of the transmission line is static synchronous compensator (STATCOM). When a fault happens, current injection by the STATCOM changes the measured signals by the relay and thus makes the calculated impedance incorrect. In this paper, a method is provided based on the combination of distance and differential protection. Firstly, from the current data of buses, faulted transmission line is detected. Then using the presented algorithm, the fault location is calculated on the transmission line. The basis of the algorithm is on the active power calculation of the buses. Fault resistance is calculated from the active powers and its effect will be deducted from calculated impedance by the algorithm. Furthermore, with choosing data of appropriate bus, STATCOM effect is eliminated, and fault location will be obtained.
Źródło:
Journal of Power Technologies; 2023, 103, 1; 58-71
1425-1353
Pojawia się w:
Journal of Power Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies