Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Sewage" wg kryterium: Temat


Tytuł:
Analysis of sewage susceptibility to biodegradation on an example of sewage treatment plant in Wodzisław Śląski
Autorzy:
Chmielowski, K.
Wąsik, E.
Operacz, A.
Bugajski, P.
Kaczor, G.
Jurik, L.
Powiązania:
https://bibliotekanauki.pl/articles/101267.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
sewage biodegradation
sewage composition
sewage treatment plant
Opis:
The paper presents an analysis of sewage susceptibility to biodegradation on an example of sewage treatment plant in Wodzisław Śląski in the Śląskie province. For this purpose, dependencies between selected indices of domestic sewage pollution were applied. Descriptive statistics of the respective indices rations COD/BOD5 , BOD5 /TN, BOD5 /TPwere presented. Moreover, an analysis was conducted on the composition of raw sewage flowing into the treatment plant, pre-treated sewage and sewage leaving the studied treatment plant. The analysis was carried out on the basis of three basic indices of sewage pollution (BOD5 , COD and total suspended solids) and two biogenic indices (total nitrogen and total phosphorus). Tests on the sewage composition were conducted in the years 2010-2015. Basic descriptive statistics were compiled for the values of the studied indices of sewage pollution and the obtained results were interpreted. On the basis of collected material it may be said that sewage reaching the treatment plant in Wodzisław Śląski revealed a good susceptibility to biodegradation, whereas the BOD5 /TN and BOD5 /TP ratios were below the optimum value.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2017, IV/1; 1427-1443
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The efficiency of pollutant elimination in the Dobra treatment plant
Autorzy:
Nowak, J.
Chmielowski, K.
Chmielowska, B.
Bedla, D.
Powiązania:
https://bibliotekanauki.pl/articles/101622.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
sewage treatment plant
domestic sewage
SBR
Opis:
This study was aimed to conduct an analysis of the efficiency of pollutant elimination in the Dobra treatment plant, which operates based on the SBR reactor. The object purifies domestic sewage and pre-treated industrial sewage from a slaughterhouse within the Dobra municipality. The source material for the analysis comprised the values of pollution indicators: BOD5 , CODCr, total suspended solids (TTS) in raw sewage (19 samples) and treated sewage (34 samples). The results of chemical analyses were obtained in the period 2007-2014. The results were compared with the limit values imposed by the Regulation (2014). The coefficient of reliability of the treatment plant was also calculated in this study. The average efficiency of pollutant elimination in the treatment plant was: BOD5 - 98.6%, CODCr - 94.9%, total suspended solids - 97.6%. These results demonstrate that the studied facility operates flawlessly and the treatment efficiency is high. On the other hand, the reliability coefficient values indicate that the operation of this object is unstable.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, III/1; 737-747
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza procesu technologicznego w zakładzie oczyszczania ścieków i przygotowania osadów
Analysis of the technological process in the sewage treatment plant
Autorzy:
Richter, D.
Fokczyńska, E.
Ogłaza, P.
Kijo-Kleczkowska, A.
Środa, K.
Powiązania:
https://bibliotekanauki.pl/articles/357309.pdf
Data publikacji:
2016
Wydawca:
Politechnika Śląska
Tematy:
sewage treatment plant
sewage
sewage sludge
oczyszczalnia ścieków
ściek
osad ściekowy
Opis:
The paper presents an analysis of the technological process of wastewater treatment and the process of preparation of sludge in a wastewater treatment plan t in Koszęcin. Firstly we presented the location of the plant, described its characteristics and discussed the environmental conditions of the functioning of the plant. Then we investigated parameters of the process and technology in the considered plant, the stages of wastewater tratment and dewatering of excess sludge. Also we presented laboratory tests of wastewater and sludge.
W pracy zaprezentowano analizę procesu technologicznego oczyszczania ścieków oraz przygotowania osadów w oczyszczalni ścieków w Koszęcinie. Na wstępie zaprezentowano lokalizację zakładu, dokonano jego charakterystyki oraz omówiono warunki środowiskowe funkcjonowania wspomnianej oczyszczalni. Rozpatrzono parametry procesowo-technologiczne w rozpatrywanym zakładzie etapy oczyszczania ścieków i odwadnianie osadu nadmiernego. Przedstawiono również badania laboratoryjne ścieków i osadów.
Źródło:
Archiwum Gospodarki Odpadami i Ochrony Środowiska; 2016, 18, 3; 35-50
1733-4381
Pojawia się w:
Archiwum Gospodarki Odpadami i Ochrony Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Changes in surface water microflora caused by discharge of purified sewage into rivers
Autorzy:
Godela, Agnieszka
Lewańska, Monika
Myga-Nowak, Magdalena
Powiązania:
https://bibliotekanauki.pl/articles/1179554.pdf
Data publikacji:
2017
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Sewage
river
sewage treatment plant
sewers
water microflora
Opis:
Progressive environmental degradation results in an increase in the number of waters that do not meet the standards in force. Surface waters are particularly vulnerable to pollution because they are receivers of purified water and agricultural or industrial wastewater flow. In addition, the local increase in temperature and the increase amount and availability of nutrients associated with wastewater discharged improves the microbial growth and thus increase their quantity. The treated sewage must meet certain requirements regarding their physicochemical and biological parameters. However, the regulations do not require to check microbiological quality by treatment plants, so the purpose of the study was to determine the impact of discharge of purified wastewater by the "Warta" sewage treatment plant down to Warta river. The study was conducted in 2008-2016 at three collection points near the place of discharge of purified sewage from Warta SA sewage treatment plant. It has been demonstrated that the process of sewage treatment is not enough in terms of microbiological pollution because the water samples collected at the points behind the discharge site of the effluent into the river were characterized by increased abundance and microbiological diversity.
Źródło:
World Scientific News; 2017, 75; 26-32
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sewage sludge management in a sewage treatment plant
Autorzy:
Królik, Dariusz
Wypych, Przemysław
Kostecki, Jakub
Powiązania:
https://bibliotekanauki.pl/articles/396339.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
sewage sludge
biogas
sewage treatment plant
osady ściekowe
biogaz
oczyszczalnia ścieków
Opis:
Sewage sludge produced in municipal sewage treatment plants, because of its physicochemical and sanitary properties, is a serious threat to the environment. In order to neutralize it, various methods of processing are used, which directly affect the quantity and quality of produced sewage sludge, which in the final stage can be used naturally. Properly managed sludge management is presented on the example of a sewage treatment plant, conducting the methane fermentation process with the production of biogas.
Źródło:
Civil and Environmental Engineering Reports; 2019, 29, 3; 209-217
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena pracy oczyszczalni ścieków w Starachowicach
Validation of the operations of wastewater treatment plant in Starachowice
Autorzy:
Budkowska, A.
Długosz, J.
Gawdzik, J.
Powiązania:
https://bibliotekanauki.pl/articles/357090.pdf
Data publikacji:
2012
Wydawca:
Politechnika Śląska
Tematy:
ścieki
oczyszczalnia ścieków
wskaźniki zanieczyszczeń
sewage
sewage treatment plant
pollutants indexes
Opis:
W pracy przedstawiono ocenę funkcjonowania jednej  z największych oczyszczalni ścieków w województwie świętokrzyskim - oczyszczalni ścieków komunalnych w Starachowicach. Ocenę sprawności działania oczyszczalni oparto na wielkości redukcji 5 wybranych wskaźników zanieczyszczeń: BZT5, ChZT, zawiesina ogólna, azot ogólny i fosfor ogólny. Redukcja wszystkich analizowanych wskaźników z wyjątkiem azotu ogólnego była na poziomie wyższym od wytycznych podanych w Rozporządzeniu z dnia 31 lipca 2006 roku. Przedstawiono charakterystykę procesów jednostkowych oraz dokonano oceny efektywności systemu oczyszczania ścieków na oczyszczalni. Analizując wartości średniodobowego niskiego przepływu rzeki oraz średniej dobowej ilości ścieków odprowadzanej do odbiornika  można stwierdzić, iż rzeka Kamienna jest odpowiednim odbiornikiem dla oczyszczonych ścieków.
The paper presents an evaluation of functioning of one sewage treatment plant in Swietokrzyskie Province – wastewater treatment plant near Starachowice. Evaluation of operation capacity was based on reduction size of 5 chosen pollutants' indexes: BOD5, COD, total suspended solids, total nitrogen and total phosphorus. Reduction of all analysed indexes except total nitrogen and total phosphorus was on the level higher than guidelines given by the Ordinance from 31st July 2006. The characteristics of unit processes and assessment of the effectiveness of the sewage treatment systems was done in this work. Analyzing of the average daily volume of wastewater discharged into the receiver can be concluded, that Kamienna river is a suitable receiver for the treated wastewater.
Źródło:
Archiwum Gospodarki Odpadami i Ochrony Środowiska; 2012, 14, 3; 1-11
1733-4381
Pojawia się w:
Archiwum Gospodarki Odpadami i Ochrony Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ ścieków oczyszczonych na oczyszczalni w Myślenicach na jakość wód ich odbiornika
Impact of treated sewage on sewagetreatment plant in Myślenice on the quailty of their receiver
Autorzy:
Miernik, W.
Młyński, D.
Wałęga, A.
Chmielowski, K.
Karwacki, A.
Powiązania:
https://bibliotekanauki.pl/articles/101265.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
ścieki
oczyszczalnia
odbiornik
rzeka Raba
sewage
sewage treatment plant
receiver
Raba river
Opis:
Artykuł zawiera analizę i ocenę wpływu ścieków oczyszczonych w oczyszczalni w Myślenicach w latach 2008 - 2011, na skład fizyczno-chemiczny oraz jakość wód ich odbiornika - rzeki Raby. Pracę wykonano na podstawie zebranych oraz statystycznie opracowanych wyników badań, obejmujących ilość i skład ścieków oczyszczonych, odprowadzanych do Raby, a także skład wód odbiornika w przekrojach Stróże i Osieczany, znajdujących się odpowiednio powyżej i poniżej punktu zrzutu ścieków oczyszczonych. Zakres wskaźników zanieczyszczeń oznaczanych w ściekach i wodzie obejmował: zawiesinę ogólną, BZT5 , ChZTCr, fosfor ogólny oraz azot ogólny. Na podstawie wykonanych badań stwierdzono, że oczyszczalnia ścieków w Myślenicach, w latach 2008 - 2011, funkcjonowała prawidłowo, ponieważ oczyszczone na niej ścieki, spełniały wymogi pozwolenia wodno-prawnego, co przekładało się bezpośrednio na skuteczną ochronę przed zanieczyszczeniem wód ich odbiornika. Ponadto stwierdzono, że w obu badanych przekrojach skład fizyczno-chemiczny wód Raby był do siebie zbliżony. Potwierdziły to wyniki zastosowanego testu U Mann'a-Whitney'a, które nie wykazały statystycznie istotnych różnic pomiędzy średnimi wartościami stężeń analizowanych wskaźników zanieczyszczeń. Ścieki oczyszczone, odprowadzane z oczyszczalni w Myślenicach do rzeki Raby nie przyczyniają się do pogorszenia jakości jej wód.
The article contains analysis and evaluation of the impact of clean sewage on sewage treatment plant in Myślenice, in the period 2008 - 201,1 on the physico-chemical composition and water quality of the receiver - river Raba. The analysis conducted based on collected and statistical research: amount and composition of clean sewage and composition of the water receiver in cross-section: Stróże (above of inflow clean sewage) and Osieczany (below of inflow clean sewage). The following pollution index were tested: total suspended solids, BOD5, CODCr, total nitrogen and total phosphorus. Based on obtained results its concluded that in period 2008 - 2011 sewage treatment plant was working properly, what explain quality of clean sewage. What reflected in directly protection of receiver water against pollution. Moreover, based on the results of U Mann Whitney test, concluded that in the both cross-section, composition of the water of Raba river was similar, what explain the results of this test, which didn't show statistically significant differences between average values of concentrations analyzed indicators of pollutions. Based on obtained results its concluded that sewage treatment plant in Myślenice doesn't negatively impact on quality of the water receiver -Raba river.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, I/1; 191-207
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena skuteczności pracy oczyszczalni ścieków w Jaśle
Evaulation of efficency of sewage treatment plant in Jasło
Autorzy:
Młyński, D.
Chmielowski, K.
Młyńska, A.
Miernik, W.
Powiązania:
https://bibliotekanauki.pl/articles/101438.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
ścieki
oczyszczalnia ścieków
niezawodność pracy
sewage
sewage treatment plant
reliability of work
Opis:
Artykuł zawiera ocenę funkcjonowania oczyszczalni ścieków w Jaśle, w wieloleciu 2010 - 2014. Na podstawie wyników badań fizyko-chemicznych ścieków surowych i oczyszczonych wyznaczono wskaźniki niezawodności pracy oczyszczalni takie jak: sprawność oczyszczania, współczynnik niezawodności technologicznej, technologiczną sprawność oczyszczania oraz ryzyko negatywnej oceny działania oczyszczalni, w odniesieniu do następujących wskaźników zanieczyszczeń: zawiesina ogólna, BZT5 , ChZTCr, azot ogólny oraz fosfor ogólny. Na podstawie przeprowadzonych, badań stwierdzono, że średnia redukcja ładunku zanieczyszczeń kształtowała się na poziomie powyżej 90%. Tylko w przypadku azotu ogólnego średnia redukcja była niższa i wynosiła 77%. Bazując na wynikach obliczeń pozostałych wskaźników niezawodności stwierdzono, że badana oczyszczalnia ścieków działała poprawnie i oczyszczała ścieki, których skład spełniał wymogi pozwolenia wodno-prawnego.
The article contains evaluation of functionality of sewage treatment plant in Jasło for multiplicity 2010 - 2014. On the basis of the results raw and cleaned sewage physico-chemical analysis, the efficiency of sewage treatment, coefficient of technological reliability, technological efficiency of sewage treatment and risk of the negative assessment of work of sewage treatment plant, were obtained, for following pollutions indicators: total suspended solids, BOD5 , CODCr, total nitrogen and total phosphorus. Based on obtained results its conclude the average reduction of pollution on level below 90%. Only for total nitrogen the average reduction is lower and is on level 77%. Based on other values of indicators of reliability work of sewage treatment plant its conclude that the tested sewage treatment plant may be certified to operate in high quality and the sewage treated by this plant doesn't threaten the collector of the treated sewage.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, I/1; 147-162
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The State of Water and Wastewater Management in the Municipalities of the Roztocze National Park
Autorzy:
Jóźwiakowski, K.
Podbrożna, D.
Kopczacka, K.
Jaguś, M.
Marzec, M.
Listosz, A.
Pochwatka, P.
Kowalczyk-Juśko, A.
Malik, A.
Powiązania:
https://bibliotekanauki.pl/articles/123660.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
municipality
water supply
sewage system
sewage treatment plant
septic tank
national park
Opis:
The aim of this paper is to present the current state of water and sewage management in the communes where the Roztocze National Park (RNP) is located. The park is located in Lubelskie voivodship, in the territory of four communes: Zamość, Zwierzyniec, Adamów and Józefów, while its buffer zone is located in the communes of Krasnobród, Tereszpol and Szczebrzeszyn. The paper uses data from surveys conducted in these municipalities in 2016. On average, 68.9% of the population used the water supply system in the municipalities surveyed, while 33.4% of the inhabitants had the possibility of discharging sewage to the sewerage system. In the area of the communes, there are 10 collective, mechanical and biological wastewater treatment plants with a capacity exceeding 5 m3·d-1. The households which are not connected to the sewage network discharge wastewater mainly to non-return tanks. Four out of the seven surveyed communities had 64 domestic sewage treatment plants, including 60 systems with infiltration drainage, which do not ensure high efficiency of removing pollution and may even contribute to the degradation of groundwater quality. In order to solve the existing problems in the area of sewage and water management occurring in the communes where the Roztocze National Park is located, it is necessary to further develop collective sewage systems and equip the areas with dispersed buildings with highly efficient, residential sewage treatment plants, e.g. constructed wetlands.
Źródło:
Journal of Ecological Engineering; 2018, 19, 2; 255-262
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena skuteczności pracy oczyszczalni ścieków w Gryfinie
Efficiency of sewage treatment plant in Gryfino
Autorzy:
Szczerbińska, N.
Gałczyńska, M.
Ulas, K.
Burczyk, P.
Mikołajczak, M.
Buśko, M.
Powiązania:
https://bibliotekanauki.pl/articles/339125.pdf
Data publikacji:
2018
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
efektywność oczyszczania ścieków
oczyszczalnia ścieków
ścieki oczyszczone
ścieki surowe
efficiency of wastewater treatment purified sewage
raw sewage
sewage treatment plant
Opis:
Polska – wchodząc w struktury Unii Europejskiej – zobowiązała się do uporządkowania gospodarki ściekowej do końca 2015 r. Dzięki prawidłowej pracy oczyszczalni ścieki odprowadzane do wód odbiornika nie stanowią dla nich zagrożenia. Jest to szczególnie ważne ze względu na potrzebę utrzymania dobrego stanu wód powierzchniowych. Celem badań było określenie efektywności oczyszczania ścieków przez mechaniczno-biologiczną oczyszczalnię ścieków w Gryfinie na podstawie analizy ilości zanieczyszczeń niesionych wraz ze ściekami komunalnymi. Badania przeprowadzono na terenie oczyszczalni ścieków w Gryfinie. Analizy składu ścieków surowych i oczyszczonych obejmowały pięcioletni okres – od 2011 do 2015 r. Analizowano BZT5, ChZT, zawiesinę ogólną, Nog i Pog. Obliczono efektywność pracy oczyszczalni ścieków, skuteczność zmniejszania zanieczyszczeń i wskaźnik technologicznej sprawności oczyszczania. Wyniki badań opracowano statystycznie. Stwierdzono, że średni wskaźnik sprawności oczyszczania ścieków w odniesieniu do zawiesiny ogólnej wyniósł 98,0%, BZT5 – na poziomie 98,9%, natomiast ChZT – na poziomie 97,4%. Średni wskaźnik sprawności oczyszczania ścieków w odniesieniu do azotu ogólnego oraz fosforu ogólnego wyniósł odpowiednio 89,6% i 96,4%. Ustalono, że efektywność oczyszczalnia ścieków w Gryfinie była bardzo duża i zgodna z przepisami.
Poland entering the structures of the European Union committed itself to organize wastewater management by the end of 2015. Due to the correct operation of the sewage treatment plant, the sewage discharged into the receiver water does not pose any danger to them. This is especially important because of the need to maintain good surface water quality. The aim of the study was to analyse the amount of pollutants transported with municipal wastewater, to determine the efficiency of wastewater treatment by mechanical-biological sewage treatment plant in Gryfino. The research was carried out on the sewage treatment plant in Gryfino. Analyses of raw and purified wastewater were carried on a five year period from 2011 to 2015. BOD5, COD, general suspension, total nitrogen and total phosphorus were analyzed. The efficiency of sewage treatment plant operation, efficiency of pollution reduction and the technological wastewater treatment efficiency rate were calculated. The results of the research were statistically analyzed. It was found that the average wastewater treatment efficiency rate for the total suspended solids was 98.0%, and BOD5 – 98.9%, and COD – 97.4%. The average efficiency index of wastewater treatment for total nitrogen and total phosphorus was 89.6% and 96.4% respectively. It was found that the efficiency of the wastewater treatment plant in Gryfino was very good and consistent with the regulations.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2018, 18, 2; 85-98
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka ilościowa i jakościowa osadów ściekowych pochodzących z małych oczyszczalni ścieków w powiecie płockim
The quality and quantity characteristic of sewage sludge coming from small sewage treatment plants on the area of plock county
Autorzy:
Bauman-Kaszubska, H.
Sikorski, M.
Powiązania:
https://bibliotekanauki.pl/articles/401175.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
osady ściekowe
oczyszczalnia ścieków
charakterystyka osadów ściekowych
rolnicze i przyrodnicze wykorzystanie osadów
sewage sludge
sewage treatment plant
characteristic of sewage sludge
agricultural and natural utilization of sewage sludge
Opis:
Stały wzrost ilości osadów powstających w komunalnych oczyszczalniach ścieków oraz niedociągnięcia w zakresie ich zagospodarowania powodują, że problemy gospodarki osadowej wymagają pilnego rozwiązania. Komunalne osady ściekowe, powstające w oczyszczalniach ścieków, nie są nawozami i nie mogą być traktowane jak nawozy naturalne np. obornik. Mogą być stosowane w rolnictwie w formie przetworzonej i nie przetworzonej pod warunkiem, że są ustabilizowane i spełniają wymagania w dopuszczalnych poziomów metali ciężkich oraz wskaźników sanitarnych, a także zawierają określone ilości substancji organicznych oraz związków nawożących azotu, fosforu i potasu. Mogą być wówczas traktowane jako nawozy organiczne zgodnie z ustawą o nawozach i nawożeniu [9]. Zatem bardzo dokładne poznanie charakterystyki osadów jest podstawą wyboru odpowiedniego sposobu ich przeróbki, wykorzystania lub zagospodarowania. Kolejnymi kryteriami wyboru sposobu postępowania z osadami będzie dobór terenu oraz aspekty ekonomiczne. Praca zawiera analizę charakterystyki powiatu płockiego w zakresie gospodarki osadami ściekowymi powstającymi w małych oczyszczalniach ścieków oraz wyniki i analizę badań wykonanych dla osadów pobranych z wybranych obiektów.
Steady increase in sludge quantity emerging from municipal sewage treatment plants and shortcoming in managing sludge cause that problems of sludge management require urgent solution. Municipal sewage sludge, produced in sewage treatment plants, is not fertilizer and can not be treated as natural fertilizer e. g. manure. It can be used in agriculture in processed and not processed form and on condition that it is stabilized and fulfils requirements in permissible levels of heavy metals and sanitary indicators and included definite quantities of organic matter and fertilize compounds of nitrogen, phosphorus and potassium. It can be treated as organic fertilizers in act about fertilizers and manuring [9].That is why precise knowledge of sludge characteristic is the basis of choice as far as proper way of its processing, usage and management is concerned. The next criteria of dealing with sludge will be the choice of area and economic aspects. The thesis includes the analysis of Płock county characteristic as far as sewage sludge treatment emerging from small sewage treatments is concerned and the results and analysis of studies made for sludge taken from the chosen objects.
Źródło:
Inżynieria Ekologiczna; 2011, 25; 20-19
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena poprawności funkcjonowania miejskiej oczyszczalni ścieków w Piasecznie
Validation of the operations of municipal wastewater treatment plant in Piaseczno
Autorzy:
Długosz, J.
Gawdzik, J.
Powiązania:
https://bibliotekanauki.pl/articles/357202.pdf
Data publikacji:
2012
Wydawca:
Politechnika Śląska
Tematy:
ścieki
oczyszczalnia ścieków
wskaźniki zanieczyszczeń
sewage
sewage treatment plant
pollutants’ indexes
Opis:
W pracy przedstawiono ocenę funkcjonowania oczyszczalni ścieków komunalnych w Piasecznie. Ocenę sprawności działania oczyszczalni oparto na wielkości redukcji 5 wybranych wskaźników zanieczyszczeń: BZT5, ChZT, zawiesina ogólna, azot ogólny i fosfor ogólny. Obiekt uzyskuje bardzo dobre wyniki w oczyszczaniu ścieków, które zgodne są z dopuszczalnymi wartościami zawartymi w Rozporządzeniu Ministra Środowiska z dnia 24 lipca 2006 oraz z pozwoleniem wodnoprawnym. Przedstawiono charakterystykę procesów jednostkowych oraz dokonano oceny efektywności systemu oczyszczania ścieków na oczyszczalni. Analizując wartości średniodobowego niskiego przepływu rzeki oraz średniej dobowej ilości ścieków odprowadzanej do odbiornika można stwierdzić, iż Kanał Piaseczyński jest odpowiednim odbiornikiem dla oczyszczonych ścieków
The paper presents an evaluation of functioning wastewater treatment plant near Piaseczno. Evaluation of operation capacity was based on level of reduction of 5 chosen pollution indexes: BOD5, COD, total suspended solids, total nitrogen and total phosphorus Very good results of wastewater treatment, which complies with the limit values laid down in the Regulation of the Minister of Environment of 24 July 2006 and in the water-legal permission were achieved. The characteristics of unit processes and assessment of the effectiveness of the sewage treatment systems were done in this work. River and the average daily volume of wastewater discharged into the receiver can be concluded, that Kanał Piaseczyński is a suitable receiver for the treated wastewater.
Źródło:
Archiwum Gospodarki Odpadami i Ochrony Środowiska; 2012, 14, 4; 31-40
1733-4381
Pojawia się w:
Archiwum Gospodarki Odpadami i Ochrony Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Influence of Molasses on Nitrogen Removal in Wastewater Treatment With Activated Sludge
Autorzy:
Smyk, J.
Ignatowicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/123119.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
removing nitrogen from sewage
external carbon source
molasses
sewage treatment plant
Opis:
The paper presents the efficiency of nitrogen removal from wastewater using molasses as an external carbon source. The study was conducted during the municipal wastewater treatment process in two independent activated sludge chambers of SBR type. One of the chambers contained molasses as the source of easily available organic compounds. The study showed that the use of molasses as the external carbon source during wastewater treatment resulted in a higher efficiency of nitrogen removal than in the reactor where it no support using external carbon source was applied at the same time resulting low level of the COD value in the treated wastewater.
Źródło:
Journal of Ecological Engineering; 2017, 18, 4; 199-203
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Toxicity of Two Types of Sewage Sludge from Wastewater Treatment Plant for Plants
Autorzy:
Adamcová, D.
Vaverková, M. D.
Břoušková, E.
Powiązania:
https://bibliotekanauki.pl/articles/123316.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
sewage sludge
sewage treatment plant
phytotoxicity
Sinapis alba L
land application
Opis:
The aim of the present study was the estimation of the phytotoxicity of soils amended with sewage sludge with relation to Sinapis alba L. The study was realized in the system of a plot experiment. Two kinds of sewage sludge: dewatered and anaerobically stabilized sludge with dry matter content of about 24%, and dewatered sludge “Palikal” with dry matter content of about 92%. The results indicate that the tested samples are toxic. Growth inhibition at the studied samples ranged from 70.45% to 100%.
Źródło:
Journal of Ecological Engineering; 2016, 17, 2; 33-37
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zmienności dopływu ścieków do oczyszczalni dla aglomeracji Dębica
Analysis of sewage inflow variability to a sewage treatment plant for the agglomeration of Dębica
Autorzy:
Chmielowski, K.
Bugajski, P.
Wąsik, E.
Cupak, A.
Powiązania:
https://bibliotekanauki.pl/articles/101536.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
ścieki bytowe
dopływ ścieków
oczyszczalnia ścieków
domestic sewage
hydraulic load
sewage treatment plant
Opis:
W pracy dokonano analizy zmienności dopływu ścieków do oczyszczalni w Dębicy. W tym celu określono podstawowe statystyki opisowe dotyczące dopływu ścieków do oczyszczalni: wartość średnia (Qdśr), mediana (Mo), wartość minimalna (Qdmin), wartość maksymalna (Qdmax), odchylenie standardowe, współczynnik zmienności (Vzm), rozstęp (Ro). Określono histogram liczby dopływów ścieków do oczyszczalni dla zadanych przedziałów obserwacji. Zestawiono szczegółowe dobowe dopływy ścieków surowych do oczyszczalni w Dębicy w latach 2019-2015 na tle wartości dopuszczalnej z pozwolenia wodno-prawnego oraz wartości średniej. Zestawiono średnie dobowe wartości przepływów ścieków dla poszczególnych miesięcy roku dla okresu 2009-2015. Dokonano zestawienia średnich dobowych przepływów ścieków w poszczególnych latach badanego okresu. Zestawiono średnie dobowe wartości przepływów ścieków w poszczególnych dniach tygodnia dla okresu 2009-2015. Ponadto pozyskano dane opadowe ze stacji w Tarnowie (najbliższa stacja opadowa od badanego obiektu) i na tej podstawie określono średnie wartości dobowego opadu atmosferycznego dla poszczególnych miesięcy w latach 2009-2015. Następnie dokonano podziału dób okresu badawczego ze względu na wielkość opadów atmosferycznych na 7 zasadniczych grup. Określono wpływ opadów atmosferycznych na ilość ścieków dopływających do badanego obiektu. Stwierdzono znaczący wpływ opadów atmosferycznych na dopływ ścieków do oczyszczalni w Dębicy.
The paper analyzes the variability of sewage inflow to a treatment plant in Dębica. For this purpose, the following basic descriptive statistics of the sewage inflow to the treatment plant were determined: mean value (Qdm), median (Mo), minimum value (Qdmin), maximum value (Qdmax), standard deviation, coefficient of variation (Vzm), range (Ro). Histogram of a number of sewage inflows to the treatment plant for the specified observation intervals was determined. Detailed diurnal raw sewage inflows to the treatment plant in Dębica were summarized for the period of 2009-2015 compared to the limit value specified by the water-legal permit and the to the mean value. Mean diurnal sewage flow values for individual months from the period of 2009-2015 were also summarized. Mean diurnal sewage flows in individual years of the studied period, as well as mean diurnal sewage flow values in each day of the week were compared. Moreover, runoff data were obtained from the Tarnów station (the nearest rainfall station to the studied facility) and on this basis mean values of diurnal precipitation for individual months in the period of 2009-2015 were determined. Subsequently, the days of the study period were divided into 7 major groups based on the amount of atmospheric precipitation. The effect of precipitation on the amount of sewage flowing into the studied facility was examined and it was found that the precipitation has a significant effect on the sewage inflow to the treatment plant in Dębica.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, II/2; 589-603
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies