Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "biological sewage treatment" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Chemico-biological sewage treatment plants for PE< 9.999
Chemiczno-biologiczne oczyszczalnie ścieków dla RLM < 9 999
Autorzy:
Heidrich, Z.
Stańko, G.
Powiązania:
https://bibliotekanauki.pl/articles/396506.pdf
Data publikacji:
2007
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
ścieki
oczyszczanie ścieków
oczyszczalnia chemiczno-biologiczna
sewage
chemico-biological sewage treatment plants
nitrogen and phosphorus compounds
Opis:
Removal of nitrogen and phosphorus compounds is not required in the case of sewage treatment plants serving the settlement units of up to 9.999 citizens and not charging treated sewage into staying waters. Therefore, it is possible to reduce the range of water treatment to merely two requirements: the BOD_5 and the concentration of suspended solids. It gives a possibility to use another technological solution in such sewage treatment plants. As a result, due to chemical pre-treatment, size of biological reactors can be substantially reduced. Such approach is justified not only by technical, but predominantly by economical issues.
W oczyszczalniach ścieków obsługujących jednostki osadnicze zasiedlone przez nie więcej niż 10 000 mieszkańców i nie odprowadzających ścieków oczyszczonych do wód stojących, nie jest wymagane usuwanie związków azotu i fosforu. Istnieje zatem możliwość ograniczenia zakresu oczyszczania ścieków do dwóch wymagań: obniżenia BZT_5 i stężenia zawiesin ogólnych. Daje to możliwość zastosowania innego rozwiązania technologicznego w takich oczyszczalniach ścieków. W takim rozwiązaniu w bardzo istotnym stopniu wykorzystuje się wstępne chemiczne oczyszczanie, które ogranicza w znacznym stopniu wielkość reaktorów biologicznych. Takie podejście ma uzasadnienie nie tylko techniczne ale przede wszystkim ekonomiczne.
Źródło:
Civil and Environmental Engineering Reports; 2007, 2; 27-35
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of extraneous waters on the proportion of sewage pollution indices regarding its biological treatment
Autorzy:
Kaczor, G.
Bergel, T.
Bugajski, P.
Powiązania:
https://bibliotekanauki.pl/articles/59684.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
extraneous water
proportion
sewage
pollution index
biological treatment
denitrification
dephosphatation
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2015, IV/3
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zmian jakości ścieków w trakcie procesów oczyszczania na oczyszczalni w Przemyślu
The analysis of the changes in the sewage quality during treatment processes on the wastewater treatment plant in Przemyśl
Autorzy:
Młyńska, A.
Chmielowski, K.
Młyński, D.
Powiązania:
https://bibliotekanauki.pl/articles/401056.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ścieki
oczyszczanie mechaniczno-biologiczne
rozkład biologiczny
sewage
mechanical-biological treatment
biodegradability
Opis:
W oparciu o odnotowane wielkości BZT5, ChZTCr, azotu ogólnego (Nog.) i fosforu ogólnego (Pog.) w ściekach unieszkodliwianych w 2015 roku na oczyszczalni w Przemyślu dokonano oceny ich podatności na rozkład biologiczny. Przeprowadzona analiza wykazała, że skład ścieków surowych zapewniał właściwy przebieg i efektywność procesów biochemicznych, na co wskazują wyznaczone wartości ilorazów ChZTCr/BZT5, Nog./BZT5, Pog./BZT5. Ponadto, przeanalizowano zmiany wartości wskaźników zanieczyszczeń w ściekach po kolejnych etapach oczyszczania. W miarę postępującego procesu oczyszczania następowało stopniowe obniżanie ilości zanieczyszczeń organicznych i związków biogennych, których to największa redukcja osiągnięta została w wyniku procesów biologicznych. Wyniki te świadczą o prawidłowości przebiegu procesów zachodzących na pracującej w układzie dwustopniowym przemyskiej oczyszczalni.
On the basis of the noted BOD5, CODCr, total nitrogen (Ntot.) and total phosphorus (Ptot.) values in sewage treated in 2015 on the Wastewater Treatment in Przemyśl, the evaluation of the sewage biodegradability was performed. The conducted analysis showed that the composition of raw sewage provided proper biochemical processes and its effectiveness, which is evidenced by the calculated COD,sub>Cr/BOD5, Ntot./BOD5 and Ptot/BOD5 ratios. Moreover, the changes of pollutants indicators in the sewage after the next treatment stages were analyzed. As the sewage treatment process progressed, there was a gradual reduction of the organic and biogenic compounds. The largest reduction was achieved as a result of biological processes. The obtained results indicate the reliability of treatment processes in the two-stage system of Przemyśl wastewater treatment plant.
Źródło:
Inżynieria Ekologiczna; 2017, 18, 5; 18-26
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The impact of the sewer system rinsing on the wastewater composition
Autorzy:
Sadecka, Z.
Płuciennik-Koropczuk, E.
Myszograj, S.
Suchowska-Kisielewicz, M.
Jakubaszek, A.
Powiązania:
https://bibliotekanauki.pl/articles/207804.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
sewers
pollution
sewage
sewage pumping plants
water treatment plants
biological reactor
sewage pollutions
wastewater treatment plants
kanalizacja
ścieki
przepompownie ścieków
stacje uzdatniania wody
reaktor biologiczny
zanieczyszczenia ścieków
oczyszczalnie ścieków
Opis:
The paper presents the results of research on the influence of the operational rinsing of a sewer system on the composition of raw sewage, the effectiveness of the operation of the mechanical part of a wastewater treatment plant and changes in the technological parameters of the biological reactor. The results of the research have shown an increase in sewage pollution during the rinsing of the sewer system. The value of the COD indicator increased from 799 to 1306 mg/dm3, BOD5 from 538 to 1044 mg/dm3, and total suspended solids from 259 to 1508 mg/dm3. The calculations indicate that an increase in the concentrations of pollution during the rinsing of the sewer system requires a high working efficiency of the mechanical part of the wastewater treatment plant. With a low efficiency the volume of the biological reactor can increase even by 30%.
Źródło:
Environment Protection Engineering; 2013, 39, 2; 5-13
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of post-sewage waters on relations between exchangeable cations in soils
Autorzy:
Dechnik, I
Filipek, T.
Powiązania:
https://bibliotekanauki.pl/articles/1449943.pdf
Data publikacji:
2001
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
post-sewage water
relationship
soil
municipal waste
cation
biogenic component
soil property
eroded soil
degraded ecosystem
mechanical-biological treatment plant
anthropogenic ecosystem
sewage
Opis:
Research was carried out on the basis of investigations from the years 1996-1998 on the so-called monoliths in the soils derived from loess formations. Properties of those formations were differentiated by landscape and processes of water erosion. It was found out that post-sewage waters (waters received after sewage treatment) from a mechanical-biological sewage treatment plant have a more favourable influence on both the value of acidification indexes and relations between cations in the soils than solid mineral salts.
Źródło:
Acta Agrophysica; 2001, 51; 29-35
1234-4125
Pojawia się w:
Acta Agrophysica
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies