Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "odsalanie" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Application of a Hybrid Uf-RO Process to Geothermal Water Desalination : Concentrate Disposal and Cost Analysis
Wykorzystanie hybrydowego procesuUF-RO w odsalaniu wód geotermalnych : utylizacja koncentratu i analiza kosztów
Autorzy:
Tomaszewska, B.
Pająk, L.
Bodzek, M
Powiązania:
https://bibliotekanauki.pl/articles/204638.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
desalination
geothermal water
reverse osmosis
costs analysis
concentrate disposal
odsalanie
wody geotermalne
odwrócona osmoza
analiza kosztów
utylizacja koncentratu
Opis:
Membrane-based water desalination processes and hybrid technologies are often considered as a technologically and economically viable alternative for desalination of geothermal waters. This has been confirmed by the results of pilot studies concerning the UF-RO desalination of geothermal waters extracted from various geological structures in Poland. The assessment of the feasibility of implementing the water desalination process analysed on an industrial scale is largely dependent on the method and possibility of disposing or utilising the concentrate. The analyses conducted in this respect have demonstrated that it is possible to use the solution obtained as a balneological product owing to its elevated metasilicic acid, fluorides and iodides ions content. Due to environmental considerations, injecting the concentrate back into the formation is the preferable solution. The energy efficiency and economic analysis conducted demonstrated that the cost effectiveness of implementing the UF-RO process in a geothermal system on an industrial scale largely depends on the factors related to its operation, including without limitation the amount of geothermal water extracted, water salinity, the absorption parameters of the wells used to inject water back into the formation, the scale of problems related to the disposal of cooled water, local demand for drinking and household water, etc. The decrease in the pressure required to inject water into the formation as well as the reduction in the stream of the water injected are among the key cost-effectiveness factors. Ensuring favourable desalinated water sale terms (price/quantity) is also a very important consideration owing to the electrical power required to conduct the UF-RO process.
Odsalanie wody z wykorzystaniem procesów membranowych oraz technologii hybrydowych rozważane jest jako technologiczna i ekonomiczna alternatywa dla klasycznych metod utylizacji wykorzystanych wód geotermalnych. Taką możliwość potwierdziły przeprowadzone badania pilotowe odsalania w systemie UF-RO wód geotermalnych eksploatowanych w obrębie różnych struktur geologicznych Polski. Ocena możliwości wdrożenia tych rozwiązań na skalę przemysłową, w dużej mierze zależy od kierunków i możliwości utylizacji/ zagospodarowania koncentratu. Przeprowadzone analizy w tym zakresie wykazały możliwość wykorzystania uzyskanego roztworu jako produktu o cechach balneologicznych, z uwagi na podwyższoną zawartość: kwasu metakrzemowego oraz jonów fluorkowych i jodkowych. Biorąc pod uwagę jednak względy środowiskowe, alternatywnym rozwiązaniem może być wtłaczanie koncentratu do górotworu. Przeprowadzona analiza energetyczna i ekonomiczna wykazała, iż opłacalność wdrożenia na skalę przemysłową procesu UF-RO w systemie geotermalnym w dużej mierze zależy od czynników związanych z jego pracą, a w szczególności: wielkości wydobycia wód geotermalnych, zasolenia wód, parametrów chłonnych otworów przeznaczonych do wtłaczania wód do górotworu, skali problemów związanych z utylizacją schłodzonych wód, lokalnego zapotrzebowania na wody pitne i gospodarcze i in. Kluczowa dla opłacalności tego procesu jest między innymi redukcja wymaganego ciśnienia przy wtłaczaniu wód do górotworu i redukcja wielkości strumienia zatłaczanych wód. Bardzo ważnym elementem jest również zapewnienie odpowiednich warunków zbytu odsolonych wód (cena/ilość) celem pokrycia zapotrzebowania na energię elektryczną wykorzystaną w procesie UF-RO.
Źródło:
Archives of Environmental Protection; 2014, 40, 3; 137-151
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary studies for the desalination of model solution of flowback water from shale gas production in the NF/RO pilot plant
Badania nad możliwością odsalania modelowego roztworu płynu powrotnego ze szczelinowania hydraulicznego złóż gazu łupkowego w pilotowej instalacji NF/RO
Autorzy:
Rajewski, J.
Kowalik-Klimczak, A.
Szwast, M.
Gierycz, P.
Powiązania:
https://bibliotekanauki.pl/articles/257475.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
nanofiltration
NF
reverse osmosis
RO
desalination
flowback water
shale gas
nanofiltracja
odwrócona osmoza
odsalanie
płyn powrotny
gaz łupkowy
Opis:
The impact of selected process parameters of an integrated NF/RO system on possibilities of the desalination of model solutions, containing salts in typical concentrations for flowback water from shale gas production, was analyzed in this work. Based on the results of studies carried out in the pilot scale, it was found that the integrated NF/RO system allows for satisfactory reduction of the model solution of flowback water mineralization. It can be stated that the use of NF/RO system enables the re-use of the “real” flowback water during hydraulic fracturing.
W pracy zbadano wpływ wybranych parametrów procesowych zintegrowanego systemu NF/RO na możliwość odsalania modelowych roztworów zawierających sole w stężeniach charakterystycznych dla płynu powrotnego ze szczelinowania złóż gazu z łupków. Na podstawie otrzymanych wyników badań prowadzonych w skali pilotowej, stwierdzono, że zintegrowany układ NF/RO pozwala na zadowalające zmniejszenie mineralizacji roztworu modelowego płynu powrotnego. Można zatem założyć, iż zastosowanie układu NF/RO umożliwi ponowne wykorzystanie ścieku rzeczywistego podczas szczelinowania hydraulicznego.
Źródło:
Problemy Eksploatacji; 2016, 3; 155-164
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design of a Solar Powered Reverse Osmosis System in Egypt
Autorzy:
Ibrahim, Said M. A.
Shabak, Ahmed G. M.
Powiązania:
https://bibliotekanauki.pl/articles/2052247.pdf
Data publikacji:
2021
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
reverse osmosis
photovoltaic
total dissolved solids
TDS
pvro
desalination
odwrócona osmoza
fotowoltaika
całkowita ilość rozpuszczonych w płynie substancji
odsalanie
Opis:
Scarcity of fresh water, forced many countries to get their water needs, or part of it, by means of saline water desalination. Reverse osmosis (RO) systems are useful tools in this concern. In case the grid electricity is not available or costly, photovoltaic (PV) power is necessary to derive RO systems. The present paper is concerned with providing a methodology for complete sizing and design of a photovoltaic reverse osmosis (PVRO) system in Egypt. Egypt has very favorable solar energy. A computer program was constructed to solve the mathematical equations of the model to get the numerical values. The program is capable of calculating the solar irradiation for any city in Egypt. Calculations and selection of the RO system with all connected pumps, the peak PV power needed, and the actual PV area were performed for different water demands ranging from 1-100 m3/day, and various water total dissolved solids (TDSs) of 5000, 15000, and 30000 mg/l. The cost of the complete PVRO system was also determined. The concern of the paper is related to water desalination and solar energy, which are responsible for our existence. The work also aims toward sustainable and clean environment via utilizing solar energy.
Źródło:
Journal of Mechanical and Energy Engineering; 2021, 5, 2; 125-140
2544-0780
2544-1671
Pojawia się w:
Journal of Mechanical and Energy Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zagospodarowanie schłodzonych i odsolonych wód termalnych w Podhalańskiej Sieci Ciepłowniczej
Cooled and desalinated thermal water utilization in the Podhale Heating System
Autorzy:
Tomaszewska, B.
Pająk, L.
Powiązania:
https://bibliotekanauki.pl/articles/216572.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
odsalanie wody
ultrafiltracja
odwrócona osmoza
geotermia
straty wody sieciowej
ciepłownictwo
water desalination
ultrafiltration
reverse osmosis
geothermics
network water losses
district heating
Opis:
Woda obiegowa w instalacjach ciepłowniczych musi posiadać odpowiednie parametry fizykochemiczne, uzależnione od wymagań technicznych producentów urządzeń, przez które przepływa. Nie powinna powodować powstawania kamienia kotłowego, pienić się oraz korozyjnie oddziaływać na elementy instalacji. W pracy przedstawiono badania dotyczące oceny możliwości wykorzystania odpadowych wód termalnych w celu uzupełnienia ubytków wody sieciowej w największym polskim geotermalnym systemie ciepłowniczym zlokalizowanym w obrębie niecki podhalańskiej. Obszar ten cechuje się dużymi zasobami wód termalnych, a jednocześnie deficytem wód zwykłych. Odpadowe wody termalne ze względu na wykazywane parametry fizykochemiczne mogą być wykorzystane w systemie dopiero po uzdatnieniu. Podczas badań zagospodarowana i uzdatniana była jedynie część całkowitego strumienia wody geotermalnej (do 5 m3/h), odpowiadająca mniej więcej zapotrzebowaniu systemu ciepłowniczego na świeżą uzdatnioną wodę obiegową (ok. 550 m3/miesiąc). Ubytki wody sieciowej wynikają z nieszczelności sieci, prowadzenia remontów, modernizacji lub obsługi sieci. Oczyszczanie przeprowadzone zostało z wykorzystaniem procesów membranowych w zintegrowanym systemie złożonym z ultrafiltracji (UF) i dwóch niezależnych stopni odwróconej osmozy (RO-1 i RO-2) połączonych szeregowo. Uzdatnianie prowadzone było przy częściowym wykorzystaniu artezyjskiego ciśnienia złożowego, co pozwoliło zredukować moc pomp obiegowych eliminując zużycie energii o około 0,7–0,9 kW. Dzięki podwyższonej temperaturze wody uzdatnionej zredukowana została moc cieplna o około 30 kW oraz efektywniej prowadzone były procesy oczyszczania i odgazowania wody. Uzyskano redukcję: zawartości żelaza ze stężenia około 4 do 0,013 g/m3, twardości ogólnej z 13,5 val/m3 do <0,02 val/m3, zasadowości z 4,45 val/m3 do <0,01 val/m3, fosforanów z 0,03 do <0,006 g/m3, uzyskując spełnienie wymagań określonych w normach, co po korekcie pH i odgazowaniu pozwala wykorzystać uzdatnione wody geotermalne dla uzupełnienia ubytków wody sieciowej w systemie ciepłowniczym. Polska Norma PN-85/C-04601 nie specyfikuje wymagań w zakresie dopuszczalnego stężenia m.in. chlorków i siarczanów w wodzie obiegowej, a więc anionów wpływających na korozyjność wody, głównie wżerową. Jony te tworzą rozpuszczalne związki z metalami, utrudniając powstawanie i wytrącanie tlenków metali. Zastosowanie przedstawionej technologii membranowej w odsalaniu wód termalnych pozwoliło na uzyskanie wysokiego stopnia retencji. Wynosi on dla chlorków 97% po RO-1 i 99% po RO-2, natomiast dla siarczanów 99% już po RO-1.
Distribution water that circulates in heating installations must meet certain parameters depending on the technical requirements set by the manufacturers of the equipment through which it flows. It should not cause scaling of boilers, should not corrode parts of the installation and should not foam. This paper examines the proposition the used of geothermal water to replenish network water losses in the largest Polish geothermal heating system located within the Podhale Basin reservoir. The area in question has considerable geothermal water resources while at the same time exhibiting a fresh water deficit. Only part of the total volume of geothermal water (up to 5 m3/h) was used and treated; this is roughly equivalent to the district heating system demand for treated fresh distribution water (ca. 550 m3/month). The treatment uses membrane processes within the framework of a integrated arrangement including ultrafiltration (UF) and two independent reverse osmosis stages (RO-1 and RO-2) connected in series. Artesian pressure was used to a certain extent during the treatment, which makes it possible to reduce the power required for the distribution pump, decreasing electrical power consumption by ca. 0.7–0.9 kW. Thanks to the fact that the temperature of the water to be treated is higher than the public supply, the thermal capacity requirement was reduced (30 kW) and both water treatment and degassing processes are more efficient. Iron content was reduced from ca. 4 to 0.013 g/m3, total hardness was reduced from 13.5 eq/m3 to <0.02 eq/m3, alkalinity was reduced from 4.45 eq/m3 to <0.01 eq/m3 and phosphate content was reduced from 0.03 to <0.006 g/m3. Thus the requirements set forth in the standards have been met and the treated geothermal water can be used to replenish network water losses in the district heating system following pH adjustment and degassing. The PN-85/C-04601 Polish Standard does not specify any requirements concerning the admissible concentrations of, inter alia, chloride and sulphate ions, i.e. anions that affect water corrosivity, mostly pitting corrosivity. These ions form soluble compounds with metals and thereby inhibit the formation and precipitation of metal oxides. The use of the membrane technology discussed here in the desalination of geothermal waters, also made it possible to achieve high retention coefficients – 97% after RO-2 for chlorides and 99% for sulphates already after RO-1.
Źródło:
Gospodarka Surowcami Mineralnymi; 2013, 29, 1; 127-139
0860-0953
Pojawia się w:
Gospodarka Surowcami Mineralnymi
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies