Tytuł:
Analysis of pumping unit reducers diagnostic algorithms by formalized methods
Analiza algorytmów diagnostyki reduktorów jednostek pomp za pomocą metod formalnych
Autorzy:
Kopey, B. V.
Stefanyshyn, O. I.
Bednarz, S.
Powiązania:
https://bibliotekanauki.pl/articles/299165.pdf
Data publikacji:
2012
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
jednostka pomp
reduktor
przekładnie
uszkodzenia
model diagnostyczny
algorytm
pumping unit
reducer
gears
defect
diagnostic model
algorithm
Opis:
Diagnostic model of pumping unit reducer is designed for the construction and analysis of algorithms by diagnosing formalized methods. The using of the diagnostic model allows us to ease and formalize decisions on the diagnostic problem. For the synthesis of algorithm for diagnosing the functional-logical model has been selected, which allows to consider the links between individual elements and assemblies of the reducer by simple means and consider the impact of these items on measuring diagnostic features. For a more detailed study of processes occurring in the gearbox of pumping unit, and facilitate the development of its diagnostic model, a functional diagram of reducing gear was built. Diagnostic logic model will help to establish and classify defects in development, to determine the direction of their development and cause-effect relationship with other defects.
Diagnostyczny model reduktora jednostki pomp zaprojektowano w celu zbudowania i przeanalizowania algorytmów za pomocą metod formalnych. Wykorzystanie modelu diagnostycznego ułatwia i formalizuje proces decyzyjny w kwestiach diagnostyki. W celu scalenia algorytmu diagnostycznego zastosowano model funkcjonalno-logiczny umożliwiający przeanalizowanie powiązań między poszczególnymi elementami a zestawami reduktora za pomocą prostych środków oraz rozważenie wpływu tych elementów na pomiar cech diagnostycznych. W celu umożliwienia bardziej szczegółowych badań procesów występujących w skrzyni przekładniowej jednostki pomp oraz w celu opracowania modelu diagnostycznego stworzono funkcjonalny schemat przekładni redukcyjnej. Logiczny model diagnostyczny pozwoli ustalić i sklasyfikować pojawiające się uszkodzenia, określić ich kierunek rozwoju oraz mechanizmy przyczynowo-skutkowe z innymi uszkodzeniami.
Źródło:
AGH Drilling, Oil, Gas; 2012, 29, 1; 207-215
2299-4157
2300-7052
Pojawia się w:
AGH Drilling, Oil, Gas
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prediction of pumping units reducers resource
Autorzy:
Kopey, B. V.
Bednarz, S.
Steafanyshyn, O. I.
Powiązania:
https://bibliotekanauki.pl/articles/299209.pdf
Data publikacji:
2014
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
pumping unit
reducer
vibration
monitoring
residual resource
sensor
Opis:
Periodic monitoring of pumping units reducer vibration allow for a prediction of its full or residual resource to the next repair, which can be estimated on the basis of extrapolation methods and classification . Considering these two methods, we can say that the advantage extrapolation method has its accuracy and the possibility of adaptation to each specific gear, and the disadvantages include its complexity and the need to respect the conditions of constant change over time the vibration characteristics of the selected gear by law. In the application of classification method, which is simple, you need to process a certain amount of statistical data derived from the operation of machines, swing or perform experiments on a special stand that is relatively complex. In addition, the practice shows that the use of statistical techniques often makes accurate predictions due to the large gap modes of machines, swing and various properties of the pumped wells product, so the decision was made in solving this problem use the method of construction and extrapolation of time trend change of gear operating parameters. In Borislav CBPC the diagnostic examination of a number of reducers RN -2300 were conducted and the optimal level of vibration determined, whereby it can be concluded the qualitative repair of this type of gear . Some sensors during testing were installed on the gear housing near the output shaft. The average frequency of rotation of the input shaft gear was during vibroobservations was obtained respectively: /vh = 3.9 Hz and /vh = 3.53 Hz. Processing of the results was conducted by software MathCAD. Acceptable level of vibration that is recommended by standard GOST ISO 8579-2-2002 for gear RN -2300 is 8.3 mm / s, which can be used to determine its suitability for further exploitation . According to calculations conducted by an appropriate method the acceptable level of vibration above mentioned gear is 3.1 mm / s. These valid values are in good agreement with the experimental values and have a lower level compared to the standard recommendations. According to conducted researches the curve of resource prediction for gear of pumping unit has been plotted. Thus, the expected service life of the gear RN -2300 of pumping unit will be approximately 36-38 thousand hours.
Źródło:
AGH Drilling, Oil, Gas; 2014, 31, 1; 117-122
2299-4157
2300-7052
Pojawia się w:
AGH Drilling, Oil, Gas
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies