Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "frakcje ChZT" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
COD fractions - methods of measurement and use in wastewater treatment technology
Frakcje CHZT - metody pomiaru oraz zastosowanie w technologii oczyszczania ścieków
Autorzy:
Myszograj, S.
Płuciennik-Koropczuk, E.
Jakubaszek, A.
Świętek, A.
Powiązania:
https://bibliotekanauki.pl/articles/396702.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
COD fractions
raw wastewater
methods of measurement
frakcje ChZT
ścieki surowe
metody pomiaru
Opis:
The paper presents the results of studies concerning the designation of COD fraction in raw wastewater. The research was conducted in four municipal mechanical-biological sewage treatment plants and one industrial sewage treatment plant. The following fractions of COD were determined: non-biodegradable (inert) soluble SI, biodegradable soluble fraction SS, particulate slowly degradable XS and particulate non-biodegradable XI. The methodology for determining the COD fraction was based on the ATV-A131 guidelines and Łomotowski-Szpindor methodology. The real concentration of fractions in raw wastewater and the percentage of each fraction in total COD are different from data reported in the literature.
W artykule przedstawiono wyniki badań, których celem było wyznaczanie frakcji ChZT w ściekach surowych. Badania przeprowadzono w czterech komunalnych mechaniczno-biologicznych oczyszczalniach ścieków i oczyszczalni ścieków przemysłowych. Określono następujące frakcje ChZT: inertna rozpuszczona SI, biodegradowalna rozpuszczona SS, związana w zawiesinie biologicznie łatworozkładalnej XS i związana w zawiesinie nieulegająca biodegradacji XI. Metodologia określania frakcji ChZT została oparta na wytycznych ATV-A131 i metodologii Łomotowskiego-Szpindora. Uzyskany udział frakcji w całkowitym ChZT w ściekach surowych różnił się od danych literaturowych.
Źródło:
Civil and Environmental Engineering Reports; 2017, No. 24(1); 197-208
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka ścieków surowych na podstawie frakcji ChZT
Characteristic of raw wastewater based on cod fractions
Autorzy:
Sadecka, Z.
Płuciennik-Koropczuk, E.
Sieciechowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/296933.pdf
Data publikacji:
2011
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
ścieki surowe
frakcje ChZT
modele ASM
zanieczyszczenia biode gradowalne i niebiodegradowalne
raw wastewater
COD fractions
ASM models
organic substances biodegradable and non-biodegradable
Opis:
Przedstawiono ogólną charakterystykę frakcji ChZT w ściekach surowych oraz wyniki badań stężeń frakcji ChZT w ściekach surowych dopływających do oczyszczalni o RLM > 100 000. Wyniki badań rzeczywistych porównano z danymi przyjmowanymi w modelach biokinetycznych typu ASM. W surowych ściekach oznaczano frakcje biodegradowalne SS i XS oraz niebiodegradowalne SI i XI. Stężenia frakcji wyznaczano na podstawie wytycznych ATV-A 131. Wyznaczone w warunkach rzeczywistych stężenia oraz procentowe udziały poszczególnych frakcji ChZT w ściekach surowych różnią się od danych zamieszczonych w literaturze.
According to the literature the percentage of the suspension fraction in the total COD of raw municipal wastewater is 65 ÷ 79% and dissolved 21 ÷ 35%. It is also understood that the percentage of suspended solids in municipal wastewater is about 57% of COD and colloids and dissolved substances about 43%. In the biokinetic models like ASM the percentages of individual fractions in the total COD is: in ASM1 XS = 70%, SS = 15%, XI = 10%, SI = 5%, while in ASM2: XS = 35 ÷ 75%, SS = 12 ÷ 30%, XI = 10 ÷ 15%, SI = 5 ÷ 10%. The paper presents the general characteristics of COD fractions of raw wastewater and the results of COD fractions concentrations in the raw wastewater flowing into treatment plant with population equivalent > 100 000. In the raw effluent from sewage treatment plant biodegradable fractions SS and XS and non-biodegradable fractions SI and XI were determined. Concentrations of each fractions were determined on the basis of guidelines ATV A -131. During the study in the raw wastewater organic pollutants measured as CODCr values were from 528 to 768 mgO2/dm3. The values of the total COD of raw wastewater was appointed as the sum of each fraction varied from 621.0 ± 14.1 to 747.8 ± 139.2 mgO2/dm3 depending on the season. Based on the concentration of each fraction the percentage of each fraction in the total COD were determined. The values of the percentage of each fraction in total COD were compared with data received in biokinetic models like ASM. The designated real concentration of each COD fraction in raw wastewater and the percentage of each fraction in total COD are different from the data reported in the literature. The results showed that in raw wastewater in the highest concentrations occur in succession fraction XS, then SS, XI and SI. This order is consistent with biokientic models. Significant differences between the research and models assumptions concerning the range of content of each fraction. The percentage of COD fractions in the raw wastewater from wastewater treatment plant "Łącza" were set at: XS = 49.3 ÷ 53.4% SS = 23.9 ÷ 30.4% XI = 16.4 ÷ 17.8% SI = 2.9 ÷ 4.9 %. More than 75% of the total COD in the raw wastewater were biodegradable fractions (the sum of SS and XS fractions). The XS fraction accounted between 49.3 to 53.4% of the total COD and the SS fraction from 23.9 to 30.4% of the total COD. The contents of XI fraction was at 16.4 ÷ 17.8% of the total COD. The smallest share of the total COD of raw wastewater was fraction SI. The research results showed that in the raw wastewater the percentage of XI and SS fraction is higher and a the percentage of SI and XS fractions is lower compared with the assumptions in models ASM1 and ASM2. The real concentration of each fraction and the percentage of each fraction in the total COD determined in the raw wastewater should be the basis for calibrating models used in modeling and controlling the operation of the wastewater treatment plant.
Źródło:
Inżynieria i Ochrona Środowiska; 2011, 14, 2; 145-156
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
COD fractions in raw and mechanically treated wastewater
Frakcje ChZT w ściekach surowych i mechanicznie oczyszczonych
Autorzy:
Płuciennik-Koropczuk, E.
Sadecka, Z.
Myszograj, S.
Powiązania:
https://bibliotekanauki.pl/articles/396162.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
raw wastewater
COD fractions
ASM models
mechanical treatment
substances biodegradable
organic substances
ścieki surowe
Frakcje ChZT
modele ASM
oczyszczanie mechaniczne
substancje biodegradowalne
substancje organiczne
Opis:
The paper presents results of studies concerning the designation of COD fraction in the raw and mechanically treated wastewater in different year seasons. The research object was a mechanical-biological wastewater treatment plant with the output of >40 000 P.E., located in western Poland. The results of COD fraction in the raw wastewater were compared with data received in the ASM models. Methodology for determining the COD fraction was based on the guidelines ATV - A 131. During the research following fractions were determined: particulate slowly biodegradable substrates (Xs), soluble readily biodegradable substrates (Ss), inert particulate organic material (Xr) and inert soluble organic material (Sr). Soluble and particulate components were differentiated by filtration through 0.45μm membrane filters. The percentage of each fraction in total COD determined on the real concentration in raw wastewater are different from data reported in the literature.
W artykule przedstawiono wyniki badań dotyczące frakcji ChZT w ściekach surowych i mechanicznie oczyszczonych w piaskowniku. Badania prowadzono w mechaniczno-biologicznej oczyszczalni ścieków o wielkości>40 000 RLM, zlokalizowanej w zachodniej Polsce. Próbki do badań pobierano w różnych porach roku. Metodyka wyznaczania frakcji ChZT została opracowana w oparciu o wytyczne ATV-131. Podczas badań określono następujące frakcje: substancje organiczne w zawiesinie, biologicznie wolno rozkładalne (Xs), rozpuszczone substancje organiczne, biologicznie łatwo rozkładalne, (Ss), substancje organiczne w zawiesinie, biologicznie trudno rozkładalne (Xr) i rozpuszczone substancje organiczne, biologicznie nierozkładalne (Sr). Rozdziału frakcji rozpuszczonych i w zawiesinie dokonano przez filtrację próbek ścieków przez filtry membranowe o wielkości porów 0,45 μm. Wyniki badań wykazały, że zarówno w ściekach surowych jak i oczyszczonych mechanicznie udział frakcji biodegradowalnych wynosił ok. 80% całkowitego ChZT. Oczyszczanie ścieków w piaskowniku spowodowało obniżenie stężenia zanieczyszczeń organicznych o ok. 30% oraz wpływało na zmiany w udziale frakcji rozpuszczonych i w zawiesinie. Wartości procentowego udziału frakcji XS i XI w ściekach po piaskowniku zmalały, podczas gdy wartości procentowego udziału frakcji Ss i Sr wzrosły, w stosunku do ich udziału w ściekach surowych. Udział procentowy frakcji ChZT w ściekach surowych wyznaczony w badaniach różni się od danych zawartych w modelach ASM1 i ASM 2.
Źródło:
Civil and Environmental Engineering Reports; 2013, 11; 101-113
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies