Conditions for the use of infrared camera diagnostics in energy auditing of the objects exposed to open air space at isothermal sky
Autorzy:
Kruczek, T.
Powiązania:
https://bibliotekanauki.pl/articles/240912.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermovision diagnostics
infrared camera
radiative ambient temperature
open air space
diagnostyka termowizyjna
kamera termowizyjna
radiacyjna temperatura otoczenia
otwarta przestrzeń
Opis:
Convective and radiation heat transfer take place between various objects placed in open air space and their surroundings. These phenomena bring about heat losses from pipelines, building walls, roofs and other objects. One of the main tasks in energy auditing is the reduction of excessive heat losses. In the case of a low sky temperature, the radiation heat exchange is very intensive and the temperature of the top part of the horizontal pipelines or walls is lower than the temperature of their bottom parts. Quite often this temperature is also lower than the temperature of the surrounding atmospheric air. In the case of overhead heat pipelines placed in open air space, it is the ground and sky that constitute the surroundings. The aforementioned elements of surroundings usually have different values of temperature. Thus, these circumstances bring about difficulties during infrared inspections because only one ambient temperature which represents radiation of all surrounding elements must be known during the thermovision measurements. This work is aimed at the development of a method for determination of an equivalent ambient temperature representing the thermal radiation of the surrounding elements of the object under consideration placed in open air space, which could be applied at a fairly uniform temperature of the sky during the thermovision measurements as well as for the calculation of radiative heat losses.
Źródło:
Archives of Thermodynamics; 2015, 36, 1; 67-82
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie rozkładów temperaturowych dla nieboskłonu w oparciu o wyniki pomiaru kamerą termowizyjną
Determination of Temperature Distributions for the Sky Based on the Results of Measurement with an Infrared Camera
Autorzy:
Kruczek, Tadeusz
Powiązania:
https://bibliotekanauki.pl/articles/2068626.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
pomiar termowizyjny
radiacyjna temperatura otoczenia
temperatura nieboskłonu
pomiar temperatury nieboskłonu
profil temperaturowy nieboskłonu
thermovision measurement
radiation ambient temperature
sky temperature
sky temperature measurement
temperature profile of the sky
Opis:
Otoczenie obiektów znajdujących się w otwartej przestrzeni atmosferycznej składa się zwykle z hipotetycznej powierzchni nieboskłonu i powierzchni gruntu. Celem badań termowizyjnych takich obiektów, zwłaszcza budynków, jest określenie wielkości strat ciepła lub ocena parametrów jakościowych izolacji ścian, dachów i innych przegród. Badane powierzchnie, w tym elementy zewnętrznej powłoki budynków, są często usytuowane pod różnymi kątami w stosunku do powierzchni terenu i nieboskłonu. Na potrzeby badań termowizyjnych rozpatrywanych obiektów oraz obliczeń dotyczących radiacyjnej wymiany ciepła niezbędna jest znajomość parametrów radiacyjnych nieboskłonu. Parametry te obejmują równoważną radiacyjną temperaturę otoczenia potrzebną do pomiarów termowizyjnych (w tym temperaturę nieboskłonu i gruntu) oraz ogólną radiacyjną temperaturę otoczenia, która decyduje o stracie ciepła przez promieniowanie z badanej powierzchni. Artykuł zawiera opis metody wyznaczania wartości wymienionych rodzajów temperatury na podstawie pomiaru temperatury nieboskłonu za pomocą długofalowej kamery termowizyjnej oraz obliczeń. W celu weryfikacji opracowanej metody porównano wyniki uzyskane za pomocą tej metody z wynikami pomiarów otrzymanymi za pomocą pyrgeometru. Weryfikacja obejmowała porównanie strumienia cieplnego promieniowania nieboskłonu obliczonego na podstawie pomiarów termowizyjnych ze strumieniem energii emitowanym przez nieboskłon i mierzonym za pomocą pyrgeometru. Wynik weryfikacji jest satysfakcjonujący.
The surroundings of objects in an open atmospheric space usually consist of a hypothetical surface of the sky and the surface of the ground. The aim of thermovision examination of objects located in open atmospheric space, especially buildings, is to determine the amount of heat loss or to assess the insulation quality parameters of walls, roofs and other building partitions. The tested surfaces, including elements of the outer shell of buildings, are often located at different angles to the ground surface and the sky. For the needs of thermovision testing of the considered objects and calculations concerning the radiation heat transfer, it is necessary to know the radiation parameters of the sky. These parameters include the equivalent radiative ambient temperature needed for thermovision measurements (including the temperature of the sky and the ground) and the overall radiative ambient temperature, which determines the heat loss by radiation from the tested surface. The article describes the method of determining the values of these temperatures on the basis of measuring the temperature of the sky with the use of a long-wave infrared camera and calculations. In order to verify the developed method, the results obtained with the use of the above-mentioned method were compared with the results obtained with the use of a pyrgeometer. The verification comprised the comparison of the heat flux of radiation from the sky, calculated on the basis of infrared camera measurements, with the energy flux emitted by the sky and measured with a pyrgeometer. The result of the verification is satisfactory.
Źródło:
Pomiary Automatyka Robotyka; 2021, 25, 3; 57--63
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie radiacyjnej temperatury otoczenia przy pomiarach termowizyjnych w otwartej przestrzeni
Determination of radiative ambient temperature during measurements in open air space
Autorzy:
Kruczek, T.
Powiązania:
https://bibliotekanauki.pl/articles/157691.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiary termowizyjne
radiacyjna temperatura otoczenia
pomiary w otwartej przestrzeni
termowizyjna diagnostyka rurociągów
infrared measurements
radiative ambient temperature
thermovision diagnosis of pipelines
measurements in open air space
Opis:
Jednym z parametrów wpływającym na wyniki termowizyjnego pomiaru temperatury jest temperatura otoczenia. W przypadku pomiarów w otwar-tej przestrzeni (budynki, rurociągi i in.) otoczenie składa się z dwóch elementów: nieboskłonu i gruntu. Elementy te mają na ogół różne tempe-ratury. W pracy przedstawiono sposób pomiaru temperatury nieboskłonu, a następnie metodę wyznaczania temperatury izotermicznego otoczenia badanego obiektu zastępującego układ dwóch elementów otoczenia o różnych temperaturach: podłoża i nieboskłonu. W oparciu o opracowany model przeprowadzono obliczenia numeryczne, a wyniki przedstawiono na wykresach. Umożliwiają one określenie zastępczej temperatury otoczenia przy pomiarach termowizyjnych w otwartej przestrzeni.
During the thermovision inspection a few important parameters influence the results of temperature measurements. Among these parameters the emissivity of surface under consideration as well as the temperature of the ambient elements can be specified. In the case of overhead heat pipelines, convective and radiative heat transfers take place between thermal pipeline and its surroundings. Generally, the ambient of the external overhead pipeline consists of two surfaces: hypothetical sky and ground surface, Figs. 1, 2a. The method concerning the determination of apparent temperature of the hypothetical sky surface has been developed. The method is based on radiosity balances formulated for each considered element [1]. In this method the radiation of atmosphere towards the ground surface is substituted by the radiation of the assumed artificial surface, Fig. 1. As a result, the ambient system of two surfaces having different temperatures is obtained, Fig. 2a. Next, this system is converted into one-surface system and a method of expressing the radiation influence of these elements on the measurement result by means of one ambient temperature is developed. The aforementioned temperature is called an equivalent ambient temperature and can be calculated on the basis of equation (22). Numerical calculations have been carried out for the assumed typical data and results are shown in diagrams of Figs. 3, 4, 5. The diagrams allow estimating properly the representative ambient temperature in the case of infrared measurements of temperature in open air space.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 11, 11; 882-885
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies