Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "slab" wg kryterium: Temat


Wyświetlanie 1-7 z 7
Tytuł:
Realibility of the large size post-tensioned slab-on-grade
Niezawodność wielkogabarytowego kablobetonu jako płyt fundamentowych
Autorzy:
Tur, Andrei V.
Tur, Viktar V.
Powiązania:
https://bibliotekanauki.pl/articles/111033.pdf
Data publikacji:
2019
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
post-tensioned slab
punching shear
slab-on-grade
kablobeton
płyty fundamentowe
Opis:
The present article describes some of the possible ways of usage of the post-tensioned flat slabs and the rational design procedures to provide their structural reliability. Theoretical background of the punching resistance checking, in the case when the piles support the foundation pos-tensioned slabs, presented.For ground floor slabs, an iterative method given for determining design compression pre-stresses distribution in slab sections, taking into account the restrained effect created by the friction shear stresses in contact between slab and the base. In addition, the article presents some uncial practical implementations of the post-tensioned slabs as an artificial base in the presence of weak soils and as a large-size ground floor (slab-on-grade) without any joints.
W artykule opisano niektóre z możliwych sposobów wykorzystania płyt kablobetonowych oraz racjonalne procedury projektowe zapewniające ich niezawodność konstrukcyjną. Przedstawiono tło teoretyczne sprawdzenia wytrzymałości na przebicie w przypadku, gdy pale podtrzymują płyty fundamentowe są wstępnie naprężone. W przypadku płyt fundamentowych podano iteracyjną metodę wyznaczania obliczeniowego rozkładu naprężeń ściskających w przekrojach płyt, uwzględniającą efekt utwierdzenia wywołany naprężeniami ścinającymi w kontakcie płyty z podstawą. Ponadto, w artykule przedstawiono kilka praktycznych zastosowań płyt naprężonych jako sztucznego podłoża na gruntach słabych oraz jako wielkogabarytowe podłoże gruntowe (slab-on-grade) bez żadnych spoin.
Źródło:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych; 2019, 3
2450-1859
2450-8721
Pojawia się w:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nonlinear finite element analysis of punching shear strength of reinforced concrete slabs supported on L-shaped columns
Autorzy:
Zhang, Qing
Milligan, Graeme J.
Polak, Maria Anna
Powiązania:
https://bibliotekanauki.pl/articles/390883.pdf
Data publikacji:
2020
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
punching shear
finite element analysis
L-shaped columns
slab openings
Opis:
Most current concrete design codes include provisions for punching shear of reinforced concrete slabs supported on columns with L, T, and cruciform shapes. Reference studies verifying the accuracy of these code provisions are typically not provided. Empirical data of punching failures of slabs supported on columns with L, T, and cruciform shapes are limited due to the cost and time required to test specimens with slab thicknesses and column sizes commonly used in practice. In this paper, the punching shear behaviour of five interior L-shaped slab-column connections, one without a slab opening and four with slab openings, subjected to static concentric loading are analyzed using a plasticity-based nonlinear finite element model (FEM) in ABAQUS. The FEM is similar to models previously calibrated at the University of Waterloo and are calibrated considering nine slabs that are tested to study the impact of column rectangularity on the punching shear behaviour of reinforced concrete slabs. The finite element analysis results indicate that shear stresses primarily concentrate around the ends of the L, and that current code predictions from ACI 318-19 and Eurocode 2 may be unconservative due to the assumed critical perimeters around L-shaped columns.
Źródło:
Budownictwo i Architektura; 2020, 19, 4; 125-138
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of hybrid steel-polypropylene fiber on punching shear behavior of flat slab with an opening
Autorzy:
Zaezue, Shahzinan J.
Hadi, Waleed K.
Powiązania:
https://bibliotekanauki.pl/articles/36060590.pdf
Data publikacji:
2023
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
hybrid fiber
steel fiber
polypropylene fibre
punching shear
slab with opening
Opis:
This research aimed to gain a better understanding of how the addition of fiber influences the punching shear capacity of two-way slabs by conducting an experiment into the structural behavior of flat slabs with and without a square opening using different volume fractions of hybrid steel-polypropylene fiber (0%, 0.9%, 1.05% and 1.8%). Ten 700 × 700 × 70 mm slabs were divided into five pairs, with two samples used as control samples (with and without openings), and eight other samples with different volume fraction of fibers. Results showed that an increase in fiber content enhanced the shear strength of the slabs. For example, as the volume fraction of hybrid fiber increased from 0.0 to 1.8%, the ultimate load increased by 52% for slabs without an opening and up to 42% for slabs with an opening.
Źródło:
Scientific Review Engineering and Environmental Sciences; 2023, 32, 1; 3-17
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Projekt wybranych elementów konstrukcji budynku mieszkalnego ze stropami przewieszonymi z analizą zastosowania lekkiego betonu kruszywowego jako alternatywy betonu zwykłego
Detailed design of the selected structural elements of the residential building with overhang floor slabs including analysis of the use of LWAC as an alternative to NWC
Autorzy:
Nojek, Damian
Gołdyn, Michał
Powiązania:
https://bibliotekanauki.pl/articles/2142049.pdf
Data publikacji:
2022
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
strop płaski
płyta transferowa
beton lekki kruszywowy
przebicie płyty
analiza porównawcza
praca magisterska
flat slab
flat floor
transfer slab
lightweight aggregate concrete
punching shear
comparative analysis
master thesis
Opis:
W artykule przedstawiono projekt wielokondygnacyjnego budynku mieszkalnego ze stropami przewieszonymi i płytą transferową. W pracy analizowano zastosowanie lekkiego betonu kruszywowego jako alternatywy betonu zwykłego, z którego wykonano stropy międzykondygnacyjne. Omówione różnice we właściwościach i sposobie projektowania konstrukcji z obu rodzajów betonu. Dokonano porównania wyników obliczeń - m.in. sił wewnętrznych, ugięć, jak również zapotrzebowania na zbrojenie, a także przedstawiono uproszczoną analizę ekonomiczną obu rozwiązań.
The paper presents a design of the multi-storey residential building with overhang ceilings and transfer slab. The study analyses the use of lightweight aggregate concrete as an alternative to ordinary concrete, from which the inter-story ceilings were made. The differences in the properties and design principles of structural elements made of both types of concrete were discussed. The results of the calculations were compared - including i.a. internal forces, deflections and required reinforcement. A simplified economic analysis of both solutions was also presented.
Źródło:
Przegląd Budowlany; 2022, 93, 5-6; 55--62
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of load level of corner columns on punching shear resistance of flat slabs
Wpływ obciążenia słupa narożnego na nośność płyt płaskich z uwagi na przebicie
Autorzy:
Gołdyn, Michał
Urban, Tadeusz
Powiązania:
https://bibliotekanauki.pl/articles/390819.pdf
Data publikacji:
2020
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
column-slab connection
punching shear
lateral expansion
membrane action
normal stress
połączenia płyta-słup
przebicie
odkształcenia poprzeczne
efekt membranowy
naprężenia normalne
Opis:
The problem related to the effect of the corner column load on the punching shear resistance of the slab was presented. Existing experimental studies on internal columns demonstrated that the column pressure could lead to an increase in the punching shear resistance. Because of different confinement conditions of corner column-slab connection joints, it is unclear if such an effect exists for corner columns. New experimental investigations were initiated to clarify this issue. They covered a total of three corner column-slab connection specimens – slabs with a thickness of 140 mm and a longitudinal reinforcement ratio ρl = 1.09% connected with columns of a cross-section of 200×200 mm. The only variable parameter was the column load equal to 500, 1000 and 1500 kN. A reduction of the slab load-carrying capacity of about 9% due to a three-fold increase in the column load was noted. Therefore, the effect of the column load turned out to be opposite to that observed for most previous tests on internal column-slab connections, which could have a result of a limited capacity of the slab reinforcement due to additional tensile forces from the lateral expansion of joint concrete. Comparison in the light of test results demonstrated, that EN 1992-1-1 procedure allowed for safe, yet conservative estimation of the punching shear resistance. An average ratio of experimental to theoretical load of 1.82 was obtained.
W artykule przedstawiono zagadnienie wpływu obciążenia słupa narożnego na nośność płyty na przebicie. Dotychczasowe, nieliczne badania eksperymentalne dotyczące słupów wewnętrznych wykazały, iż nacisk słupa może prowadzić do zwiększenia nośności na przebicie. Z uwagi na odmienne warunki skrępowania węzłów skrajnych połączeń płytowo-słupowych konieczne było jednak zweryfikowanie tego efektu w odniesieniu do slupów narożnych. W tym celu wykonano i zbadano trzy modele połączeń płytowo-słupowych, wykonanych w skali. Wszystkie modele charakteryzowały się jednakową geometrią i zbrojeniem. Płyty o grubości 140 mm i stopniu zbrojenia podłużnego ρl = 1,09% połączone były ze słupami o przekroju 200×200 mm. Jedyny parametr zmienny stanowiło obciążenie słupa, równe 500, 1000 oraz 1500 kN. Wskutek trzykrotnego zwiększenia obciążenia słupa odnotowano zmniejszenie nośności na przebicie o około 9%. Efekt obciążenia słupa na nośność płyty okazał się zatem przeciwny do obserwowanego w przypadku większości badań połączeń wewnętrznych, czego przyczyny należy upatrywać w ograniczeniu nośności zbrojenia podłużnego płyty ze względu na odkształcenia poprzeczne betonu węzła. Porównanie wyników badań z obliczeniami według EN 1992-1-1 wykazało, iż procedura normowa pozwoliła na bezpieczne, aczkolwiek konserwatywne oszacowanie nośności modeli. Uzyskano bowiem średni stosunek nośności eksperymentalnej do teoretycznej równy 1,82.
Źródło:
Budownictwo i Architektura; 2020, 19, 3; 44-56
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Komentarz do zasad obliczania płyt na przebicie w strefie słupów narożnych według Eurokodu 2
Commentary to principles of eurocode 2 concerning punching shear of flat slabs within corner columns
Autorzy:
Gołdyn, M.
Urban, T.
Powiązania:
https://bibliotekanauki.pl/articles/104759.pdf
Data publikacji:
2017
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
przebicie
płyta
słup
słup narożny
Eurokod 2
moment niezrównoważony
naprężenie styczne
punching shear
column
slab structures
corner column
Eurocode 2
unbalanced moment
shear stresses
Opis:
W artykule omówiono zasady obliczania na przebicie płyt w strefie słupów narożnych. Omówiono cztery metody określania naprężeń stycznych, wynikających z działania momentu niezrównoważonego, przekazywanego z płyty na słup. Przedstawiono przykład liczbowy ilustrujący różnice w rozkładzie naprężeń stycznych na długości obwodu kontrolnego w zależności od zastosowanej procedury obliczeniowej. Dokonano porównania wyników obliczeń z rezultatami badań eksperymentalnych. Pokazano, iż w większości przypadków stosowanie zasad Eurokodu 2 prowadzi do wyników po stronie bezpiecznej, aczkolwiek rzeczywiste nośności zostały w wielu przypadkach znacznie niedoszacowane – w szczególności dotyczyło to obliczeń metodą ogólną. Najlepszą zgodność, przy zarazem satysfakcjonującym poziomie bezpieczeństwa obliczeń, uzyskano w przypadku zastosowania metody zredukowanych obwodów kontrolnych. Na podstawie przeprowadzonych analiz zalecono ponadto ograniczenie wartości współczynnika k, uwzględniającego udział mechanizmu przebicia w przekazywaniu momentu niezrównoważonego z płyty na słup.
The paper presents the provisions for punching shear within corner columns. Four methods of determining of shear stresses, resulting from acting of unbalanced moment, were discussed. An example showing the differences in shear stress distribution on the control perimeter, depending on the design method, was presented. Experimental and theoretical results were also presented and discussed. It has been shown that in most cases the application of the principles of Eurocode 2 leads to results on the safe side although very conservative. The best agreement with experimental results was obtained by applying the method of reduced control perimeters.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2017, 64, 3/I; 235-245
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sprawdzanie nośności płyt żelbetowych na przebicie według procedury PN-EN 1992-1-1 i Europejskich Aprobat Technicznych
Punching shear design of reinforced concrete slabs according to PN-EN 1992-1-1 and European Technical Approvals
Autorzy:
Urban, Tadeusz
Gołdyn, Michał
Powiązania:
https://bibliotekanauki.pl/articles/973520.pdf
Data publikacji:
2020
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
płyta żelbetowa
nośność na przebicie
obliczenia
zbrojenie poprzeczne
PN-EN 1992-1-1
Eurokod 2
europejska aprobata techniczna
reinforced concrete slab
punching shear
designing
transverse reinforcement
Eurocode 2
European technical approval
Opis:
W artykule omówiono zasady obliczania na przebicie płyt żelbetowych w świetle procedur PN-EN 1992-1-1 oraz Europejskich Aprobat Technicznych (ETA). Przedstawiono różnice w sposobie wymiarowania i rozmieszczania zbrojenia poprzecznego w formie trzpieni dwugłówkowych. Zamieszczono przykłady obliczeniowe, w których rozważano różne położenia słupa (połączenia wewnętrzne, krawędziowe i narożne). W przypadku podpór skrajnych stwierdzono duże zróżnicowanie ilości zbrojenia na przebicie ustalonego według PN-EN 1992-1-1 oraz ETA, co wynika przede wszystkim z odmiennej definicji współczynnika empirycznego, a także różnic w sposobie ustalania naprężeń stycznych na zewnętrznym obwodzie kontrolnym.
In the paper the principles of punching shear design of reinforced concrete slabs in the light of PN-EN 1992-1-1 and European Technical Approvals (ETA) procedures were discussed. Differences in the design and arranging of the punching shear reinforcement in the form of double-headed studs were presented. Working examples were included, in which different position of the column (internal, edge and corner connections) was considered. In the case of outer support zones a large variation in the amount of punching reinforcement calculated according to PN-EN 1992-1-1 and ETA was found, which resulted mainly from the different definition of the empirical coefficient as well as the differences in the method of determining the shear stresses in the outer control perimeter.
Źródło:
Przegląd Budowlany; 2020, 91, 10; 16-29
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies