Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "disinfection by-products" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Oznaczanie bromianów (V) w wodzie przeznaczonej do spożycia metodą chromatografii jonowej z detekcją konduktometryczną
Determination of bromate (V) in drinking water by ion chromatography with conductivity detection
Autorzy:
Kostka, B.
Bebek, M.
Mizerski, W.
Powiązania:
https://bibliotekanauki.pl/articles/2074746.pdf
Data publikacji:
2010
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
chromatografia jonowa
produkty uboczne dezynfekcji
bromiany
wody pitne
ion chromatography
disinfection by-products
bromate
drinking waters
Opis:
Theuseof ionchromatograph ICS-2500 (Dionex, USA) with suppressed conductivity detection and gradient elution for direct determination of bromate in drinking water in presence of chlorite and chlorate is described. In this method, bromate is separated using Dionex IonPac AS19 separation column along with a Dionex IonPac AG19 guard column and generated KOH eluent. Standard solution with certified bromate content and real samples were used in validation process of the method. The method has been proved to be very useful for routine analysis of drinking water because of low limit of detection (0,002 mg/l), good precision (CV < 10%), correctness (relative error < 15%), satisfactory results of interlaboratory comparisons (relative error 12,5%) as well as possibilities of carrying out simultaneous determination of other inorganic oxyhalide disinfection by-products.
Źródło:
Przegląd Geologiczny; 2010, 58, 1; 69-73
0033-2151
Pojawia się w:
Przegląd Geologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Znaczenie procesu dezynfekcji w zapewnieniu bezpieczeństwa mikrobiologicznego wody przeznaczonej do spożycia przez ludzi
Role of disinfection process in ensuring microbiological safety of drinking water
Autorzy:
Dymaczewski, Zbysław
Jeż-Walkowiak, Joanna
Michałkiewicz, Michał
Sozański, Marek
Powiązania:
https://bibliotekanauki.pl/articles/237203.pdf
Data publikacji:
2019
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
water treatment
disinfection
disinfection by-products
biological water stability
monitoring
uzdatnianie wody
dezynfekcja
produkty uboczne dezynfekcji
biologiczna stabilność wody
Opis:
Przedstawiono genezę powstania i tradycję stosowania procesu dezynfekcji w systemach uzdatniania wody. Zwrócono uwagę na złożoność i trudności metodyczne dezynfekcji, zaznaczając, że jest ona jednocześnie podstawowym celem technologii uzdatniania wody, zapewniającym jej bezpieczną jakość mikrobiologiczną. Zaprezentowano nowe podejście do procesu dezynfekcji, wynikające z rozszerzenia funkcji i celów tego procesu, jako podstawy bezpieczeństwa jakości wody przeznaczonej do spożycia. Wykazano, że dezynfekcja powinna być integralnym elementem całego systemu zaopatrzenia w wodę, obejmującego zarówno technologię uzdatniania, jak i układ dystrybucji wody. Podejście takie wynika z miejsca dezynfekcji w systemie, jako ogniwa pośredniego między układem technologicznym a siecią wodociągową. Koncepcja ta zakłada wykorzystanie dezynfekcji również jako procesu monitorującego i diagnozującego bezpieczeństwo całego systemu uzdatniania i dystrybucji wody. Zwrócono też uwagę na zadania badawcze towarzyszące projektowaniu i eksploatacji procesu dezynfekcji, w połączeniu z wiarygodną oceną biologicznej stabilności wody w sieci wodociągowej. Przeanalizowano kryteria metodyczne procesu dezynfekcji, wpływające na wybór chemicznych utleniaczy, ich dawek, czasu kontaktu, miejsc dawkowania, a także identyfikację i ograniczanie powstawania produktów ubocznych.
The paper discusses the origins and tradition of disinfection process application in water treatment systems paying special attention to its complexity and methodological problems. Disinfection was presented as the main objective of water treatment technology that guarantees safe microbiological water quality. A new approach to the process of disinfection was proposed as a result of the expansion of its functions and objectives as a foundation for drinking water quality safety. It was demonstrated that disinfection should become an integral part of the whole water supply system, comprising both water treatment technology and distribution system. Such an approach results from the position of disinfection process in the system, as an indirect link between the technological system and distribution network. The concept also assumes use of disinfection to monitor and diagnose safety of the water supply system as a whole. Attention was also paid to the research tasks accompanying design and operation of the disinfection process in combination with a reliable evaluation of biological water stability in water networks. The article presents the analysis of methodological criteria of the disinfection process affecting chemical oxidant and dose selection, contact time, dosing site location as well as by-product identifi cation and reduction in their formation.
Źródło:
Ochrona Środowiska; 2019, 41, 1; 3-9
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Membranes in water and wastewater disinfection : review
Membrany w dezynfekcji wody i ścieków : przegląd literatury
Autorzy:
Bodzek, Michał
Konieczny, Krystyna
Rajca, Mariola
Powiązania:
https://bibliotekanauki.pl/articles/204688.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
disinfection
disinfection by-products
membrane bioreactors
membrane processes
water
wastewater
dezynfekcja
produkty uboczne dezynfekcji
bioreaktory membranowe
procesy membranowe
woda
ścieki
Opis:
Production of sanitary safe water of high quality with membrane technology is an alternative for conventional disinfection methods, as UF and MF membranes are found to be an effective barrier for pathogenic protozoa cysts, bacteria, and partially, viruses. The application of membranes in water treatment enables the reduction of chlorine consumption during final disinfection, what is especially recommended for long water distribution systems, in which microbiological quality of water needs to be effectively maintained. Membrane filtration, especially ultrafiltration and microfiltration, can be applied to enhance and improve disinfection of water and biologically treated wastewater, as ultrafiltration act as a barrier for viruses, bacteria and protozoa, but microfiltration does not remove viruses. As an example of direct application of UF/MF to wastewater treatment, including disinfection, membrane bioreactors can be mentioned. Additionally, membrane techniques are used in removal of disinfection byproducts from water. For this purpose, high pressure driven membrane processes, i.e. reverse osmosis and nanofiltration are mainly applied, however, in the case of inorganic DBPs, electrodialysis or Donnan dialysis can also be considered.
Filtracja membranowa, szczególnie ultrafiltracja (UF) i mikrofiltracja (MF), może wspomóc i polepszyć proces dezynfekcji wody i ścieków oczyszczonych biologicznie, ponieważ membrana stanowi barierę dla wirusów, bakterii i pierwotniaków. Przykładem bezpośredniego zastosowania membran UF/MF do oczyszczania ścieków, w tym ich dezynfekcji, są bioreaktory membranowe. Techniki membranowe stosuje się ponadto do usuwania ze środowiska wodnego ubocznych produktów dezynfekcji (UPD). Wykorzystuje się tutaj przede wszystkim wysokociśnieniowe procesy membranowe, tj. odwróconą osmozę i nanofiltrację, chociaż w przypadku nieorganicznych UPD brane są również pod uwagę elektrodializa i dializa Donnana.
Źródło:
Archives of Environmental Protection; 2019, 45, 1; 3-18
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena możliwości stosowania promieniowania nadfioletowego w uzdatnianiu wody basenowej – studium przypadku
Assessment of applicability of UV irradiation in swimming pool water treatment – a case study
Autorzy:
Włodyka-Bergier, A.
Bergier, T.
Zając, W.
Powiązania:
https://bibliotekanauki.pl/articles/237754.pdf
Data publikacji:
2017
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
swimming pool water
water treatment
UV irradiation
disinfection by-products
operating costs
woda basenowa
uzdatnianie wody
promieniowanie UV
produkty uboczne dezynfekcji
koszty eksploatacji
Opis:
Influence of UV-chlorination sequence application on swimming pool water quality was investigated. In addition, an analysis of operating costs of such system was conducted. The study was based on a real facility, i.e. the swimming pool of AGH University of Science and Technology in Krakow. In the facility, water disinfection with calcium hypochlorite was carried out, assisted by UV irradiation. Switching the UV lamps temporarily off allowed for comparative studies on the quality of pool water disinfected by pure chlorination and by the UV and chlorination sequence. For these two variants of the swimming pool water disinfection several physico-chemical and microbiological parameters were analyzed, including the disinfection by-products. Cost analysis included the consumption of chemical agents and the UV lamp operation. It was established that the UV technology did not contribute to the expected improvement in the pool water quality in terms of the combined chlorine removal, however it did cause an increase in the concentration of selected organic chlorination by-products. Moreover, application of the UV lamp to the pool water treatment system increased the chlorine demand and, consequently, the consumption of calcium hypochlorite. Combined with the need to exchange lamp fi laments, it raised the operating costs of the pool water treatment technology.
Badano wpływ zastosowania technologii UV w połączeniu z chlorowaniem na jakość wody basenowej, a także przeprowadzono analizę kosztów eksploatacyjnych takiego systemu. Badania przeprowadzono na rzeczywistym obiekcie, jakim jest basen sportowy Akademii Górniczo-Hutniczej w Krakowie. W obiekcie tym dezynfekcja wody jest prowadzona z wykorzystaniem podchlorynu wapnia, a proces ten jest wspomagany naświetlaniem wody promieniami nadfioletowymi (UV). Wyłączenie lamp UV na określony czas pozwoliło na przeprowadzenie badań porównawczych jakości wody basenowej dezynfekowanej tylko chlorem oraz z zastosowaniem układu UV/Cl2. Przeanalizowano szereg wskaźników mikrobiologicznych oraz fizyczno-chemicznych, w tym produktów ubocznych chlorowania, w obu wariantach dezynfekcji wody basenowej. W analizie kosztów uwzględniono zużycie chemikaliów oraz koszty promiennika UV. Stwierdzono, że technologia UV nie spowodowała oczekiwanej poprawy jakości wody basenowej pod względem usuwania chloru związanego, natomiast wpłynęła na zwiększenie ilości niektórych organicznych ubocznych produktów chlorowania. Włączenie lampy UV w system uzdatniania wody basenowej spowodowało również wzrost zapotrzebowania wody na chlor, a w rezultacie większe zużycie podchlorynu wapnia, co w połączeniu z koniecznością wymiany żarników lampy zwiększyło koszty eksploatacyjne technologii uzdatniania wody basenowej.
Źródło:
Ochrona Środowiska; 2017, 39, 1; 53-56
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies