Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "power measurements" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Study on Hybrid Filtering Solution for Marine Electric Network
Autorzy:
Xu, X - Y.
Mindykowski, J.
Chen, C. L. P.
Powiązania:
https://bibliotekanauki.pl/articles/259582.pdf
Data publikacji:
2010
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
electrical engineering
marine vehicle power systems
power system harmonics
power system measurements
quality control
Opis:
This paper presents a Hybrid APF/PFC/PPF Circuit (active power filtering and power factor correction circuit aided by shunt passive filter) for harmonic suppression and power factor correction in a marine electric network. By employing the proposed hybrid circuit, marine electric power network voltage and current can be maintained as being sinusoidal, and the power factor is close to 1. The effectiveness of the proposed method that is applied to a marine electric network is demonstrated through a simulation experiment. The results show that the expected performances are achieved.
Źródło:
Polish Maritime Research; 2010, 2; 72-78
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie modułu FPGA platformy sprzętowej sbRIO-9602 do obliczania fazora z zastosowaniem DFT
The use of FPGA module of sbRIO-9602 system for phasor computation with the use of DFT
Autorzy:
Barczentewicz, S.
Nabielec, J.
Powiązania:
https://bibliotekanauki.pl/articles/151469.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wyznaczanie fazora
FPGA
pomiary w systemie elektroenergetycznym
błędy obliczeniowe
phasor estimation
power system measurements
computational errors
Opis:
Praca dotyczy problemu implementacji algorytmu obliczania fazora w jednym układzie scalonym FPGA-SPARTAN, w którym jednocześnie zaimplementowany jest protokół komunikacyjny czasu rzeczywistego dostosowany do PSS (Power Stabilization System). Przedstawione rozwiązanie pozwala na implementację takich obliczeń z możliwie najmniejszą objętością zajmowanych zasobów FPGA i przy jak najmniejszych błędach obliczeniowych. Algorytm obliczeń oparty został o dyskretne przekształcenie Fouriera.
This work presents a novel approach to implementation of the phasor estimation algorithm using a single FPGA module, with simultaneous communication protocol compatible with Power Stabilization System on it. The presented implementation allows for calculations using as little resources as possible. This paper is organized as follows. In Section 1 the definitions and convention of graphical representation of phasor and synchrophasor (Fig. 1) given by [1] are quoted. Moreover, the definition of discrete Fourier transform is recalled [4], for explanation of its usage in the presented algorithm. In Section 2 the programming environment LabVIEW FPGA and the used instrumentation (sbRIO-9602 platform with FPGA module Xilinx Spartan, ADC converter NI9215E) are described. Furthermore, the proposed algorithm of phasor estimation is presented. Figure 2 shows the simplified block diagram of the designed algorithm. Afterwards, the methodology and results from the conducted tests are listed. Table 1 presents the resources utilization statistics of FPGA, and Table 2 shows the compilation of the test results of computational errors of module and phase estimation. Phasor estimation algorithm is based on DFT computation, and more specifically only one DFT bin is used when sampling frequency and observation length are known. Algorithm uses this fact to minimize demand for FPGA resources. Conducted tests showed that the main problem with obtaining high accuracy of algorithm is limited precision of fixed-point calculations.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 3, 3; 141-143
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wind turbine harmonics caused by unbalanced grid currents
Autorzy:
Dettmann, K. D.
Schostan, S.
Schulz, D.
Powiązania:
https://bibliotekanauki.pl/articles/262590.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
AC machines
circuit analysis
current measurement
harmonic analysis
harmonic distortion
power system harmonics
power system measurements
sequences
wind energy
wind power generation
Opis:
For wind turbines that feed into public grids limits for voltage and current harmonics must be assured. To verify that the actual levels are valid, measurements are necessary. Problems can occur to determine which part of these harmonics has its origin in the wind turbine. It is shown that also harmonics which originally have zero sequences can be transferred over a delta-star-transformer, if the currents of the wind turbine are asymmetric due to unbalanced loads. Measurements in an existing wind turbine configuration are discussed, which confirm the described effects.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2007, 13, 2; 17-23
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies