Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "power-control" wg kryterium: Temat


Wyświetlanie 1-15 z 15
Tytuł:
Simulation of control of lowpower-output steam turbines
Autorzy:
Kryłłowicz, Władysław
Karczewski, Jacek
Szuman, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2091373.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
steam turbine
simulation
power control
Opis:
Problems related to power control of low power-output steam turbines are analyzed. These turbines are designed to operate in distributed power generation systems. Principles of automatic control involving a single control valve are presented on the basis of experience gathered with high power-output turbines. Results of simulations of power control for a low power-output turbine are discussed. It has been proven that closing of the control system and an application of a power controller (of optimally selected parameters) improves the object dynamics (shortening of the transition period). At the same time, a lack of such optimization can results in occurrence of undesirable phenomena such as: overshoot in the generator power characteristics, elongation of the response time to disturbance or overshoot of turbine control valves.
Źródło:
Archives of Thermodynamics; 2022, 43, 2; 3--16
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Shunt power electronic buffer as active filter and energy flow controller
Autorzy:
Szromba, A.
Powiązania:
https://bibliotekanauki.pl/articles/141224.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
active power filter
active current
power control
power quality
Opis:
The considered shunt active power filter can be controlled not only to compensate non-active current in the supply source, but additionally to optimize energy flow between the source and the load. In such a case the filter shapes the source current to be active and simultaneously regulates its magnitude. The presented filter/buffer can operate properly even when the load contains AC or DC variable energy source of any characteristic. The device can optimize energy flow for a single load, but also for a group of loads as well. The distinctive feature of the employed control method of the filter/buffer is that certain changes of energy stored in the device are utilized as the source of information concerning the active current of the load. This control method is very flexible and can be implemented to nearly all structures of active filters, for DC, single- and multiphase circuits.
Źródło:
Archives of Electrical Engineering; 2013, 62, 1; 55-75
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Power electronic systems as a crucial part of Smart Grid infrastructure - a survey
Autorzy:
Benysek, G.
Kaźmierkowski, M.
Popczyk, J.
Strzelecki, R.
Powiązania:
https://bibliotekanauki.pl/articles/200105.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power electronics
smart grid
converter
power control
power conditioning
Opis:
This article gives a tutorial overview of the most important issues related to the use of power electronic systems in power engineering, with respect to the urgent need for modernization of existing grids in the direction of intelligent networks. The main problems and conditions bound up with the construction of Smart Grids and the location, as well as functioning in them of the most important power electronic systems are presented here. Special attention is directed therein to the potential possibilities of so-called ‘smart’ transformers and V2G and V2H technologies.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2011, 59, 4; 455-473
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An optimization model for reactive power control of super high voltage grid systems
Autorzy:
Shaban, M. A.
Powiązania:
https://bibliotekanauki.pl/articles/377699.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
MVAR
super high voltage grid systems
power control
voltage control
reactive power
Opis:
This paper develops an optimization model to control the excessive (MVAR) generation by super high voltage gird systems for maintaining the nodal voltages within the required acceptable margin. The model enhances an approximate solution on the condition of balanced real power. The pseudo-inverse method of optimization is implemented as an optimal optimization is implemented as an optimal means of solving non-square systems of equations based on LaGrange's theory of optimization. It recommends the locations and ratings of the minimum required reactors from the preinstalled ones that to be in service for optimum nodal reactive power and voltage controls.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2012, 69; 89-93
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Control of a doubly fed induction generator at grid voltage imbalance
Autorzy:
Łuszczyk, T.
Iwański, G.
Powiązania:
https://bibliotekanauki.pl/articles/1193415.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
doubly fed induction generator
power control
torque control
unbalanced grid
Opis:
Properties and control of a doubly fed induction machine operating under unbalanced grid voltage conditions have been presented. The proposed method does not include symmetrical sequences decomposition and is realized in a rotating frame not synchronized either with the grid voltage vector or with the stator flux vector. The method uses a reference torque and the reference q component of instantaneous power for calculation of the reference stator current. Next, calculation of magnetizing current for a given unbalanced grid voltage is used to assign the reference rotor current. Due to the fact that the reference current contains both a positive and a negative sequence, a proportional-integral-resonant controller is used. The main control target is the non-oscillatory waveform of torque, whereas other separate strategies like symmetrical stator current or sinusoidal rotor current can be easily obtained by adequate filtration of the reference control signals of the stator or rotor currents, respectively. The simulation results of the 2 MW model have been presented for a doubly fed induction generator as well as the results of laboratory tests with the use of a small scale 7.5 kW machine.
Źródło:
Power Electronics and Drives; 2017, 2, 37/2; 31-48
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
State observer for doubly-fed induction generator
Autorzy:
Blecharz, K.
Wachowiak, D.
Krzemiński, Z.
Powiązania:
https://bibliotekanauki.pl/articles/1193442.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
doubly-fed induction generator
non-linear control
state observer
power control
Opis:
The purpose of this paper is to show a new state observer for doubly-fed generator. A proposed z-type observer algorithm based on mathematical model of doubly fed generator with additional variables treated as a disturbances has been used. A nonlinear multiscalar control method has been proposed to control active and reactive power of the generator. All analyses were verified by simulations and experiments tests.
Źródło:
Power Electronics and Drives; 2017, 2, 37/2; 61-75
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Location-based Power Control Mechanism for D2D Communication Underlaying a Cellular System
Autorzy:
Rodziewicz, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/24200756.pdf
Data publikacji:
2023
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
context-awareness
device-to-device
frequency reuse-1
power control
Opis:
The paper presents a location-based approach to controlling the power of device-to-device (D2D) underlay of a frequency reuse-1 cellular system. The system allows for direct communication to share uplink resources with cellular users. As a result, both D2D and cellular users are experiencing additional interferences in the system. By controlling the output power of the devices, these interferences can be mitigated and the performance of the network can be improved in terms of better spectral and energy efficiency. The proposed location-based target signal-to-interference ratio power control scheme for D2D communications utilizes information about users' locations to estimate the interference level experienced by the receiver of the direct link. Based on this estimation, an appropriate transmit power can be determined. The performance of the proposed power control solution is investigated via system level simulations.
Źródło:
Journal of Telecommunications and Information Technology; 2023, 3; 49--53
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Interference Management using Power Control for Device-to-Device Communication in Future Cellular Network
Autorzy:
Nugraha, T. A.
Pamungkas, M. P.
Chamim, A. N. N.
Powiązania:
https://bibliotekanauki.pl/articles/958069.pdf
Data publikacji:
2018
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
cellular network
device-to-device communication
interference management
power control
Opis:
There are many scenarios that have been proposed for fifth generation (5G) networks. Some of them, if implemented, will bring fundamental changes at the architectural and node level. One example of such proposed technologies is device-to-device (D2D) communications which will change the nature of conventional cellular network design. D2D permits direct communication between two or more user devices without intervention of the base station (i.e. eNB). D2D can ensure network performance improvement over the traditional cellular network, because it can offload the mobile data traffic from the other devices. However, applying D2D features in a cellular network will bring about more complex interference problems, since D2D communication uses the same band as its underlying cellular communication network. The aim of this research is to investigate interference-related problems caused by D2D communications, affecting the underlying cellular networks, during downlink and uplink transmissions. The paper examines the use of power control methods to mitigate interference. A comparison is offered between fixed power level (FC) with or without power control, and adaptive power controls using two methods (AC1 and AC2), on a base station or on each of the D2D devices, based on the measured signal to interference plus noise ratio (SINR). The simulation results show that both power control methods contribute to improvement of network performance. AC1 and AC2 can improve SINR by about 1 dB and 0.5 dB compared to FC in a downlink transmission, and by 0.5 dB in an uplink transmission.
Źródło:
Journal of Telecommunications and Information Technology; 2018, 3; 31-36
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Linear quadratic power control for CDMA systems
Autorzy:
Anderson, M.D.
Perreau, S.
White, L.B.
Powiązania:
https://bibliotekanauki.pl/articles/307733.pdf
Data publikacji:
2003
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
CDMA
CDMA systems
power control
Kalman filtering
channel estimation
linear quadratic control systems
Opis:
In this paper, we present a robust decentralized method for jointly performing channel estimation and closed loop power control for the reverse link of CDMA networks. Our method, based on linear quadratic Gaussian (LQG) control systems theory and Kalman filtering, does not require any training symbols for channel or signal to interference ratio (SIR) estimation. The main interest of this new scheme is that it improves the performance of current SIR based power control techniques while avoiding the problem of power escalation, which is often observed in current systems.
Źródło:
Journal of Telecommunications and Information Technology; 2003, 2; 48-54
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative Analysis of Procedures and Solutions to Improve Energy Efficiency of Massive MIMO
Autorzy:
Phogat, Ritu Singh
Joshi, Rutvij
Powiązania:
https://bibliotekanauki.pl/articles/2200684.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
EE
Uplink-Downlink Transmission
power control
linear precoding
CF Massive MIMO
Opis:
The blustery growth of high data rate applications leads to more energy consumption in wireless networks to satisfy service quality. Therefore, energy-efficient communications have been paid more attention to limited energy resources and environmentally friendly transmission functioning. Countless publications are present in this domain which focuses on intensifying network energy efficiency for uplink-downlink transmission. It is done either by using linear precoding schemes, by amending the number of antennas per BS, by power control problem formulation, antenna selection schemes, level of hardware impairments, and by considering cell-free (CF) Massive-MIMO. After reviewing these techniques, still there are many barriers to implement them practically. The strategies mentioned in this review show the performance of EE under the schemes as raised above. The chief contribution of this work is the comparative study of how Massive MIMO EE performs under the background of different methods and architectures and the solutions to few problem formulations that affect the EE of network systems. This study will help choose the best criteria to improve EE of Massive MIMO while formulating a newer edition of testing standards. This survey provides the base for interested readers in energy efficient Massive MIMO.
Źródło:
International Journal of Electronics and Telecommunications; 2022, 68, 4; 677--686
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model predictive direct power control of energy storage quasi-Z-source grid-connected inverter
Autorzy:
Tang, Min'an
Yang, Shangmei
Zhang, Kaiyue
Wang, Qianqian
Liu, Chenggang
Dong, Xuewang
Powiązania:
https://bibliotekanauki.pl/articles/2042769.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
quasi Z-Source
inverter
energy storage
power control
model predictive
space vector
Opis:
In order to overcome the shortcoming of large switching losses caused by variable switching frequency appears in the conventional finite control set model predictive control (FCS-MPC) algorithm, a model predictive direct power control (MP-DPC) for an energy storage quasi-Z-source inverter (ES-qZSI) is proposed. Firstly, the power prediction model of the ES-qZSI is established based on the instantaneous power theory. Then the average voltage vector in the coordinate system is optimized by the power cost function. Finally, the average voltage vector is used as the modulation signal, and the corresponding switching signal with fixed frequency is generated by the shoot-through segment space vector pulse width modulation (SVPWM) technology. The simulation results show that the ES-qZSI realizes six shoot-through actions per control cycle and achieves the constant frequency control of the system, which verifies the correctness of the proposed control strategy.
Źródło:
Archives of Electrical Engineering; 2022, 71, 1; 21-35
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Conceptual Introduction to Smooth Control of Active Power for Thermal Power Units Operating in National Power System
Koncepcja łagodnej regulacji mocy czynnej bloków cieplnych w Krajowym Systemie Elektroenergetycznym
Autorzy:
Lipiński, M.
Fennig, W.
Mączka, T.
Ziaja, E.
Powiązania:
https://bibliotekanauki.pl/articles/952898.pdf
Data publikacji:
2018
Wydawca:
ENERGA
Tematy:
system elektroenergetyczny
regulacja mocy
regulacja częstotliwości
łagodna regulacja
wiodący kocioł
wiodąca turbina
power system
power control
power frequency
smooth control
boiler follow
turbine follow
Opis:
Opisano powszechnie stosowane tryby pracy bloków cieplnych („prowadzący kocioł” i „prowadząca turbina”) wykorzystywane do automatycznej regulacji mocy czynnej w elektrowniach pracujących w KSE. Omówiono zarówno wady, jak i zalety obu trybów pracy. Przedstawiono nowatorską koncepcję tzw. łagodnej regulacji mocy czynnej, opartą na tworzeniu w czasie rzeczywistym grupy złożonej z kilku bloków pracujących jako całość (wieloblok) w omówionych trybach pracy, z przewagą trybu wiodący kocioł. Jak wykazały prace wstępne i symulacje, przedstawione nowatorskie podejście do regulacji grupą bloków (pracującą na wspólne szyny) spełnia wymagania dotyczące dokładności regulacji mocy czynnej wymaganej przez operatora systemu przesyłowego (Polskie Sieci Energetyczne – PSE). Ponadto wykonane analizy i symulacje wskazują, że zastosowanie tej regulacji pozwoli na ograniczenie negatywnych skutków występujących przy obecnie stosowanej regulacji indywidualnej dla każdego bloku (bloki pracują indywidualnie w trybie „prowadzącej turbiny”). Proponowane rozwiązanie ograniczy liczbę wymaganych procesów regulacji i zlikwiduje znaczną część zakłóceń bloku, nie przenosząc ich do systemu elektroenergetycznego. Wprowadzenie proponowanego rozwiązania będzie skutkować ograniczeniem ilości spalanego paliwa, zmniejszeniem emisji szkodliwych gazów i pyłów oraz wydłużeniem czasu eksploatacji urządzeń cieplnych i ciśnieniowych bloków.
This paper describes the control modes (boiler follow and turbine follow) commonly used in the operation of thermal power units for automatic active power control of power plants in the Polish National Power System. The benefits and disadvantages of both control modes are discussed. A novel concept is presented for a so-called smooth control of active power, which is based on real-time grouping of several power units to operate as one (in the so-called substitute unit) in both control modes discussed here and with boiler follow as the predominant mode. As demonstrated by initial research and simulation, this novel approach to power unit group control (operated to one bus bar) meets the accuracy of active power control specified by the Transmission System Operator (TSO). The completed simulations and studies also reveal that application of smooth active power control will help reduce the negative effects present in currently applied individual power unit control (with each power unit operated independently in turbine follow). The novel concept will also reduce the number of control processes and eliminate a considerable part of internal disturbances of the substitute unit is eliminated so they will not be transferred to the power system. Furthermore, implementation of the novel concept can help reduce fuel combustion, meet the environmental protection targets by reducing harmful gas and particulate emissions, and extend the operating life of power unit thermal and pressure equipment.
Źródło:
Acta Energetica; 2018, 3; 15-25
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dinamika mnogocilindrovykh dizelnykh dvigatelejj s regulirovaniem moshhnosti otkljucheniem cilindrov i ciklov
Dynamics of multicylinder diesel engines with power control by deactivation of cylinders and cycles
Autorzy:
Beshun, A.
Powiązania:
https://bibliotekanauki.pl/articles/76583.pdf
Data publikacji:
2014
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
internal combustion engine
combustion engine
diesel engine
power control
deactivation process
cylinder
algorithm
dynamic parameter
rotation
crankshaft
Źródło:
Motrol. Motoryzacja i Energetyka Rolnictwa; 2014, 16, 3
1730-8658
Pojawia się w:
Motrol. Motoryzacja i Energetyka Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka torów pomiarowych i urządzenia wykonawczego w układzie regulacji turbiny kondensacyjnej
Diagnostic of measuring tracks and executive device in control system for condensing turbine
Autorzy:
Pawlak, M.
Powiązania:
https://bibliotekanauki.pl/articles/155014.pdf
Data publikacji:
2006
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
układ regulacji
modelowanie rozmyte
sieci neuronowe
diagnostyka
tory pomiarowe
elementy wykonawcze
fault diagnosis
power control
power generation
turbines
fuzzy modeling
fault tolerant systems
Opis:
Przedstawiono układ regulacji turbiny kondensacyjnej odporny na uszkodzenia torów pomiarowych. Opisano działania układu regulacji turbiny kondensacyjnej pracującej w układzie blokowym. Zaprezentowano charakterystykę sygnałów wchodzących do regulatora i metody wykrywania uszkodzeń dla danego toru pomiarowego. Opisano zasadę działania i system diagnostyki dla urządzenia wykonawczego
In this paper described fault tolerant system of regulation of condensing turbine on damages of measuring - tracks. One presented characterization of signals entering to controler and methods of detecting of damages measuring - track and executive device.
Źródło:
Pomiary Automatyka Kontrola; 2006, R. 52, nr 11, 11; 48-50
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Układ sterowania małą elektrownią wiatrową z generatorem asynchronicznym
Control a small wind turbine with asynchronous generator
Autorzy:
Możdżyński, K.
Gajowik, T.
Rafał, K.
Malinowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/408501.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
odnawialne źródła energii
sterowanie mocą
przekształtnik AC-DC-AC
generator indukcyjny
elektrownia wiatrowa
renewable energy sources
power control
AC-DC-AC power converter
induction generator
wind energy generation
Opis:
Artykuł przedstawia układ sterowania elektrownią wiatrową z generatorem asynchronicznym klatkowym o mocy 11 kW. Generator asynchroniczny w porównaniu do generatora synchronicznego cechuje niższy koszt i większa niezawodność, jednak ze względu na zjawiska związane ze wzbudzeniem, konieczne jest stosowanie bardziej złożonego układu przekształtnikowego oraz dodatkowej aparatury wspomagającej działanie elektrowni wiatrowej w rzeczywistych warunkach. W rezultacie układ sterowania przekształtnika energoelektronicznego sprzęgającego generator z siecią energetyczną wymaga dodatkowego rozbudowania o możliwość zarządzania całą elektrownią. W artykule omówiono zagadnienia i wyniki eksperymentalne związane ze stanami pracy systemu małej elektrowni wiatrowej oraz pętlami sterowania procesem przetwarzania mocy.
The article presents the control system wind turbine with asynchronous squirrel cage generator with a capacity of 11 kW. Asynchronous generator compared to the synchronous generator characterized by a lower cost and higher reliability, but because of the phenomena associated with excitation, it is necessary to use a more complex system of the converter and an additional devices supporting the operation of the wind power plant under realistic conditions. As a result, control of the power electronic inverter coupling generator with power grid requires additional expand on the ability to manage the entire power plant. The article discusses the issues and experimental results related to the states of the system of small wind power plant and process control loops of power processing.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2017, 7, 4; 82-87
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-15 z 15

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies