Tytuł:
Power electronic systems as a crucial part of Smart Grid infrastructure - a survey
Autorzy:
Benysek, G.
Kaźmierkowski, M.
Popczyk, J.
Strzelecki, R.
Powiązania:
https://bibliotekanauki.pl/articles/200105.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power electronics
smart grid
converter
power control
power conditioning
Opis:
This article gives a tutorial overview of the most important issues related to the use of power electronic systems in power engineering, with respect to the urgent need for modernization of existing grids in the direction of intelligent networks. The main problems and conditions bound up with the construction of Smart Grids and the location, as well as functioning in them of the most important power electronic systems are presented here. Special attention is directed therein to the potential possibilities of so-called ‘smart’ transformers and V2G and V2H technologies.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2011, 59, 4; 455-473
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A robust 18-pulse diode rectifier with coupled reactors
Autorzy:
Mysiak, P.
Strzelecki, R.
Powiązania:
https://bibliotekanauki.pl/articles/200065.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
series active power filters
multi-pulse rectifiers
coupled reactors
power conditioning
Opis:
The article presents the principle of operation and selected results of simulation and laboratory tests of the 18-pulse rectifier system with coupled reactors and small series active power filter. The presented system makes it possible to reduce, especially in distribution supply networks, undesired higher current harmonics. The 18-pulse nature of operation of the rectifier is reached using a set of coupled three-phase network reactors (CDT and CTR). The simultaneous use of the coupled reactors and the small active power filter provides opportunities for reduction of the supply current distortion, especially in case of voltage harmonic distortion and voltage unbalance.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2011, 59, 4; 541-550
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A multi-pulse diode rectifier with a coupled three-phase reactor - the design method and results of the simulation and laboratory tests
Autorzy:
Mysiak, P.
Jankowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/262693.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
power conditioning
multi-pulse power network converters
coupled three-phase power network reactors
Opis:
The article presents the principle of operation, design method, and results of laboratory and simulation tests of a 24-pulse power network converter system with direct-voltage output, the concept and practical realisation of which was worked out within the framework of a research project financed by the State Committee for Scientific Research. The presented converter allows significant reduction of undesirable higher harmonics in the power network current, including the elimination of harmonics of an order 23 and 25. The 24-pulse nature of operation of the system is obtained using three sets of coupled three-phase power network reactors (CTR).
Źródło:
Electrical Power Quality and Utilisation. Journal; 2005, 11, 1; 83-92
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Precyzyjna kompensacja zniekształceń harmonicznych prądu przez równoległy filtr aktywny
The precise compensation of grid current distortion by shunt active power filters
Autorzy:
Cichowski, A.
Śleszyński, W.
Powiązania:
https://bibliotekanauki.pl/articles/268510.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przetwarzanie mocy
filtr aktywny
kompensacja efektu czasu martwego
power conditioning
shunt active power filter
dead time compensation
Opis:
W artykule zaprezentowano cztery źródła niedokładnej kompensacji harmonicznych prądu przez filtr aktywny. Są nimi: niedokładna synchronizacja z napięciem sieci zasilającej, opóźnienia wprowadzane w układzie sterującym, fluktuacje napięcia w obwodzie pośredniczącym oraz zniekształcenia napięć generowanych przez przekształtnik energoelektroniczny spowodowane głównie czasem martwym. W artykule przedstawiono wpływ zaproponowanych udoskonaleń algorytmu sterowania równoległym filtrem aktywnym na ograniczanie zniekształceń prądów sieciowych. Wszechstronne podejście do algorytmu sterowania równoległym filtrem aktywnym pozwoliło uzyskać unikalnie niską zawartość zniekształceń harmonicznych prądów pobieranych z sieci elektroenergetycznej.
This paper addresses the main sources of grid current distortion in shunt active power filter applications and proposes efficient solutions to selected problems. This sources are: imperfect grid synchronization caused by the distortion in the grid voltages, time delays in the evaluation of grid voltages and computation of compensating currents, fluctuations of the dc bus voltage, and the distortion of inverter output voltages due to dead-time effects and related factors. The focus of the paper is on the assessment of the significance of the proposed improvements in the control algorithm for the reduction of harmonic distortion of grid currents. Experimental results show that in the investigated control system the most important algorithms are those concerning dead time compensation, load current prediction, suppression of dc voltage related distortions in reference currents and synchronization with the grid voltage. On the other hand less important variants are with a secondorder Butterworth filter instead of the moving average and predictive current controller without voltage prediction. Comprehensive approach to the compensation of grid current distortion in shunt active power filter systems allowed to obtain an exceptionally low THD (0,23 % for high currents).
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 47; 27-30
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Current harmonic controller in multiple reference frames for series active power filter integrated with 18-pulse diode rectifier
Autorzy:
Śleszyński, W.
Cichowski, A.
Mysiak, P.
Powiązania:
https://bibliotekanauki.pl/articles/200591.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
series active power filters
multi-pulse converters
diode rectifier
power conditioning
konwerter
prostownik diodowy
kondycjonowanie mocy
aktywne filtry mocy
Opis:
The paper presents the control system and selected results of experimental tests of the AC/DC power converter consisting of an 18pulse diode rectifier based on coupled reactors and a serial active power filter. Proportional integral controllers with decoupling components are implemented in multiple reference frames for selective line current harmonic suppression. The regulator is provided with a backtracking anti-windup mechanism of sorts in which a signal proportional to the saturated control reference is subtracted from the error signal in each reference frame. The fundamental harmonic filter based on the DFT algorithm with phase correction is used for grid synchronization and current harmonic detection. Three configurations of the 15 kVA converter were tested experimentally and then compared: the 18-pulse diode rectifier with and without an additional grid reactor, and the rectifier integrated with an active power filter. The applied control method of active filter significantly reduces harmonic distortion and unbalance of the grid current, which is particularly advantageous under non-ideal supply voltage and low loads conditions.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2018, 66, 5; 699-704
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A diode rectifier with coupled reactor and small shunt power filter
Prostownik diodowy z dławikami sprzężnymi i małym równoległym filtrem aktywnym
Autorzy:
Mysiak, P.
Grugel, P.
Powiązania:
https://bibliotekanauki.pl/articles/194114.pdf
Data publikacji:
2011
Wydawca:
Politechnika Bydgoska im. Jana i Jędrzeja Śniadeckich. Wydawnictwo PB
Tematy:
energetyczne filtry aktywne
sieciowe trójfazowe dławiki sprzężone
wielopulsowy przekształtnik sieciowy
kondycjonowanie energii
active power filters
coupled three-phase power network reactors
local power network
multi-pulse grid converters
power conditioning
Opis:
The article describes the laboratory and simulation tests of 12- and 24- pulse power grid converter systems with DC voltage output that work together with shunt active power filter (APF). It presents both the operations' principles and the results of these tests. The systems under discussion make it possible to reduce the number of unwanted higher harmonics in the power network current. Moreover, they can also help eliminate the 23- and 25-order harmonics especially in the conditions of local power network supply. In order to obtain the multipulsed system's operation, a set of coupled three-phase power network reactors (CTR) has been used.
Artykuł zawiera wyniki badań symulacyjnych i testów laboratoryjnych 12- i 24- pulsowego przekształtnika sieciowego z wyjściowym obwodem napięcia stałego, pracującego z równoległym filtrem aktywnym. Omówione rozwiązanie pozwala znacząco zredukować występowanie niepożądanych harmonicznych prądu sieci, tym całkowicie wyeliminować harmoniczne rzędu 23 i 25. Wielopulsowa praca układu została osiągnięta poprzez zastosowanie zespołu trójfazowych dławików sprzężonych.
Źródło:
Zeszyty Naukowe. Elektrotechnika / Uniwersytet Technologiczno-Przyrodniczy w Bydgoszczy; 2011, 16; 5-16
0209-0570
Pojawia się w:
Zeszyty Naukowe. Elektrotechnika / Uniwersytet Technologiczno-Przyrodniczy w Bydgoszczy
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies