Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "polypropylene fiber" wg kryterium: Wszystkie pola


Wyświetlanie 1-14 z 14
Tytuł:
Effect of polypropylene fiber addition on mechanical properties of concrete based on portland cement
Autorzy:
Małek, M.
Życiński, W.
Jackowski, M.
Wachowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/298035.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie
Tematy:
polypropylene fibre
mechanical properties
concrete
Portland cement
Opis:
In this work results of poly(propylene) fibers (PP), from recycling process, added into concrete mixture based on portland cement was characterized. The main purpose of this research was to identify direct influence of the fibers addition on the concrete mechanical strength. The recipe of the concrete was prepared using three types of aggregates with different grain size: 0.125–0.250, 0.250–0.500 and 0.500–1.000 mm, deflocculant based on polycarboxylates, water and portland cement (42.5 MPa). To identify structures of the researched samples and fibers light microscopy (LM) observation was performed. Basic properties of concrete mixture were defined by slump cone test and setting time. Mechanical properties such as compressive strength and bending test after 1, 7, 14 and 28 days were characterized. Obtained results were compared with mixtures without fibers modifications. Study was proven that all chosen fibers from recycled origin revealed increased effect on final mechanical properties of concrete and are very perspective for future application in concrete technology.
Źródło:
Technical Sciences / University of Warmia and Mazury in Olsztyn; 2018, 21(3); 207-214
1505-4675
2083-4527
Pojawia się w:
Technical Sciences / University of Warmia and Mazury in Olsztyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of randomly distributed polypropylene fiber reinforcement on the shear behavior of sandy soil
Autorzy:
Benziane, Mehdi Missoum
Della, Noureddine
Denine, Sidali
Sert, Sedat
Nouri, Said
Powiązania:
https://bibliotekanauki.pl/articles/178213.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
sand
direct shear box tests
polypropylene fibre
shear strength
normal stress
relative density
Opis:
The inclusions of geosynthetic materials (fibers, geomembranes and geotextiles) is a new improvement technique that ensures uniformity in the soil during construction. The use of tension resisting discreet inclusions like polypropylene fibers has attracted a significant amount of attention these past years in the improvement of soil performance in a cost-efficient manner. A series of direct shear box tests were conducted on unreinforced and reinforced Chlef sand with different contents of fibers (0, 0.25, 0.5 and0.75%) in order to study the mechanical behavior of sand reinforced with polypropylene fibers. Samples were prepared at three different relative densities 30%, 50% and 80% representing loose, medium dense and dense states, respectively, and performed at normal stresses of 50, 100 and 200 kPa. The experimental results show that the mechanical characteristics are improved with the addition of polypropylene fibers. The inclusion of randomly distributed fibers has a significant effect on the shear strength and dilation of sandy soil. The increase in strength is a function of fiber content, where it has been shown that the mechanical characteristics improve with the increase in fiber content up to 0.75%, this improvement is more significant at a higher normal stress and relative density.
Źródło:
Studia Geotechnica et Mechanica; 2019, 41, 3; 151-159
0137-6365
2083-831X
Pojawia się w:
Studia Geotechnica et Mechanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of hybrid steel-polypropylene fiber on punching shear behavior of flat slab with an opening
Autorzy:
Zaezue, Shahzinan J.
Hadi, Waleed K.
Powiązania:
https://bibliotekanauki.pl/articles/36060590.pdf
Data publikacji:
2023
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
hybrid fiber
steel fiber
polypropylene fibre
punching shear
slab with opening
Opis:
This research aimed to gain a better understanding of how the addition of fiber influences the punching shear capacity of two-way slabs by conducting an experiment into the structural behavior of flat slabs with and without a square opening using different volume fractions of hybrid steel-polypropylene fiber (0%, 0.9%, 1.05% and 1.8%). Ten 700 × 700 × 70 mm slabs were divided into five pairs, with two samples used as control samples (with and without openings), and eight other samples with different volume fraction of fibers. Results showed that an increase in fiber content enhanced the shear strength of the slabs. For example, as the volume fraction of hybrid fiber increased from 0.0 to 1.8%, the ultimate load increased by 52% for slabs without an opening and up to 42% for slabs with an opening.
Źródło:
Scientific Review Engineering and Environmental Sciences; 2023, 32, 1; 3-17
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative study on durability properties of engineered cementitious composites with polypropylene fiber and glass fiber
Badanie porównawcze właściwości wytrzymałościowych inżynieryjnych kompozytów cementowych z włóknem propylenowym i włóknem szklanym
Autorzy:
Ranjith, S.
Venkatasubramani, R.
Sreevidya, V.
Powiązania:
https://bibliotekanauki.pl/articles/962321.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kompozyt cementowy
ECC
włókno polipropylenowe
włókno szklane
wytrzymałość
popiół lotny
beton
zaprawa cementowa
engineered cementitious composites
polypropylene fibre
glass fiber
durability
fly ash
concrete
cement mortar
Opis:
The durability characteristics of Engineered Cementitious Composites (ECC) with various fibers such as polypropylene and glass were investigated in view of developing composites with high resistance to cracking. ECC offer large potential for durable civil infrastructure due to their high tensile strain capacity and controlled micro-crack width. In this study, fibre volume fractions (0.5%, 1%, 1.5%, and 2%) of both polypropylene and glass fibers varied and durability measures such as a rapid chloride penetration test, sorptivity, water absorption, acid attack, and sulphate attack were measured. Increasing the fiber content up to 1.5% improved the durability properties of ECC. The test results indicate that the glass fiber-reinforced Engineered Cementitious Composites have better durability characteristics than polypropylene fiber-reinforced ECC.
Beton jest jednym z najważniejszych materiałów stosowanych w budownictwie. Zaletą stosowania betonu jest to, że można go formować w dowolnym kształcie i rozmiarze. Ze względu na kruchość betonu, posiada on szerokie właściwości ściskające i słabe napięcie. Kruchość betonu rośnie wraz ze wzrostem zawartości gruboziarnistego kruszywa. Wysoka kruchość betonu może prowadzić do powstawania pęknięć, jeśli beton posiada duże naprężenie. Aby przezwyciężyć ten problem i nadać betonowi wytrzymałość na rozciąganie, podjęto próbę wytworzenia betonu o dużej wytrzymałości na rozciąganie – opracowano mieszankę o nazwie ECC. ECC jest kompozytem wzmocnionym włóknami o wysokiej wytrzymałości na rozciąganie, wysokiej wydajności i średniej zawartości włókien. W porównaniu do 0,1% standardowego betonu, ECC posiada wytrzymałość na rozciąganie w zakresie 3-5%. Powszechnie wiadomo, że dodanie włókien do kompozytów prowadzi do poprawy właściwości mechanicznych. Celem niniejszego badania jest dokonanie oceny właściwości wytrzymałościowych ECC i opracowanie nowej klasy ECC, które posiadają wysoką odporność na pękanie. Początkowo, mieszanka ECC M45 opisana w istniejących zbiorach literackich była traktowana jako podstawa do celów badawczych. Opracowano osiem mieszanek ECC, wytworzonych w procesie monolitycznego dodawania włókna polipropylenowego i włókna szklanego do podstawowej mieszanki w różnych proporcjach frakcji, takich jak 0,5%, 1%, 1,5% i 2% w stosunku do objętości ECC; ponadto przygotowano jedną konwencjonalną mieszankę bez żadnych dodatków włóknistych. Po opracowaniu próbnych mieszanek, stosunek wody do cementu został określony jako wartość 0,54. Dawka superplastyfikatora w ilości 1,3% wagi cementu określonego w teście Marshala została dodana do mieszanki. Wyniki bezpośredniego badania wytrzymałości na ściskanie, przeprowadzonego na próbkach mieszanek ECC, były o 4,2% wyższe niż w przypadku konwencjonalnej mieszanki zapraw. Badanie wytrzymałości na ściskanie zostało przeprowadzone na próbce ECC o wymiarach 70,6 mm oraz na zaprawie cementowej, według IS: 4031-1988 (część 6). Badania wytrzymałościowe, obejmujące działanie siarczanu, działanie kwasu, badanie szybkiego przenikania chlorków, badanie sorpcyjne oraz badania wchłaniania wody zostały przeprowadzone na obu próbkach ECC i konwencjonalnej zaprawy. Wytrzymałość na ściskanie ECC wzrasta aż do 1,5% zawartości włókien w próbce ECC, a następnie maleje. Wytrzymałość na ściskanie ECC wzmocnionego włóknami szklanymi z 1,5% zawartości włókien jest wyższa niż w przypadku wszystkich innych mieszanek. W badaniu działania siarczanu, 90-dniowa wytrzymałość na ściskanie 1,5% próbki ECC wzmocnionej włóknami szklanymi była o 8,2% większa w porównaniu do 1,5% próbki ECC wzmocnionej włóknami polipropylenowymi i o 34% większa w porównaniu do próbki zaprawy. Utrata masy i wytrzymałości na ściskanie w przypadku 1,5% ECC wzmocnionej włóknami szklanymi była mniejsza niż w innych mieszankach poddanych 90-dniowemu działaniu siarczanów i kwasów. 1,5% próbka ECC wzmocniona włóknami szklanymi wchłonęła mniejszą ilość wody w porównaniu z innymi proporcjami mieszanki. Wyniki badania sorpcyjnego jasno pokazują, że 1,5% próbka ECC wzmocniona włóknami polipropylenowymi i 1,5% próbka ECC wzmocniona włóknami szklanymi miały mniej porów w porównaniu do innych mieszanek. Odporność na przepuszczalność chlorków była wyższa w przypadku mieszanki z 1,5% zawartością włókien, w porównaniu do innych mieszanek. Jednakże, ECC zawierająca 1,5% włókien szklanych wykazuje lepsze właściwości wytrzymałościowe niż wszystkie inne mieszanki. W niniejszym badaniu opracowano nową klasę ECC poprzez dodanie 1,5% zawartości włókien szklanych do ECC, która posiada większą odporność na pęknięcia oraz większą wytrzymałość.
Źródło:
Archives of Civil Engineering; 2017, 63, 4; 83-101
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Load-deflection characteristics of steel, polypropylene and hybrid fiber reinforced concrete beams
Autorzy:
Tamil Selvi, M.
Thandavamoorthy, T. S.
Powiązania:
https://bibliotekanauki.pl/articles/230679.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
włókno stalowe
włókno polipropylenowe
moduł sprężystości
obciążenie
krzywa ugięcia
sztywność
steel fiber
polypropylene fibre
elasticity modulus
load
deflection curve
stiffness
Opis:
Concrete is the most widely used construction material because of its specialty of being cast into any desired shape. The main requirements of earthquake resistant structures are good ductility and energy absorption capacity. Fiber reinforced concrete possesses high flexural and tensile strength, improved ductility, and high energy absorption over the conventional concrete in sustaining dynamic loads. The aim of this paper is to compare the properties of concrete beams in which three types of fibers are added individually. Steel fibers, polypropylene fibers and hybrid fibers were added to concrete in the weight ratio of four percentages in the preparation of four beam specimens. The fourth specimen did not contain fibers and acted as a control specimen. The dimensions of the beam specimens were 150 mm × 150 mm × 700 mm. The reinforced concrete beams of M30 grade concrete were prepared for casting and testing. Various parameters such as load carrying capacity, stiffness degradation, ductility characteristics and energy absorption capacity of FRC beams were compared with that of RC beams. The companion specimens were cast and tested to study strength properties and then the results were compared. All the beams were tested under three point bending under Universal Testing Machine (UTM). The results were evaluated with respect to modulus of elasticity, first crack load, ultimate load, and ultimate deflection. The test result shows that use of hybrid fiber improves the flexural performance of the reinforced concrete beams. The flexural behavior and stiffness of the tested beams were calculated, and compared with respect to their load carrying capacities. Comparison was also made with theoretical calculations in order to determine the load-deflection curves of the tested beams. Results of the experimental programme were compared with theoretical predictions. Based on the results of the experimental programme, it can be concluded that the addition of steel, polypropylene and hybrid fibers by 4% by weight of cement (but 2.14 % by volume of cement) had the best effect on the stiffness and energy absorption capacity of the beams.
Źródło:
Archives of Civil Engineering; 2015, 61, 1; 59-72
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of elevated temperature on the properties of concretes reinforced with Alfa fiber
Autorzy:
Mihoub, Imane
Khelifa, Mohammed-Rissel
Mezhoud, Samy
Powiązania:
https://bibliotekanauki.pl/articles/396621.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
reinforced concrete
Alfa fiber
polypropylene fibre
temperature
sustainability
fiber length
beton zbrojony
włókno Alfa
włókno polipropylenowe
temperatura
zrównoważony rozwój
długość włókna
Opis:
Alfa fiber reinforced concretes are not used to their full potential due to the limited information on their properties, especially in more severe environments. In this study, the effects of elevated temperature on the properties of concretes reinforced with Alfa fiber were analyzed. The influence of fiber length on reinforced concretes is mainly investigated. For this purpose, five types of structural concretes were formulated; two types of concrete reinforced with 1% Alfa fiber volume using two different fiber lengths of 20 mm and 30 mm (AC-20, and AC-30), and three control concretes, two polypropylene fiber reinforced concretes (PC) using the same fiber length (PC-20, PC-30), and one ordinary concrete (OC). The results showed that with the increase of temperature, the mechanical performance decreased and the porosity rose continually for all mixtures. However, the use of Alfa fiber with a length of 20 mm showed the optimal results in terms of compressive and tensile strength, even at temperatures of 600°C. This finding suggests that Alfa vegetable fiber can be used to produce more sustainable concretes with acceptable mechanical properties compared to the use of polypropylene fiber, even under severe conditions of elevated temperature
Źródło:
Civil and Environmental Engineering Reports; 2020, 30, 3; 161-185
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Durability of hybrid fiber reinforced concrete at various environmental media
Autorzy:
Elhawary, Eslam Ibrahim Nasr
Elsafoury, Ashraf Hassan
Ahmad, Seleem Saleh Elsayed
Powiązania:
https://bibliotekanauki.pl/articles/35555212.pdf
Data publikacji:
2022
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
durability
hybrid fiber concrete
steel fiber
polypropylene fibre
compressive strength
splitting tensile strength
flexural strength
Opis:
Fiber’s addition to concrete mixture attracts researchers to determine the effect of fiber type on durability properties of hybrid performance concrete. In the present work, steel and polypropylene fibers are used in hybrid form in the experimental program. The objective of this paper is to investigate the mechanical properties of hybrid fiber reinforced concrete subjected to four various media: air, water, sodium chloride, and magnesium sulphate with a 7% concentration. The results showed that using hybrid fibers which consist of 1% steel fiber and 0.3% polypropylene fiber improved the compressive strength, splitting tensile strength, and flexural strength for different media for up to 360 days.
Źródło:
Scientific Review Engineering and Environmental Sciences; 2022, 31, 2; 88-100
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Shear performance of reinforced self-compacting concrete beams incorporating steel and polypropylene fibers
Autorzy:
Alkhattat, Saja S.
Al-Ramahee, Munaf A.
Powiązania:
https://bibliotekanauki.pl/articles/35550882.pdf
Data publikacji:
2021
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
steel fiber
lightweight concrete
polypropylene fibre
shear strength
Opis:
The impact of steel and polypropylene fibers on the performance of lightweight self-compacting concrete (LWSCC) beams was investigated in this study. Seven beams with various parameters were cast and tested. Partial (50%) and full (100%) replacement of coarse aggregate with lightweight aggregate expanded clay (LECA) were considered. In addition, a 1% volumetric ratio of steel or hybrid (steel and polypropylene) fiber was added to LWSCC beams to study their effect on the shear performance. The LWSCC beams had a decrease in ultimate load and stiffness of 23 and 30% for partial and full replacement, respectively when compared to normal weight beam. The addition of steel fiber improved the efficiency of LWSCC beams in terms of crack formation, failure mode, crack width, and ultimate load, as well as changed the failure mode from shear to flexure. The ultimate load for hybrid LWSCC was increased by around 6% for a partial replacement and 13% for full replacement as compared to beams without fibers. However, hybrid beams had a larger bearing capacity, little more cracks with smaller size, and ductile failure.
Źródło:
Scientific Review Engineering and Environmental Sciences; 2021, 30, 4; 537-551
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Flexural performance of engineered cementitious compositelayered reinforced concrete beams
Zaprojektowana fleksyjna wydajność belki żelbetowej pokrytej kompozytem cementowym
Autorzy:
Krishnaraja, A. R.
Kandasamy, Dr. S.
Powiązania:
https://bibliotekanauki.pl/articles/230554.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kompozyt cementowy
ECC
włókno polialkoholu winylowego
włókno polipropylenowe
włókno stalowe
hybrydyzacja włókna
moduł Younga
wytrzymałość na zginanie
belka kompozytowa
engineered cementitious composites
fiber hybridation
Young's modulus
flexural strength
composite beam
polyvinyl alcohol fiber
polypropylene fibre
steel fiber
Opis:
This study focuses to develop a new hybrid Engineered Cementitious Composite (ECC) and assesses the performance of a new hybrid ECC based on the steel short random fiber reinforcement. This hybrid ECC aims to improve the tensile strength of cementitious material and enhance better flexural performance in an RC beam. In this study, four different mixes have been investigated. ECC with Poly Vinyl Alcohol (PVA) fiber and PolyPropylene (PP) fiber of 2.0% volume fraction are the two Mono fiber mixes; ECC mix with PVA fiber of 0.65% volume fraction hybridized with steel fiber of 1.35% volume fraction, PP fiber of 0.65% volume fraction hybridized with steel of 1.35% volume fraction are the two additional different hybrid mixes. The material properties of mono fiber ECC with 2.0 % of PVA is kept as the reference mix in this study. The hybridization with fibers has a notable achievement on the uniaxial tensile strength, compressive strength, Young’s modulus, and flexural behavior in ECC layered RC beams. From the results, it has been observed that the mix with PVA fiber of 0.65% volume fraction hybrid with steel fiber of 1.35% volume fraction exhibitimprovements in tensile strength, flexural strength, andenergy absorption. ThePP fiber of 0.65% volume fraction hybridized with steel of 1.35% volume fraction mix has reasonable flexural performance and notable achievement in displacement ductility overthe reference mix.
Zaprojektowany kompozyt cementowy (ECC) jest materiałem przygotowywanym na bazie zaprawy cementowej z wykorzystaniem krótkiego włókna, z udziałem objętościowym do 2,0%. Należy do rodziny Kompozytu Cementowego o Bardzo Wysokiej Wytrzymałości (UHTCC), który wykazuje wyjątkowe właściwości mechaniczne w zakresie umocnienia odkształceniowego, wytrzymałości na rozciąganie i odporności na odkształcenia. Typ, geometria, udział objętościowy i inne właściwości wytrzymałościowe włókien stosowanych w mieszance decydują o mechanicznych zachowaniach ECC. Mieszanki ECC są zwykle opracowywane z wykorzystaniem włókna polialkoholu winylowego (PVA), włókna stalowego (SE), włókna polipropylenowego (PP) i włókna polietylenowego (PE). Celem zastosowania włókien jest poprawa umocnienia odkształceniowego, wytrzymałości na rozciąganie i pochłaniania energii betonu, co zmniejsza uszkodzenia w konstrukcji betonowej poddanej wpływom dynamicznym i uderzeniowym. W celu zbadania zachowania ECC podczas testu ściskania, wykonano test modułu Younga, bezpośrednią próbę rozciągania oraz test zginania na belkach dla 4 różnych mieszanek. Mieszanka 1 (M1) zawiera 2% włókna PVA, mieszanka 2 (M2) zawiera 2% włókna PP, mieszanka 3 (M3) zawiera 0,65% PVA i 1,35% włókien stalowych, mieszanka 4 (M4) zawiera 0,65% PP i 1,35% włókien stalowych.
Źródło:
Archives of Civil Engineering; 2017, 63, 4; 173-189
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechanical properties of concretes modified with steel fibers and polypropylene
Autorzy:
Helbrych, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/24202547.pdf
Data publikacji:
2022
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
polypropylene fibre
steel fibers
fiber-reinforced concrete
concrete
mechanical properties
Opis:
This paper presents the effect of the addition of steel and propylene fibers on the mechanical properties of floor concretes (compressive and tensile strengths in the bending test). The polypropylene fibers used in the tests (fibrillated and single fibers) are dosed in the amount of 0.5 kg/m3 to 2 kg/m3 , and the straight and hooked steel is dosed from 10 kg/m3 to 25 kg/m3 . It is shown that, after 28 days of maturation, the highest compressive strength is achieved by concretes containing the addition of 25 kg/m3 of hook-like steel fiber. In addition, the influence of the fiber content on the consistency of the concrete mix and workability is investigated. It was shown that the amount of steel fibers dosed in the tests, regardless of their shape, did not adversely affect the consistency and workability of the concrete mix. On the other hand, the addition of polypropylene fibers has a significant impact on the characteristics of the concrete mix. The addition of 2 kg/m3 of polypropylene fibers caused the change of consistency from S4 to S1/S2 and worsened the workability of the mixture. All of the tested series of the concrete are created using the same technology. The concrete production technology reflects the concrete production technology for flooring concretes.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2022, 71 (143); 56--63
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Non-destructive characterisation of mortars reinforced with various fibres exposed to high temperature
Autorzy:
Ezziane, M.
Molez, L.
Messaoudene, I.
Powiązania:
https://bibliotekanauki.pl/articles/89226.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Wydział Geoinżynierii, Górnictwa i Geologii. Instytut Górnictwa
Tematy:
mortars
steel fiber
polypropylene fibre
temperature
non-destructive test
Opis:
The objective of this study is to investigate the effect of temperature on the physical and mechanical properties of standard mortar reinforced with steel fibers, polypropylene fibers and hybrid fibers. Non-destructive tests (capillary water absorption, interconnected porosity, gas permeability, ultrasound celerity) were carried out on samples that had been heated, at a temperature ramp of 5 °C/min, to maximum temperature of: 105 °C, 400 °C, 500 °C et 800 °C. The results show a good correlation between the evolution of properties and the damage resulting from the imposed heat exposure treatment. The study shows that there is a significant deterioration of physico-mechanical properties of the fiber mortars above 500 °C. The hybrid fiber mortars show a good compromise: the polypropylene fibers guarantee a thermal stability whereas the steel fibers act to conserve good mechanical behavior.
Źródło:
Mining Science; 2018, 25; 179-194
2300-9586
2353-5423
Pojawia się w:
Mining Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu wysokiej temperatury na zmianę wybranych parametrów wytrzymałościowych fibrobetonu z dodatkiem włókien polipropylenowych
Analysis of influence of high temperature on changes of the selected strength parameters of fiber reinforced concrete with polypropylene fibers
Autorzy:
Bednarek, Z.
Drzymała, T.
Powiązania:
https://bibliotekanauki.pl/articles/136914.pdf
Data publikacji:
2013
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
pożar
fibrobeton
włókna polipropylenowe (PP)
wytrzymałość
moduł sprężystości
fire
fibers reinorced concerete (FRC)
polypropylene fibre
elastic modul
Opis:
W niniejszym referacie autorzy zaprezentowali wyniki badań wytrzymałościowych, których celem była analiza oddziaływania wysokich temperatur występujących podczas pożaru na wytrzymałość fibrobetonu z włóknami polipropylenowymi oraz oszacowanie wielkości spadku wytrzymałości na ściskanie w porównaniu z betonem tej samej klasy bez dodatku włókien. Dodatkowo omówiono procedury badawcze oraz wyniki badań modułu sprężystości fibrobetonu z dodatkiem włókien polipropylenowych poddanego oddziaływaniu wysokiej temperatury zbliżonej do temperatury występującej w środowisku pożaru. Podczas badań stwierdzono korzystny wpływ dodatku włókien polipropylenowych w ilości 1,2 kg/m3 oraz dozowanych do mieszanki betonowej powyżej 1,2 kg/m3 na właściwości wytrzymałościowe betonu w wysokich temperaturach.
In construction engineering practice impact of high temperatures occurring during fire on the concrete structures is an important issue. An unfavorable phenomenon associated with high temperature is surface spalling of large concrete parts, which has a significant impact on the safety of the whole building structure, users and rescue teams. “Concrete thermal spalling” phenomenon in the foreign literature is called “spalling“. One of the possibilities of preventing this negative phenomenon is a technological method consisting in addition of polypropylene fibers to concrete mix. The method results in the increase of resistance of the concrete structure to the explosive spalling in the conditions of increased humidity. In the road tunnels and other non-heated compartments, concrete is characterized by the relatively high water content. The results of many tests prove that the addition of polypropylene fibers (PP) can have a positive impact on the concrete structures subjected to high temperatures and can reflect to the reduction of “spalling” effect. Investigations of high temperatures impact occurring during the fire, on the basic strength parameters of the concrete with addition of polypropylene fibers, were carried out in Poland, at Cracow University of Technology and Main School of Fire Services, among the others. Zoja Bednarek and Tomasz Drzymala conducted investigations at the Main School of Fire Services. During the studies advantageous effect of the addition of 1.2 kg/m3 and above of polypropylene fibers to the concrete mix on the concrete strength properties at high temperatures have been demonstrated. In the presented paper the results of strength tests are shown, which aimed at analyzing the impact of high temperatures occurring during the fire on the strength of fiber reinforced concrete with polypropylene fibers, as well as estimating reduction of compressive strength compared to the concrete of the same class but without addition of fibers. Additionally, the applied research methods are discussed and elasticity modulus test results of fiber reinforced concrete subjected to high temperatures close to fire temperatures are presented. Taking into account the undoubtedly positive influence of PP fibers addition on the reduction of concrete “spalling”, the authors investigated the manner in which such addition influences different strength properties of the concrete at high temperatures conditions. From this point of view the impact of high temperatures on the compressive strength and elasticity modulus were investigated. Samples were prepared with the use of normal C30/37 class concrete and high strength C60/75 class concrete. For the concrete mix three different types of polypropylene fibers were used, differing in length and thickness of single fibers, in the following amount: 0.6 kg/m3, 0.9 kg/m3, and 1.2 kg/m3. The selected fibers used as the additives to concrete mix are easily available on the European market. Preliminary studies were carried out to deter-mine the influence of fire temperatures on the flammable properties of fibers in oxygen and nitrogen atmosphere. The conducted studies have demonstrated a significant impact of the atmosphere, in which degradation of samples take place, on the results of TG and DTG analysis. The atmosphere had a crucial effect on the initial temperature of degradation, temperature of the partial mass loss, temperature of termination of degradation, temperature of maximum mass loss rate and nondegradable residues mass remaining in the concrete. The results of the studies allow assuming that in the condi-tions of oxygen depletion, degradation of PP fibers in the concrete would occur much slower. The above assumption has been confirmed by the observations of the concrete structure, by means of scanning microscope (SEM), with regards to the fibers condition inside the concrete samples. Based on the obtained results the following conclusions have been formulated: 1. The addition of PP fibers has a negative impact on the compressive strength of C30/37 class concrete, especially in normal temperatures and temperatures raised to about 200ºC. Above 300ºC a reduction of strength of this concrete is identical to the strength reduction of the concrete without PP fiber addition. 2. In case of fiber reinforced concrete and C60/75 class concrete, compressive strength reduction in the whole temperature range can be considered as identical. 3. No significant influence of the type of the applied PP fibers on the reduction of compressive strength for both classes of fiber reinforced concrete has been demonstrated. 4. In case of both classes of fiber reinforced concrete the compressive strength is reduced in high temperatures. Moreover, the strength reduction of C30/37 concrete proceeds faster. At 800ºC the strength of normal concrete and fiber reinforced concrete of C30/37 class decreases of about 90%, whereas in case of concrete and fiber reinforced concrete of C60/75 class such reduction occurs at 1000ºC. 5. Analyzing the results with regards to the impact of PP fibers addition to the concrete in the quantities above 1.2 kg/m3, it can be concluded that such addition does not enhance strength reduction of the concrete in fire temperatures. Therefore, in case of fiber reinforced concrete the identical principles can be applied for strength determination, as in case of the concrete without PP fibers in fire temperatures. The reduced compressive strength of the concrete with addition of PP fibers in temperature T can be described by the following formula: fck(T) = kc (T) ... fck ---- (1) where: fck – specific compressive strength of fiber reinforced concrete at normal temperature (20ºC) kc(T) – assumed reduction coefficient as for the corresponding class concrete without addition of fibers. 6. Based on the results analysis a positive impact of PP addition on the elasticity modulus of C30/37 and C60/75 class concrete in high fire temperatures can be concluded. 7. In both cases higher growing tendencies have been observed for C30/37. In normal temperature no impact of PP fibers addition on the elasticity modulus values can be noticed. 8. At the elevated and high temperatures a slightly lower elasticity modulus reduction in case of fiber reinforced concrete with PP fibers can be observed. It is especially evident at 300ºC. Summing up: addition of 1.2 kg/m3 of polypropylene fibers to the concrete, in order to reinforce the concrete against dangerous explosive spalling during the fire, is advantageous also from the point of view of the concrete strength at fire temperatures.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2013, 3, 47; 127-138
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stany zarysowania i ugięcia tarcz żelbetowych z otworami z fibrobetonu wysokowartościowego
Analysis of crack and deflection states of high performance reinforced fiber concrete deep beams with openings
Autorzy:
Smarzewski, P.
Powiązania:
https://bibliotekanauki.pl/articles/211302.pdf
Data publikacji:
2014
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
tarcze żelbetowe z otworami
beton wysokowartościowy
włókno stalowe
włókno polipropylenowe
stan zarysowania
ugięcia
reinforced concrete deep beams with openings
high performance concrete
steel fibre
polypropylene fibre
crack state
deflections
Opis:
W artykule przedstawiono analizy stanów zarysowania i ugięcia tarcz żelbetowych z otworami z betonu wysokowartościowego z włóknami stalowymi i polipropylenowymi. Badania przeprowadzono dla trzech elementów zróżnicowanych pod względem ilości i rodzaju zbrojenia. W tarczy T1 skonstruowano tradycyjne zbrojenie prętami stalowymi. W tarczach T2 i T3 zamiast siatek zastosowano zbrojenie rozproszone o zmiennej procentowej objętości włókien. Analizy zachowania tarcz pod obciążeniem statycznym przedstawiono na podstawie pomiarów rys i ugięć.
The article presents the crack and deflection states analysis of the reinforced deep beams with openings made of high performance steel and polypropylene fibre concrete. Research was carried out with regard to quantity and the type of reinforcement. The deep beam T1 was constructed conventionally with steel rods reinforcement. As regards deep beams T2 and T3, instead of the steel wire mesh, fibre reinforcement of variable fibre volume percentage was applied. The analysis of the behaviour of the deep beams under static load was based on the measurements of cracks and deflections.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2014, 63, 3; 147-157
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stany zarysowania i odkształcenia belek żelbetowych z betonu wysokowartościowego z dodatkiem włókien
Analysis of crack and strain states of high performance reinforced fiber concrete beams
Autorzy:
Smarzewski, P.
Powiązania:
https://bibliotekanauki.pl/articles/208987.pdf
Data publikacji:
2014
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
belka żelbetowa
beton wysokowartościowy
włókno stalowe
włókno polipropylenowe
system ARAMIS
stan zarysowania
stan odkształcenia
reinforced concrete beams
high performance concrete
steel fibre
polypropylene fibre
Aramis system
crack state
strain state
Opis:
W artykule przedstawiono analizy stanów zarysowania i odkształcenia belek żelbetowych z betonu wysokowartościowego z dodatkiem włókien stalowych i polipropylenowych poddanych zginaniu w schemacie czteropunktowym. Badania przeprowadzono dla trzech belek zróżnicowanych pod względem ilości i rodzaju zbrojenia. W belce B1 skonstruowano tradycyjne zbrojenie prętami stalowymi. W elementach B2 i B3 zamiast strzemion i prętów górnych zastosowano zbrojenie rozproszone o zmiennej procentowej objętości włókien. W analizach wykorzystano system ARAMIS do bezkontaktowych trójwymiarowych pomiarów odkształceń. Analizy zachowania belek pod obciążeniem statycznym przedstawiono na podstawie pomiarów rys i odkształceń.
The article presents the crack and strain states analysis of the reinforced high performance concrete beams with steel and polypropylene fibre. The beams were bent in the 4-point model. Research was carried out for three different beams with regard to the quantity and the type of reinforcement. The beam B1 was constructed conventionally with steel rods reinforcement. As regards beams B2 and B3, instead of the stirrups and the compressive rods, fibre reinforcement of variable fibre volume percentage was applied. For the analysis, a non-contact system for three-dimensional measurements of strain - ARAMIS was used. The analysis of the behaviour of the beams under static load was based on the measurements of crack and strain.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2014, 63, 3; 135-145
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-14 z 14

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies