Tytuł:
Analiza kosztów nieużytkowania lub organiczenia wielkości poboru wody z zakładu uzdatniania wody Goczałkowice
Analysis of costs for resignation or limitation of water intake from Water Treatment Plant Goczałkowice
Autorzy:
Panasiuk, Damian
Powiązania:
https://bibliotekanauki.pl/articles/684644.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Łódzki. Wydawnictwo Uniwersytetu Łódzkiego
Tematy:
pobór wody
koszty
zakład uzdatniania wody
water intake
costs
water treatment plant
Opis:
Regional Upper Silesia Waterworks (GPW S.A.) are the biggest water supply system in Poland with 11 water treatment plants and 3 million of consumers. However this system is gradually disassembled. Local water and sewage utilities develop separate water intakes or import water from Czechia with using of GPW S.A. system only as reserve source. It is effect of increasing unit costs of water delivered by GPW S.A. These costs are partly associated with maintenance of flood control reservoirs and additional taxes. Water treatment plant Goczałkowice is main, most modern and cheaper water producer in GPW S.A. system. Thus full resignation of water intake from this source is unlikely. However limitation of water intake by Goczałkowice plant could reduce competitiveness of this WTP by increase of average fixed costs. Limitation of production by other water treatment plants should be more rational. Additionally in result of gravity flow intake of water by Goczałkowice plant from Soła river is more profitable than intake from other sources.
Górnośląskie Przedsiębiorstwo Wodociągów (GPW S.A.) jest największym systemem zaopatrzenia w wodę w Polsce z 11 stacjami uzdatniania wody i 3 mln konsumentów. Jednak system ten jest stopniowo rozmontowywany. Lokalne przedsiębiorstwa wodno-kanalizacyjne rozbudowują własne ujęcia wody lub importują wodę z Czech, traktując system GPW S.A. tylko jako źródło rezerwowe. Jest to efekt wzrastających kosztów jednostkowych wody dostarczanej przez GPW S.A.Koszty te cześciowo są związane z utrzymywaniem zbiorników przeciwpowodziowych oraz dodatkowymipodatkami. Zakład Uzdatniania Wody Goczałkowice jest głównym, najnowocześniejszym i najtańszym producentem wody w systemie GPW S.A. Wobec tego całkowita rezygnacja z poboru wody z tego źródła jest mało realna. Jednakże ograniczenie poboru wody z zakładu Goczałkowice zmniejszyłoby konkurencyjność tej stacji w wyniku wzrostu średnich kosztów stałych. Bardziej racjonalne byłoby ograniczenie produkcji w innych stacjach uzdatniania wody. Ponadto, ze względu na spływ grawitacyjny, pobór wody z Soły przez zakład Goczałkowice jest bardziej opłacalny niż pobór z innych źródeł.
Źródło:
Gospodarka w Praktyce i Teorii; 2016, 44, 3
1429-3730
2450-095X
Pojawia się w:
Gospodarka w Praktyce i Teorii
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Raw Water Quality Assessment for Improvement Plan at Thu Duc Water Treatment Plant, Vietnam
Ocena jakości wody surowej na potrzeby planu poprawy w stacji uzdatniania wody Thu Duc w Wietnamie
Autorzy:
Ho, Ngo Anh Dao
Nguyen, Thi Minh Trang
Nguyen, Thi Trang Trung Nghia
Ngo, Minh Khoi
Powiązania:
https://bibliotekanauki.pl/articles/2172072.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
water intake
monitoring
run-off flow
organic matter
water treatment process
Thu Duc Water Treatment Plant
Vietnam
pobór wody
odpływ
materia organiczna
proces uzdatniania wody
zakład uzdatniania wody Thu Duc (miasto Ho Chi Minh, Wietnam)
Opis:
A conventional water treatment process is currently operated at Thu Duc Water Treatment Plant (TDWTP, Ho Chi Minh City, Vietnam) in which raw water is collected from Dong Nai River at Hoa An water intake and pumping station. The raw water quality is currently fluctuated due to the effects of run-off flows which has been increasing recently. This issue directly affects the operation and performance of existing treatment process at TDWTP since the current treatment are all based on traditional technologies and have been operating for a long time. This study is conducted to evaluate the quality of raw water collected at Hoa An intake station during the period of 2018–2020 with the aim to support the consideration of improvement and enhance the operation efficiency at TDWTP. The raw water quality is evaluated by investigating physico-chemical and biological parameters during the 36 months monitoring. This helps to produce a feasible and reliable results which may then can be used as a scientific database for the improvement plan at TDWTP. Results show that the changes of water quality during the investigated time is so complicated, and the concentration of most monitoring parameters is highly seasonal fluctuated. Specifically, the amounts of organic matters, microorganism, nitrogen compounds (NH4 +, NO2 - , NO3 - ) tend to increase strongly, which may be due to the urbanization and industrialization. The management of run-off flows on upstream of water intake and pumping station is also an important aspect which need to be considered to prevent the diffusion and spread of pollution. In addition, the effects of climate changes are the important reason which leads to the seasonal changes of flow and water quality. These issues cause a big challenge for TDWTP to maintain the treatment efficiency and overall performance. This study also proposes several management and technical solutions to address the changes of raw water quality in the future, which may be useful for TDWTP during their consideration to improve the treatment process.
Konwencjonalny proces uzdatniania wody jest obecnie prowadzony w zakładzie uzdatniania wody Thu Duc (TDWTP, miasto Ho Chi Minh, Wietnam), w którym surowa woda jest pobierana z rzeki Dong Nai i z przepompowni Hoa An. Jakość wody surowej podlega obecnie wahaniom ze względu na skutki spływów, które ostatnio nasilają się. Kwestia ta ma bezpośredni wpływ na funkcjonowanie i wydajność istniejących procesów oczyszczania w TDWTP, gdyż wszystkie obecne działające oczyszczalnie oparte są na tradycyjnych technologiach i działają od dłuższego czasu. Niniejsze badanie ma na celu ocenę jakości wody surowej pobieranej ze stacji poboru Hoa An w latach 2018–2020 w celu wsparcia rozważań nad poprawą i zwiększeniem efektywności działania TDWTP. Jakość wody surowej oceniana jest poprzez badanie parametrów fizykochemicznych i biologicznych podczas 36-miesięcznego monitoringu. Pozwoliłó to uzyskanie wiarygodnych wyników, które następnie mogą być wykorzystane jako naukowa baza danych dla planu modernizacji TDWTP. Wyniki pokazują, że zmiany jakości wody w badanym okresie są bardzo złożone, a stężenia większości parametrów monitoringu podlegają dużym wahaniom sezonowym. Szczególnie silnie wzrastają ilości materii organicznej, mikroorganizmów, związków azotu (NH4 +, NO2 - , NO3 - ), co może być spowodowane urbanizacją i uprzemysłowieniem. Ważnym aspektem, który należy wziąć pod uwagę, aby zapobiec rozprzestrzenianiu się zanieczyszczeń, jest również zarządzanie przepływami odpływowymi przed ujęciem wody i przepompownią. Ponadto skutki zmian klimatu są ważną przyczyną sezonowych zmian przepływu i jakości wody. Kwestie te stanowią duże wyzwanie dla TDWTP, aby utrzymać skuteczność oczyszczania i ogólną wydajność. W niniejszym opracowaniu zaproponowano również kilka rozwiązań w zakresie zarządzania i rozwiązań technicznych mających na celu zajęcie się zmianami jakości wody surowej w przyszłości, które mogą być przydatne dla TDWTP podczas rozważań nad poprawą procesu oczyszczania.
Źródło:
Inżynieria Mineralna; 2022, 2; 135--140
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies