Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "wysoka temperatura" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Application of ultrasonic pulse velocity test to concrete assessment in structures after fire
Wykorzystanie metody ultradźwiękowej do oceny betonu w konstrukcjach po pożarze
Autorzy:
Wróblewska, Julia
Kowalski, Robert
Głowacki, Michał
Juchnowicz-Bierbasz, Bogumiła
Powiązania:
https://bibliotekanauki.pl/articles/1852335.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
beton
wysoka temperatura
uszkodzenie
pożar
metoda ultradźwiękowa
pomiar liniowy
głowice eksponencjalne
concrete
high temperature
damage
fire
ultrasonic pulse velocity
UPV
linear measurement
exponential transducers
Opis:
The paper presents the description and results of ultrasonic pulse velocity tests performed on heated beams. The studies aimed to verify the suitability of the UPV method for the assessment of the damaged external layer in the cross-section of RC members after a fire. Four beams heated in a planned way from the bottom (a one-way heat transfer) for 60, 120, 180 and 240 minutes and one unheated beam were examined. The tests were performed using an indirect UPV method (linear measurement on the heated surface). Reference tests were conducted using a direct UPV method (measurement across the member section, parallel to the isotherm layout). Exponential transducers were used for testing concrete surface, which was degraded in high temperature and not grinded. The estimated thicknesses of the destroyed external concrete layer corresponded to the location of the isotherm not exceeding 230oC. Therefore, this test can be used to determine at which depth in the member crosssection the concrete was practically undamaged by high temperature.
W artykule przedstawiono opis i wyniki badań mających na celu sprawdzenie przydatności metody ultradźwiękowej do oceny jakości betonu w konstrukcjach po pożarze. W warunkach pożarowych w przekroju elementów żelbetowych występuje nieustalony przepływ ciepła. Powierzchnia elementów nagrzewa się szybciej niż ich wnętrze. Największa degradacja betonu zachodzi w strefie przypowierzchniowej. W związku z tym podczas oceny konstrukcji po pożarze szczególnie istotne jest określenie grubości zewnętrznej warstwy przekroju elementu, w której beton jest na tyle uszkodzony, że należy go uznać za zniszczony. Metoda ultradźwiękowa jest znormalizowana i powszechnie stosowana do badania betonu in situ. Mierzony jest czas przejścia fali ultradźwiękowej w betonie pomiędzy, umieszczonymi na jego powierzchni, głowicą nadawczą i odbiorczą betonoskopu. W warunkach zwykłych na podstawie prędkości fali można oszacować wytrzymałość betonu na ściskanie, stosując zależności korelacyjne.
Źródło:
Archives of Civil Engineering; 2021, 67, 3; 395-413
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studying the Flexural Behavior of Reinforced Concrete Beams under the Effect of High Temperature: A Finite Element Model
Autorzy:
Al-Baijat, Hamadallah
Alhawamdeh, Mohammad
Khawaldeh, Aya
Powiązania:
https://bibliotekanauki.pl/articles/102512.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
flexural behaviour
reinforced concrete beam
high temperature
fire
finite element model
deflection
zachowanie przy zginaniu
belka żelbetowa
wysoka temperatura
pożar
model elementu skończonego
ugięcie
Opis:
The strength of concrete elements can be greatly affected by elevated temperature as in fires, and so a great concern must be taken regarding its behavior under such condition. In this paper, a finite element model was built up using ABAQUS software to investigate the flexural behavior of reinforced concrete (RC) beams subjected to service load under elevated temperature. The beam was simply supported and was loaded at one-third and two-third of span length. The study consisted of three RC beams models; the first model simulated a control beam specimen at ambient temperature 20 °C, while the other two models demonstrated damaged beams specimens according to two high temperatures 400 °C and 800 °C, respectively. Each RC beam had 2 m span length, 300 mm height and 200 mm width. The steel reinforcement configuration was 3ϕ16 mm (Grade 60) main bars at the positive moment region in the beam bottom, 2ϕ14 mm (Grade 60) secondary bars at the beam top, and ϕ10 mm /150 mm closed stirrups. The model was validated by comparing its results with the theoretical results from ACI code and literature. Several mechanical properties were investigated including concrete compressive strength, modulus of elasticity, and reinforcing steel yielding strength. The test results showed a reduction in the flexural capacity of the RC beams, tested at 400 °C and 800 °C, of 17.6% and 88.2%, respectively, with respect to the control beam. The maximum service load carried by the beam, at one-third and two-third of the span length, decreased by 17.1% and 88.1% for the 400 ℃ and 800 ℃ high temperature, respectively. The results also showed an increase in deflection when the temperature increased due to the loss in stiffness.
Źródło:
Advances in Science and Technology. Research Journal; 2019, 13, 2; 150-156
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Akcja gaśnicza ze szczątkami ofiary śmiertelnej w tle
Firefighting Operations with Human Corpses in the Background
Autorzy:
Włodarczyk, R.
Powiązania:
https://bibliotekanauki.pl/articles/372946.pdf
Data publikacji:
2015
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
pożar
akcja gaśnicza
wysoka temperatura
pogorzelisko
oględziny
ślady
szczątki ludzkie
N.N. zwłoki
badania genetyczne
wersja kryminalistyczna
fire
firefighting
high temperature
fire incident site
examination
evidence
human remains
unknown body
genetic testing
criminal version
Opis:
Cel: Celem niniejszego doniesienia jest zapoznanie funkcjonariuszy wykonujących czynności służbowe na miejscu pogorzeliska z wybranym przypadkiem z praktyki. Ma on uzmysłowić zainteresowanym podmiotom, jak wiele śladów i mikrośladów biologicznych jest tam pomijanych. Materiał dowodowy jako niemy „świadek” może przekazać wiedzę o zdarzeniu, jednak traci się go przez niezauważenie na etapie akcji ratowniczo-gaśniczej i nieostrożność w czasie oględzin. Celem pośrednim jest wykazanie błędów możliwych do uniknięcia przez zespół oględzinowy, co wymiernie może poprawić jakość przyszłych ustaleń w sprawie. Wprowadzenie: Choć w praktyce ma się do czynienia z różnymi przyczynami powstawania płomieni, jednak podczas akcji gaśniczej należy liczyć się zarówno z dotarciem do osób żywych, zwłok, jak i szczątków ludzkich. Mogą one być zachowane w złym stanie, co stwarza problemy z ustaleniem tożsamości. Kazus ten pokazuje, jak niefrasobliwość w wypełnianiu obowiązków służbowych utrudnia dotarcie do prawdy obiektywnej, mimo posiadania informacji o przebywaniu co najmniej 1 osoby w domu, która uległa spaleniu. Metodologia: W etapie wstępnym scharakteryzowano miejsce wybuchu pożaru, który zaistniał w terenie ze stosunkowo dogodnymi warunkami do realizacji zadań służbowych. W drugim etapie stanowiącym opis akcji gaśniczej i oględzin na miejscu pogorzeliska dowiedziono, że mimo uzyskanych informacji nie brano pod uwagę obecności szczątków ludzkich. Późniejsze oględziny pogorzeliska doprowadziły do ujawnienia ciała ludzkiego, które było rozczłonkowane i zdegradowane. W kolejnym etapie dokonano analizy materiału dowodowego i jego przydatności do wyjaśnienia wątpliwych kwestii. Dzięki wnioskowaniu sformułowano konkluzje dotyczące metod i skutków, przez zestawienie przyczyn błędnego postępowania w trakcie oględzin. Końcowy etap rozważań udowadniał, jak zatarcie śladów związanych ze zdarzeniem ograniczyło możliwości badawcze i wykrywcze. Wnioski: W artykule próbowano dowieść, jak ukierunkowane popożarowe czynności procesowe i pozaprocesowe mogą na dalszych etapach doprowadzić do efektywnego wykorzystania zabezpieczonych śladów oraz wyjaśnić okoliczności sprawy. Bowiem sensownie realizowane postępowanie przygotowawcze, bazujące na słabo widocznych śladach biologicznych wraz z aktualnymi możliwościami genetycznymi, doprowadza do identyfikacji osób związanych ze zdarzeniem. Jednakże ważne jest przestrzeganie rygorów postępowania. Przytaczanie tego kazusu ma uświadamiać niepożądane konsekwencje niekompetentnych działań.
Aim: The purpose of this report is to familiarize officers, who perform duties at fire incidents, with a selected practical example. It is intended to make officers aware of the volume of evidence, biological and other, which can be overlooked. The evidence, just like a mute witness, can provide information about an incident. However, information can be lost throug inadvertence during rescue and firefighting operations and imprudence during post incident inspections. An intermediate aim is to reveal potential errors, which can be avoided, identified by a technical working group of Inspectors. Avoidance of such errors could significantly improve the quality of future investigation findings. Introduction: In spite of different reasons for the cause of a fire, it should be understood that rescue activity will ultimately bring firefighters into contact with live people, corpses and human remains. The latter two may be preserved in a poor condition, culminating with difficulties in establishing individual identities. This case illustrates where apathy in the performance of duty may have caused difficulties with attempts to establish objective facts, despite availability of information about the existence of at least 1 person, who was burnt in the house fire. Methodology: At the initial stage a suitable location involving a fire outbreak was identified. It was a location with easy access for firefighting and rescue operations. At the second stage a description of firefighting activities was produced and was accompanied by a post incident site inspection. At this point it was realised that, despite information concerning incident operations, the presence of human remains were ignored. A later inspection of the fire incident site revealed a degraded and dismembered human body. Next, the collected evidence was analyzed and its utility determined for use in resolving areas of doubt.. With the aid of deduction methods, some conclusions were reached about methods and effects as well as reasons for flawed procedures adopted during the site inspection. The final stage of deliberations established how erasure of relevant evidence constrained detection and research investigation. Conclusions: The article attempted to demonstrate that suitably focussed post incident investigations may, at later stages of proceedings, lead to effective utilisation of preserved evidence as well as provide an explanation of circumstances. A sensibly developed preparatory process, based on not so easy to see biological evidence, but aided by current genetic potential, leads to identification of individuals associated with incidents. However, it is important to maintain a disciplined approach to the process. Presentation of this incident is intended to make people aware of undesirable consequences associated with incompetent performance.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2015, 1; 181-195
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal bowing of reinforced concrete elements exposed to non-uniform heating
Swobodne wyginanie się elementów żelbetowych pod wpływem nierównomiernego ogrzewania
Autorzy:
Kowalski, R.
Głowacki, M.
Wróblewska, J.
Powiązania:
https://bibliotekanauki.pl/articles/230904.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
belka żelbetowa
temperatura wysoka
pożar
ugięcie
wyginanie termiczne
gradient temperatury
reinforced concrete beam
high temperature
fire
deflection
thermal bowing
temperature gradient
Opis:
The paper presents the test description and results of thermal bowing of RC beams exposed to non-uniform heating at high temperature. Bending of a non-uniformly heated element is caused by free thermal elongation of the material it is made of. The higher the temperature gradient, the greater the bending. In the case when an element is exposed to load and high temperature simultaneously, apart from free bending also deformation of the RC element may occur, which is caused by the decrease of the concrete or reinforcing steel mechanical properties. In order to examine the contribution of the deflection caused by thermal bowing to the total deformation of the bent element with a heated tension zone, an experimental study of freely heated (unloaded) beams was performed. RC beams were heated: (1) on three sides of the cross-section or (2) only on the bottom side. Deflection of elements loaded by a substitute temperature gradient was calculated using the Maxwell-Mohr formula. The test results show that deflection of freely heated RC beams (caused by the thermal bowing phenomenon) can be 10 to 20% of the total deflection of loaded RC beams with a heated tension zone.
W artykule przedstawiono opis i wyniki badań swobodnego wyginania się belek żelbetowych narażonych na nierównomierne ogrzewanie w temperaturze pożarowej. Elementy żelbetowe ogrzewane nierównomiernie wyginają się na skutek swobodnej wydłużalności termicznej materiału, a wygięcie jest tym większe, im większy jest gradient temperatury w przekroju. W literaturze zjawisko to jest nazywane thermal bowing. Zachodzi ono niezależnie od obciążenia elementu. W statycznie niewyznaczalnych elementach zginanych może ono powodować powstawanie dodatkowych sił wewnętrznych, a w elementach ściskanych (słupach) zwiększenie mimośrodu siły podłużnej. W elementach wytężonych podczas ogrzewania, oprócz swobodnego wyginania się powstają jeszcze deformacje spowodowane pogorszeniem właściwości mechanicznych betonu lub stali. W celu określenia, jaką część całkowitej deformacji wytężonego elementu ogrzewanego nierównomiernie od strony strefy rozciąganej może stanowić ugięcie wywołane zjawiskiem thermal bowing, przeprowadzono badania wyginania się nieobciążonych belek żelbetowych. W sumie zbadano siedem belek o przekroju 160 x 200 mm, długości 1300 mm, wykonanych z betonu klasy C35/45 z kruszywem żwirowym (krzemianowym). Średnia wytrzymałość betonu na ściskanie oznaczona na próbkach sześciennych o boku 150 mm wynosiła odpowiednio 46,3 MPa - po 28 dniach od zabetonowania oraz 60,8 MPa - po około 4 miesiącach (przed przystąpieniem do badań). Średnia granica plastyczności stali określona eksperymentalnie wynosiła 560 MPa.
Źródło:
Archives of Civil Engineering; 2018, 64, 4/I; 247-264
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of a sclerometer to the preliminary assessment of concrete quality in structures after fire
Wykorzystanie sklerometru do wstępnej oceny jakości betonu w konstrukcjach po pożarze
Autorzy:
Kowalski, R.
Wróblewska, J.
Powiązania:
https://bibliotekanauki.pl/articles/231307.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
beton
temperatura wysoka
pożar
badanie nieniszczące
sklerometr
młotek Schmidta
liczba odbicia
concrete
high temperature
fire
non destructive test
sclerometer
Schmidt hammer
rebound number
Opis:
The paper presents a description and results of a study focused on the applicability of the sclerometric method to the preliminary assessment of concrete quality in structures after fire. Due to the high thermal inertia, concrete has non-uniform properties in the heated element cross-section. The greatest reduction of concrete compressive strength occurs on the heated surface. When assessing a structure after a fire, it is particularly important to determine the thickness of the damaged external concrete layer. Reinforced concrete beams exposed to high temperature on one side (a one-way heat transfer in the cross-section) for 0 (unheated element), 60, 120, 180 and 240 minutes were examined. A significant decrease of the rebound number on the elements heated surface was observed, depending on the heating duration. The obtained values of the relative rebound number reduction were comparable to the values of relative compressive strength decrease (determined on the basis of temperature) of concrete situated 15 mm from the heated surface.
W artykule przedstawiono opis i wyniki badań mających na celu sprawdzenie przydatności metody sklerometrycznej do wstępnej oceny jakości betonu w konstrukcjach po pożarze. Jednym z najistotniejszych zjawisk wpływających na nośność konstrukcji narażonej na warunki pożarowe jest obniżenie wytrzymałości betonu w wysokiej temperaturze w wyniku procesów fizyko-chemicznych i uszkodzeń mechanicznych zachodzących w jego strukturze. Ze względu na dużą bezwładność termiczną, beton przestaje mieć jednorodne właściwości w przekroju ogrzewanego elementu, a największa degradacja betonu zachodzi w strefie przypowierzchniowej. Podczas oceny konstrukcji po pożarze szczególnie istotne jest określenie grubości zewnętrznej warstwy przekroju elementu, w której beton jest na tyle uszkodzony, że należy go uznać za zniszczony. Z praktycznego punktu widzenia rozpatrywania nośności konstrukcji można przyjąć, że grubość tej warstwy odpowiada odległości izotermy 500°C od ogrzewanej krawędzi przekroju.
Źródło:
Archives of Civil Engineering; 2018, 64, 4/II; 171-186
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odkształcenia, relaksacja i zmniejszenie wytrzymałości stali sprężającej w temperaturze pożarowej. Wskazówki na temat praktycznego wykorzystania modelu Eurokodu 2-1-2
Strains, relaxation and strength loss of prestressing steel at fire temperature. Guidance on the practical use of the Eurocode 2-1-2 model
Autorzy:
Kowalski, Robert
Juchnowicz-Bierbasz, Bogumiła
Wróblewska, Julia
Powiązania:
https://bibliotekanauki.pl/articles/2142043.pdf
Data publikacji:
2022
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
stal sprężająca
odkształcenie
relaksacja
zmniejszenie wytrzymałości
wydłużenie
pożar
temperatura wysoka
projektowanie
modelowanie
prestressing steel
strain
relaxation
strength reduction
elongation
fire
high temperature
designing
modelling
Opis:
W artykule przedstawiono wskazówki na temat wykorzystania modelu pogorszenia właściwości mechanicznych stali sprężającej w wysokiej temperaturze, podanego w EC2‑1-2, przydatne do oszacowania zmniejszenia siły sprężającej w elementach narażonych na warunki pożarowe. Adekwatne oszacowanie tej siły ma kluczowe znaczenie podczas obliczeń nośności ogniowej elementów sprężonych. Przyjęcie do analiz wyłącznie obniżenia wytrzymałości stali określonego na podstawie modelu EC2-1-2 może być przyczyną znacznego niedoszacowania zmniejszenia siły sprężającej w warunkach pożaru. Do adekwatnego oszacowania tej siły konieczne jest zsumowanie odkształcenia cięgien sprężających powstałego na skutek pogorszenia ich właściwości mechanicznych pod wpływem wysokiej temperatury i swobodnego wydłużenia termicznego stali.
The paper gives guidance on the use of the EC2 1-2 model of deterioration of the mechanical properties of prestressing steel at high temperature useful for estimating the loss of prestressing force in elements exposed to fire. Adequate estimation of this force is crucial when calculating the fire resistance of prestressed members. If only the reduction in steel strength determined on the basis of the EC2-1-2 model is considered for the analysis, it may cause a significant underestimation of the prestress loss under fire conditions. In order to adequately estimate this force, it is necessary to sum up the strain of the prestressing tendons resulting from the deterioration of their mechanical properties under the influence of high temperature and the free thermal elongation of the steel.
Źródło:
Przegląd Budowlany; 2022, 93, 5-6; 123--129
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies