Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Physicochemical" wg kryterium: Temat


Tytuł:
Content of the Label Paper and the Variation of Physico-Chemical Parameters in Bottled Water in Kosovo
Autorzy:
Çadraku, Hazir
Powiązania:
https://bibliotekanauki.pl/articles/2202226.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
water quality
bottled water
physicochemical parameter
Kosovo
Opis:
Water is a vital resource for the existence of mankind and all ecosystems on Earth. Before using it, it must be ensured that water is of good quality, within the hygienic-sanitary norms for human consumption. In recent decades, the supply of drinking water has been supplemented with the water bottled in glass and plastic bottles, which is found everywhere in the market of the Republic of Kosovo. This paper deals with the content of the label paper and the variation of physico-chemical parameters of bottled water which is extracted, analyzed, processed, filled, packaged and distributed on the market of the Republic of Kosovo and beyond as a product for consumption. i.e. In this paper 20 brands of groundwater (types of water) produced and packaged in the territory of Kosovo.
Źródło:
Journal of Ecological Engineering; 2022, 23, 11; 122--131
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of Water Quality Index of Selected Water Bodies in Warri, Delta State, Nigeria
Autorzy:
Ama, Ibiam Ntachiobi
Ebichime, Nwajei Godwin
Agbaire, Patience Odafe
Verla, Andrew Wirnkor
Powiązania:
https://bibliotekanauki.pl/articles/1112889.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
arithmetic index
physicochemical parameter
water quality index (WQI)
Opis:
Water Quality index indicating the water quality in terms of index number, offers a useful representation of overall quality of water for public or for any intended use, as well as in pollution abatement programmes and in water quality management. The present study was carried out to determine the Water Quality Index (WQI) of selected rivers in Warri, Delta State, using fourteen physicochemical parameters and on the basis of weighted Arithmetic Index in order to access the suitability of this water for consumption, recreation and other purposes. The parameters were measured monthly for one year at the six selected water bodies. In this study, WQI was determined by the analysis-on the basis of various physicochemical parameters such as pH, chlorides, electrical conductivity, dissolved oxygen, biochemical oxygen demand, total dissolved solid, total suspended solids, chlorides, sulphates, chemical oxygen demand, oil/grease. Result obtained for the different sampling sites were found to fall within the WQI classifications - poor water (100-200) to unsuitable water or unfit (>300). There is, therefore, the need to periodically assess these water bodies to ensure the quality is suitable for the intended purpose.
Źródło:
World News of Natural Sciences; 2018, 16; 42-52
2543-5426
Pojawia się w:
World News of Natural Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessing Water Quality of Kufranja Dam (Jordan) for Drinking and Irrigation: Application of the Water Quality Index
Autorzy:
Abualhaija, Mahmoud M.
Mohammad, Alsharifa-Hind
Powiązania:
https://bibliotekanauki.pl/articles/1955562.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
Kufranja Dam
Jordan
physicochemical parameter
water quality index
drinking
irrigation
Opis:
The current study was undertaken to assess the physicochemical quality of the Kufranja dam (KD) surface water in northern Jordan during the summer and winter seasons [2019]. The samples were analyzed for temperature, pH, dissolved oxygen, conductivity, major cations, major anions, and heavy metals. Most of the physicochemical parameters exhibited a similar spatial distribution, where the maximum concentrations were observed at the dam’s entrance, while the minimum concentrations were recorded at the dam’s end. This indicates that the factors affecting their occurrence and distribution are the same, including natural discharges from the surrounding catchment areas, weathering products, agricultural activities, and wastewater effluents that enter the dam via Wadi Kufranja. All the physicochemical parameters and heavy metals in KD water lie below the maximum permissible levels of the Jordanian and international standards for drinking and irrigation, except for EC values that are above WHO standards for drinking. The application of the water quality index (WQI) depicts that the KD water is chemically unsuitable for use in drinking and needs proper treatment before use. The irrigation indices (SAR, Na%, and MH) indicate that the KD water is chemically suitable for irrigation, whereas EC results and USSL diagram showed that the dam’s water is suitable for irrigation and belongs to the categories of good to permissible for irrigation. Therefore, KD water is suitable for irrigation of most soils (except soils with low salt tolerance). Crops with good salt tolerance are recommended and a special treatment of salinity might be required.
Źródło:
Journal of Ecological Engineering; 2021, 22, 9; 159-175
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Water Quality Assessment of the Morava e Binçës River Based on the Physicochemical Parameters and Water Quality Index
Autorzy:
Musliu, M.
Bilalli, A.
Durmishi, B.
Ismaili, M.
Ibrahimi, H.
Powiązania:
https://bibliotekanauki.pl/articles/124003.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
physicochemical parameter
river waters
Water Quality
WQI
Morava e Binçës
Opis:
The quality of surface waters is being impacted by the anthropogenic and natural pollution, thus limiting the usage of this water for drinking, industry, agriculture, recreation and other purposes. The water quality indices are intended to provide a single value for the water quality of a source or a stream that reduces the large amount of parameters in a simpler expression and enables an easy interpretation of the monitoring data. During 2017, seventeen physicochemical parameters were measured in spring, summer, autumn and winter, in five locations along the Morava e Binçës River in Kosovo. For the assessment we employed the Water Quality Index (WQI) which uses the physicochemical parameters for the evaluation of the water quality. The findings of this study ascertain that MB1 station had the best quality with a value of WQI 88 and is classified in the Good Category, whereas the lowest quality of water was found on in MB4 station with a value of WQI 65 and it is thus classified in the Fair Category. Finally, the average WQI was calculated for the entire measurement period and it resulted in a value of 77.60 indicating that the Morava e Binçës River waters belong to the Fair Category.
Źródło:
Journal of Ecological Engineering; 2018, 19, 6; 104-112
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of Physicochemical and Bacteriological Quality of Treated Wastewater by the New Aourir Plant (Southwestern of Morocco) Using Activated Sludge Technology in a Semi-Arid Region
Autorzy:
Hajji, Sara
Ait Alla, Aicha
Noureddine, Slimani
Haddad, Mohamed Ben
Moukrim, Abdellatif
Powiązania:
https://bibliotekanauki.pl/articles/1838386.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wastewater
Morocco
physicochemical parameter
activated sludge
Aourir
bacteriological parameter
treatment plant
Opis:
In order to use the purified wastewater for the irrigation of a golf course in the Taghazout area (Southwestern of Morocco), this study was conducted to evaluate the physicochemical and bacteriological quality of the treated wastewater in the new Aourir plant (Activated Sludge technology). In order to achieve these objectives, three types of water were analyzed: raw water (RW), biologically treated water (BTW) and water treated by ultraviolet radiation (UV-TW). The physicochemical parameters analyzed were Temperature, pH, Electrical Conductivity (EC), Dissolved Oxygen (DO), Chemical Oxygen Demand (COD), five-day Biological Oxygen Demand (BOD5), Total Suspended Solids (SS), Nitrate (NO3), and Orthophosphates (PO4). Otherwise, the analyzed biological parameters are Total Coliforms (TC), Fecal Coliforms (FC), Escherichia coli (E. coli), and Fecal Streptococci (FS). The physicochemical parameters showed that temperature is always lower than 30°C, the pH is close to neutrality and a strong fluctuation of the high electrical conductivity (2700 μS/cm) occurs in UV-TW. At all stages of wastewater treatment, COD, BOD5, SS, NO3 and PO4 were below the limit values recommended by Moroccan standards. The bacteriological results showed a high level of bacterial contamination in RW and BTW, but in UV-TW the loads did not exceed 3 log10. The average loads of TC, FC, E. coli and FC in UV-TW were 2.13, 1.67, 1.77, and 2 (log10 CFU/100ml) respectively. Activated sludge treatment combined with UV has demonstrated sufficient quality to reuse treated water in irrigation; however, the UV treatment requires control to avoid any effect on the microbiological and physicochemical quality of green spaces and groundwater.
Źródło:
Journal of Ecological Engineering; 2021, 22, 6; 83-98
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Long-term cyanobacterial dynamics as related to physicochemical water parameters in a restored urban lake
Autorzy:
Zebek, E.
Powiązania:
https://bibliotekanauki.pl/articles/1189822.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie / Polskie Towarzystwo Magnezologiczne im. Prof. Juliana Aleksandrowicza
Tematy:
Cyanoprokaryota
dynamics
physicochemical parameter
water parameter
urban lake
lake
restoration
nutrient
Opis:
The aim of this study has been to determine the response of cyanobacteria to the lake protection and restoration measures implemented in the littoral zone of an urban lake called Jeziorak Mały. The first investigations were conducted in 1996 and were resumed in 1997-2003, 2005 and 2013, following the installation of a separator and the creation of stone accumulation sites. Long-term changes in phytoplankton cyanobacterial proportions, abundance and biomass were analyzed in relation to environmental conditions at the sites in the littoral zone (S – separator pipes, K – sites with stones and R – sites with macrophytes). Relationships between cyanobacteria and water chemistry variables were analyzed by calculating the Spearman’s rank correlation coefficient, and then with canonical correspondence analysis (RDA). The results provided evidence that water temperature, total nitrogen and iron concentration (S, R), but also PO43- in spring (S,K) were the principal factors affecting cyanobacterial development. There was a significant decrease in the share, abundance and biomass of cyanobacteria coinciding with a decrease in conductivity and PO43- following the onset of lake restoration efforts. Changes in dominant species from the ones typical in hypertrophic lakes to those typically found in eutrophic lakes took place during the research. The modifications indicated a strong initial response of cynaobacteria to the restoration measures, but the situation stabilized in 2013, when cyanobacteria returned to their previous average levels. This suggests that the introduction of lake restortation measures contributed to the lake’s improved water quality and they should be retained for efficient lake management in the future.
Źródło:
Journal of Elementology; 2016, 21, 1; 269-282
1644-2296
Pojawia się w:
Journal of Elementology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Long-term cyanobacterial dynamics as related to physicochemical water parameters in a restored urban lake
Autorzy:
Zebek, E.
Powiązania:
https://bibliotekanauki.pl/articles/16004.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie / Polskie Towarzystwo Magnezologiczne im. Prof. Juliana Aleksandrowicza
Tematy:
Cyanoprokaryota
dynamics
physicochemical parameter
water parameter
urban lake
lake
restoration
nutrient
Opis:
The aim of this study has been to determine the response of cyanobacteria to the lake protection and restoration measures implemented in the littoral zone of an urban lake called Jeziorak Mały. The first investigations were conducted in 1996 and were resumed in 1997-2003, 2005 and 2013, following the installation of a separator and the creation of stone accumulation sites. Long-term changes in phytoplankton cyanobacterial proportions, abundance and biomass were analyzed in relation to environmental conditions at the sites in the littoral zone (S – separator pipes, K – sites with stones and R – sites with macrophytes). Relationships between cyanobacteria and water chemistry variables were analyzed by calculating the Spearman’s rank correlation coefficient, and then with canonical correspondence analysis (RDA). The results provided evidence that water temperature, total nitrogen and iron concentration (S, R), but also PO43- in spring (S,K) were the principal factors affecting cyanobacterial development. There was a significant decrease in the share, abundance and biomass of cyanobacteria coinciding with a decrease in conductivity and PO43- following the onset of lake restoration efforts. Changes in dominant species from the ones typical in hypertrophic lakes to those typically found in eutrophic lakes took place during the research. The modifications indicated a strong initial response of cynaobacteria to the restoration measures, but the situation stabilized in 2013, when cyanobacteria returned to their previous average levels. This suggests that the introduction of lake restortation measures contributed to the lake’s improved water quality and they should be retained for efficient lake management in the future.
Źródło:
Journal of Elementology; 2016, 21, 1
1644-2296
Pojawia się w:
Journal of Elementology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of Physicochemical and Bacteriological Quality of Treated Wastewater by the New Aourir Plant (Southwestern of Morocco) Using Activated Sludge Technology in a Semi-Arid Region
Autorzy:
Hajji, Sara
Ait Alla, Aicha
Noureddine, Slimani
Haddad, Mohamed Ben
Moukrim, Abdellatif
Powiązania:
https://bibliotekanauki.pl/articles/1838277.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wastewater
Morocco
physicochemical parameter
activated sludge
Aourir
bacteriological parameter
treatment plant
Opis:
In order to use the purified wastewater for the irrigation of a golf course in the Taghazout area (Southwestern of Morocco), this study was conducted to evaluate the physicochemical and bacteriological quality of the treated wastewater in the new Aourir plant (Activated Sludge technology). In order to achieve these objectives, three types of water were analyzed: raw water (RW), biologically treated water (BTW) and water treated by ultraviolet radiation (UV-TW). The physicochemical parameters analyzed were Temperature, pH, Electrical Conductivity (EC), Dissolved Oxygen (DO), Chemical Oxygen Demand (COD), five-day Biological Oxygen Demand (BOD5), Total Suspended Solids (SS), Nitrate (NO3), and Orthophosphates (PO4). Otherwise, the analyzed biological parameters are Total Coliforms (TC), Fecal Coliforms (FC), Escherichia coli (E. coli), and Fecal Streptococci (FS). The physicochemical parameters showed that temperature is always lower than 30°C, the pH is close to neutrality and a strong fluctuation of the high electrical conductivity (2700 μS/cm) occurs in UV-TW. At all stages of wastewater treatment, COD, BOD5, SS, NO3 and PO4 were below the limit values recommended by Moroccan standards. The bacteriological results showed a high level of bacterial contamination in RW and BTW, but in UV-TW the loads did not exceed 3 log10. The average loads of TC, FC, E. coli and FC in UV-TW were 2.13, 1.67, 1.77, and 2 (log10 CFU/100ml) respectively. Activated sludge treatment combined with UV has demonstrated sufficient quality to reuse treated water in irrigation; however, the UV treatment requires control to avoid any effect on the microbiological and physicochemical quality of green spaces and groundwater.
Źródło:
Journal of Ecological Engineering; 2021, 22, 6; 83-98
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of flow and damming on water quality of the mountain Raba River (southern Poland) : long-term studies
Wpływ przepływu i piętrzenia na jakość wody górskiej rzeki Raby (południowa Polska) : badania wieloletnie
Autorzy:
Szarek-Gwiazda, Ewa
Gwiazda, Robert
Powiązania:
https://bibliotekanauki.pl/articles/2173790.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
flow
physicochemical parameter
Carpathian river
impact of dam
przepływy
parametry fizykochemiczne
Raba
zapora
Opis:
Climate change, manifested by long term periods of drought to heavy rainfall, may remarkably modify river flow regimes. We hypothesize that flow prevailing in a given year determines water chemistry of the Carpathian Raba River above and below Dobczyce Reservoir (southern Poland), used for drinking purposes. Based on the mean annual river flow for years 1991-2017, hydrologically dry (HD), hydrologically average (HA) and hydrologically wet (HW) years were distinguished. We found significant differences in the values of most studied physicochemical parameters of river water above and below the reservoir between studied hydrological years (for a period of April‒November). In HD years, the water above the dam had significantly higher temperature and values of conductivity (point pollution source, groundwater inflow), while lower ones of nutrients NO3- and P-tot (diffuse pollution) compared to those in HA and/or HW years. The best GLM models for mean monthly flows above and below the dam include 3-5 factors among which conductivity and NO3 concentration were always present. The reservoir in different ways influences the water chemistry below the dam in HD, HA and HW years. The impact of flow on the water quality in hydrologically varied years is discussed. The obtained results are important for appropriate management in catchment basins of mountain rivers and the protection of dam reservoirs against the eutrophication processes in changing climate and flow regime.
Zmiany klimatu, przejawiające się długotrwałymi okresami suszy lub obfitych opadów, mogą znacząco zmienić roczny reżim przepływów. Stawiamy hipotezę, że przepływ dominujący w danym roku determinuje chemizm wody rzeki górskiej. Celem pracy było określenie (1) różnic w chemizmie wody górskiej rzeki pomiędzy latami hydrologicznie suchymi (HD), przeciętnymi (HA) i mokrymi (HW), (2) wpływu zbiornika zaporowego na chemię wody odpływającej rzeki w różnych latach hydrologicznych, (3) parametrów fizyczno-chemicznych związanych ze średnim miesięcznym przepływem wody w latach HD, HA i HW. Badania prowadzono w karpackiej rzece Rabie powyżej i poniżej Zbiornika Dobczyckiego w południowej Polsce. W oparciu o średni roczny przepływ rzeki z wielolecia 1991–2017 wyróżniono lata HD, HA i HW. Przeanalizowano zmiany parametrów fizyczno- chemicznych wody (temperatura, przewodność elektrolityczna, pH, tlen rozpuszczony, nasycenie tlenem, BZT5, biogeny: NO3-, NH4+, P-tot) pobieranych co miesiąc w okresie kwiecień–listopad. Stwierdziliśmy istotne różnice w chemizmie wody rzeki między badanymi latami hydrologicznymi. W latach HD wody powyżej zbiornika miały istotnie wyższą temperaturę i wartości przewodności elektrolitycznej, natomiast niższe wartości biogenów NO3- i P-tot (zanieczyszczenie obszarowe) w porównaniu do lat HA i/lub HW. Zbiornik w różny sposób kształtował skład chemiczny wody rzeki poniżej zapory w latach HD, HA i HW. Najlepsze modele GLM dla średnich miesięcznych przepływów obejmowały 3–5 czynników, wśród których zawsze występowały przewodność elektrolityczna i stężenia NO3-. Uzyskane wyniki mają istotne znaczenie dla właściwego gospodarowania w zlewniach rzek górskich i ochrony zbiorników zaporowych przed procesami eutrofizacji.
Źródło:
Archives of Environmental Protection; 2022, 48, 1; 31--40
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Functional properties of neem oil as potential feedstock for biodiesel production
Autorzy:
Bhandare, P.
Naik, G.R.
Powiązania:
https://bibliotekanauki.pl/articles/11717.pdf
Data publikacji:
2015
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
functional property
neem
seed oil
Azadirachta indica
feedstock
biodiesel production
physicochemical parameter
Opis:
Fossil fuel resources are decreasing daily while biodiesel fuels are attracting increasing attention worldwide as blending components or direct replacements for diesel fuel in vehicle engines. In this experiment the seed oils of 30 Neem (Azadirachta indica. A. juss) biotypes were screened and evaluated for their physio-chemical parameters for oil content, biodiesel yield, density, viscosity, iodine value , free fatty acid and saponification value. Hence the neem seed oil tested in this current study could be the potential sources of raw material for biodiesel production.
Źródło:
International Letters of Natural Sciences; 2015, 07
2300-9675
Pojawia się w:
International Letters of Natural Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studies on some physico-chemical parameters of cyanophycean members and correlation coefficient of eutrophic ponds in Chidambaram, Tamil Nadu, India
Autorzy:
Elayaraj, B.
Selvaraju, M.
Powiązania:
https://bibliotekanauki.pl/articles/10938.pdf
Data publikacji:
2014
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
physicochemical parameter
phytoplankton
correlation coefficient
eutrophic pond
pond
Chidambaram town
Tamil Nadu
India
Opis:
The present study deals with the statistical analysis of physico-chemical parameters and cyanophycean members of two pond water quality of Chidambaram, Cuddalore district (Tamil Nadu). The qualities of pond water were analyzed for six months. Eleven important parameters were included in statistical analysis. The qualities of pond water have been assessed by calculating mean, standard deviation and correlation coefficient. Correlation studies of hydrobiology with physico-chemical parameters revealed that the relationship between phytoplankton density in general and that of the specific groups are highly complex and often controlled by interactions of different factors. In the both pond water the correlation coefficient test revealed that cyanophycean members positively correlated with temperature, pH, CO2, alkalinity, hardness, nitrate, BOD and COD at 1 % and 5 % level significant, where as it is negatively correlated with acidity and dissolved oxygen. In the present study it can be concluded that the cyanophycean members are highly tolerant organisms. They prefer to grow at higher temperatures and in highly alkaline, BOD and COD waters. Hence they can with stand high levels of contaminated waters of Thillai Kali Kovil pond, when compared to Ilamiyakkinar Kovil pond.
Źródło:
International Letters of Natural Sciences; 2014, 11, 2
2300-9675
Pojawia się w:
International Letters of Natural Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of physicochemical parameters on zooplankton in the brackish, coastal Vistula Lagoon
Autorzy:
Paturej, E.
Gutkowska, A.
Koszalka, J.
Bowszys, M.
Powiązania:
https://bibliotekanauki.pl/articles/48536.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Instytut Oceanologii PAN
Tematy:
physicochemical parameter
zooplankton
brackish water
Vistula Lagoon
environment condition
canonical correspondence analysis
temperature
salinity gradient
Opis:
This paper analyzes whether physicochemical properties significantly influence the occurrence of zooplankton in a brackish reservoir. The studies were carried out on the Vistula Lagoon in August and September from 2006 to 2009 at 32 research sites. The environmental conditions in the Vistula Lagoon varied widely. At the time of the investigation, 17 species of rotifers, six species of Cladocera, and ten species of Copepoda were noted, and the total density of plankton fauna ranged from 145 to 765 ind. dm3. Statistical analysis demonstrated a significant correlation between the occurrence of some zooplankton species and certain environmental parameters, whereas the sampling sites were grouped according to study years. The zooplankton systems recorded at the research sites in 2006 constitute the most disparate group. Thus, it can be concluded that physicochemical properties might significantly impact both individual species (depending on their environmental demands) and entire zooplankton clusters.
Źródło:
Oceanologia; 2017, 59, 1
0078-3234
Pojawia się w:
Oceanologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The occurrence of Stagnicola turricula (Held, 1836) (Gastropoda: Pulmonata: Lymnaeidae) in Upper Silesia
Autorzy:
Skowronska-Ochmann, K.
Lewin, I.
Cuber, P.
Powiązania:
https://bibliotekanauki.pl/articles/83313.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Mikołaja Kopernika. Wydział Biologii i Ochrony Środowiska. Stowarzyszenie Malakologów Polskich
Tematy:
occurrence
Stagnicola turricula
Gastropoda
Pulmonata
Lymnaeidae
Upper Silesian region
water body
physicochemical parameter
hydrobiology
Źródło:
Folia Malacologica; 2012, 20, 1
1506-7629
Pojawia się w:
Folia Malacologica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Seasonal influence of physico-chemical parameters on phytoplankton diversity, community structure and abundance at Parangipettai coastal waters, Bay of Bengal, South East Coast of India
Autorzy:
Vajravelu, M.
Martin, Y.
Ayyappan, S.
Mayakrishnan, M.
Powiązania:
https://bibliotekanauki.pl/articles/47903.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Instytut Oceanologii PAN
Tematy:
phytoplankton
community structure
abundance
seasonal variation
nutrient dynamics
physicochemical parameter
Parangipettai
coastal water
Bengal Bay
India coast
Źródło:
Oceanologia; 2018, 60, 2
0078-3234
Pojawia się w:
Oceanologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Potential effects of abiotic factors on the abundance and distribution of the plankton in the Western Harbour, South-Eastern Mediterranean Sea, Egypt
Autorzy:
Heneash, A.M.M.
Tadrose, H.R.Z.
Hussein, M.M.A.
Hamdona, S.K.
Abdel-Aziz, N.
Gharib, S.M.
Powiązania:
https://bibliotekanauki.pl/articles/48656.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Instytut Oceanologii PAN
Tematy:
plankton
zooplankton
distribution
Western Harbour
Mediterranean Sea
Egypt
abiotic factor
potential effect
abundance
physicochemical parameter
seasonal dynamics
Źródło:
Oceanologia; 2015, 57, 1
0078-3234
Pojawia się w:
Oceanologia
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies