Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "out-patient" wg kryterium: Wszystkie pola


Wyświetlanie 1-2 z 2
Tytuł:
Yeasts isolated from frequently in-patients and out-patients
Autorzy:
Dynowska, M.
Ejdys, E.
Biedunkiewicz, A.
Kubiak, D.
Sucharzewska, E.
Roslan, M.
Powiązania:
https://bibliotekanauki.pl/articles/5588.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Parazytologiczne
Tematy:
yeast
isolation
in-patient
out-patient
patient
fluconazole
nystatin
nosocomial infection
Opis:
The paper is a part of a general mycological monitoring study of nosocomial infections. Differences in the species composition and drug resistance of fungi isolated from in-patients and out-patients prompted an analysis of this topic. The studies were conducted with fungi from the collection of the Department of Mycology, University of Warmia and Mazury in Olsztyn, that were isolated from the oral cavity, sputum, bronchoscopic fluid, anus and skin from 100 in-patients and 100 out-patients. Laboratory analyses, including species categorization of fungi, were performed according to routine mycological diagnostics. Drug sensitivity to fluconazole and nystatin was tested with the disc diffusion method. In the group of in-patients, a wider taxonomic diversity of fungi (12 species) was found in comparison with the out-patients (7 species) and 31 cases of multifocal infections were recorded, while in the second group the number of the latter was only six. In all patients, C. albicans were predominant, constituting the largest proportion in focal infections in all patients and in multifocal infections in the in-patients. In the latter, over a half of the examined individuals were resistant to fluconazole (C. glabrata and C. krusei – 80%, C. tropicalis and S. capsularis – 60%, C. guilliermondii – 50%) and nystatin (T. beigelii – 80%, C. krusei and C. tropicalis – 50%). Substantially lower drug resistance of fungi was recorded in the out-patients. The hospital environment is an abundant reservoir of different fungal species with significantly greater expansiveness and aggressiveness compared to the environment outside a hospital.
Źródło:
Annals of Parasitology; 2014, 60, 3
0043-5163
Pojawia się w:
Annals of Parasitology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The assessment of the ionizing radiation dose received by patients during some diagnostic X-ray examinations carried out on the basis of the working procedures in the health care entities
Autorzy:
Bekas, M.
Waniewska, E.
Wardzinski, A.
Wieprzowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/874288.pdf
Data publikacji:
2017
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
assessment
ionizing radiation
radiation dose
patient
diagnostic method
X-ray method
radiation exposure
working procedure
health care
human health
health risk
Opis:
Background. X-ray examination is a popular and universally used injury and disease diagnostic method. A distinctive X ray examination feature is that it can be done quickly which is extremely important in case of the need for rapid diagnosis of patients in life threatening condition. Another advantage of the X-ray examinations is also relatively low cost of carry. However, X-ray examination involve adverse health effects. During the examination the patient is subjected to ionizing radiation that might have impact on his health. Objective. The aim of this study has been to determine and assess the size of the entrance surface doses (ESD) received by patients during selected X-ray examinations performed on the basis of the medical working procedures available in healthcare entities in Masovian Voivodeship in Poland. Materials and Method. The examinations were conducted for 71 X-ray units located in the Masovian Voivodeship. Measurements of doses received by the patients were based on our own validated test methods. Results. It was found that the range applied to the high voltage in healthcare entities does not always coincide with the values specified in the standard procedures. It was found in the skull projection radiography AP and LAT that the recorded values were from range 60 to 82 kV (the average value of 74 kV) while in accordance with a standard procedure they should be in the range from 65 to 75 kV. Only in case of cervical spine radiography in the AP projection, the LAT exposure conditions were matching with the standard obligatory procedures in Poland. The consequence of selecting exposure conditions are significant differences in the size of the doses the patient receive during the same medical procedures. The greatest range of ESD doses was found during radiography of the thoracic spine in the projection AP and LAT. The projection LAT measured values were in the range of 523 to 10550 μGy (average value 2175 μGy). Conclusions. It is necessary to update immediately the standard procedures and to develop detailed guidelines for the preparation of working procedures in X-ray rooms.
Wprowadzenie. Badania rentgenowskie są powszechnie stosowaną metodą diagnozowania urazów i schorzeń występujących u pacjentów. Największą zaletą tych badań jest szybkość ich wykonania, co jest niezwykle istotne w przypadku konieczności postawienia szybkiej diagnozy medycznej u pacjentów w ciężkim stanie zagrażającym ich życiu. Badania rentgenowskie niosą jednakże ze sobą także negatywne skutki zdrowotne. W trakcie ich przeprowadzania pacjent poddany jest działaniu promieniowania jonizującego, które nie jest obojętne dla zdrowia. Cel. Celem badań było oszacowanie wielkości wejściowej dawki powierzchniowej (ESD) jaką otrzymują pacjenci podczas wybranych badań rentgenowskich przeprowadzonych w oparciu o procedury robocze obowiązujące w placówkach ochrony zdrowia na terenie województwa mazowieckiego. Materiał i metody. Zbadano 71 aparatów rentgenowskich wykorzystywanych w placówkach ochrony zdrowia na terenie województwa mazowieckiego. Pomiary dawek otrzymywanych przez pacjentów podczas badań rentgenowskich przeprowadzono własnymi zwalidowanymi metodami badawczymi. Wyniki. Stwierdzono, iż zakres wartości wysokiego napięcia dobieranego przez personel medyczny na aparatach rentgenowskich w placówkach ochrony zdrowia nie zawsze pokrywa się z wartościami określonymi w procedurach wzorcowych. Stwierdzono, iż w radiografii czaszki w projekcji AP i LAT wartość wysokiego napięcia była od 60 do 82 kV (wartość średnia 74 kV), zaś zgodnie z procedurą wzorcową powinny mieścić się w zakresie od 65 do 75 kV. Najlepszą zgodność pomiędzy wartościami wysokiego napięcia stosowanymi w pracowniach rtg a tymi określonymi w procedurach wzorcowych obowiązujących w Polsce stwierdzono w przypadku radiografii kręgosłupa szyjnego. Konsekwencją tak dobieranych warunków ekspozycji są znaczące różnice w wielkości dawek promieniowania otrzymywanych przez pacjentów dla tych samych procedur medycznych. Największą rozpiętość dawek ESD stwierdzono w trakcie radiografii kręgosłupa piersiowego w projekcji AP oraz LAT. W projekcji LAT zmierzone wartości były w przedziale od 523 do 10550 μGy (wartość średnia 2175 μGy). Wnioski. Niezbędne jest jak najszybsze uaktualnienie procedur wzorcowych oraz opracowanie szczegółowych wytycznych dotyczących przygotowywania procedur roboczych w pracowniach rentgenowskich.
Źródło:
Roczniki Państwowego Zakładu Higieny; 2017, 68, 1
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies