Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "passivation" wg kryterium: Temat


Wyświetlanie 1-13 z 13
Tytuł:
Characterization of Long-Term Corrosion Performance of Ti15Mo Alloy in Saline Solution
Autorzy:
Szklarska, M.
Łosiewicz, B.
Dercz, G.
Zubko, M.
Albrecht, R.
Stróż, D.
Powiązania:
https://bibliotekanauki.pl/articles/357034.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
biomaterial
corrosion resistance
passivation
structure
titanium alloys
Opis:
The Ti15Mo alloy has been studied towards long-term corrosion performance in saline solution at 37°C using electrochemical impedance spectroscopy. The physical and chemical characterization of the material were also investigated. The as-received Ti15Mo alloy exhibits a single β-phase structure. The thickness of single-layer structured oxide presented on its surface is ~4 nm. Impedance measurements revealed that the Ti15Mo alloy is characterized by spontaneous passivation in the solution containing chloride ions and formation of a double-layer structured oxide composed of a dense interlayer being the barrier layer against corrosion and porous outer layer. The thi ckness of this oxide layer, estimated based on the impedance data increases up to ~6 nm during 78 days of exposure. The obs erved fall in value of the log|Z|f=0.01 Hz indicates a decrease in pitting corrosion resistance of Ti15Mo alloy in saline solution along with the immersion time. The detailed EIS study on the kinetics and mechanism of corrosion process and the capacitive behavior of the Ti15Mo electrode | passive layer | saline solution system was based on the concept of equivalent electrical circuit with respect to the physical meaning of the applied circuit elements. Potentiodynamic studies up to 9 V vs. SCE and SEM analysis show no presence of pitting corrosion what indicates that the Ti15Mo alloy is promising biomaterial to long-term medical applications.
Źródło:
Archives of Metallurgy and Materials; 2019, 64, 2; 773-778
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie kinetyki procesu pasywacji powierzchni stali nierdzewnych na potrzeby modelowania tribokorozji węzłów ślizgowych
The evaluation of the kinetics of the process of passivation phenomena on a stainless steel surface for the tribocorrosion of sliding pairs
Autorzy:
Stachowiak, A.
Zwierzycki, W.
Powiązania:
https://bibliotekanauki.pl/articles/188107.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
tribokorozja
pasywacja
model obliczeniowy
tribocorrosion
passivation
computational model
Opis:
W artykule przedstawiono wyniki badań procesu pasywacji stali AISI 420, AISI 430 i AISI 304 w 0,5M roztworze H2SO4. Eksperyment realizowano na dwóch etapach. W trakcie pierwszego etapu przez 15 minut polaryzowano powierzchnię próbki potencjałem katodowym (około 0,3 V niższym od potencjału stacjonarnego). Na drugim etapie w sposób skokowy zwiększano potencjał do wartości odpowiadającej początkowi zakresu pasywnego i monitorowano zmiany natężenia prądu (około 20 pomiarów w ciągu sekundy). Zgodnie z modelem wzrostu warstw pasywnych (zaproponowanym przez S. Mischlera) uzyskane wyniki aproksymowano charakterystykami liniowymi w układzie (q-1)-log(i) (q - ładunek przepływający w badanym układzie, i - gęstość natężenia prądu pasywacji). Stałe materiałowe wyznaczone w wyniki aproksymacji wykorzystano do prognozowania tribokorozji w węźle ślizgowym typu pin-on-disc.
The article presents the results of passivation process evaluation of different steels - AISI 420, AISI 430 and AISI 304 in a 0.5M solution of H2SO4. The experiment was carried out in two stages. In the first stage for 15 minutes, the surface of sample was polarised with cathodic potential (roughly 0.3V lower than stationary potential). In the second stage, the potential was increased in stroke way till the value equal to the starting point of passive range and the changes of current intensity was monitored (roughly 20 measurements per second). According to film growth model (proposed by S. Mischler) the obtained results were approximated with linear characteristics in (q-1)-log(i) system (i - density of passivation current intensity, q - charge running in evaluated system). Material constans evaluated after approximation were used for tribocorrosion forecast in pin-on-disc sliding pairs.
Źródło:
Tribologia; 2010, 5; 305-313
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Warstwy tlenkowe na tytanie otrzymane metodą anodowania w kwasie siarkowym
Oxide layers on titanium obtained by anodization in sulphuric acid
Autorzy:
Wilk, Michał
Klimek, Leszek
Powiązania:
https://bibliotekanauki.pl/articles/211466.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Obróbki Plastycznej
Tematy:
tytan
ceramika stomatologiczna
anodowanie
pasywacja
titanium
dental ceramics
anodization
passivation
Opis:
Komercyjnie czysty tytan stanowi jeden z czołowych materiałów biointegrujący się z tkankami przyzębia, co wykorzystuje się na co dzień w protetyce stomatologicznej. Wysoka reaktywność z tlenem, niska rozszerzalność termiczna tytanu i zjawisko pasywacji utrudniają obróbkę tytanu, a w szczególności połączenie z materiałami licującymi, jak ceramika stomatologiczna. Analizując obecne w piśmiennictwie doniesienia, opisujące zarówno pozytywny, jak i negatywny wpływ warstwy tlenkowej na połączenie tytan–ceramika, podjęto próbę elektrochemicznego wytworzenia powłok pasywnych z kąpieli zawierającej H2SO4 na komercyjnie czystym tytanie, mogącym stanowić podbudowę koron i mostów protetycznych. Materiały i metody. Tytanowe walce Grade 2 (śr. 20 mm i wys. 5 mm) szlifowano i wypolerowano. Skład stopu określono metodą rentgenowskiej analizy fluorescencyjnej. Próbki podzielono na 3 grupy i poddano oksydacji anodowej w 1M kwasie siarkowym przy stałych napięciach: 120V, 160V, 200V, t=1min. Warstwy tlenkowe poddano badaniu dyfrakcji rentgenowskiej, analizie składu chemicznego oraz obserwacji SEM. Wyniki. Otrzymano warstwy grubości 1 μm do 7,1 μm. W warstwie anodowanej, oprócz tlenku tytanu, występują domieszki siarki. Tezy. Wybór napięcia anodowania wpływa na grubość otrzymanych warstw, co determinuje możliwość praktycznego zastosowania. Warstwy ponad 1 μm mogą ulegać łuszczeniu i pękaniu. Co więcej, zbyt cienkie powłoki wykazują ubytki i nie pokrywają całej powierzchni metalu. Wnioski. Zwiększenie napięcie reakcji nie tylko wpływa na pogrubienie warstwy, ale również na porowatość. Możliwość kontrolowania średnicy porowatości przyłożonym napięciem anodowania może zapewnić poprawę mikroretencji ceramiki stomatologicznej. Biorąc pod uwagę grubość wytworzonych warstw, największe zalety prak-tyczne wydają się mieć powłoki wytworzone pod napięciem 120V.
Commercially pure titanium is the leading biointegrating material, which is used in everyday dental prosthetics. High reactivity with oxygen, low thermal expansion and passivation impede titanium processing, especially bonding with veneering materials like dental ceramics. After analyzing the literature with view to positive and negative impact of titanium oxide layer on boning strength between titanium and dental ceramics, an attempt was made to fabricate the anodic layers by means of electrochemical oxidation in 1M sulphuric acid on CP-Ti which will subsequently be used as a framework of PFM dental prosthesis. Materials and methods. Grade 2 Titanium cylinders (20 mm diameter, 5 mm high) were grinded and polished. Chemical composition was determined by X-ray fluorescent analysis. Samples were divided into 3 groups and oxidized in 1M sulphuric acid in DC voltage: 120V, 160V, 200V, t=1min. Oxide layers undergone X-ray diffraction examina-tion, chemical composition analysis and SEM observations. Results. Layers of 1 μm to 7,1μm were obtained. Layers is composed not only of titanium oxide but also contains sulphur. Thesis: Selection of anodizing voltage affects layer thickness thus determinates its practical application. Layers over 1μm thick may crack and flake off, furthermore, too thin layers show surface loss and do not cover the entire surface of titanium. Findings: Increased voltage not only results in layer thickening but also affects porosity. Pore size control may contribute to enhanced porcelain microretention. Considering layers thickness and practical application, 120V layers seem to have the most advantages.
Źródło:
Obróbka Plastyczna Metali; 2019, 30, 2; 135-144
0867-2628
Pojawia się w:
Obróbka Plastyczna Metali
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative corrosion studies of 2205 duplex steel after electropolishing and passivation in Ringer’s solution
Autorzy:
Rokosz, Krzysztof
Hryniewicz, Tadeusz
Solecki, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/1178066.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
electropolishing
passivation
pitting corrosion
potentiodynamic corrosion measurements
stainless steel duplex 2205
Opis:
In present work, the results of corrosion analysis of pitting and general corrosion of austenitic duplex 2205 (EN 1.4462) stainless steel in Ringer's solution, are presented. The corrosion rate was studied using potentiodynamic polarisation method by means of the ATLAS 98 potentiostat with POL 98 software. For these measurements the platinum EPT-101 and calomel reference EK-101P electrodes were used. For each run, the electrolytic cell made of glass was used, containing up to 500 ml of the electrolyte. The specimens used for the studies were obtained from a cold-rolled sheet of steel in three forms: as received (without any pretreatment), after abrasive polishing, and after electrochemical polishing. Some of them were passivated for 15 and 30 minutes, respectively, in 20% HNO3 by volume. The study results show clearly that the samples of duplex 2205 stainless steels after electropolishing and passivation for 15 minutes in 20% HNO3 by volume revealed the highest corrosion resistance.
Źródło:
World Scientific News; 2018, 95; 167-181
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The possibility of implementation of spent iron catalyst for ammonia synthesis
Autorzy:
Ekiert, E.A.
Pelka, R.
Lubkowski, K.
Arabczyk, W.
Powiązania:
https://bibliotekanauki.pl/articles/779200.pdf
Data publikacji:
2009
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
odpadowy katalizator żelazowy
pasywacja
nawęglanie
spent iron catalyst
passivation
carburization
Opis:
An iron catalyst used in the ammonia synthesis is pyrophoric in its reactive, reduced form. Before further use the catalyst has to be passivated. Results of the research on the iron catalyst - its passivation, re-use as a catalyst in other processes and implementation as a substrate to obtain new nanocrystalline materials have been presented in the paper.
Źródło:
Polish Journal of Chemical Technology; 2009, 11, 1; 28-33
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ pasywacji na odporność korozyjną stopu NiTi
Influence of passivation on corrosion resistance of NiTi alloy
Autorzy:
Kaczmarek, M.
Powiązania:
https://bibliotekanauki.pl/articles/284748.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
biomateriały
stopy z pamięcią kształtu
odporność korozyjna
pasywacja
biomaterials
shape memory alloys
corrosion resistance
passivation
Opis:
Celem przeprowadzonych badań było określenie wpływu różnych metod pasywacji powierzchni stopu NiTi na odporność korozyjną. Analizowano dwa warianty pasywacji powierzchni: chemiczną oraz elektrochemiczną. Dla każdego z zaproponowanych wariantów zastosowano różne kąpiele oraz oceniano wpływ parametrów procesów na odporność korozyjną.
The aim of the research was determination of influence of different passivation methods of NiTi alloy on corrosion resistance. Two variants of passivation were analyzed: chemical and electrochemical. For each of the proposed variant different baths and parameters were applied.
Źródło:
Engineering of Biomaterials; 2010, 13, no. 99-101; 32-34
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody elektrochemiczne obróbki stali używanych w transporcie
Electrochemical methods of processing of steels used in transport
Autorzy:
Kułakowski, M.
Rokosz, K.
Powiązania:
https://bibliotekanauki.pl/articles/312241.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
trawienie
polerowanie elektrochemiczne
pasywowanie
nanowarstwy pasywne
stale nierdzewne
etching
electropolishing
passivation
passive nanolayers
stainless steels
Opis:
Stale nierdzewne zawierają minimum 50% żelaza i powyżej 10,5% chromu, co daje im odporność korozyjną zbliżoną do chromu. Z tego względu są szeroko stosowane do budowy zbiorników i cystern do przewozu środków stężonych chemicznych i płynów spożywczych. Ich odporność korozyjna wynika z pasywnych nanowarstw wzbogaconych w związki chromu, które mogą być uzyskiwane między innymi poprzez polerowanie elektrochemiczne przy niskich i wysokich gęstościach prądów oraz z użyciem pola magnetycznego, jak i pasywacji. W artykule przedstawiono również skład chemiczny dwóch warstw pasywnych otrzymanych na stopowej stali austenitycznej AISI 316L po standardowym polerowaniu elektrochemicznym (EP) oraz z użyciem pola magnetycznego (MEP), co pokazuje możliwości sterowania składem nanowarstwy pasywnej.
Stainless steel is more resistant to corrosion as carbon one and it is increasingly used in transportation as construction materials for cisterns and tanks transporting chemicals and foodstuffs. Generally, under normal conditions on the surface of stainless steel is present a self-healing, passive layer that is responsible for the corrosion resistance of this material, but in most applications thicker and more reliable layers are required. Hence in this paper electrochemical methods of obtaining in controlling conditions passive layer and microsmothing of surface on stainless steel are presented. In addition, pickling methods, electrochemical methods of passivation, electropolishing (EP), high-current-density electropolishing (HDEP) and magnetoelectropolishing (MEP), in that article were desribed, too.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 7-8; 353-356
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The studies of corrosion resistance of AISI 316Ti SS in Ringer’s solution after electropolishing and passivation in nitric acid
Autorzy:
Rokosz, Krzysztof
Hryniewicz, Tadeusz
Solecki, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/1177846.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
AISI 316Ti/EN 1.4571
austenitic stainless steel
electropolishing
passivation
pitting corrosion
potentiodynamic corrosion measurements
Opis:
In present work, the continuation of general and pitting corrosion analysis of austenitic AISI 316Ti (EN 1.4571) stainless steel in Ringer's solution, is presented. The corrosion was studied by using the ATLAS 98 potentiostat with platinum EPT-101 and calomel reference EK-101P electrodes. The three types of specimens, i.e. as received (without any pretreatment), after abrasive mechanical polishing (MP), and after electrochemical polishing (EP), were used. The best pitting corrosion resistance was recorded for electropolished and passivated (in 20% vol. HNO3 for 30 minutes) surface, i.e. the pitting potential was equal to 761 mVSCE (855.4 ± 58.5 mVSCE), while the worst one was recorded for mechanically ground samples and the pitting corrosion potential was equal to 270 mVSCE (378.8 ± 60.3 mVSCE).
Źródło:
World Scientific News; 2018, 98; 46-60
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Influence of Passivation Type on Corrosion Resistance of Ti15Mo Alloy in Simulated Body Fluids
Wpływ rodzaju pasywacji powierzchni stopu Ti15Mo na jego odporność korozyjną w środowisku płynów ustrojowych
Autorzy:
Szklarska, M.
Dercz, G.
Rak, J.
Łosiewicz, B.
Simka, W.
Powiązania:
https://bibliotekanauki.pl/articles/353709.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
biomaterial
electrochemical impedance spectroscopy
corrosion resistance
passivation
titanium alloys
biomateriały
elektrochemiczna spektroskopia impedancyjna
odporność na korozję
pasywacja
stopy tytanu
Opis:
This work reports on determination of the influence of passivation type of Ti15wt.%Mo implant alloy surface on its corrosion resistance in simulated body fluids. The alloy under investigation was subjected to natural self-passivation in air, and forced passivation by autoclaving in steam, boiling in 30 % solution of H2O2, and electrochemical passivation in 0.9 % NaCl solution. Resistance of the passivated Ti15Mo alloy to pitting corrosion was studied at 37ºC in 0.9 % NaCl solution using open circuit potential method, anodic polarization curves, and electrochemical impedance spectroscopy (EIS). Comparative estimation of the determined parameters of corrosion resistance revealed that the obtained passive layers improve anticorrosive properties of the tested alloy. Surface of the alloy subjected to passivation in steam autoclave reveals the highest protection against pitting corrosion. Anodic potentiodynamic curves showed that the Ti15Mo alloy after different passivation types of the surface is characterized by a lack of susceptibility to pitting corrosion up to potential of 9 V. Based on the EIS investigations, the thickness of the formed oxide layers (TiO2, anatase) was determined to be in the range from 2.0 to 7.8 nm in dependence on the applied type of passivation. It was ascertained that electrochemical properties of the Ti15Mo alloy and possibility of its surface passivation using simple methods, make it an attractive material for use in biomedicine for long-term implants.
Praca dotyczy określenia wpływu rodzaju pasywacji powierzchni stopu Ti15%wag.Mo na jego odporność korozyjną w środowisku płynów ustrojowych. Badany stop poddano naturalnej samopasywacji w powietrzu oraz wymuszonej pasywacji w autoklawie parowym, w gotującym się 30 % roztworze H2O2 oraz elektrochemicznej pasywacji w 0,9 % roztworze NaCl. Odporność pasywowanego stopu Ti15Mo na korozję wżerową badano w temperaturze 37°C w roztworze 0,9 % NaCl metodą potencjału obwodu otwartego, krzywych polaryzacji anodowej oraz elektrochemicznej spektroskopii impedancyjnej (ESI). Ocena porównawcza wyznaczonych parametrów odporności korozyjnej wykazała, że wytworzone warstwy pasywne poprawiają właściwości antykorozyjne badanego stopu. Powierzchnia stopu poddana pasywacji w autoklawie parowym wykazuje najwyższą ochronę przed korozją wżerową. Anodowe krzywe potencjodynamiczne ujawniły, że stop Ti15Mo poddany różnym sposobom pasywacji powierzchni wykazuje brak podatności na korozję wżerową aż do potencjału wynoszącego 9 V. W oparciu o badania ESI wyznaczona została grubość otrzymanych warstw tlenkowych (TiO2, anataz), która w zależności od zastosowanego sposobu pasywacji mieściła się w zakresie od 2,0 do 7,8 nm. Stwierdzono, że właściwości elektrochemiczne stopu Ti15Mo oraz możliwość pasywowania jego powierzchni prostymi metodami, czynią go atrakcyjnym materiałem do zastosowań w biomedycynie na implanty długoterminowe.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 4; 2687-2694
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On real order passivity
Autorzy:
Gallegos, J. A.
Duarte-Mermoud, M. A.
Powiązania:
https://bibliotekanauki.pl/articles/200762.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
passivity
dissipativeness
adaptive
passivation
nonlinear mixed-order system
positive realness
control of nonlinear systems
pasywność
rozproszenie
adaptacja
pasywacja
Opis:
The aim of this paper is to show that a real order generalization of the dissipative concepts is a useful tool to determine the stability (in the Lyapunov and in the input-output sense) and to design control strategies not only for fractional order non-linear systems, but also for systems composed of integer and fractional order subsystems (mixed-order systems). In particular, the fractional control of integer order system (e.g. PI? control) can be formalized. The key point is that the gradations of dissipativeness, passivity and positive realness concepts are related among them. Passivating systems is used as a strategy to stabilize them, which is studied in the non-adaptive as well as in the adaptive case.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2019, 67, 3; 445-454
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania porównawcze odporności korozyjnej stopowej stali austenitycznej AISI 304L (EN 1.4307) po walcowaniu na zimno oraz po pasywowaniu w kwasie azotowym HNO3
Comparative studies of corrosion resistance of AISI 304L (EN 1.4307) austenitic stainless steel after cold rolling and passivation in nitric acid HNO3
Autorzy:
Rokosz, K.
Hryniewicz, T.
Solecki, G.
Dudek, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/313247.pdf
Data publikacji:
2015
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
korozja wżerowa
stal austenityczna AISI 304L
stal nierdzewna
pasywowanie
walcowanie na zimno
pitting corrosion
AISI 304L austenitic stainless steel
passivation
cold rolling
Opis:
Niniejszy artykuł przedstawia badanie porównawcze odporności korozyjnej austenitycznej stali stopowej AISI 304L (EN 1.4307). Wyniki badań ilustrują odporność na korozję wżerową stali po walcowaniu na zimno oraz pasywowaniu w różnych warunkach. Badania elektrochemiczne przeprowadzone były dla trzech grup próbek: po walcowaniu na zimno, oraz po walcowaniu na zimno i pasywowaniu w kwasie azotowym (V) w temperaturach 20°C i 60°C. W każdym z wymienionych z przypadków zaobserwowano zjawisko korozji wżerowej. Największą odporność na korozję wżerową wykazała próbka walcowana na zimno poddana pasywowaniu w temperaturze 60°C.
This paper presents a comparative study of the corrosion resistance of austenitic steels AISI 304L (EN 1.4307). Studies show a resistance to pitting corrosion of steel after cold rolling and passivation under different conditions. Electrochemical studies were carried out on three groups of samples: after cold rolling, after cold rolling and passivation in nitric acid (V) at temperatures of 20°C and 60°C. In each of these cases has been noted the phenomenon of pitting corrosion. The highest resistance to pitting corrosion was observed in the samples subjected to cold rolling and passivation at 60°C.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2015, 16, 6; 191-194
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of bath type for zinc plating and passivation with trivalent chromium compounds on the corrosion resistance and appearance of coatings obtained
Wpływ rodzaju kąpieli do cynkowania i pasywacji trójwartościowymi związkami chromu na odporność korozyjną i wygląd uzyskanych powłok
Autorzy:
Kołodziej, Mateusz
Niciejewska, Anna
Winiarski, Juliusz
Powiązania:
https://bibliotekanauki.pl/articles/41157153.pdf
Data publikacji:
2023
Wydawca:
Wydawnictwo SIGMA-NOT
Tematy:
weak-acid zinc
conversion coating
passivation
zinc electroplating
electroplating
chromating
alkaline zinc
electrochemical metal deposition
cynk słabo kwaśny
powłoka konwersyjna
pasywacja
cynk galwaniczny
galwanotechnika
chromianowanie
cynk alkaliczny
elektrochemiczne osadzanie metali
Opis:
Zinc coatings obtained in electrolytic zinc plating differ in terms of corrosion resistance and their visual aspect depending on the brightener and basic components used. In order to achieve industrial properties and a desired appearance of the coatings, commercial organic additives made by Galvano-Partners and Dipsol were used. It has been shown that a greater effect on corrosion resistance can be achieved when the same passivation is applied to different zinc substrates. Electrolytically applied zinc from a zinc chloride solution and with thin-film passivation shows a higher polarization resistance after 24 h compared to a coating obtained using two technologies utilizing (alkaline) baths based on sodium zincate, despite having the same conversion coating. In the aspect of one electrolytic zinc coating with different chromate coatings, disproportions between the successive conversion technologies are noted in the polarization resistance. Potentiodynamic curves describing a zinc coating with different chromate layers applied indicate a major variation in the barrier properties of the studied material.
W zależności od wykorzystanego składnika wybłyszczającego oraz składników podstawowych otrzymywane powłoki cynkowe z cynkowania elektrolitycznego różnią się pod względem odporności korozyjnej oraz wizualnie. By uzyskać właściwości przemysłowe oraz określony wygląd powłok, wykorzystano komercyjne dodatki organiczne firm Galvano-Partners oraz Dipsol. Jeszcze większy wpływ na odporność korozyjną ma zastosowanie pasywacji chemicznej przez wytworzenie powłok konwersyjnych na powłokach cynkowych. Istotne różnice daje nawet zastosowanie tej samej pasywacji na różnym podłożu cynkowym: cynk nałożony elektrolitycznie w kąpieli sporządzonej na bazie chlorku cynku (zwanej słabo kwaśną) i z pasywacją cienkopowłokową (0,07 μm ±0,03 μm) wykazuje po 24 h wyższą rezystancję polaryzacyjną w porównaniu z powłoką wytworzoną zgodnie z dwoma technologiami, w których wykorzystuje się kąpiele sporządzone na bazie cynkanu sodu (zwane alkalicznymi), pomimo tej samej powłoki konwersyjnej. W wypadku takich samych powłok cynkowych wytworzonych elektrolitycznie, lecz pokrytych różnymi powłokami konwersyjnymi uzyskanymi chemicznie w wyniku zastosowania kąpieli sporządzonych na bazie związków chromu trójwartościowego obserwuje się różną odporność korozyjną w zależności od zastosowanych technologii wykonywania powłok konwersyjnych. Krzywe potencjodynamiczne otrzymane dla próbek z powłoką cynkową z nałożonymi różnymi warstwami konwersyjnymi wskazują na zróżnicowanie odporności korozyjnej badanego materiału.
Źródło:
Ochrona przed Korozją; 2023, 5; 132-138
0473-7733
2449-9501
Pojawia się w:
Ochrona przed Korozją
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania porównawcze odporności korozyjnej stali austenitycznej AISI 304L (EN 1.4307) po walcowaniu na zimno oraz po pasywowaniu w kwasie cytrynowym oraz EDTA
Comparative studies of corrosion resistance of AISI 304L (EN 1.4307) austenitic stainless steel after cold rolling and passivation in the citric acid and edetic acid
Autorzy:
Rokosz, K.
Hryniewicz, T.
Solecki, G.
Dudek, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/314431.pdf
Data publikacji:
2015
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
korozja wżerowa
stal austenityczna 304L
stal nierdzewna
pasywacja
walcowanie na zimno
kwas wersenowy
kwas cytrynowy
EDTA
pitting corrosion
AISI 304L austenitic steel
stainless steel
passivation
cold rolling
edetic acid
citric acid
Opis:
Niniejszy artykuł prezentuje badania porównawcze odporności korozyjnej austenitycznej stali stopowej AISI 304L (EN 1.4307) w roztworze Ringera. Wyniki badań przedstawiają odporność stali na korozję wżerową stali po walcowaniu na zimno oraz pasywowaniu w różnych warunkach. Badania elektrochemiczne przeprowadzono dla trzech grup próbek: po walcowaniu na zimno, po walcowaniu na zimno oraz pasywowaniu w kwasie cytrynowym i kwasie wersenowym w temperaturach 20°C i 60°C. W każdym z wymienionych przypadków zaobserwowano zjawisko korozji wżerowej. Największą odporność na korozję wżerową wykazała próbka walcowana na zimno poddana pasywowaniu w temperaturze 60°C.
This paper presents a comparative study of the corrosion resistance of austenitic steel AISI 304L (EN 1.4307) in the Ringer’s solution. The studies describe the resistance to pitting corrosion of the stainless steel after the cold rolling and passivation under different conditions. Electrochemical studies were carried out on three groups of samples: after cold rolling, after cold rolling and passivation in the citric acid and edetic acid at temperatures of 20°C and 60°C. In each of these cases, the phenomenon of pitting corrosion has been noted. The highest resistance to pitting corrosion was observed in the samples subjected to the cold rolling and passivation at 60°C.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2015, 16, 6; 198-201
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-13 z 13

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies