Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "partial discharge" wg kryterium: Wszystkie pola


Wyświetlanie 1-8 z 8
Tytuł:
Pilot implementation of the on-line partial discharge monitoring system for heads of the high voltage cable lines
Autorzy:
Konarski, Michał
Węgierek, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/220896.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cable lines diagnostics
partial discharges
unconventional methods of partial discharges measurement
UHF electromagnetic method
Opis:
The article presents the assumptions, characteristics and description of the implementation of a pilot system for on-line monitoring of partial discharges in heads of the high-voltage cable lines. The main purpose of the implementation was to increase the reliability of cable line heads by equipping them with a system of continuous assessment of technical condition with direct transmission of measurement data and alarms to the SCADA system. In order to achieve the assumed goal, unconventional methods for measuring partial discharges were used, the application of which does not require disconnecting the line from the voltage. The implementation was carried out on an active 110 kV high voltage cable line in the area of activity of one of the Distribution System Operators.
Źródło:
Metrology and Measurement Systems; 2020, 27, 2; 373-382
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie szyków antenowych w lokalizacji źródeł wyładowań niezupełnych
Application of antenna arrays in the location of partial discharge sources
Autorzy:
Roehrich, J.
Szafraniak, B.
Zydroń, P.
Powiązania:
https://bibliotekanauki.pl/articles/267219.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wyładowania niezupełne
systemy lokalizacyjne
szyki antenowe
metody TOA/TDOA
partial discharges
locating system
antenna arrays
TOA/TDOA methods
Opis:
Wyładowania niezupełne (wnz) są źródłami impulsowych zaburzeń elektromagnetycznych o bardzo szerokim widmie. Dzięki temu dla ich wykrywania i lokalizowania mogą być stosowane metody antenowe, wykorzystujące różne techniki pomiarowe. W szczególności dotyczy to lokalizowania wyładowań powstających w liniach napowietrznych i urządzeniach stacji elektroenergetycznych wysokich i najwyższych napięć. W artykule przedstawiono podstawy i rozważania teoretyczne dotyczące zastosowania w tym celu szyków (macierzy) antenowych o różnych konfiguracjach oraz wybrane wyniki badań laboratoryjnych. Przedstawione zostały m.in. analizy zastosowania metody TDOA (Time Difference Of Arrival), pozwalającej na określenie położenia źródeł wyładowań niezupełnych w oparciu o pomiar różnic czasów detekcji przebiegów impulsowych rejestrowanych przez poszczególne anteny wchodzące w skład szyku antenowego.
Partial discharges (PD) are sources of very short impulsive electromagnetic disturbances with extra wide spectrum. As a result, aerial methods using various measuring techniques can be used to detect and locate them. In particular, this refers to locating partial discharges occurring at overhead transmission lines and power station equipment of high and very high voltages. The paper, which presents the continuation of the work of authors in this field, describes theoretical foundations and theoretical considerations as well as the results of laboratory investigations of the use of antenna arrays of various configurations for PDs source location. The analysis of the application of the TDOA method (Time Difference of Arrival) to determine the position of the discharge sources is based on the measurement of the time differences of pulse waveforms received by the individual antennas – members of particular antenna array.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 57; 103-108
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using Clustering Methods for the Identification of Acoustic Emission Signals Generated by the Selected Form of Partial Discharge in Oil-Paper Insulation
Autorzy:
Borucki, S.
Łuczak, J.
Zmarzły, D.
Powiązania:
https://bibliotekanauki.pl/articles/177657.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic emission method
acoustic signals
partial discharges
insulation
power transformer
Opis:
The article presents the results concerning the use of clustering methods to identify signals of acoustic emission (AE) generated by partial discharge (PD) in oil-paper insulation. The conducted testing featured qualitative analysis of the following clustering methods: single linkage, complete linkage, average linkage, centroid linkage and Ward linkage. The purpose of the analysis was to search the tested series of AE signal measurements, deriving from three various PD forms, for elements of grouping (clusters), which are most similar to one another and maximally different than in other groups in terms of a specific feature or adopted criteria. Then, the conducted clustering was used as a basis for attempting to assess the effectiveness of identification of particular PD forms that modelled exemplary defects of the power transformer’s oil-paper insulation system. The relevant analyses and simulations were conducted using the Matlab estimation environment and the clustering procedures available in it. The conducted tests featured analyses of the results of the series of measurements of acoustic emissions generated by the basic PD forms, which were obtained in laboratory conditions using spark gap systems that modelled the defects of the power transformer’s oil-paper insulation.
Źródło:
Archives of Acoustics; 2018, 43, 2; 207-215
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przetwarzanie i analiza impulsów wyładowań niezupełnych przy zastosowaniu pakietu Matlab
Processing and analysis of partial discharge pulses using of the MatlabŽ program package
Autorzy:
Zydroń, P.
Roehrich, J.
Powiązania:
https://bibliotekanauki.pl/articles/268118.pdf
Data publikacji:
2009
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wyładowania niezupełne (wnz)
analiza sygnałów
pakiet programowy Matlab
partial discharges
signal analysis
MATLAB program package
Opis:
Wyładowania niezupełne (wnz) występujące w układach izolacyjnych urządzeń elektrycznych są dynamicznym, nieliniowym zjawiskiem fizycznym wywołującym krótkotrwały przepływ ładunków elektrycznych, ograniczonym jedynie do części powierzchni lub objętości dielektryka. Ze względu na fakt, że występują one z reguły w miejscach, które mogą być utożsamiane z defektami izolacji, ich detekcja, lokalizacja i rozpoznawanie są elementami współczesnej diagnostyki eksploatacyjnej. Szerokopasmowy charakter impulsów prądowych generowanych przez wyładowania niezupełne oraz stochastyczność procesów prowadzących do ich powstawania sprawiają, że w badaniach stosowane są róSne metody detekcji i analizy sygnałów pomiarowych. Wygodnym narzędziem, umoSliwiającym testowanie i optymalizację procedur przetwarzania tych sygnałów jest wyposaSony w odpowiednie oprogramowanie komputer, sprzęSony z urządzeniem dokonującym ich rejestracji. Artykuł bazując na podstawach detekcji wnz przedstawia przykłady procedur przetwarzania uwzględniających ich właściwości sygnałowe. Wszystkie prezentowane wyniki uzyskano stosując procedury implementowane w pakiecie MatlabŽ.
The partial discharges (PD) are dynamic, non-linear phenomenon occurring in high voltage insulating system. It produces very short local current pulses connected usually with specific defects of insulating system. Detection, localization and recognition of PD sources are used in modern measuring systems for diagnostics of high voltage insulation. Wide-band character of PD pulses and stochastic nature of PD processes lead in practice to application of many different detection and analysis methods. Suitable tool for testing and optimization of PD data processing procedures is computer connected with PD signal measuring instrument and equipped with dedicated properly prepared software. The paper starting from basics of PD signal detection presents examples of advanced PD data processing methods implemented in MatlabŽ program package.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2009, 26; 133-136
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mobilny system pomiarowy do badania zjawiska wyładowań niezupełnych metodą emisji akustycznej
: Mobile measuring system for investigating partial discharge phenomena by the acoustic emission method
Autorzy:
Błachowicz, A.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/155765.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
metoda emisji akustycznej
wyładowania niezupełne
system czasu rzeczywistego
mobilny system pomiarowy
acoustic emission method
partial discharges
real time system
mobile measuring system
Opis:
W artykule przedstawiono założenia projektowe oraz sposób realizacji mobilnego sytemu umożliwiającego pomiary wyładowań niezupełnych (WNZ), jakie mogą występować w izolacji kondensatorów elektroenergetycznych do kompensacji mocy biernej, wykonywane przy zastosowaniu metody emisji akustycznej (EA). Zdefiniowana została podstawowa potrzeba budowy mobilnego systemu pomiarowego. Z uwagi na utrudniony dostęp oraz pracę w warunkach mogących bezpośrednio zagrozić życiu osób diagnozujących stan obiektu elektroenergetycznego, znajdującego się w rozdzieli średniego napięcia, detekcja zjawiska WNZ jest znacznie utrudniona. Autorzy prezentują rozwiązanie umożliwiające diagnozę prowadzoną zdalnie, z jednoczesną możliwością wykonywania pomiarów diagnostycznych układów izolacyjnych metodą on-line. Artykuł zawiera informacje dotyczące rozwiązań zastosowanych w systemie. System składa się z kilku, ściśle związanych ze sobą elementów, dla których przewidziano odpowiednie funkcje. Zaprezentowane zostały możliwości elementów takich jak aplikacja WNZDetect, robot mobilny oraz część pomiarowo detekcyjną. Zaprezentowany został robot o nazwie SQ1, który został wyposażony w kilka typów modułów. Są to: moduł główny, dwa moduły sterujące pracą kół oraz moduł monitorujący. W artykule scharakteryzowano ich funkcjonalność i rolę pełnioną w systemie. Autorzy opisali wykorzystany do oprogramowania modułów robota, system czasu rzeczywistego o nazwie Nut/OS. Przedstawione zostały również, zawarte w środowisku Ethernut (Nut/OS) biblioteki oraz funkcje poszczególnych pakietów. W podsumowaniu zdefiniowano dalsze perspektywy wykorzystania zbudowanego systemu w badaniu zjawiska WNZ.
The paper presents design assumptions and the way of realizing the mobile system which enables measurements of partial discharges (PDs) which can occur in insulation of electric power capacitors for compensation of reactive power. The measurements are taken by means of the acoustic emission (AE) method. The basic need for building a mobile measuring system is defined. Due to a difficult access and work under conditions which can be hazardous to lives of people diagnosing the condition of an electric power object in the mean-voltage switching station, the detection of the PD phenomenon is significantly difficult. The authors propose a solution making it possible to perform a remotely-controlled diagnosis with simultaneous possibility of taking diagnostic measurements of insulation systems by the on-line method. The paper contains information on the solutions applied in the system. The system consists of a few elements closely connected with one another for which adequate functions are predicted. The possibilities of such elements as the WNZDetect application, a mobile robot and a measuring and detecting part are given. Also a robot called SQ1 equipped with a few types of modules is presented. They are: the main module, two modules controlling the operation of the wheels and a monitoring module. Their functionality and the role in the system are characterized in the paper. The authors describe the real time system called Nut/OS used for programming the robot modules. There are also presented libraries and functions of the particular packets contained in the Ethernut (Nut/OS) environment. In the final remarks further perspectives of using this system in PD phenomenon investigations are defined.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 1, 1; 27-29
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie propagacji impulsów wyładowań niezupełnych w uzwojeniach transformatorów energetycznych z zastosowaniem stanowiska laboratoryjnego
Modelling partial discharge pulses propagation in the windings of power transformers using laboratory stand
Autorzy:
Zydroń, P.
Bonk, M.
Fuśnik, Ł.
Bęc, K.
Maniak, D.
Szafrański, F.
Powiązania:
https://bibliotekanauki.pl/articles/267389.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
uzwojenia transformatora
wyładowania niezupełne
lokalizacja
modelowanie numeryczne
transformer windings
partial discharges
localization
numerical modelling
Opis:
Transformatory energetyczne są jednymi z podstawowych elementów systemu elektroenergetycznego. Objawem wewnętrznych defektów ich układu izolacyjnego może być powstawanie wyładowań niezupełnych (wnz). Sygnały elektryczne wywołane przez wnz są rejestrowane na doprowadzeniach liniowych, do których docierają propagując wzdłuż uzwojeń, od miejsca ich występowania. W zależności od położenia defektu oraz jednostkowych parametrów elektrycznych uzwojenia zmieniają się parametry czasowo-częstotliwościowe sygnałów obserwowanych w miejscu ich detekcji. W artykule przedstawiono wyniki badań propagacji impulsów wnz na modelu laboratoryjnym uzwojenia transformatora oraz, dla porównania, wyniki symulacji numerycznych w programie Matlab/Simulink. Podczas symulacji stosowano pewne uproszczenia złożonej struktury uzwojenia transformatora analizując wpływ miejsca wyładowania na wybrane właściwości impulsów rejestrowanych na zacisku liniowym.
Power transformers are one of the basic elements of the power system. The occurrence of partial discharge is a symptom of internal defects of their insulating system. Electrical signals caused by partial discharges are recorded on the line terminals that receive electrical signals propagating along the winding from the source of discharge. Depending on the location of the defect and the characteristic parameters of the electrical windings are changing parameters of the timefrequency signals observed in the place of its detection. The article presents the results of the propagation of pulses PD in models of transformer windings, compared to the results of numerical simulations. During the simulation takes into account the complex, multi-element structure of the windings of the transformer and its impact on the time-frequency characteristics of pulses recorded on a terminal line.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2016, 51; 221-224
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena stanu technicznego linii kablowych średnich napięć na podstawie pomiaru wyładowań niezupełnych
Assessment of the technical condition of medium-voltage cable lines on the basis of partial discharge measurement
Autorzy:
Florkowska, B.
Zydroń, P.
Ziąbka, W.
Powiązania:
https://bibliotekanauki.pl/articles/155782.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
diagnostyka kabli
wyładowania niezupełne
diagnostics of cables
partial discharges
Opis:
Niezawodność pracy linii kablowych średniego napięcia jest jednym z czynników decydujących o poziomie niezawodności dostaw energii elektrycznej. Dla oceny stanu technicznego linii stosowane są różne metody badań, m.in. wykonywane są próby napięciowe oraz pomiary wyładowań niezupełnych. Ze względu na duże wartości pojemności elektrycznej linii kablowych w próbach stosowane są napięcia o obniżonej częstotliwości lub napięcia specjalne (np. oscylacyjne). Artykuł przedstawia problemy z tym związane - wpływające na pomiar i lokalizację wyładowań niezupełnych. Wyniki prezentowanych badań, zarówno laboratoryjnych jak i eksploatacyjnych wskazują na zasadność i użyteczność stosowania napięć oscylacyjnych o częstotliwościach zbliżonych do częstotliwości roboczej.
The reliability of medium voltage cable lines is one of the main factors deciding on the reliability level of electrical energy distribution. Failures of cables are mainly caused by local defects in insulating systems which are the sources of partial discharges (PD). Voltage tests and PD measurements are usually applied to assessing the technical condition of cable lines. These tests are performed when using DC, oscillating or low frequency voltages. The basis of the PD measurements in cables is the recording of discharge pulses, determination of their intensity, localization of sources and identification. The characteristic feature of PD measurements in cables is the propagation of pulses from the PD source, their attenuation and reflections. These effects are used for the localization of PD sources by means of time domain reflectometry (Fig. 1). The investigations performed in a laboratory have shown that there is the significant difference between the PD parameters at 50 Hz and those at lower frequencies (Fig. 2). The examples of measurements taken for PD localization by using the OWTS method (Fig. 3) (Oscillating Wave Test System) in new and being in exploitation cables are also presented (Figs. 4, 5, and 6). Taking into account the described results one can state that PD measurements should be taken at frequencies close to the nominal one. The tested OWTS method enables detection of PDs in new and old cables of different types. However, its application to practice is connected with the necessity of selecting the allowed PD levels for new and old cables and accessories. That is why it is recommended to collect the laboratory and exploitation experience.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 1, 1; 59-62
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kierunkowe układy detekcji VHF/UHF dla lokalizacji źródeł wyładowań niezupełnych w liniach napowietrznych i urządzeniach stacji elektroenergetycznych
Directional VHF/UHF detection systems for the location of partial discharge sources in overhead lines and substations equipment
Autorzy:
Roehrich, J.
Zydroń, P.
Szafraniak, B.
Kwaśny, D.
Szeląg, D.
Powiązania:
https://bibliotekanauki.pl/articles/952812.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wyładowania niezupełne
systemy lokalizacyjne
detekcja VHF/UHF
anteny kierunkowe
partial discharges
locating system
VHF/UHF detection
directional antennas
Opis:
Współczesne wymagania dotyczące niezawodności dostaw energii elektrycznej rodzą konieczność prowadzenia badań diagnostycznych i monitorowania poprawności działania pracujących urządzeń elektroenergetycznych. Występujące defekty linii napowietrznych oraz urządzeń stacji elektroenergetycznych, charakteryzujące się podwyższeniem wartości lokalnego natężenia pola elektrycznego ponad wartość krytyczną powodują powstawanie wyładowań niezupełnych, w różnych ich formach. Pozwala to stosować, w celu wykrywania i lokalizowania defektów, metody antenowe, z detekcją szerokopasmową w zakresach VHF/UHF. W artykule dokonano przeglądu zastosowań układów szerokopasmowej detekcji antenowej w diagnostyce urządzeń elektroenergetycznych. Przedstawiono wyniki badań laboratoryjnych wybranych układów detekcji kierunkowej, służących wykrywaniu różnych form wyładowań elektrycznych w powietrzu poprzez detekcję impulsowych zaburzeń elektromagnetycznych.
Contemporary requirements for a reliable supply of electricity generate the need for diagnostics and monitoring of proper operation of working electrical power equipment. Defects occurring in transmission lines and substations devices, characterized by the increase of the local electric field strength above the critical value, cause the formation of partial discharges (PD), in their various forms. In order to detect and locate defects it is possible to use wideband antenna methods for PD pulses detection in the VHF/UHF range. The article reviews the applications of wideband antenna detection systems in the diagnosis of the electrical power devices. The results of laboratory tests of selected directional detection systems applied for location of various forms of electrical discharges in the air, by detecting pulsed electromagnetic disturbances, are presented.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2016, 51; 159-162
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies