Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Błachowicz, A." wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
A mobile system for measurements of partial discharges controlled by electroencephalographic waves
Autorzy:
Błachowicz, A.
Paszkiel, Sz.
Powiązania:
https://bibliotekanauki.pl/articles/384381.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
EEG
mobile robot
partial discharges
Opis:
The article presents the concepts of a mobile system for measurements of partial discharges controlled by brain waves. In order to describe that, a robot, which takes measurements of partial discharges, has been worked out. The discharges may occur in an isolator of electrical devices such as capacitors and transformers. What is more, a concept of a link between the robot and a human brain is described, in order to ensure a direct communication on the level of the human brain and the robot.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2010, 4, 3; 31-35
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mobilny system do pomiaru wyładowań niezupełnych sterowany falami elektroencefalograficznymi
A mobile system for measurements of partial discharges controlled by electroencephalographic waves
Autorzy:
Błachowicz, A.
Paszkiel, S.
Powiązania:
https://bibliotekanauki.pl/articles/275161.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
biocybernetyka
wyładowania niezupełne
mobilne systemy pomiarowe
biocybernetics
partial discharges
mobile measurement systems
Opis:
W artykule przedstawiono koncepcję sterowanego falami mózgowymi, mobilnego systemu do pomiaru wyładowań niezupełnych. Do wykonywania pomiarów wyładowań niezupełnych w dielektrykach urządzeń elektrycznych (kondensatory, transformatory) został opracowany specjalny robot. Ponadto przedstawiona została idea sprzęgnięcia robota z mózgiem człowieka zapewniającego bezpośrednią komunikację na linii: mózg człowieka-robot.
The article presents the concepts of a mobile system for measurements of partial discharges controlled by brain waves. In order to describe that, a robot, which takes measurements of partial discharges, has been worked out. The discharges may occur in a isolator of electrical devices such as capacitors and transformers. What is more, a concept of a link between the robot and a human brain is described, in order to ensure a direct communication on the level of the human brain and the robot.
Źródło:
Pomiary Automatyka Robotyka; 2010, 14, 2; 12-16
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mobilny system pomiarowy do badania zjawiska wyładowań niezupełnych metodą emisji akustycznej
: Mobile measuring system for investigating partial discharge phenomena by the acoustic emission method
Autorzy:
Błachowicz, A.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/155765.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
metoda emisji akustycznej
wyładowania niezupełne
system czasu rzeczywistego
mobilny system pomiarowy
acoustic emission method
partial discharges
real time system
mobile measuring system
Opis:
W artykule przedstawiono założenia projektowe oraz sposób realizacji mobilnego sytemu umożliwiającego pomiary wyładowań niezupełnych (WNZ), jakie mogą występować w izolacji kondensatorów elektroenergetycznych do kompensacji mocy biernej, wykonywane przy zastosowaniu metody emisji akustycznej (EA). Zdefiniowana została podstawowa potrzeba budowy mobilnego systemu pomiarowego. Z uwagi na utrudniony dostęp oraz pracę w warunkach mogących bezpośrednio zagrozić życiu osób diagnozujących stan obiektu elektroenergetycznego, znajdującego się w rozdzieli średniego napięcia, detekcja zjawiska WNZ jest znacznie utrudniona. Autorzy prezentują rozwiązanie umożliwiające diagnozę prowadzoną zdalnie, z jednoczesną możliwością wykonywania pomiarów diagnostycznych układów izolacyjnych metodą on-line. Artykuł zawiera informacje dotyczące rozwiązań zastosowanych w systemie. System składa się z kilku, ściśle związanych ze sobą elementów, dla których przewidziano odpowiednie funkcje. Zaprezentowane zostały możliwości elementów takich jak aplikacja WNZDetect, robot mobilny oraz część pomiarowo detekcyjną. Zaprezentowany został robot o nazwie SQ1, który został wyposażony w kilka typów modułów. Są to: moduł główny, dwa moduły sterujące pracą kół oraz moduł monitorujący. W artykule scharakteryzowano ich funkcjonalność i rolę pełnioną w systemie. Autorzy opisali wykorzystany do oprogramowania modułów robota, system czasu rzeczywistego o nazwie Nut/OS. Przedstawione zostały również, zawarte w środowisku Ethernut (Nut/OS) biblioteki oraz funkcje poszczególnych pakietów. W podsumowaniu zdefiniowano dalsze perspektywy wykorzystania zbudowanego systemu w badaniu zjawiska WNZ.
The paper presents design assumptions and the way of realizing the mobile system which enables measurements of partial discharges (PDs) which can occur in insulation of electric power capacitors for compensation of reactive power. The measurements are taken by means of the acoustic emission (AE) method. The basic need for building a mobile measuring system is defined. Due to a difficult access and work under conditions which can be hazardous to lives of people diagnosing the condition of an electric power object in the mean-voltage switching station, the detection of the PD phenomenon is significantly difficult. The authors propose a solution making it possible to perform a remotely-controlled diagnosis with simultaneous possibility of taking diagnostic measurements of insulation systems by the on-line method. The paper contains information on the solutions applied in the system. The system consists of a few elements closely connected with one another for which adequate functions are predicted. The possibilities of such elements as the WNZDetect application, a mobile robot and a measuring and detecting part are given. Also a robot called SQ1 equipped with a few types of modules is presented. They are: the main module, two modules controlling the operation of the wheels and a monitoring module. Their functionality and the role in the system are characterized in the paper. The authors describe the real time system called Nut/OS used for programming the robot modules. There are also presented libraries and functions of the particular packets contained in the Ethernut (Nut/OS) environment. In the final remarks further perspectives of using this system in PD phenomenon investigations are defined.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 1, 1; 27-29
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zrobotyzowany system do badania zjawisk fizycznych w elektroenergetyce
Robotized system for researches physical phenomena in electrical power engineering
Autorzy:
Błachowicz, A.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/276431.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
robotyka
wyładowania niezupełne
mobilny system pomiarowy
robotics
partial discharges
mobile measuring system
Opis:
Wyładowania niezupełne WNZ są zjawiskiem fizycznym mogącym wystąpić w układach izolacyjnych urządzeń elektroenergetycznych. Zjawisko to jest niekorzystne, a zwiększająca się intensywność jego występowania może świadczyć o znacznej degradacji badanej izolacji. W artykule przedstawiono założenia projektowe oraz sposób realizacji mobilnego sytemu umożliwiającego pomiary WNZ, jakie mogą występować w izolacji kondensatorów elektroenergetycznych wykorzystywanych do kompensacji mocy biernej. Pomiary są wykonywane przy zastosowaniu metody emisji akustycznej EA. Zaproponowano rozwiązanie umożliwiające przeprowadzenie diagnostyki pracującego kondensatora elektroenergetycznego zdalnie i on-line. Scharakteryzowano rozwiązania zastosowane w zaprojektowanym i zbudowanym systemie pomiarowym. Opisano podstawowe moduły robota SQ1 i scharakteryzowano ich funkcjonalność. W podsumowaniu określono perspektywy wykorzystania systemu w badaniu zjawisk WNZ w układach izolacyjnych.
Partial Discharges PD are this physical phenomena which can occur in insulation systems electrical power engineering devices, such as: transformers, electro energetic capacitors, motors etc. This phenomena is unfavorable and increase intensity their occurrence can be show about degradation of insulation system. In the article presents project and realization of mobile system enable to detection of PD using an Acoustic Emission method AE. The possible of measurements, in this specific, dangerous places, constitute a real technical challenge within areas where there are big difficulties for analysts with the access to the subject under research. Authors in the article propose a solution diagnosis of electro energetic capacitor by remote-controlled system and in on-line mode. Article describe possibilities of mobile inspection robot, named SQ1, and their construction. There is presents the equipment that enables to move it within the inspection areas. In the summary are describe following using perspectives of the remote-controlled mobile inspection robot to detection Partial Discharges phenomena of located in medium voltage power distribution station devices.
Źródło:
Pomiary Automatyka Robotyka; 2010, 14, 7-8; 63-65
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies