Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "heat recovery system" wg kryterium: Temat


Wyświetlanie 1-7 z 7
Tytuł:
Alignment of the heat recovery potential with the local area heat demand for selected industrial entities in the city of Gliwice
Autorzy:
Banasik, Aleksandra
Kostowski, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/41185413.pdf
Data publikacji:
2023
Wydawca:
Politechnika Warszawska, Instytut Techniki Cieplnej
Tematy:
waste heat
heat recovery
district heating system
residential sector
energy management
strata ciepła
odzysk ciepła
system ciepłowniczy
sektor mieszkaniowy
zarządzanie energią
Opis:
Waste heat plays a significant role in obtaining the 4th and 5th generation of District Heating (DH) System in cities. This article presents the possibilities of integrating selected waste heat emitters into DH, with the objective of meeting the demand for heat for the selected residential area (approx. 4000 inhabitants) in the city of Gliwice (180 000 inhabitants). The total heating demand of the studied area was estimated at 19 800 GJ including both space heating and domestic hot water. The maximum thermal power was estimated at approx. 2.45 MW. The demand was calculated on the basis of registered metering values for individual buildings which were processed and summarized due to the lack of collective meters for the district. A detailed data classification, correction and completion procedure was elaborated to deal with non-uniform and low-quality data registration. Two industrial objects with waste heat generation were examined to be integrated with the local DH network. The waste heat generation potential equals 9.0 MW for plant #1 and 0.9 MW for plant #2. Apart from the constant generation declared by the industrial entities, realistic profiles including possible shaft-work and maintenance periods were created. It has been shown that the total heat demand for selected residential areas can be covered by integrating waste heat into the current DH network. Depending on the waste heat generation profile, the local area heat demand can be covered entirely or to a large degree (coverage factor ranges from 72 to 100%). The waste heat utilization factor ranges from 6.3 to 8.3%. To manage the remaining waste heat potential, it is required to build additional district heating pipelines and nodes connecting to the existing network to receive an additional 7.45 MW thermal power. The potential of waste heat recovery is significant at the scale of a medium sized city: integrating two large industrial emitters allows up to 13% decarbonization of heats production in the local district heating plan.
Źródło:
Journal of Power Technologies; 2023, 103, 2; 104-117
1425-1353
Pojawia się w:
Journal of Power Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System pozyskiwania energii cieplnej z sond geotermalnych
Integrated heat energy system of the livestock building and ground boreholes
Autorzy:
Kreis-Tomczak, K.
Powiązania:
https://bibliotekanauki.pl/articles/238919.pdf
Data publikacji:
2008
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
pompa ciepła
sonda geotermalna
odzysk ciepła
energia słoneczna
heat pump system
ground boreholes
heat recovery
solar energy
livestock building
Opis:
Z prac różnych badaczy dotyczących pozyskiwania energii z sond geotermalnych wynika, że temperatura gruntu z sondą geotermalną spada pod koniec okresu grzewczego, a w pobliżu sondy grunt ochładza się przez pierwsze 2-3 lata. Po tym okresie proces się stabilizuje, ale temperatura gruntu pozostaje niższa o 1-2 K w porównaniu z gruntem bez sondy. Symulacja tego procesu w okresie 25-letniej eksploatacji pokazała, że po tym okresie deficyt temperatury pozostaje na poziomie 0,1 K. Ponieważ odzysk ciepła z sondy geotermalnej może powodować zachwiania we właściwościach cieplnych gruntu, w IBMER podjęto prace nad przywróceniem tej równowagi. W pierwszym etapie badano system oparty na wymiennikach gruntowych bez podłączenia dachu energetycznego. Badania prowadzono w okresie od 26.01-16.03.2007. Dokonywano odczytów energii cieplnej uzyskanej z sond geotermalnych oraz energii, która została przesłana do obiegu górnego źródła (c.o.). Uzyskano 5,834 GJ energii cieplnej (1620,56 kWh), a dostarczono 447,1 kWh energii elektrycznej. Z obliczeń energii dostarczonej do uzyskanej wynika, że współczynnik COP wynosi 3,9. W tym okresie dostarczono do obiegu c.o. 5,836 GJ energii cieplnej.
Many studies by different researchers show that the temperature close to a borehole is dropping quickly in winter during first 2 years, only to stay more or less stable over the next years. In the summer time, initial temperatures are not achieved again, but the temperature drop is decreasing from year to year. According to computer simulation, a complete recovery will occur after an indefititely long time period; nevertheless, the remaining temperature deficit after 25 years since the operation has been stopped, at the level of 0.1 K only. Because the heat recovery from boreholes could disturb thermal properties of the ground, some research works were undertaken by IBMER, to bring this balance back. The aim of research dealing with the system which included energy roof, deep litter and ground boreholes, was to determine the efficiency of heat delivery/recovery to and from the boreholes, in aspects of hydrogeothermal processes near the boreholes. System of boreholes (without energy roof) was investigated at the first stage of research. Investigations were conducted since 26.01. to 16.03.2007. Amounts of the heat from boreholes and heat conveyed to the central heating system were recorded. Over investigation period 5.834 GJ (1620.56 kWh) of heat energy have been gained, in comparison to electric en-ergy input on the level 447.1 kWh. The input energy to the gained energy ratio (COP) amounted to 3.9. During investigations 5.836 GJ of heat energy were delivered to the central heating system.
Źródło:
Problemy Inżynierii Rolniczej; 2008, R. 16, nr 2, 2; 167-174
1231-0093
Pojawia się w:
Problemy Inżynierii Rolniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exergy-based control strategy in a dwelling ventilation system with heat recovery
Oparta na egzergi strategia sterowania systemem wentylacji mieszkań z odzyskiem ciepła
Autorzy:
Voloshchuk, Volodymyr
Polishchuk, Mariya
Powiązania:
https://bibliotekanauki.pl/articles/407846.pdf
Data publikacji:
2020
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
ventilation system
exergy analysis
control
heat recovery
exergy saving
system wentylacji
analiza egzergii
kontrola
odzysk ciepła
oszczędność egzergii
Opis:
The paper presents energy and exergy analysis of a typical dwelling ventilation system with heat recovery for Ukrainian climatic conditions using a quasi-steady state approach over 24-hour time-steps. Evaluation of such systems on the base of the first law of thermodynamics demonstrates that heat recovery is beneficial for the whole variety of operational modes. Such methodology identifies as a thermodynamic inefficiency only energy losses to the surroundings with the exhaust air. The exergy-based analysis can detect additional inefficiencies due to irreversibilities within the components of the system. As a result the exergetic investigations show that for the ventilation systems there are operating conditions for which heat recovery increases exergy of fuel expended to provide the ventilation air compared to cases without bringing any recovery of heat and additional power consumption to drive the air flow by the fans. For the specified system, in case of switching ventilation unit to the operation mode of lower values of spent fuel exergy it is possible to provide annual saving of the primary energy sources from 5 to 15%.
W pracy przedstawiono analizę energetyczną i egzergetyczną typowego systemu wentylacji mieszkań z odzyskiem ciepła dla ukraińskich warunków klimatycznych z zastosowaniem podejścia quasi-stabilnego w 24-godzinnych krokach czasowych. Ocena takich systemów w oparciu o pierwsze prawo termodynamiki wykazuje, że odzysk ciepła jest korzystny dla całego szeregu trybów pracy. Taka metodologia identyfikuje jako nieefektywne termodynamicznie tylko straty energii do otoczenia wraz z powietrzem wylotowym. Analiza egzergetyczna może wykryć dodatkowe nieefektywności wynikające z nieodwracalności elementów systemu. W rezultacie badania egzergetyczne wykazują, że w systemach wentylacyjnych występują warunki pracy, dla których odzysk ciepła zwiększa egzergię paliwa zużytego do dostarczenia powietrza wentylacyjnego w porównaniu do przypadków, w których nie występuje żaden odzysk ciepła i dodatkowe zużycie energii elektrycznej do napędzania przepływu powietrza przez wentylatory. Dla określonego systemu, w przypadku przełączenia urządzenia wentylacyjnego na tryb pracy o niższych wartościach egzergii zużytego paliwa możliwe jest zapewnienie rocznych oszczędności pierwotnych źródeł energii od 5 do 15%.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2020, 10, 2; 44-47
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The potential of thermoelectric energy harvesting in vehicles equipped with ICE
Autorzy:
Buchalik, Ryszard
Rogozinski, Krzysztof
Nowak, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/133341.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Naukowe Silników Spalinowych
Tematy:
combustion engine
heat recovery
thermoelectric module
heat transfer
exhaust system
silnik spalinowy
odzysk ciepła
moduł termoelektryczny
wymiana ciepła
układ wydechowy
Opis:
The paper deals with an issue of waste heat recovery in a selected configuration of an internal combustion engine. A possibility of using thermoelectric cells (currently available on the market) for production of electricity with heat extracted from the exhaust gas was considered. The calculations were made using specialized software. Features and design assumptions of the heat recovery system were presented and their influence on parameters of the entire system was investigated (efficiency of the internal combustion engine, power, etc.). An assessment of the applicability of the energy recovery system based on thermoelectric effects and characteristic of the proposed configuration was performed. Some issues that require further research have been highlighted.
Źródło:
Combustion Engines; 2019, 58, 4; 70-74
2300-9896
2658-1442
Pojawia się w:
Combustion Engines
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Novye principy proektirovania i ocenki naruznych ograzdauscich konstrukcij s ispol’zovaniem rekuperacii tepla i drugich technologij „aktivnogo” energosberezenia
The new principles of design and assessment of external envelopes with use of heat recuperation and other technologies of “active” energy saving
Autorzy:
Spiridonov, A.
Subin, I.
Achmarov, T.
Powiązania:
https://bibliotekanauki.pl/articles/2065404.pdf
Data publikacji:
2015
Wydawca:
Politechnika Częstochowska
Tematy:
energooszczędność
odzysk ciepła
rekuperacja ciepła
energy efficient ventilated envelopes
system of active energy saving
recovery of transmission heat
coefficient of reduction of a thermal stream
recovery coefficient
Opis:
V stat’e rassmotren principial’no novyj princip povysenia energeticeskoj effektivnosti naruznych ograzdauscich konstrukcij novogo pokolenia s rekuperaciej tepla, kotoryj mozno ispol’zovat’ v stroitel’nych konstrukciach kak stroascichsa, tak i rekonstruiruemych zdanij. Odnim iz novych perspektivnych resenij v etom napravlenii avlaetsa primenenie energoeffektivnych ventiliruemych ograzdauscich konstrukcij (EVOK) zdanij s sistemoj aktivnogo energosberezenia (SAE) s rekuperaciej tepla, pozvolauscich povysit’ uroven’ teplozascity i komfortnosti mikroklimata pomescenij pri znacitel’noj ekonomii topliwno-energeticeskich resursov. Osnovnoj princip dejstvia sistemy po rekuperacii transmissionnogo tepla (za scet teploperedaci i konvekcii) i radiacionnogo tepla (teplovoe izlucenie) zaklucaetsa v osoboj organizacii uslovij postuplenia potoka naruznogo vozducha i dal’nejsego prochozdenia ego cerez konstrukciu ograzdenia, а takze teplootrazenia s pomosc’u special’nych ekranov (avtonomnych ili v vide pokryvauscich sloev). V vozdusnom promezutke, na vchode vozdusnogo potoka, sozdaetsa ploskaa vozduznaa zavesa iz cholodnogo postupauscego vozducha, maksimal’no ochlazdauscaa poverchnosti, sloi, teplootrazauscie ekrany i gibkie svazi, kotorye peredaut teplo v atmosferu. Dla ocenki predlagaemych konstrukcij EVOK predlozeny (dopolnitel’no k suscestvuuscim) esce dva pokazatela – koefficient umen’senia teplovogo potoka i koefficient rekuperacii.
In the article essentially new principle of increase of energy efficiency of external envelopes of new generation with heat recovery, which can be used in construction designs both under construction and reconstructed buildings, is considered. One of new perspective decisions in this direction is application of the energy effective ventilated envelopes (EEVE) of buildings with the system of active energy saving (SAES) with recovery of heat, allowing to raise level of heat-shielding and comfort of microclimate of rooms at considerable economy of fuel and energy resources. The basic principle of action of system on recovery of transmission heat (at the expense of a heat transfer and convection) and radiation heat (thermal radiation) consists in the special organization of conditions of receipt of a stream of external air and its further passing through an envelope, and also heat reflections by means of special screens (autonomous or in the form of covering layers). In an air interval, on an entrance of an air stream, the flat air veil from the cold arriving air, most cooling surfaces, the layers heat reflecting screens and flexible communications, which transfer heat to the atmosphere is created. For an assessment of offered designs of EEVE two more indicators - coefficient of reduction of a thermal stream and recovery coefficient are offered (in addition to existing).
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2015, 2 (16); 84--94
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania skuteczności wentylacji pomieszczeń sypialni w wielorodzinnych budynkach mieszkalnych
Research on the influence of bedroom ventilation in multi-family residential buildings
Autorzy:
Suszanowicz, D.
Pietkun-Greber, I.
Powiązania:
https://bibliotekanauki.pl/articles/126492.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
system wentylacji
sypialnia
budynek wielorodzinny
jakość powietrza
stężenie ditlenku węgla
odzysk ciepła
ventilation
bedroom
multi-family building
air quality
carbon dioxide concentration
heat recovery
Opis:
Skuteczność systemów wentylacji budynków mieszkalnych kontrolowana jest jedynie poprzez pomiar prędkości strumienia powietrza w kanale wentylacyjnym, co nie gwarantuje odpowiedniej kontroli jakości powietrza. W pracy przedstawiono wyniki badań skuteczności wentylacji naturalnej wielorodzinnych budynków mieszkalnych, stanowiącej najczęściej spotykane rozwiązanie w budynkach mieszkalnych w Polsce. Szczególną uwagę zwrócono na wentylację pomieszczenia sypialni, jako pomieszczenia, w którym spędza się około 1/3 czasu w ciągu dnia. Badano wpływ skuteczności systemu wentylacji na podstawowe parametry charakteryzujące jakość powietrza, tj. stężenie ditlenku węgla, wilgotność względną oraz temperaturę. Wyniki przeprowadzonych badań wykazały, iż w przypadku sypialni w lokalach mieszkalnych wielorodzinnych budynków mieszkalnych systemy wentylacji naturalnej nie spełniają swojej funkcji i powinny zostać zastąpione przez systemy wentylacji mechanicznej z odzyskiem ciepła.
The effectiveness of ventilation in multi-family residential buildings is controlled only by the measuring the velocity of the air stream in the ventilation ducts. It does not guarantee adequate control of air quality. This paper presents a study of the effectiveness of natural ventilation of multi-family residential buildings. Particular attention has been paid to the ventilation of the bedroom as a place where a person spends 1/3 of the time during the day. The effectiveness of ventilation systems and their influence on basic properties of air quality, i.e. carbon dioxide concentration, relative humidity and temperature were examined. The results obtained from the research show that, in the case of bedroom in the multi-family residential buildings, natural ventilation does not function effectively and should be replaced by mechanical ventilation - preferably intake and exhaust ventilation with heat recovery.
Źródło:
Proceedings of ECOpole; 2017, 11, 2; 581-589
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane rozwiązania instalacyjne w nowoczesnym proekologicznym budynku biurowym
Installation solutions in the modern ecological office building
Autorzy:
Błaszczyński, Tomasz
Wojciechowski, Michał
Powiązania:
https://bibliotekanauki.pl/articles/2055996.pdf
Data publikacji:
2022
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
instalacja
system wentylacji
system klimatyzacji
budynek biurowy
budynek proekologiczny
komfort klimatyczny
klasyfikacja
CAV
VAV
sufit chłodzący
odzysk ciepła
installation
office building
ventilation system
air-conditioning system
pro-ecological building
climatic comfort
classification
cooling ceiling
heat recovery
Opis:
W artykule przedstawiono nowoczesne systemy instalacyjne, ze szczególnym uwzględnieniem wentylacji i klimatyzacji. Przedstawiane systemy są najczęściej stosowanymi rozwiązaniami w budynkach proekologicznych, czyli takich, które są poddawane certyfikacji ekologicznej i muszą spełniać odpowiednie kryteria. Przedstawiono ocenę nowoczesnych systemów instalacyjnych wraz z ich klasyfikacją. Szczegółowo przedstawiono wentylacje zmienno- i stałostrumieniowe, klimatyzatory i klimakonwektory. Poruszono również niezbędny element dla budynku proekologicznego, jakim jest odzysk ciepła z systemów.
In the article modern installation systems, with particular reference to the ventilation and the air-conditioning was presented. Introduced systems are most often applied solutions in ecological buildings, which are subjected to the ecological certification and must fulfil suitable criteria. The estimation of modern installation systems together with their classification was represented. In detail was introduced ventilations with variable and constant-stream-oriented, air conditioners and fan coils. The indispensable element for the ecological building, which is the warm salvage of systems was also presented.
Źródło:
Przegląd Budowlany; 2022, 93, 1-2; 25--31
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies