Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "reject water" wg kryterium: Temat


Wyświetlanie 1-7 z 7
Tytuł:
Oczyszczanie odcieków z beztlenowej stabilizacji osadów z oczyszczalni ścieków mleczarskich przy zastosowaniem metody hydrofitowej
Treatment of Reject Water from Anaerobic Sewage Sludge Stabilization in Constructed Wetland
Autorzy:
Dąbrowski, W.
Wiater, J.
Boruszko, D.
Powiązania:
https://bibliotekanauki.pl/articles/1818578.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
odcieki
stabilizacja osadów ściekowych
złoża hydrofitowe
reject water
sewage sludge stabilization
constructed wetland
Opis:
The paper presents author's experience related to reject water treatment with constructed wetland (CW). CW technology is well known worldwide to treat municipal wastewater, rainwater and also industrial wastewater. The problem with reject water is mainly concerning high concentration of ammonia nitrogen. It is observed mainly in municipal WWTPs utilizing anaerobic sewage sludge stabilization. Dairy WWTP belonging to Mlekovita was modernized in 2013 with implementation of flotation process in wastewater line and anaerobic stabilization of excess and flotation sludge. Probably this is the biggest dairy WWTP in Poland. It is operating (July 2014) with 6886 m3/d and personal equivalent about 278 000 (project was done for PE 35 0000 and maximum flow 75000 m3/d). Reject water as a byproduct like sewage sludge is returned to the beginning of wastewater line. During own research with reject water it was found that concentration of ammonia nitrogen was varied from 291 N-NH4+/dm3to 423 mg N-NH4+/dm3. while value of BOD5 from 132 to 185 mg O2/dm3. Laboratory scale investigation was carried out with vertical flow CW model with total depth 0,65 m. filled with gravel and sand. Two hydraulic loads were applied during investigations – 0,1 and 0,2 m/d. The temperature during two series was changing from 22,0 do 26,0°C. High efficiency of BOD5 removal (up to 91%) from reject water produced in dairy WWTP was observed. The efficiency of ammonia nitrogen removal was varied from 78,3% to 90,0%. The efficiency of total phosphorus removal was low in both series. Vertical flow constructed wetland can be used as a low cost method to decrease load of dairy WWTP utilizing anaerobic sewage sludge utilization. To increase efficiency of reject water treatment lower hydraulic load (from 0,05 m/d) should be applied. Future researches will be carried out with real scale installation in Wysokie Mazowieckie equipped with special aeration system to supply vertical flow CW with oxygen.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 2; 869-879
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bilans ścieków, osadów i odcieków w zmodernizowanej oczyszczalni ścieków mleczarskich S.M. Mlekovita
Sewage, sludge and reject water balance in Mlekovita Dairy WWTP after modernization
Autorzy:
Dąbrowski, W.
Boruszko, D.
Kajurek, M
Powiązania:
https://bibliotekanauki.pl/articles/297063.pdf
Data publikacji:
2014
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
ścieki mleczarskie
stabilizacja beztlenowa
odcieki
dairy sewage
sewage sludge
anaerobic stabilization
reject water
Opis:
W artykule przedstawiono problemy związane z modernizacją jednej z największych oczyszczalni ścieków mleczarskich w Polsce. Oczyszczalnia ścieków mleczarskich firmy S.M. Mlekovita w Wysokiem Mazowieckiem została poddana modernizacji, którą zakończono w 2013 roku. Projekt zakładał Równoważną Liczbę Mieszkańców (RLM) na poziomie 350 000 przy przepływie 7500 m3/d. W procesie oczyszczania ścieków stosuje się flotację ciśnieniową. Oczyszczanie biologiczne zachodzi w komorze defosfatacji oraz w dwóch komorach osadu czynnego z zastosowaniem symultanicznej nitryfikacji i denitryfikacji. Stosowane jest także chemiczne usuwanie fosforu. Osad nadmierny, poflotacyjny oraz serwatka są stabilizowane beztlenowo. W pracy przedstawiono badania przeprowadzone w maju 2014 roku, w których określono parametry ścieków dopływających do oczyszczalni oraz odcieków pochodzących z beztlenowej przeróbki osadu nadmiernego, poflotacyjnego oraz serwatki. Stwierdzono bardzo duże obciążenie oczyszczalni ładunkiem zanieczyszczeń zawartym w odciekach z przeróbki osadów, które odprowadzane są do części biologicznej oczyszczalni. Projekt modernizacji nie uwzględnił konieczności ich wydzielonego oczyszczania poza głównym ciągiem biologicznym. Według badań własnych średnia wartość BZT5 w ściekach mleczarskich wynosiła 2738,0 mg O2/dm3 , w przypadku odcieków było to 185,0 mg O2/dm3. Odwrotną tendencję zaobserwowano w przypadku azotu amonowego. Jego stężenie w ściekach mleczarskich wynosiło średnio 4,0 mg N-NH+4/dm3, natomiast w odciekach 340,0 mg N-NH+4/dm3. Uwzględniając ilość ścieków dopływających z mleczarni i miasta oraz ilość odcieków, stwierdzono, że ładunek azotu amonowego zawarty w odciekach jest ponad 3-krotnie wyższy od ładunku zawartego w ściekach mleczarskich i komunalnych. Otrzymane rezultaty potwierdziły celowość badań nad możliwością zastosowania metody hydrofitowej do wydzielonego oczyszczania odcieków w oczyszczalni w Wysokiem Mazowieckiem.
The article presents problems connected with modernization of one of the dairy waste water treatment plants (WWTP) in Poland. The dairy WWTP belonging to Mlekovita Dairy co-operative in Wysokie Mazowieckie is one of the major ones with Personal Equivalent (PE) about 350 000 and average daily flow of 7500 m3 (data for modernization project). In the sewage treatment, dissolved air flotation (DAF) process was implemented, which allowed significant decrease of pollution load discharged to biological treatment. Biological treatment is carried out in biological chambers allowing simultaneous nitrification and denitrification. Aerobic stabilization of sewage sludge in separate chambers was replaced by anaerobic system. Excess sludge, flotation sludge and whey were stabilized simultaneously in anaerobic reactor. Implementation of anaerobic system enabled production of heat and electric energy from biogas. During own research conducted in May 2014, basic parameters of raw dairy waste water, municipal waste water and reject water were determined. Values of BOD, COD and concentration of ammonia nitrogen, total nitrogen and phosphorus were examined in laboratory belonging to Mlekovita and Bialystok University of Technology (BUT). The modernization project did not include separate treatment of reject water before its discharging to biological treatment. During own research average value of BOD in dairy sewage was 2738 mg O2/dm3 and 185 mg O2/dm3 in reject water. In case of total phosphorus it was 44.0 mg P/dm3 in dairy sewage and 41.0 mg P/dm3 in reject water. Reverse tendency was observed in case of ammonia nitrogen concentration which was in average 4.0 mg N-NH+4/dm3.
Źródło:
Inżynieria i Ochrona Środowiska; 2014, 17, 3; 483-491
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Eco-innovative Technologies of Nutrients Removal in Wastewater – Case Study BARITECH Project
Zastosowanie innowacyjnych technologii do usuwania związków biogennych ze ścieków – studium przypadku (BARITECH)
Autorzy:
Kasprzyk, M.
Pierzgalski, K.
Wojciechowska, E.
Obarska-Pempkowiak, H.
Gajewska, M.
Powiązania:
https://bibliotekanauki.pl/articles/1813856.pdf
Data publikacji:
2017
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
nitrogen removal
phosphorus removal
reject water
constructed wetlands
usuwanie azotu
usuwanie fosforu
odcieki
oczyszczalnie hydrofitowe
Opis:
Eco-innovative technologies in wastewater treatment should provide not only stringent standards for the quality of treated wastewater but also ensure maximum recovery of energy and raw materials from wastewater. One of the ways to improve the removal efficiency of nitrogen and phosphorus compounds in existing conventional wastewater treatment plants is pretreatment of reject water generated during the mechanical dewatering of the digested sewage sludge. The aim of this research was to select the technological parameters of processes to ensure effective removal of nutrient elements (N, P) from RW treated in a SBR reactor in the nitritation/anammox process. The study was divided into two stages. The first stage was carried out to optimize nitrogen compounds removal in the effluent from ANAMMOX process used to treat reject water after centrifugation. The installation consists of single vertical subsurface flow (VSSF) beds located in stainless steel containers working parallel marked as BED control “0”, “I”, “II”. Samples have been taken for analysis to determine the changes of NH4-N, NO3-N and NO2-N in the effluent of each filter. In bed “0” the removal of nitrogen compounds was caused only by sorption at last until its capacity was reached. In bed “I” and “II” the NH4-N concentration in effluent and production of NO2-N with simultaneous changes of NO3-N indicated that nitrification was occurring. The investigation has shown different pattern of processes responsible for nitrogen compounds transformation and removal efficiency, depending on the bed substrate and vegetation. In the second stage the optimization of phosphates removal was carried out. The investigation was conducted in steady conditions in laboratory model with four batch reactors. Each batch reactor of synthetic wastewater with given concentration of phosphates (15 mg/dm3) was subjected to mixing. Samples for analyzing were taken from each beaker after assumed time of sedimentation. Studies were conducted to determine the optimal dose of Phoslock® with known concentration of phosphate anions PO43- in model solution, time of mixing and time of sedimentation. Samples were analyzed with following parameters: pH, total suspended solids, conductivity, turbidity, color and phosphate concentration. The carried out investigations confirmed high efficiency of phosphate anions PO443- removal (over 95%). Also study showed no relationship between the mixing time and the degree of reduction of phosphorus compounds.
Innowacyjne technologie stosowane podczas oczyszczania ścieków powinny spełniać nie tylko wysokie wymagania dotyczące jakości oczyszczonych ścieków, ale także zapewnić maksymalny potencjał odzysku energii i surowców z ścieków. Jednym ze sposobów poprawy skuteczności usuwania związków azotu i fosforu w istniejących konwencjonalnych oczyszczalniach ścieków, jest wstępne oczyszczanie odcieków powstających podczas mechanicznego odwadniania osadu ściekowego po biologicznym oczyszczaniu ścieków. Celem badań było określenie charakterystycznych parametrów procesów technologicznych, dla zapewnienia skutecznego usuwania związków biogennych (N, P) ze ścieków po oczyszczaniu w procesie nitryfikacji/anammox zachodzącym w reaktorze typu SBR. Badanie zostało podzielone na dwa etapy. Pierwszy etap przeprowadzono w celu optymalizacji procesu usuwania związków azotu (NH4-N, NO3-N i NO2-N) z odcieków powstających z mechanicznego odwadniania przefermentowanych osadów ściekowych. Odcieki oczyszczane były w reaktorze SBR w procesie ANAMMOX. Instalacja pilotowa składała się z pojedynczych złóż o przepływie pionowym umieszczonych w zbiornikach ze stali nierdzewnej, pracujących równolegle oznaczonych odpowiednio jako złoże "0", "I", "II". Próbki do analizy pobierano w celu określenia zmian NH4-N, NO3-N i NO2-N w ściekach w każdym ze złóż. W złożu "0" (nie zasiedlonym trzciną) usuwanie związków azotu spowodowane było jedynie przed sorpcję, aż do wyczerpania jego pojemności sorpcyjnej. Natomiast zmiany stężenia NH4-N i wytwarzanie NO2-N przy jednoczesnych zmianach stężenia NO3-N wskazywały na zachodzący proces nitryfikacji w złożach "I" i "II" (oba zasiedlone trzciną). Doświadczenia wykazały różne mechanizmy procesów odpowiedzialnych za przemiany związków azotu i skuteczność ich usuwania, w zależności od podłoża i wegetacji. W drugim etapie badań przeprowadzono optymalizację procesu usuwania fosforanów. Natomiast doświadczenia związane z usuwaniem fosforu zostało przeprowadzone w laboratorium w warunkach nieprzepływowych przy zastosowaniu modelu z czterema reaktorami. Każdy reaktor zawierający ścieki syntetyczne o stężeniu fosforanów 15 mg/dm3 poddano mieszaniu. Próbki do analizy zostały pobierane z każdej zlewki po założonym czasie sedymentacji. Badania przeprowadzono w celu określenia optymalnej dawki preparatu Phoslock® przy znanym stężeniu anionów fosforanowych PO43- w roztworze modelowym, oraz znalezienia optymalnego czasu mieszania i sedymentacji. Próbki poddano analizie i określono następujące parametry: pH, zawiesinę, przewodnictwo, mętność, barwę i stężenie fosforanów. Przeprowadzone badania potwierdziły wysoką skuteczność usuwania PO43- (ponad 95%). Badanie nie wykazało zależności między czasem mieszania a stopniem redukcji związków fosforu.
Źródło:
Rocznik Ochrona Środowiska; 2017, Tom 19; 143-160
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiany składu materii organicznej podczas oczyszczania ścieków komunalnych
Changes in organic matter composition during municipal sewage treatment
Autorzy:
Przywara, L.
Adamiec, A.
Powiązania:
https://bibliotekanauki.pl/articles/127545.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
materia organiczna
frakcje ChZT
wody odpadowe
przeróbka osadów
odcieki
organic matter
COD fractions
reject water
Opis:
Efektywność oczyszczania ścieków zależy nie tylko od zastosowanej technologii dostosowanej do jakości dopływających ścieków surowych, ale również od problemów eksploatacyjnych czy gospodarki wodami osadowymi. Obecnie oczyszczalnie nie stosują metod wydzielonego oczyszczania odcieków powstających w trakcie przeróbki osadów i są zawracane na początek ciągu technologicznego oczyszczalni. Wody osadowe ze względu na zawartość substancji organicznej niepodatnej na biodegradację mogą wpływać na efektywność realizowanych procesów oczyszczania. Dlatego też ważne jest nie tylko określenie ogólnej zawartości związków organicznych w ściekach, ale również dokonanie szczegółowej charakterystyki substancji organicznych przez wyznaczenie frakcji ChZT. W niniejszych badaniach przeanalizowano przemiany materii organicznej podczas oczyszczania ścieków w kolejnych etapach mechaniczno-biologicznego oczyszczania ścieków, dokonując analizy składu frakcyjnego materii organicznej. Badania prowadzono na ściekach pochodzących z oczyszczalni pracującej w technologii zintegrowanego usuwania związków organicznych i biogennych. Wykazano m.in., że cyrkulacja odcieków powstających podczas odwadniania osadów powodowała wzrost stężenia trudno rozkładalnej substancji organicznej. Podczas mechaniczno-biologicznego procesu oczyszczania całkowicie uległy zmianie proporcje frakcji Si, Ss, Xi, Xs. Dominującą frakcją w ściekach oczyszczonych była frakcja związków rozpuszczonych nieulegających biologicznemu rozkładowi przez mikroorganizmy - Si. Łącznie frakcje inertne (Si i Xi) w ściekach oczyszczonych stanowiły 76,4% całkowitego ChZT. Udział frakcji Xi na poziomie 16,3% całkowitego ChZT w ściekach oczyszczonych pozwala stwierdzić, że zachodzące procesy oczyszczania działają z dużą efektywnością, na które nie mają wpływu doprowadzane wody osadowe.
Efficiency of wastewater treatment depends not only on the applied technology of wastewater treated, but also on processing problems and management of reject water. Currently, treatment plants do not use methods of separate treatment of reject water generated during the processing of sludge and such residues are returned to the beginning of technological process of treatment. Reject water due to the content of non-biodegradable organic matter can affect the efficiency of the purification process. Therefore, it is important not only to determine the overall content of organic compounds in wastewater, but also the specific characteristics of organic substances, by determining of COD fractions. In this study, fractional composition of organic matter during wastewater treatment in the subsequent stages of mechanical and biological wastewater treatment was analyzed. The wastewater used originated from the plant using integrated removal of organic and biogenic compounds. The circulation of reject water formed during dewatering of sediments, resulted in an increase in the concentration of the hardlybiodegradable organic matter. During mechanical/biological phase of wastewater treatment, the proportions of Si, Ss, Xi, Xs fractions were completely changed. The dominant fraction in purified effluents was a fraction of dissolved and non-biodegradable compounds Si. In total, Si and Xi inert fractions in purified effluent accounted for 76% of the total COD. The fraction of Xi, in purified effluent, in case of processes not influenced by recirculated reject water, amounted for 16% of the total COD. This shows that the cleaning processes occurs with high effectiveness.
Źródło:
Proceedings of ECOpole; 2017, 11, 2; 571-580
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Removal of Organic and Biogenic Compounds from Reject Water with Constructed Wetlands
Usuwanie substancji organicznej oraz związków biogennych z odcieków metodą hydrofitową
Autorzy:
Dąbrowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/389181.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
odcieki
złoża hydrofitowe
biogeny
związki organiczne
reject water
constructed wetlands
biogenic
nutrients and organic substances
Opis:
There are 16 dairy processing plants operating in Podlasie region, including 9 that use individual systems for sewage treatment, while others dispose wastewaters to municipal wastewater treatment plants. Personal Equivalent (P.E.) for individual objects ranges from 7000 to almost 240000 at the flow rate from 500 up to 5240 m3 of sewage daily. Most of objects were built in 70’s of the 20th century; they are overloaded due to the increase of production in factories and works observed for over 20 years. The increase of sewage load made also the increase of sewage sludge and reject water amounts. Reject water is in general directed to the beginning of the treatment process, which is a considerable load, namely due to ammonium nitrogen form. Applying the separate reject water treatment using constructed wetland is one of the possibilities to lower the dairy sewage treatment plant loads. The method can be an alternative for advanced and expensive technologies for purifying the reject waters from treatment plants that use anaerobic sludge stabilization. Studies were carried out in August–October 2008 in research installation designed by the author and operating in dairy sewage treatment plant in Bielsk Podlaski. Reject waters generated in sewage sludge thickening chamber were subject to purification. Mean pollutants concentrations in reject water were: BOD5 – 118.6 mg O2 dm–3, COD – 242.1 mg O2 dm–3, Kjeldahl’s nitrogen – 17.2 mg NTKN dm–3, ammonium nitrogen – 10.4 mg N dm–3, and total phosphorus – 7.2 mg PT dm–3. BOD5 removal efficiency was 69.4 %, COD 53.7 %, Kjeldahl’s nitrogen 55.8 %, ammonium nitrogen 72.1 %, and total phosphorus 19.4 %, on average. Mean effect of organic substance removal measured as BOD5 was achieved at the level of 20.6 g BOD5 m–2 d–1, while ammonium nitrogen 1.87 g N–NH4 m–2 d–1. The study confirmed the usefulness of constructed wetland method application for separate treatment the reject waters from aerobic sewage sludge stabilization. At present, studies on the object designed for reject waters purification for a real scale, were begun. It is the first object of that type, installed in dairy sewage treatment plant in Poland, and it was designed as a result of the research work realized by the author in 2007–2009.
W województwie podlaskim działa 16 zakładów przetwórstwa mleczarskiego, z których 9 korzysta z indywidualnych systemów oczyszczania ścieków, pozostałe zaś odprowadzają ścieki do oczyszczalni komunalnych. Równoważna Liczba Mieszkańców (RLM) dla obiektów indywidualnych waha się od 7000 do niemal 240000, przy przepływie od 500 do 5500 m3 ścieków na dobę. Większość obiektów pochodzi z lat 70. ubiegłego wieku. Są one przeciążone ładunkiem zanieczyszczeń ze względu na wzrost produkcji w zakładach obserwowany od ponad 20 lat. Wzrost ładunku ścieków spowodował zwiększenie ilości osadów ściekowych oraz odcieków z ich przeróbki. Odcieki są z reguły kierowane na początek procesu oczyszczania, stanowiąc znaczne obciążenie, szczególnie w odniesieniu do azotu amonowego. Jedną z możliwości zmniejszenia obciążenia oczyszczalni mleczarskiej jest zastosowanie wydzielonego oczyszczania odcieków z wykorzystaniem metody hydrofitowej. Metoda ta może stanowić alternatywę dla zaawansowanych i kosztownych technologii przeznaczonych do oczyszczania odcieków z oczyszczalni stosujących beztlenowa stabilizację osadów. Wykonane w okresie sierpień-październik 2008 r. badania przeprowadzono dla instalacji badawczej zaprojektowaną przez autora i działającą na terenie oczyszczalni ścieków mleczarskich w Bielsku Podlaskim. Oczyszczaniu poddano odcieki powstające w komorze zagęszczania osadu. Wartości średnie wskaźników zanieczyszczeń w odciekach poddanych oczyszczaniu wynosiły: BZT5 - 118,6 mg O2 dm-3, ChZT - 242,1 mg O2 dm-3, azot Kjeldahla - 17,2 mg NTKN dm-3, azot amonowy - 10,4 mg N dm-3 oraz fosfor całkowity - 7,2 mg PT dm-3. Średnia efektywność usuwania wynosiła 69,4% BZT5, 53,7% ChZT, 55,8% azotu Kjeldahla, 72,1% azotu amonowego i 19,4% fosforu całkowitego. Osiągnięto średni efekt usuwania substancji organicznej mierzonej przez BZT5 na poziomie 20,6 BZT5 m-2 d-1, natomiast azotu amonowego 1,87 g N-NH4 m-2 d-1. Na podstawie uzyskanych wyników stwierdzono możliwość zastosowania metody hydrofitowej do wydzielonego oczyszczania odcieków z tlenowej przeróbki osadów ściekowych. Obecnie rozpoczęto badania na obiekcie zaprojektowanym do oczyszczania odcieków w skali rzeczywistej. Jest to pierwszy tego typu obiekt w oczyszczalni mleczarskiej na terenie Polski, który powstał jako wdrożenie wyniku pracy badawczej zrealizowanej przez autora w latach 2007-2009.
Źródło:
Ecological Chemistry and Engineering. A; 2011, 18, 9-10; 1203-1210
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka ścieków i osadów z oczyszczalni komunalnej stosującej technologię firmy „Biopax”
The quality of sewage and sewage sludge from the municipal wastewater treatment plant using „Biopax” technology
Autorzy:
Królak, E.
Biardzka, E.
Bramowicz, D.
Powiązania:
https://bibliotekanauki.pl/articles/401786.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ścieki
osady
odcieki
efektywność oczyszczania
technologia firmy „BIOPAX”
sewage
sewage sludge
reject water
efficiency
BIOPAX technology
Opis:
Celem badań była ocena redukcji zanieczyszczeń w ściekach komunalnych oraz analiza składu chemicznego osadów ściekowych i odcieków w komunalnej oczyszczalni w Komorach Dąbrownych. Oczyszczanie ścieków oparte jest na technologii firmy BIOPAX. Ocenie poddano odczyn oraz stężenie biogenów w ściekach surowych i oczyszczonych, zawartość materii organicznej oraz azotu i fosforu całkowitego w osadach uwodnionych i ustabilizowanych. Określono także skład odcieków. Stwierdzono, że zastosowana technologia zapewnia skuteczną (na poziomie powyżej 96%) redukcję biogenów w ściekach. Skład chemiczny osadów ściekowych po ich stabilizacji jest typowy dla osadów wytwarzanych w komunalnych oczyszczalniach ścieków, a odcieki włączane do procesu technologicznego nie wpływają negatywnie na proces technologiczny. Ze względu na wysoką redukcję biogenów oczyszczalnie oparte na opisanej technologii wydają się być dobrym rozwiązaniem dla oczyszczania ścieków w małych miejscowościach.
The aim of the study was the assessment of contaminants reduction from communal sewage and the analysis of the chemical composition of sewage sludge and reject waters from Komory Dąbrowne sewage treatment plant using devices designed and built by BIOPAX Ltd. The scope of the research included assessing the following aspects: reaction (pH), the concentration of nutrients in raw and treated sewage, the concentration of organic matter and the content of total nitrogen and phosphorus in sludge before and after stabilization. The characteristic of reject water was also presented. It was found that technology provides more than 96% reduction of nutrients from the sewage. Chemical composition of stabilized sewage sludge is similar to the communal waste produced in other sewage treatment plants, while the reject waters used in the treatment process do not influence the technological process in an adverse way. Due to its high capacity of nutrient reduction, technology seems to be a useful tool to be applied in small municipal wastewater treatment plants (WWTPs).
Źródło:
Inżynieria Ekologiczna; 2016, 48; 119-124
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Chrakterystyka odcieków z tlenowej przeróbki osadów w komunalnych i przemysłowych oczyszczalniach województwa podlaskiego
Characteristics of reject water from aerobic sludge stabilization process in municipal and industrial wastewater treatment plants locted in Podlaskie province
Autorzy:
Dąbrowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/297783.pdf
Data publikacji:
2010
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
odcieki
przeróbka osadów
stabilizacja tlenowa
ścieki komunalne
reject water
sewage sludge treatment
aerobic stabilization
municipal wastewater
Opis:
Według danych z 2008 roku, na terenie województwa podlaskiego działało 112 oczyszczalni komunalnych, z czego tylko trzy stosują stabilizację beztlenową. Oczyszczalnie nie stosują metod wydzielonego oczyszczania odcieków powstających w trakcie przeróbki osadów. Stwarza to szereg problemów ze stabilną pracą systemów oczyszczania. W latach 2007- 2009 prowadzono badania dotyczące możliwości wydzielonego oczyszczania odcieków z oczyszczalni mleczarskich przy zastosowaniu metody hydrofitowej. Efektem tych badań jest wdrożenie na jednej z oczyszczalni mleczarskich oraz zgłoszenie patentowe dotyczące wykorzystania poletek osadowych do budowy pionowych złóż hydrofitowych jako elementu podczyszczalni odcieków. Ze względu na zbliżony charakter ścieków komunalnych i mleczarskich w 2009 roku rozpoczęto badania, które miały na celu określenie składu odcieków powstających w oczyszczalniach komunalnych stosujących wydzieloną stabilizację tlenową. Badania prowadzono na dwóch obiektach o zbliżonej przepustowości i podobnym systemie przeróbki osadów ściekowych. Ilość odcieków wahała się od 2,1 do 2,9% w stosunku do ilości dopływających ścieków. Średnie wartości podstawowych parametrów odcieków w dwóch analizowanych oczyszczalniach według badań z 2009 i 2010 roku wynosiły: BZT5 (185 ÷ 290 mgO2/l), azot amonowy (56,4 ÷ 96,5 mgN-NH4/l), fosfor ogólny (9,6 ÷ 11,2 mgP/l). Badania potwierdziły, iż ze względu na skład odcieków z tlenowej stabilizacji osadów potencjalnie możliwe będzie zastosowanie wydzielonego ich oczyszczania metodą hydrofitową.
Aerobic stabilization of sewage sludge is a universally applied process used in municipal and industrial wastewater treatment plants (WWTP). According to an analysis from 2008 regarding systems currently working in Podlaskie province the following preliminary observations were made: amongst 112 municipal WWTP there are only three plants which apply anaerobic sewage sludge stabilization and only one plant amongst 30 industrial WWTP. Obtained biogas is used for heat and electric energy production. An issue of reject water from sludge treatment concerns plants applying both aerobic and anaerobic stabilization. Reject water is usually turned back to the beginning of the treatment system without any separated treatment. It causes problems with stable performance of municipal WWTP. In the years 2007-2009 author conducted a research project "Evaluation of usefulness of constructed wetlands to purify reject water from sludge aerobic processing in dairy wastewater treatment plants". The separated treatment of reject water was processed with the use of vertical and horizontal constructed wetlands and hybrid systems. The results from the research project were used in construction of dairy wastewater treatment plant. The following solution of utilization of sludge drying bed for vertical wetlands construction as an element of reject water pretreatment was filed for patent protection. Due to similar characteristics between municipal and dairy sewages a new research project took off in 2009 aimed to find out quantity and quality of reject water from municipal WWTP that apply a separated aerobic sewage sludge stabilization. Eventually it is planned to apply vertical constructed wetland system to treat reject water in these wastewater treatment plants. Research studies presented in this paper were conducted in two plants with similar flow capacity of about 5000 m³/d, sewage treatment of high biological efficiency and chemical removal of C, N, P. Person equivalent (P.E.) varied from 25800 to 42750. Excess sludge was condensed by means of gravitational thickener and stabilized in separated aerobic chambers with deep aeration system. Primary in the 70-th of the XX century both plants were operating with open anaerobic stabilization chambers. System was rebuilt during modernization in the end of century. The quantity of reject water from thickening, dewatering and aerobic stabilization varied from 2.1 to 2.9% of the total quantity of raw sewage. Mean pollution concentrations in reject water were: BOD5 (185 ÷ 290 mgO2/l), COD (290 ÷ 790 mgO2/l), TKN (53.9 ÷ 89.5 mgN/l), ammonia nitrogen (36.4 ÷ 76.5 mgN-NH4/l), total phosphorus (9.6 ÷ 11.2 mgP/l). Mean pollution concentrations raw wastewater were: BOD5 (310 ÷ 570 mgO2/l), COD (860 ÷ 1157 mgO2/l), TKN (55.2 ÷ 104.0 mgN/l), ammonia nitrogen (56.4 ÷ 96.5 mgN-NH+4/l), total phosphorus (9.0 ÷ 9.6 mgP/l). The load of ammonia nitrogen in total load in raw sewage varied from 2.8 to 4.9% while BOD5 from 1.1 to 1.7%. Research studies confirmed that because of composition of reject water from aerobic stabilization it is possible to treat it by means of constructed wetlands.
Źródło:
Inżynieria i Ochrona Środowiska; 2010, 13, 1; 43-51
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies