Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "bioaerozol" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Wpływ aerozolu biologicznego z oczyszczalni ścieków na zdrowie pracowników i okolicznych mieszkańców – analiza literaturowa
Influence of biological aerosol from wastewater treatment plants on workers and the local residents health – literature review
Autorzy:
Michalak, Aleksandra
Pawlas, Krystyna
Powiązania:
https://bibliotekanauki.pl/articles/1178754.pdf
Data publikacji:
2012
Wydawca:
Instytut Medycyny Wsi
Tematy:
bioaerozol
oczyszczalnia ścieków
zdrowie pracowników i mieszkańców
Opis:
Bioaerosol forms microbes, their toxins and fragments of microorganisms suspended as small droplets or solid particles. The group particularly exposed are workers of sewage treatment plants and local residents. Literature reports stress the role of the fecal bacteria from the Enterobacteriaceae family and yeasts, which create a real risk of air pollution near the waste water treatment plants Emission of pathogenic microbes prevails in the neighbourhood of of sedimentation tanks, sludge drying beds. Research shows that the extent of bioaerosol influence reaches the distance of 3 km away from any waster water treatment plant.. The most frequent symptoms reported by workers from waste water treatment plants and local residents are respiratory disorders. There are also gastrointestinal and skin problems and general disorders, that can be explained by exposure to endotoxins in bioaerosol.
Aerozol biologiczny tworzą drobnoustroje, ich toksyny oraz fragmenty mikroorganizmów zawieszone w postaci drobnych kropel lub cząstek stałych. Szczególnie eksponowani na jego działanie są pracownicy oczyszczalni ścieków oraz okoliczni mieszkańcy. Doniesienia literaturowe zwracają uwagę na rolę bakterii kałowych z rodziny Enterobacteriaceae oraz drożdży, które stwarzają rzeczywiste zagrożenie czystości sanitarnej powietrza przy oczyszczalniach. Emisja drobnoustrojów chorobotwórczych przeważa w sąsiedztwie obiektów związanych z osadami (zbiorniki gromadzenia osadu, poletka osadowe). Badania naukowe wskazują, że zasięg oddziaływania bioaerozolu sięga do 3 km poza teren oczyszczalni. Do najczęściej zgłaszanych objawów przez pracowników oczyszczalni ścieków oraz mieszkańców terenów przyległych, należą dolegliwości związane z układem oddechowym. Pojawiają się również zaburzenia gastryczne, skórne oraz objawy ogólne, których występowanie można tłumaczyć ekspozycją na endotoksyny obecne w bioaerozolu.
Źródło:
Medycyna Środowiskowa - Environmental Medicine; 2012, 15, 4; 116-122
1505-7054
2084-6312
Pojawia się w:
Medycyna Środowiskowa - Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena mikrobiologicznego zanieczyszczenia powietrza na terenie oczyszczalni ścieków
An assessment of microbiological air pollution at the sewage treatment plant
Autorzy:
Breza-Boruta, B.
Powiązania:
https://bibliotekanauki.pl/articles/339182.pdf
Data publikacji:
2010
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
bioaerozol
oczyszczalnia ścieków
powietrze
air
bioaerosol
sewage treatment plant
Opis:
Przeprowadzono monitoringowe badania składu bioaerozolu bakteryjnego i mikrogrzybowego na terenie Oczyszczalni Ścieków Komunalnych "Igły" w Chojnicach. Analizy mikrobiologiczne powietrza wykonano w okresie letnim 2008 r. na czterech stanowiskach: przy piaskownikach, komorach napowietrzania, w miejscu składowania dojrzewającego kompostu i 150 m poza oczyszczalnią. Ogólna liczba bakterii wynosiła 10²-104 jtk·m-³ i tylko przy piaskownikach stwierdzono silne zanieczyszczenie powietrza. Największym emitorem bakterii wskaźnikowych P. fluorescens, pałeczek Salmonella sp. oraz paciorkowców kałowych również okazały się piaskowniki. Koncentracja grzybów pleśniowych była mała (maksymalnie 4 600 jtk·m-³) i na wszystkich stanowiskach nie przekraczała wartości, wskazujących na zanieczyszczenie powietrza. W przypadku promieniowców silne skażenie powietrza odnotowano jedynie przy pryzmach kompostowych. Gronkowce, zarówno mannitolododatnie, jak i mannitoloujemne, we wszystkich punktach przyczyniły się do średniego zanieczyszczenia powietrza. Pałeczki E. coli wykryto na dwóch stanowiskach – przy piaskownikach (92,5 jtk·m-³) i komorach napowietrzania (2,5 jtk·m-³). Na podstawie wyników uzyskanych w punkcie poza obiektem stwierdzono średnie zanieczyszczenie powietrza przez promieniowce, P. fluorescens oraz gronkowce, ponadto wykryto bakterie z rodzaju Salmonella i Enterococcus, co może świadczyć o skażeniu powietrza w najbliższym otoczeniu oczyszczalni ścieków.
Monitoring of the content of bacterial and microfungal bioaerosol was carried out at the Municipal Sewage Treatment Plant "Igły" in Chojnice. Microbiological analyses of the air were carried out in the summer period 2008 at four stands: in the vicinity of sand catchers, aeration chambers, maturing compost piles and at a distance of about 150 m from the treatment plant. The total number of bacteria remained within the range of 10²-104 cfu·m-³ and heavy air pollution occurred only by sand catchers. Concentration of mould fungi reached up to 4 600 cfu·m-³, which indicated unpolluted air at all stands. Sand catchers proved to be the largest emission source of indicator bacteria P. fluorescens, Salmonella sp. and fecal streptococci. In the case of actinomycetes, a heavy air pollution was noted at compost piles. Both mannitol-positive and mannitol-negative staphylococci at all points contributed to moderate air pollution. E. coli bacilli were isolated from two stands: near sand catchers (92.5 cfu·m-³) and aeration chambers (2.5 cfu·m-³). Moderate air pollution with actinomycetes, P. fluorescens and staphylococci was found outside the sewage treatment plant. Moreover, bacteria of the genera Salmonella and Enterococcus were detected, which may evidence air pollution in the immediate vicinity of the treatment plant.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2010, 10, 3; 49-57
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microbiological hazards in closed facilities at sewage treatment plants
Zagrożenia mikrobiologiczne w zamkniętych obiektach oczyszczalni ścieków
Autorzy:
Polus, Michał
Mucha, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/205210.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
bioaerosols
sewage treatment plant
microbiological hazards
bioaerozol
oczyszczalnia ścieków
zagrożenia mikrobiologiczne
Opis:
In this work microbiological air pollution at several commune sewage treatment plants (capacity up to 15,000 PE) was investigated. The bioreactors in all plants had a covered construction. The air samples were taken indoors as well as outdoors (both on the windward and leeward side) during different seasons. The samples were collected using the collision method. The presence of indicator organisms in the samples was determined according to the Polish Standards. Identification of individual indicators was performed on solid selective-differentiating substrates. To verify the presence of bacteria from Salmonella, Shigella, coliforms and enterococci species, the colonies observed on the MacConkey substrate were then sifted onto SS and Endo substrates. At all facilities (with one exception) the average CFU for the total number of bacteria and fungi did not exceed 1000/m3, which is the limit set by the Polish Standards for a pollution-free atmospheric air. Bacteria and fungi concentrations, observed at windward and leeward sides of all plants, were relatively low (<100 CFU/m3 and <1000 CFU/m3, respectively) and comparable. A sewage collection point had only a slight impact on the bioaerosol emission. The concentration of microorganisms in the immediate vicinity of covered reactors (aeration chambers) was rather low and remained below the limits sets by the Polish Standards at three facilities. The CFU of individual indicators, measured in rooms accessible for the personnel, was comparable to the CFU in technological rooms. However some indicators, e.g. a number of Actinomycetes, were significantly higher and reached >100 CFU/m3, which means significant air pollution. Similarly, the CFU of hemolytic bacteria had nonzero values. The only place where higher concentrations of bioaerosol were found was the centrifuge room, where digested sludge was dewatered. The number of fungi stayed below the limits there, but the amount of heterotrophic and hemolytic bacteria exceeded the limits and reached the values of ~10000 CFU/m3 and 800 CFU/m3, respectively; it means that the personnel working in this area is exposed to microbiological agents.
W pracy poddano obserwacji stopień zanieczyszczenia mikrobiologicznego w pomieszczeniach czterech oczyszczalni ścieków obsługujących poniżej 15000 RLM, posiadających obiekty socjalne i sterownie zintegrowane z obiektami technologicznymi. Ponieważ większość publikowanych dotąd prac skupiała się na dużych obiektach, autorzy starali się monitorować i oceniać stężenie mikroorganizmów w pomieszczeniach zamkniętych małych obiektów. Próbki powietrza z poszczególnych pomieszczeń (reaktor, stacja mechanicznego oczyszczania, stacja odwadniania osadu, pomieszczenia socjalne/sterownie) oraz na zewnątrz obiektów pobierano metodą zderzeniową na podłoża mikrobiologiczne przewidziane przez Polską Normę. Oznaczano wszystkie wymagane wskaźniki mikrobiologiczne. We wszystkich obiektach (z jednym wyjątkiem) średnia liczba jtk/m3 bakterii i grzybów nie przekraczała 1000/m3, a więc była poniżej limitu ustalonego w Polskich Normach dla czystego powietrza atmosferycznego. Stężenia bakterii i grzybów obserwowane na nawietrznych i zawietrznych stronach wszystkich oczyszczalni były stosunkowo niskie (<100 jtk/m3 i <1000 jtk/m3). Punkt odbioru ścieków miał tylko niewielki wpływ na emisję bioaerozolu. Stężenie mikroorganizmów w bezpośrednim sąsiedztwie reaktorów krytych (komór napowietrzania) było raczej niskie i pozostawało poniżej limitów określonych przez Polskie Normy. Wartość poszczególnych wskaźników, mierzona w pomieszczeniach dostępnych dla personelu, była porównywalna z jtk/m3 w pomieszczeniach technologicznych. Jednak niektóre wskaźniki, np. liczba promieniowców były podwyższone i przekraczały 100 jtk/m3, co oznacza znaczne zanieczyszczenie powietrza. Podobnie liczba jtk/m3 bakterii hemolitycznych była niezerowa. Jedynym miejscem, w którym znaleziono wyższe stężenia bioaerozolu, było pomieszczenie wirówki do odwadniania osadu. Liczba bakterii heterotroficznych i hemolitycznych osiągnęła wartości odpowiednio ~10000 jtk/m3 i 800 jtk/m3. Oznacza to, że personel pracujący w tym obszarze jest narażony na działanie czynników mikrobiologicznych. Obecność bakterii z rodzajów Salmonella, Shigella, bakterii grupy coli czy enterokoków stwierdzano tylko sporadycznie.
Źródło:
Archives of Environmental Protection; 2019, 45, 2; 58-65
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of a Small Wastewater Treatment Plant on the Sanitary State of Atmospheric Air
Wpływ małej oczyszczalni ścieków na stan sanitarny powietrza atmosferycznego
Autorzy:
Jadczyk, Piotr
Sówka, Izabela
Pawnuk, Marcin
Wroniszewska, Alicja
Powiązania:
https://bibliotekanauki.pl/articles/1811649.pdf
Data publikacji:
2020
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
bioaerosol
bacteria
fungi
air pollution
wastewater treatment
bioaerozol
bakterie
grzyby
zanieczyszczenie powietrza
oczyszczalnia ścieków
Opis:
Wastewater treatment plants are the source of odour and microorganism emissions to the atmospheric air. Bioaerosol emitted by treatment plants may contain pathogenic microorganisms, antibiotic resistant microorganisms and cause allergies. The aim of the study was to assess the impact of the newly created municipal wastewater treatment plant using the activated sludge method (approx. 20,000 PE, average daily flow of 2,300 m3) on the sanitary state of atmospheric air. Numerous field obstacles (e.g. trees) and natural sources of microorganism emissions to the atmospheric air (e.g. drainage channels) were located in the vicinity of the wastewater treatment plant. Bioaerosol samples (3 replicates) were taken in a wind trail at 10 test stands on the leeward side of the treatment plant and two control stands on the windward side of the treatment plant. Samples were taken by sedimentation on Petri dishes with microbiological mediums. Media was incubated at a temperature appropriate for the type of microorganisms (psychrophilic bacteria, mesophilic bacteria, actinomycetes, mold fungi), and then colonies growing on media were counted. The number of microorganisms per unit volume of air was determined according to the Omelian formula in the Gogoberidze modification. Four series of tests were carried out during the transition months (spring and autumn). The concentration of microorganisms on the leeward side of the treatment plant in the following ranges amouted: psychrophilic bacteria: 156 ± 85 - 6578 ± 1286 cfu/m3, mesophilic bacteria: 87±24 - 6309 ± 1349 cfu/m3, actinomycetes: 0±0 - 719±12 cfu/m3, mold fungi: 52±42 - 4645±425 cfu/m3. These values were similar to those found in the area and in the vicinity of wastewater treatment plants examined by other authors. The concentration of microorganisms in the vicinity of the tested wastewater treatment plant did not show a downward trend as a function of distance from the wastewater treatment plant. This could be due to the presence of other sources of bioaerosol emissions to atmospheric air in the vicinity of the treatment plant (e.g. drainage canals, uncovered soil in plowed fields) and field obstacles that could have affected the movement of air masses (e.g. in-field woodland, forest, embankment Railway). The obtained research results indicate that the emission of bioaerosol from a small wastewater treatment plant, may cause changes in the concentration of microorganisms in the atmospheric air at a level close to natural sources. However, the threats to human health caused by bioaerosol emitted from municipal wastewater may be higher. Therefore, it is justified to monitor the sanitary state of the air and the atmosphere at the wastewater treatment plant and in its vicinity, and conduct research to develop an optimal set of indicator microorganisms of this state.
Oczyszczalnie ścieków są źródłem emisji odorów i mikroorganizmów do powietrza atmosferycznego. Bioaerozol emitowany przez oczyszczalnie może zawierać mikroorganizmy chorobotwórcze, mikroorganizmy oporne na antybiotyki oraz powodować powstawanie alergii. Celem pracy była ocena wpływu nowo powstałej oczyszczalni ścieków komunalnych oczyszczającej je metodą osadu czynnego, (ok. 20000 RLM, średni przepływ dobowy 2300 m3) na stan sanitarny powietrza atmosferycznego. W sąsiedztwie oczyszczalni znajdowały się liczne przeszkody terenowe (np. zadrzewienia) oraz naturalne źródła emisji mikroorganizmów do powietrza atmosferycznego (np. kanały melioracyjne). Próbki bioaerozolu (po 3 powtórzenia) pobierano w smudze wiatru na 10 stanowiskach badawczych po stronie zawietrzenj oczyszczalni i dwóch stanowiskach kontrolnych po stronie nawietrznej oczyszczalni. Próbki pobierano metodą sedymentacyjną na płytki Petriego ze zagaryzowanymi podłożami mikrobiologicznymi. Podłoża inkubowano w temperaturze odpowiedniej dla danego rodzaju mikroorganizmów (bakterie psychrofilne, bakterie mezofilne, promieniowce, grzyby pleśniowe), a potem liczono kolonie rosnące na podłożach. Liczbę mikroorganizmów w jednostce objętości powietrza określano według wzoru Omeliańskiego w modyfikacji Gogoberidze. Wykonano 4 serie badań w miesiącach przejściowych (wiosna i jesień). Stężenia mikroorganizmów po stronie zawietrznej oczyszczalni mieściły się w przedziałach: bakterie psychrofilne: 156±85 - 6578±1286 jtk/m3, bakterie mezofilne: 87±24 - 6309±1349 jtk/m3, promieniowce: 0±0 - 719±12 jtk/m3, grzyby pleśniowe: 52±42 - 4645±425 jtk/m3. Były to wartości zbliżone do stwierdzonych na terenie oraz w sąsiedztwie oczyszczalni ścieków badanych przez innych autorów. Stężenia mikroorganizmów w sąsiedztwie badanej oczyszczalni nie wykazywało tendencji spadkowej w funkcji odległości od oczyszczalni ścieków. Mogło to być spowodowane obecnością w sąsiedztwie oczyszczalni innych źródeł emisji bioaerozolu do powietrza atmosferycznego (np. kanałów melioracyjnych, odkrytej gleby na zaoranych na polach) oraz przeszkód terenowych, które mogły mieć wpływ na przemieszczanie się mas powietrza (np. zadrzewienia śródpolne, las, nasyp kolejowy). Uzyskane wyniki badań wskazują, że emisja bioaerozolu z małej oczyszczalni ścieków, w niektórych przynajmniej przypadka, może powodować zmiany stężenia mikroorganizmów w powietrzu atmosferycznym na poziomie zbliżonym do źródeł naturalnych. Zagrożenia dla zdrowia ludzkiego spowodowane przez bioaerozol emitowany ze ścieków komunalnym mogą być jednak większe. Dlatego uzasadnione jest monitorowanie stanu sanitarnego powietrza atmosferycznego na terenie oczyszczalni ścieków i w ich sąsiedztwie oraz prowadzenie badań nad opracowaniem optymalnego zestawu mikroorganizmów wskaźnikowych tego stanu.
Źródło:
Rocznik Ochrona Środowiska; 2020, Tom 22, cz. 2; 927-939
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of microbial contamination of atmospheric air in a selected wastewater treatment plant
Ocena skażenia mikrobiologicznego powietrza atmosferycznego w wybranej oczyszczalni ścieków
Autorzy:
Paśmionka, Iwona B.
Powiązania:
https://bibliotekanauki.pl/articles/204604.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
microbial contamination
bioaerosol
sewage treatment plant
atmospheric air
skażenie mikrobiologiczne
bioaerozol
oczyszczalnia ścieków
powietrze atmosferyczne
Opis:
The aim of the research was to determine the microbiological quality of atmospheric air in the Tuchów Sewage Treatment Plant, based on the presence of mesophilic bacteria, α- and β-hemolytic bacteria, actinomycetes and fungi. Bioaerosol measurements were made at four points (raw sewage inlet, aeration chamber, purified sewage outlet and 150 m from the treatment plant, at the background point) in the period from January to December 2018. Bioaerosol samples were collected using Andersen’s 6-stage cascade impactor. The tested atmospheric air was characterized by a qualitatively and quantitatively diverse microflora. The highest amounts of all the studied groups of microorganisms were found at the raw sewage inlet, and in the case of actinomycetes, also twice in the place of biological purification. However, there were analyzes in which a higher concentration of microorganisms was observed outside the treatment plant at the control point constituting the background. This applies to bacteria and fungi. The largest source of emission of microorganisms to the atmosphere was the mechanical part of the sewage treatment plant (raw sewage inlet). The tested treatment plant may therefore contribute to the deterioration of the quality of the atmospheric air.
Celem prowadzonych badań było określenie jakości mikrobiologicznej powietrza atmosferycznego na terenie Oczyszczalni Ścieków w Tuchowie, na podstawie występowania bakterii mezofilnych, bakterii α- and β-hemolizujących, promieniowców i grzybów. Pomiary bioaerozolu wykonano w czterech punktach (wlot ścieków surowych, komora napowietrzania, wylot ścieków oczyszczonych oraz 150 m od oczyszczalni, w punkcie stanowiącym tło) w okresie od stycznia do grudnia 2018 r. Próbki bioaerozolu pobierano za pomocą 6-stopniowego impaktora kaskadowego Andersena. Badane powietrze atmosferyczne charakteryzowało się zróżnicowaną ilościowo i jakościowo mikroflorą. Najwyższe ilości wszystkich badanych grup mikroorganizmów stwierdzono przy wlocie ścieków surowych, a w przypadku promieniowców również dwukrotnie w miejscu biologicznego oczyszczania. Zdarzały się jednak analizy, w których wyższe stężenie drobnoustrojów obserwowano poza terenem oczyszczalni, w punkcie kontrolnym stanowiącym tło. Dotyczyło to bakterii i grzybów. Największym źródłem emisji mikroorganizmów do atmosfery była mechaniczna część oczyszczalni (wlot ścieków surowych). Badana oczyszczalnia może więc przyczyniać się do pogorszenia jakości powietrza atmosferycznego.
Źródło:
Archives of Environmental Protection; 2019, 45, 4; 60-67
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena stanu sanitarnego powietrza w otoczeniu wybranej oczyszczalni ścieków
Assessing air quality in the proximity of a municipal sewage treatment plant: A case study
Autorzy:
Kołwzan, B.
Jadczyk, P.
Pasternak, G.
Głuszczak, J.
Pawlik, M.
Krawczyńska, M.
Klein, J.
Rybak, J.
Powiązania:
https://bibliotekanauki.pl/articles/236866.pdf
Data publikacji:
2012
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczalnia ścieków
powietrze atmosferyczne
bioaerozol
bakterie
grzyby mikroskopowe
sewage treatment plant
air pollution
bioaerosol
bacteria
fungi
Opis:
Omówiono wyniki badań mikrobiologicznych powietrza na terenie sąsiadującym z miejską oczyszczalnią ścieków. Pomiary wykonano w latach 2011-2012, uwzględniając wszystkie pory roku. Podstawą do klasyfikacji stopnia mikrobiologicznego zanieczyszczenia powietrza była liczba bakterii mezofilnych, promieniowców, Pseudomonas fluorescens, gronkowców [alfa]- i [beta]-hemolizujących oraz zarodników grzybów. Wykazano, że liczba mikroorganizmów w powietrzu w otoczeniu oczyszczalni ścieków zależała od pory roku i była bardzo zróżnicowana na poszczególnych stanowiskach badawczych, w wielu przypadkach przekraczając wartości charakterystyczne w powietrzu niezanieczyszczonym. Najwięcej drobnoustrojów w powietrzu stwierdzono latem i jesienią, natomiast najmniejsze wartości oznaczono zimą, z uwagi na niską temperaturę ograniczającą przeżywalność mikroorganizmów. Jednocześnie zaobserwowano wyraźny wzrost liczby mikroorganizmów po stronie zawietrznej. Uzyskane wyniki oraz dane literaturowe potwierdzają potrzebę hermetyzowania obiektów oczyszczalni ścieków, a także objęcia ich systematycznym monitoringiem stanu sanitarnego powietrza atmosferycznego.
Air in the vicinity of a municipal sewage treatment plant was assessed for microbial quality. Measurements were carried out in the time span of 2011 and 2012, taking into account seasonal patterns of change. Classification of the extent of microbial contamination was based on the number of mesophilic bacteria, actinomycetes, Pseudomonas fluorescens, [alpha]- and [beta]-hemolyzing staphylococci, and fungal spores. It was demonstrated that the number of airborne microorganisms in the vicinity of the sewage treatment plant followed a seasonal pattern and differed from one measuring point to another, in many instances exceeding the characteristic values measured in unpolluted air. The highest number of microorganisms were determined in summer and fall, and the lowest in winter, when low air temperature limited microbial viability. Simultaneously, a noticeable increase in microbial numbers was observed on the lee side. The results obtained in this study, as well as the available literature data, substantiate the need for hermetizing the objects of the sewage treatment plant and subjecting them to periodical air quality monitoring.
Źródło:
Ochrona Środowiska; 2012, 34, 2; 9-14
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies