Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Gryz, M." wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
EU Directive, ICNIRP Guidelines and Polish Legislation on Electromagnetic Fields
Autorzy:
Karpowicz, J.
Hietanen, M.
Gryz, K.
Powiązania:
https://bibliotekanauki.pl/articles/90412.pdf
Data publikacji:
2006
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
electromagnetic fields
occupational exposure
exposure assessment
regulations
pole elektromagnetyczne
prawo
ekspozycja
narażenie zawodowe
dyrektywy
Opis:
This review describes the general provisions of and the philosophy behind European Directive 2004/40/EC and ICNIRP (International Commission on Non-Ionizing Radiation Protection) guidelines. As an example of national legislation on the protection of workers against excessive electromagnetic field exposure, regulations established in Poland are summarized. The problems of a practical implementation of the Directive’s provisions are discussed.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2006, 12, 2; 125-136
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exposure of Workers to Electromagnetic Fields. A Review of Open Questions on Exposure Assessment Techniques
Autorzy:
Mild, K. H.
Alanko, T.
Decat, G.
Falsaperla, R.
Gryz, K.
Hietanen, M.
Karpowicz, J.
Rossi, P.
Sandstrom, M.
Powiązania:
https://bibliotekanauki.pl/articles/91031.pdf
Data publikacji:
2009
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
occupational exposure
exposure assessment
measurements
numerical simulations
safety guidelines
EU directive
compliance testing
medical implants
health examination
Opis:
European Directive 2004/40/EC on occupational exposure to electromagnetic fields (EMF), based on the guidelines of the International Commission on Non-Ionizing Radiation Protection, was to be implemented in the Member States of the European Union by 2008. Because of some unexpected problems the deadline was postponed until 2012. This paper reviews some of the problems identified and presents some suggestions for possible solutions based on the authors’ experience in assessing occupational exposure to EMF. Among the topics discussed are movement in static magnetic fields, ways to time average extreme low frequency signals, the difference between emission and exposure standards, and ways of dealing with those issues.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2009, 15, 1; 3-33
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Environmental safety aspects of using UHF RFID systems in hospitals
Aspekty środowiskowego bezpieczeństwa wykorzystania systemów UHF RFID w szpitalach
Autorzy:
Zradziński, Patryk
Karpowicz, Jolanta
Gryz, Krzysztof
Suarez, Oscar J.
Trillo, Angeles M.
Hernandez, Jose A.
Miguel-Bilbao de, Silvia
Suarez, Samuel D.
Celaya-Echarri, Mikel
Azpilicueta, Leyre
Falcone, Francisco
Ramos, Victoria
Powiązania:
https://bibliotekanauki.pl/articles/2146754.pdf
Data publikacji:
2020
Wydawca:
Indygo Zahir Media
Tematy:
biomedical engineering
environmental engineering
occupational exposure
public health
AIMD
Internet of things
inżynieria biomedyczna
inżynieria środowiska
narażenie zawodowe
zdrowie publiczne
internet rzeczy
Opis:
Various applications of Radio Frequency IDentification (RFID) technology in the medical environment are characterised. The electromagnetic field (EMF) emitted by RFID handheld readers (RFID guns) is characterised and evaluated with respect to humans exposure metrics – the strength of the electric field affecting anyone present near various UHF (ultra-high frequency) RFID guns and the specific absorption rate (SAR) values in their body. UHF RFID systems are the most popular of such systems used in hospitals. The performed studies indicate that the EMF exposure level near the RFID gun antenna and SAR values (a measure of the thermal effects of EMF exposure) caused by exposure from the RFID reader may exceed the limits of the electric field and SAR issued by international guidelines or legislation. Potentially excessive exposure to EMF emitted by UHF RFID readers is not limited to the user of the device, but may also apply to patients or bystanders. Only UHF RFID guns with an EMF emission lower than 1 W may be considered as an insignificant source of human exposure. The use of readers with a radiated power exceeding 1 W requires the evaluation of the EMF level using measurements, and also the evaluation of SAR by numerical modelling in the case of their use in close proximity to humans. In all cases, insufficient electromagnetic immunity of electronic devices (including medical implants) should be considered near RFID guns at least up to half of the reading range away from the RFID reader. The electromagnetic hazards related to the use of RFID guns may be limited by relevant preventive measures, as shown in this paper, together with the principles of an in-situ evaluation of electromagnetic hazards near the UHF RFID guns.
Scharakteryzowano różne zastosowania technologii identyfikacji radiowej (RFID) w środowisku medycznym. Pole elektromagnetyczne emitowane przez ręczne czytniki RFID (RFID guns) zostało scharakteryzowane i ocenione w odniesieniu do miar narażenia ludzi – natężenia pola elektrycznego oddziałującego na osoby znajdujące się w pobliżu różnych czytników RFID UHF (ultrawysokiej częstotliwości) i współczynnika SAR w ich ciele. System UHF RFID jest najpopularniejszym z systemów RFID użytkowanych m.in. w szpitalach. Przeprowadzone badania wskazują, że poziom ekspozycji na pole elektromagnetyczne w pobliżu anteny ręcznego czytnika RFID i wartości SAR (miara skutków termicznych oddziaływania pola elektromagnetycznego) spowodowane tą ekspozycją mogą przekraczać limity, opublikowane w zleceniach międzynarodowych lub przepisach. Nadmierna ekspozycja na pole elektromagnetyczne emitowane przez czytniki RFID UHF może dotyczyć nie tylko użytkownika urządzenia, ale również pacjenta lub osoby postronnej. Tylko ręczne czytniki RFID UHF o emisji pola elektromagnetycznego poniżej 1 W można uznać za nieistotne źródło narażenia ludzi. Korzystanie z czytników o mocy przekraczającej 1 W wymaga oceny poziomu pola elektromagnetycznego za pomocą pomiarów, a również oceny SAR za pomocą modelowania numerycznego w przypadku ich użycia w bezpośredniej bliskości ludzi. We wszystkich przypadkach niewystarczającą odporność elektromagnetyczną urządzeń elektronicznych (w tym implantów medycznych) należy rozważyć w pobliżu czytników RFID co najmniej do odległości od czytnika RFID równej połowie jego zasięgu odczytu. Zagrożenia elektromagnetyczne związane z używaniem ręcznych czytników RFID mogą być ograniczone przez odpowiednie środki ochronne, jak pokazano w tym artykule, wraz z zasadami oceny zagrożeń elektromagnetycznych in-situ w pobliżu ręcznych czytników UHF RFID.
Źródło:
Inżynier i Fizyk Medyczny; 2020, 9, 2; 133--140
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies