Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "acoustic structural control" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Active noise control with a single nonlinear control filter for a vibrating plate with multiple actuators
Autorzy:
Mazur, K.
Pawełczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/176906.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
active noise-vibration control
active structural acoustic control
adaptive control
nonlinear control
Opis:
Vibrating plates can be used in Active Noise Control (ANC) applications as active barriers or as secondary sources replacing classical loudspeakers. The system with vibrating plates, especially when nonlinear MFC actuators are used, is nonlinear. The nonlinearity in the system reduces performance of classical feedforward ANC with linear control filters systems, because they cannot cope with harmonics generated by the nonlinearity. The performance of the ANC system can be improved by using nonlinear control filters, such as Artificial Neural Networks or Volterra filters. However, when multiple actuators are mounted on a single plate, which is a common practice to provide effective control of more vibration modes, each actuator should be driven by a dedicated nonlinear control filter. This significantly increases computational complexity of the control algorithm, because adaptation of nonlinear control filters is much more computationally demanding than adaptation of linear FIR filters. This paper presents an ANC system with multiple actuators, which are driven with a single nonlinear filter. To avoid destructive interference of vibrations generated by different actuators the control signal is filtered by appropriate separate linear filters. The control system is experimentally verified and obtained results are reported.
Źródło:
Archives of Acoustics; 2013, 38, 4; 537-545
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Feed-forward compensation for nonlinearity of vibrating plate as the sound source for active noise control
Kompensacja nieliniowości płyty drgającej jako źródła dźwięku dla systemów aktywnej redukcji hałasu
Autorzy:
Mazur, K.
Pawełczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/368955.pdf
Data publikacji:
2011
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
aktywna redukcja hałasu
płyta drgająca
nieliniowe sterowanie
kompensacja
emisja dźwięku
adaptacja
ekwalizacja
active noise control
active structural acoustic control
vibrating plate
sound radiation
adaptation
feed-forward
equalization
nonlinear control
Opis:
Active Noise Control (ANC) systems are usually designed in the feed-forward structure with adaptive linear control filters. However, performance of such systems, when a vibrating plate is used as the secondary source, may be poor due to significant non-linearity of the plate response. The linear systems are then unable to cope with higher harmonics generated by the nonlinearity. One solution to this problem is to apply a nonlinear ANC algorithm. However, it adds additional complexity to this layer. It is particularly severe for multichannel systems, where the algorithms are complex by themselves, and making them nonlinear may significantly reduce their scalability. In this paper, another approach is proposed. Multiple actuators are mounted on a single plate, in order to effectively excite more vibration modes and generate a higher acoustic power, than in case of a single actuator. The response of the vibrating plate as the sound source is then linearized with a set of nonlinear finite impulse response filters, operating individually for each actuator. The Filtered-x LMS algorithm is adopted to update parameters of the nonlinear filters. The control system is experimentally verified and obtained results are reported.
Systemy aktywnej redukcji hałasu zwykle projektowane są w strukturze kompensacyjnej z adaptacyjnymi liniowymi filtrami sterującymi. Wówczas, w przypadku zastosowania płyty drgającej jako źródła dźwięku, skuteczność działania może być zmniejszona z powodu występujących nieliniowości w torze wtórnym. Liniowy układ kompensacji nie jest w stanie poradzić sobie z wyższymi harmonicznymi generowanymi przez nieliniowości. Jednym z rozwiązań jest zastosowanie nieliniowego algorytmu aktywnej redukcji hałasu. Zwiększa to jednak złożoność układu w tej warstwie sterowania. W przypadku wielokanałowych systemów aktywnej redukcji hałasu, które same w sobie są złożone, wprowadzenie nieliniowości w algorytmie znacząco zmniejsza skalowalność całego systemu. W niniejszym artykule zaproponowane jest inne podejście. Aby zapewnić efektywne pobudzenie większej liczby mod i uzyskanie większej mocy akustycznej jak w przypadku pojedynczego elementu wzbudzającego, zastosowano wiele elementów wykonawczych wzbudzających drgania. Odpowiedź płyty drgającej pełniącej rolę złożonego źródła dźwięku jest linearyzowana przez zbiór nieliniowych filtrów o skończonej odpowiedzi impulsowej działających niezależnie na poszczególne elementy wykonawcze. Do aktualizacji parametrów filtrów nieliniowych zastosowany jest algorytm Filtered-x LMS. Zaproponowany system sterowania został poddany weryfikacji eksperymentalnej, a uzyskane wyniki zostały zaprezentowane i skomentowane.
Źródło:
Mechanics and Control; 2011, 30, 3; 146-150
2083-6759
2300-7079
Pojawia się w:
Mechanics and Control
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies