Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Chromikova, J." wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
Increased Concentrations of Nitrates in Groundwater in Selected Localities of the Moravian – Silesian and Olomouc Regions in the Czech Republic
Zwiększenie stężenia azotanów w wodach gruntowych w wybranych lokalizacjach w Regionie Śląsko-Morawskim oraz Ołomunckim w Czechach
Autorzy:
Foltova, P.
Heviankova, S.
Chromikova, J.
Kasparkova, A.
Powiązania:
https://bibliotekanauki.pl/articles/318889.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
azotany
wody powierzchniowe
Region Śląsko-Morawski (Republika Czeska)
Region Ołomuniec
nitrates
groundwater
limit value
Moravian-Silesian Region
Olomouc Region
Opis:
The paper deals with the issue of nitrates in groundwater, to where they predominantly pass due to the application of nitrogen fertilizers in agricultural areas. Excess concentrations of nitrates in drinking water are undesirable, and may even cause a life-threatening condition called methemoglobinemia. The permissible concentrations of nitrates in drinking water are determined by legislation and the upper limit is 50 mg/l. Approximately 5% of the Czech population draw water from individual sources. In this study we identified and analysed selected samples from wells located in the Moravian-Silesian Region and in the Olomouc Region. The data and test results in this paper show that the nitrate concentration limit of 50 mg/l was exceeded in a half of the analysed groundwater samples. In some cases, the limit was exceeded in the order of tens of mg/l.
Źródło:
Inżynieria Mineralna; 2018, R. 19, nr 1, 1; 35-38
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electrodialysis Process to Reduce the Concentration of Nitrates in Waters
Proces elektrodializy w zastosowaniu do redukcji stężenia azotanów w wodzie
Autorzy:
Hrbacova, P.
Heviankova, S.
Chromikova, J.
Thomas, J.
Powiązania:
https://bibliotekanauki.pl/articles/319200.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
elektrodializa
azotany
model wodny
test przedziałowy
pół-test
electrodialysis
nitrates
water modelling
batch test
semi-test
Opis:
Nitrates and nitrites are natural components of the environment and contribute to the nitrogen cycle on Earth. Although nitrogen is essential for life, nitrogen compounds are among the main pollutants in the ecosystem. High concentrations of nitrogen compounds in the groundwater are primarily caused by human activity mostly in the use of chemical fertilizers in agriculture. Common health risks associated with higher concentrations of nitrates give rise to methemoglobin, which negatively affects mainly infants, and the potential formation of carcinogenic nitrosamines. This paper summarizes the results of laboratory tests of electrodialysis to remove nitrates from the model water. For the model solutions we used NaNO3 and NaNO3 with NaCl with a concentration of nitrates of approximately 1000 mg/l. The aim of the test was to achieve a concentration of nitrates corresponding to the limit for drinking water, which is 50 mg/l. The tests were carried out in the batch mode, and semi-continuous mode. All the tests have demonstrated the effectiveness of nitrate removal around 90%.
Azotany i azotyny są naturalnymi składnikami środowiska i biorą udział w obiegu azotu na Ziemi. Pomimo tego, że azot jest niezbędny do życia, związki azotu występują wśród głównych składników zanieczyszczeń w ekosystemie. Wysokie stężenia związków azotu w wodach gruntowych są spowodowane głównie działalnością ludzką poprzez stosowanie nawozów w rolnictwie. Powszechne zagrożenia zdrowia związane z wyższymi stężeniami azotanów to wzrost poziomu methemoglobiny, która negatywnie wpływa zwłaszcza na niemowlęta, jak również potencjalne tworzenie się rakotwórczych nitrozoamin. W artykule przedstawiono wyniki testów laboratoryjnych elektrodializy, przeprowadzanych w celu usunięcia azotanów z wody wzorcowej. Jako modelowe roztwory zastosowano NaNO3 oraz NaNO3 z NaCl o stężeniu azotanów na poziomie ok. 1000 mg/l. Celem testu było osiągnięcie stężenia azotanów na poziomie akceptowalnym dla wody pitnej, który wynosi 50 mg/l. Testy zostały przeprowadzone w trybie przedziałowym i pół-ciągłym. Wszystkie testy wskazały efektywność usuwania azotanów na poziomie około 90%.
Źródło:
Inżynieria Mineralna; 2017, R. 18, nr 1, 1; 125-130
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies