Wstępna analiza możliwości przeskoku liczydła mechanicznego gazomierza miechowego
Preliminary analysis of the possibility of an incorrect shift of the mechanical index of a diaphragm gas meter
Autorzy:
Lipka, Tomasz
Dudek, Adrian
Powiązania:
https://bibliotekanauki.pl/articles/31348184.pdf
Data publikacji:
2022
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
gazomierz miechowy
liczydło mechaniczne
nieprawidłowy przeskok liczydła
nielegalny pobór gazu
kradzież gazu
nierozliczone ilości gazu
ekspertyza
diaphragm gas meter
mechanical index
incorrect shift of gas meter index
illegal gas consumption
gas theft
unaccountedfor gas lost
expertise
Opis:
W artykule omówiono problematykę nielegalnego poboru gazu (ang. unaccounted for gas, UAG) w oparciu o dane literaturowe. Problematyka ta znana jest nie tylko w Polsce, ale i na całym świecie. Opisano źródło problemu przeskoków liczydeł mechanicznych zgłaszanych przez odbiorców oraz przedstawiono częściowe wyniki analizy około 1400 ekspertyz wykonywanych w ramach działalności Instytutu Nafty i Gazu – Państwowego Instytutu Badawczego. Podano krótki opis sposobu postępowania podczas wykonywania ekspertyzy mechanoskopijnej z podejrzeniem wystąpienia niekontrolowanego przeskoku wskazania liczydła mechanicznego gazomierza. Oceniano występujące luzy technologiczne pomiędzy bębenkami oraz przerzutnikami dekadowymi. W dalszej części artykułu szczegółowo opisano budowę konstrukcyjną oraz wyjaśniono zasadę działania liczydła mechanicznego zarówno ze sprzęgłem magnetycznym jak i mechanicznym. W części praktycznej zawarto opis wytypowanych próbek, na których prowadzono badanie. Poza jednym wyjątkiem były to liczydła nowe, pochodzące z demontażu z gazomierzy, ze wskazaniem początkowym bliskim lub równym 0 m3. W dalszej części zaprezentowano szczegółowy opis konstrukcji wykonanego stanowiska badawczego podzielonego na trzy moduły badawcze. Przytoczono literaturę, na podstawie której opracowywano założenia do przebiegu testów laboratoryjnych w trakcie których symulowano pracę gazomierza w okresie zimowym dla domu ogrzewanego kotłem gazowym z zasobnikiem ciepłej wody użytkowej (CWU) oraz płytą gazową przeznaczoną do przygotowywania posiłków. Cykle badawcze były tak dostosowane, aby odzwierciedlić pracę gazomierzy o wielkości G4 (zakres pomiarowy 0,04–6,0 m3 /h), które są najczęściej stosowane w gospodarstwach domowych. Testy wykonano w temperaturze pokojowej z zakresu 25°C(±5°C). Napędzanie liczydeł trwało przez 7 miesięcy przy średnim strumieniu około 4 m3/h. Zasymulowano średnie zużycie 2000 m3, co odzwierciedla pracę gazomierza przez okres około 10 lat. We wnioskach zawarto analizę otrzymanych rezultatów, z których wynika, że przeskok liczydła mechanicznego gazomierza miechowego jest możliwy, ale tylko w specyficznych warunkach trudnych do wykazania.
The article discusses the problem of illegal gas consumption – UAG (unaccounted for gas) based on literature data. This problem is known not only in Poland but also in the whole world. The source of the problem of uncorrected turn of drums of mechanical index of diaphragm gas meter reported by customers has been described and partial results of the analysis of about 1400 expert opinions carried out by the Oil and Gas Institute – National Research Institute have been presented. A brief description of how to proceed when performing mechanoscopic expertise in case of suspicion of uncorrected turn of drums of mechanical index of a gas meter has been included. The technological clearances between drums and decade converters have been assessed. In the following part of the article, the design has been described in detail and the principle of operation of the mechanical index with both magnetic and mechanical drive has been explained. In the practical part there is a description of selected samples based on which the research was conducted. With one exception these were new indices, from disassembled gas meters, with initial indication close or equal to 0 m3. In the next section a detailed of the construction of the 3 test rig has been presented. The publications based on which the assumptions were worked out for the course of laboratory tests during which the operation of the gas meter was simulated in the winter period for a house heated by a gas furnace with a hot water storage tank and a gas plate intended for preparing meals has been quoted. The test cycles were adjusted to reflect the operation of gas meters of G4 size (measuring range 0.04–6.0 m3/h), which are most commonly used in households. The tests were performed at room temperature within the range of 25 ±5°C. The driving of the index lasted for a period of 7 months with an average flow rate of about 4 m3/h. An average consumption of 2000 m3 was simulated, which reflects the operation of the gas meter for a period of about 10 years. The conclusions include an analysis of the obtained results, which shows that the uncorrected turn of drums mechanical index of diaphragm gas meter is possible, but only under specific conditions that are difficult to demonstrate.
Źródło:
Nafta-Gaz; 2022, 78, 7; 535-541
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optymalny dobór gazomierzy miechowych przez operatora systemu gazowniczego
Optimal selection of diaphragm gas meters by the operator of a gas system
Autorzy:
Matusik, J.
Jaworski, J.
Powiązania:
https://bibliotekanauki.pl/articles/1835431.pdf
Data publikacji:
2017
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
gazomierz miechowy
nierozliczone ilości gazu
parametry gazomierzy
charakterystyka metrologiczna
początkowe błędy wskazań
trwałość gazomierzy
stabilność gazomierzy
diaphragm gas meter
unsettled amounts of gas
parameters of gas meters
metrological characteristics
initial errors of indication
durability of diaphragm gas meter
gas meter stability
Opis:
W artykule omówiono wybrane charakterystyki metrologiczne gazomierzy miechowych, które w istotny sposób wpływają na ilość nierozliczonego gazu. Zaprezentowano też aplikację, która na podstawie wprowadzonych charakterystyk metrologicznych danego gazomierza pozwala oszacować skalę wyżej wymienionego zjawiska. Informacją zwrotną z aplikacji jest analiza ekonomiczna uwzględniająca koszty zakupu gazomierza oraz wielkość zysków lub strat związanych z jego funkcjonowaniem w całym okresie eksploatacji. Porównując w ten sposób kilka typów gazomierzy, kupujący (operator systemu gazowniczego) może dokonać takiego wyboru, który w bliższej lub dalszej przyszłości przełoży się na wymierne korzyści finansowe.
In the article selected metrological characteristics of diaphragm gas meters, which significantly affect the amount of unaccounted gas were discussed. An application which allows to estimate the scale of this phenomenon based on the input of metrological characteristics of the meter, has been presented in this article as well. The feedback from the application is the price balance that takes into account the cost of purchasing the gas meter and the amount of profits or losses, related to its functioning during the whole period of operation. Comparing a few groups of meters in such a way, the buyer can make a more qualified choice, which sooner or will translate into tangible financial benefits.
Źródło:
Nafta-Gaz; 2017, 73, 4; 274-286
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies