Tytuł:
Air movement characteristics inside a cow barn with natural ventilation under no-wind conditions in the winter season
Autorzy:
Herbut, P.
Powiązania:
https://bibliotekanauki.pl/articles/61769.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
air movement
cow barn
natural ventilation
no-wind condition
winter season
air circulation
barn
building
Opis:
The paper presents results of air movement observations inside a cow barn (Fermbet construction type) adapted for a loose housing system. The conducted experiments made it possible to determine directions and characteristics of ventilated air flux in selected areas of the building as well as mark out areas where air stood still. In addition, the study offers recommendations regarding effective ventilation systems in the occupied zone under no-wind conditions.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2010, 11
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ekologiczne wieżowce
Autorzy:
Błaszczyński, Tomasz Z.
Powiązania:
https://bibliotekanauki.pl/articles/129178.pdf
Data publikacji:
2019
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
budynek wysokościowy
budynek ekologiczny
wentylacja naturalna
światło dzienne
rekuperacja energii
przeszklenie inteligentne
budynek energooszczędny
high-rise building
ecological building
natural ventilation
daylight
energy recuperation
intelligent glazing
energy efficient building
Źródło:
Builder; 2019, 23, 5; 86-89
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wybranych czynników kształtujących energochłonność współczesnych budynków
Selected factors analysis of shaping energy consumption of modern buildings
Autorzy:
Pawłowski, K.
Nakielska, M.
Powiązania:
https://bibliotekanauki.pl/articles/2068091.pdf
Data publikacji:
2017
Wydawca:
Politechnika Częstochowska
Tematy:
zużycie energii w budynku
budynek energooszczędny
ściany zewnętrzne
naturalna wentylacja
energy consumption of a building
energy efficient building
external wall barriers
natural ventilation
Opis:
Energochłonność budynku określa się jako ilość energii (m.in. cieplnej, elektrycznej) dostarczonej do budynku z zewnątrz w związku z poprawną eksploatacją budynku w ciągu roku. Określana jest za pomocą różnych wskaźników wyrażonych w kWh/(m2·rok): wskaźnik energii użytkowej - EU, wskaźnik energii końcowej - EK, a w świadectwach charakterystyki energetycznej ocenia się budynki w odniesieniu do wskaźnika nieodnawialnej energii pierwotnej EP. Większość użytkowników uważa, że energochłonność zależy od systemu grzewczego, dlatego koncentrują się tylko na poszukiwaniu supernowoczesnego i taniego w eksploatacji systemu produkującego ciepło na potrzeby c.o. i c.w.u. Kształtowanie energooszczędnego budynku (o niskiej energochłonności) to złożony proces, w którym należy wziąć pod uwagę różne elementy wpływające na ilość zużytej energii. Jednocześnie obiekty budowlane należy projektować tak, aby możliwe było komfortowe użytkowanie tych budynków, zapewniając odpowiednie parametry mikroklimatu wnętrza. W pracy przedstawiono analizę wpływu parametrów fizykalnych przegród zewnętrznych i ich złączy oraz systemu wentylacji na energochłonność budynku.
Energy consumption of a building is defined as the amount of energy (e.g. thermal, electric) supplied to the building from the outside in connection with a proper building operation during a year. It is determined by means of different indicators expressed in kWh (m2 year): applied energy indicator (EU), final energy indicator (EK), and in power engineering characteristics certificates buildings are evaluated in relation to non-renewable primary energy (EP). The majority of consumers think that energy consumption depends on a heating system, therefore, they focus only on looking for a modern and low-maintenance system that produces heat for the needs of a central heating and hot service water. Shaping an energy efficient building (of low energy consumption) is a complex process, in which one is to take into consideration various elements that impact the amount of energy that has been consumed. Simultaneously, building structures should be constructed in order to utilize them comfortably by providing adequate microclimate parameters of the interior. This thesis presents an analysis of the impact of physical parameters of external wall barriers and their joints, and a ventilation system on energy consumption of a building.
Źródło:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo; 2017, 23 (173); 245-255
0860-7214
Pojawia się w:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ oporności cieplnej przegród zewnętrznych budynku na intensywność naturalnej wymiany powietrza
The influence of thermal insulation on natural air flow in buildings in the summer season
Autorzy:
Bzowska, D
Powiązania:
https://bibliotekanauki.pl/articles/362473.pdf
Data publikacji:
2011
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
wentylacja naturalna
przepływy odwrotne powietrza wentylacyjnego
opór cieplny obudowy budynku
natural ventilation
thermal resistance
building envelope
Opis:
Analizowano wpływ oporu termicznego przegród zewnętrznych na intensywność wymiany powietrza w budynkach wyposażonych w wentylację naturalną. Symulowane były kierunki przepływu powietrza przez budynek zarówno przy wietrze wspomagającym jak i przeciwnym. Przedstawiane w artykule procesy wyznaczane były dla średnich wartości temperatury i prędkości wiatru w lipcu w Warszawie.
The effects of thermal resistance of building's envelope on indoor temperature and ventilation flow rate during summer season were investigated. The examined buildings were two-zone objects with partitions made of typical material fabrics. The natural air exchange process is intensified by internal heat sources acted together with solar radiation on thermal buoyancy forces. When wind is concerned, both forms of airflow throughout the buildings were simulated - with assisting and opposing winds. The heat transfer and air exchange processes are simulated as coupled processes with the reference to the mean weather values only. Te regression model was proposed for the indoor temperature for its maximum and minimum value in both zones and for the overall air exchange rate at the assisting wind as well as at the opposing one.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2011, T. 6, nr 1, 1; 21-26
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Method for determining the ventilation air quantity in buildings for cattle on a base of CO2 concentration
Metoda okreslania ilosci powietrza wentylacyjnego w budynkach dla bydla na podstawie stezenia CO2
Autorzy:
Gluski, T.
Powiązania:
https://bibliotekanauki.pl/articles/793517.pdf
Data publikacji:
2012
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
livestock building
natural ventilation
dairy cattle
air stream
carbon dioxide concentration
indicator gas
air temperature
calculation method
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2012, 12, 2
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The optimal amount of air for the natural ventilation of classrooms as a function of the rate of outdoor air leakage from windows
Właściwa ilość powietrza dla wentylacji naturalnej sal lekcyjnych w funkcji wartości współczynnika infiltracji powietrza zewnętrznego dla okien
Autorzy:
Lis, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2067614.pdf
Data publikacji:
2020
Wydawca:
Politechnika Częstochowska
Tematy:
educational building
outdoor air leakage
air infiltration
natural ventilation
budynek edukacyjny
sala lekcyjna
szczelność okien
infiltracja powietrza
wentylacja
Opis:
In the last few years there has been a tendency towards the air-tight sealing of buildings. This phenomenon can be seen both in older buildings being refurbished, as well as in those that are new or thermally upgraded. The use of excessively air-tight windows in educational buildings with gravity (natural) ventilation system limits the inflow of external air to classrooms. The analysis covered 50 educational buildings in Częstochowa, which are used by primary and middle schools. Windows in those buildings were in a bad or very bad technical condition and their air-permeability was very high. Their defects cause excessive heat losses from heated rooms. It turns out, however, that the high air-permeability of windows (rate of outdoor air leakage (a) at the level of 6-7 m3/(hmdaPa2/3) allows for a relatively beneficial level of natural ventilation and sufficient inflow of fresh air in the absence of other inflow of outside air solutions. Unfortunately, as a result of the replacement of old windows with new ones and no changes in the existing system of natural ventilation, a considerable deterioration of microclimate in classrooms can be expected, especially due to non-compliance with the requirements related to the sufficient supply of fresh air. To prevent this, it is necessary to take action to improve existing ventilation systems.
Od kilku lat obserwuje się tendencję do uszczelniania budynków. Zjawisko to można zaobserwować zarówno w remontowanych starszych budynkach, jak i w nowych lub poddawanych termomodernizacji. Ponieważ większość budynków edukacyjnych jest wyposażona w systemy wentylacji naturalnej (grawitacyjnej), zastosowanie okien nadmiernie szczelnych znacznie ogranicza dopływ powietrza z zewnątrz do pomieszczeń. Z tego punktu widzenia zbadano kompletną statystyczną populację miejską 50 budynków edukacyjnych zlokalizowanych w Częstochowie. Okna w tych budynkach były w złym lub bardzo złym stanie technicznym, a ich przepuszczalność powietrza była bardzo wysoka. Ich wady powodują nadmierne straty ciepła z ogrzewanych pomieszczeń. Okazuje się jednak, że wysoka przepuszczalność powietrza okien (współczynnik infiltracji powietrza z zewnątrz (a) na poziomie 6-7 m3/(hmdaPa2/3) pozwala na stosunkowo prawidłowe funkcjonowanie naturalnej wentylacji i wystarczający dopływ powietrza z zewnątrz przy braku innych rozwiązań np. nawiewników. Niestety w wyniku wymiany starych okien na nowe i braku zmian w istniejącym systemie wentylacji naturalnej można spodziewać się znacznego pogorszenia mikroklimatu w salach lekcyjnych, szczególnie z powodu niespełnienia wymagań związanych z dostarczaniem dostatecznej ilości świeżego powietrza, aby temu zapobiec konieczne jest podjęcie działań modernizacyjnych instalacji wentylacyjnej.
Źródło:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo; 2020, 26 (176); 108-113
0860-7214
Pojawia się w:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przegląd przepisów i norm dotyczących projektowania wentylacji grawitacyjnej w budynkach mieszkalnych
Review of regulation and standards for design of natural ventilation in residential buildings
Autorzy:
Pykacz, S.
Powiązania:
https://bibliotekanauki.pl/articles/183149.pdf
Data publikacji:
2010
Wydawca:
Instytut Techniki Budowlanej
Tematy:
wentylacja grawitacyjna
budynek mieszkalny
projektowanie
norma polska
przepis prawny
wymagania
norma europejska
norma niemiecka
norma brytyjska
natural ventilation
residential building
designing
Polish standard
legal requirements
European standard
German standard
British standard
Opis:
Wentylacja grawitacyjna stanowi wciąż najczęściej stosowany system wentylacji w budynkach mieszkalnych w naszym kraju. Zasady jej projektowania pochodzą z lat osiemdziesiątych ubiegłego wieku i nie uwzględniają obecnego stanu wiedzy oraz sposobu wykonywania budynków mieszkalnych. W latach dziewięćdziesiątych ubiegłego stulecia wykonano duży krok w kierunku poprawy działania wentylacji grawitacyjnej, wprowadzając do praktyki budowlanej nawiewniki powietrza zewnętrznego. Jednak brak kompleksowych uregulowań w zakresie wentylacji grawitacyjnej oraz częste przypadki obchodzenia przepisów w tym zakresie nie pozwoliły na wyraźną poprawę istniejącej sytuacji. Przedstawiono analizę norm oraz przepisów krajowych i zagranicznych dotyczących wentylacji grawitacyjnej w budynkach mieszkalnych oraz analizę możliwości projektowania tej wentylacji na podstawie normowych ilości powietrza (wg stanu prawnego na dzień 31 XII 2008). Zaproponowano niezbędne zmiany w projektowaniu wentylacji grawitacyjnej budynków mieszkalnych. W artykule, który będzie opublikowany w jednym z następnych wydań kwartalnika, zostaną podane szczegółowe propozycje zmian w projektowaniu wentylacji grawitacyjnej w budynkach mieszkalnych.
Natural ventilation is still the most frequently applied system of ventilation in residential buildings in our country. Rules of its design, dating from the eighties of the last century, do not take into account present knowledge and practice for residential building construction. At the turn of the century the great progress was made for improving the performance of natural systems by implementing externally mounted air transfer devices into building practice. However, the situation was not improved sufficiently, due to the lack of comprehensive regulations in the field of natural ventilation and circumvention of regulations in frequent cases. In the current article, the analysis of Polish and foreign standards and regulations for natural ventilation in residential buildings was presented, as well as the analysis of possibilities of ventilation design based on the standardised air quantities. Necessary changes in design of natural ventilation were proposed. In the second article, which is prepared to be published in a subsequent issue, detailed proposals for changes in design of natural ventilation in residential buildings will be presented.
Źródło:
Prace Instytutu Techniki Budowlanej; 2010, R. 39, nr 1, 1; 29-51
0138-0796
Pojawia się w:
Prace Instytutu Techniki Budowlanej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical investigations of effect of indoor air quality on thermal comfort in residential buildings
Autorzy:
Krzaczek, M.
Tejchman, J
Powiązania:
https://bibliotekanauki.pl/articles/231320.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
budynek mieszkalny
jakość powietrza wewnętrznego
stężenie CO2
komfort cieplny
CFD
strefa oddychania osobista
obciążenie cieplne
wentylacja naturalna
residential building
indoor air quality
CO2 concentration
thermal comfort
personal breathing zone
heat load
natural ventilation
Opis:
The influence of the CO2 concentration in a local air zone in naturally ventilated residential houses on the residents’ behaviour was numerically investigated. A numerical two-dimensional CFD model of the indoor zone based on experiments performed by the authors was used. Different resident locations in the fluid domain and different inlet velocities imposed by wind were considered in simulations. The overall thermal comfort and IAQ indices were also calculated. The investigations results show that in contrast to the overall air quality, the local CO2 was strongly dependent upon the resident location, fresh air inlet velocity and ventilation system type.
Źródło:
Archives of Civil Engineering; 2014, 60, 1; 91-121
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies