Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "osmoza odwrocona" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Membrane processes innovation in environmental protection : review
Innowacyjne procesy membranowe w ochronie środowiska : przegląd
Autorzy:
Konieczny, Krystyna H.
Wszelaka-Rylik, Małgorzata
Macherzyński, Bartłomiej
Powiązania:
https://bibliotekanauki.pl/articles/205433.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
membrane techniques
microfiltration
ultrafiltration
nanofiltration
reverse osmosis
techniki membranowe
mikrofiltracja
ultrafiltracja
nanofiltracja
odwrócona osmoza
Opis:
The partial solution for the growing contamination of the environment is the implementation of new technologies. The most of the currently operated systems for surface and groundwaters treatment as well as for wastewater treatment characterize with complex technological arrangements based on a number of unit operations. In water-wastewater management membrane processes are more often applied, especially those in which the difference of pressure at both membrane sites is used as a driving force. As an example of such application is the use of nanofiltration for groundwaters treatment at Water Treatment Plant Zawada near Dębica or the treatment of municipal landfill leachate and industrial wastewater at Eko Dolina Waste Utilization Plant in Łężyce near Gdynia (reverse osmosis unit capacity of 120 m3/d). Municipal wastewater treatment based on membrane technologies has already been implemented at domestic wastewater treatment plant. It is especially profitable, when the load of contaminant present in a wastewater varies within a year. In the case of membrane systems use, this issue can be neglected. As an example of membrane based system may serve WWTP in Rowy n/Ustka started up in 2013 and modernized in 2017. The latest trends and developments of selected suppliers of membrane systems are also presented.
Częściowym rozwiązaniem wzrastającego zanieczyszczenia środowiska wodnego jest wdrażanie nowych technologii. Większość współczesnych dużych systemów uzdatniania wód powierzchniowych i podziemnych oraz oczyszczania ścieków charakteryzuje się bardzo złożonymi układami technologicznymi zakładającymi sekwencję wielu procesów. W gospodarce wodno-ściekowej w coraz to większym zakresie wykorzystywane są procesy membranowe, przede wszystkim te, których siłą napędową jest różnica ciśnień po obu stronach membrany. Przykładem jest między innymi zastosowanie nanofiltracji do uzdatniania wód głębinowych w SUW Zawada k. Dębicy oraz oczyszczanie odcieków z wysypisk odpadów stałych i ścieków przemysłowych technologią membranową w zakładzie Unieszkodliwiania Odpadów Eko Dolina w Łężycach k/Gdyni (wydajność RO 120 m3/dobę). Oczyszczanie ścieków komunalnych w oparciu o technologie membranowe zostało już wdrożone w krajowych oczyszczalniach ścieków. Jest to szczególnie opłacalne, gdy ładunek zanieczyszczeń obecnych w ściekach waha się w ciągu roku. W przypadku zastosowania systemów membranowych, problem ten można pominąć. Przykładem wdrożenia systemu membranowego może być WWTP w Rowach k/Ustki, którą zbudowano w 2013 r. i zmodernizowano w 2017 r. Ponadto przedstawiono najnowsze rozwiązania oraz trendy rozwoju w niektórych firmach realizujących technologie membranowe u klientów.
Źródło:
Archives of Environmental Protection; 2019, 45, 4; 20-29
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary studies for the desalination of model solution of flowback water from shale gas production in the NF/RO pilot plant
Badania nad możliwością odsalania modelowego roztworu płynu powrotnego ze szczelinowania hydraulicznego złóż gazu łupkowego w pilotowej instalacji NF/RO
Autorzy:
Rajewski, J.
Kowalik-Klimczak, A.
Szwast, M.
Gierycz, P.
Powiązania:
https://bibliotekanauki.pl/articles/257475.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
nanofiltration
NF
reverse osmosis
RO
desalination
flowback water
shale gas
nanofiltracja
odwrócona osmoza
odsalanie
płyn powrotny
gaz łupkowy
Opis:
The impact of selected process parameters of an integrated NF/RO system on possibilities of the desalination of model solutions, containing salts in typical concentrations for flowback water from shale gas production, was analyzed in this work. Based on the results of studies carried out in the pilot scale, it was found that the integrated NF/RO system allows for satisfactory reduction of the model solution of flowback water mineralization. It can be stated that the use of NF/RO system enables the re-use of the “real” flowback water during hydraulic fracturing.
W pracy zbadano wpływ wybranych parametrów procesowych zintegrowanego systemu NF/RO na możliwość odsalania modelowych roztworów zawierających sole w stężeniach charakterystycznych dla płynu powrotnego ze szczelinowania złóż gazu z łupków. Na podstawie otrzymanych wyników badań prowadzonych w skali pilotowej, stwierdzono, że zintegrowany układ NF/RO pozwala na zadowalające zmniejszenie mineralizacji roztworu modelowego płynu powrotnego. Można zatem założyć, iż zastosowanie układu NF/RO umożliwi ponowne wykorzystanie ścieku rzeczywistego podczas szczelinowania hydraulicznego.
Źródło:
Problemy Eksploatacji; 2016, 3; 155-164
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usuwanie mikrozanieczyszczeń estrogenicznych z roztworów wodnych w wysokociśnieniowych procesach membranowych
Removal of estrogenic micropollutants from water solutions by high-pressure driven membrane processes
Autorzy:
Dudziak, M.
Bodzek, M.
Powiązania:
https://bibliotekanauki.pl/articles/236718.pdf
Data publikacji:
2009
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
mikrozanieczyszczenia estrogeniczne
kwasy humusowe
filtracja membranowa
odwrócona osmoza
nanofiltracja
układ filtracji
estrogenic micropollutants
humic acids
membrane filtration
reverse osmosis
nanofiltration
filtration mode
Opis:
Filtracji osmotycznej i nanofiltracyjnej poddano modelowe roztwory wodne zawierające osiem wybranych związków z grupy fitoestrogenów i ksenoestrogenów. Badano wpływ procesu membranowego i układu filtracji na skuteczność usuwania mikrozanieczyszczeń. Dokonano analizy współczynnika retencji mikrozanieczyszczeń estrogenicznych w zależności od rodzaju filtracji, tj. w układzie filtracji jednokierunkowej (dead-end) oraz w układzie skrośnym (cross-flow), a także warunków operacyjnych filtracji (temperatura, ciśnienie transmembranowe i liniowa prędkość przepływu nadawy) i składu modelowego roztworu wodnego. Wykazano, że w układzie filtracji jednokierunkowej większy stopień usunięcia mikrozanieczyszczeń uzyskano podczas odwróconej osmozy niż nanofiltracji. Jednakże proces nanofiltracji prowadzony w układzie skrośnym także umożliwił skuteczne usunięcie badanych związków. W tym układzie filtracji retencja mikrozanieczyszczeń malała wraz ze wzrostem temperatury i ciśnienia transmembranowego, z jednoczesnym zwiększeniem wydajności membrany. Z kolei wzrost liniowej prędkości nadawy powodował również wzrost współczynnika retencji mikrozanieczyszczeń. Zwiększenie retencji badanych mikrozanieczyszczeń stwierdzono również w warunkach występowania zjawiska blokowania membrany wywołanego obecnością w wodzie kwasu humusowego.
Model water solutions containing eight compounds chosen from the group of phytoestrogens and xenoestrogens were made subject to reverse osmosis and nanofiltration with the aim of examining how the membrane process and the filtration mode influence the removal of the micropollutants. The retention coefficients for the estrogenic micropollutants were related to the filtration mode (dead-end, cross-flow), the operating parameters of filtration (temperature, transmembrane pressure, linear velocity of feed flow), and the com-position of the model solution. It has been demonstrated that the dead-end mode produced higher removal efficiencies during reverse osmosis than during nanofiltration. However, con-ducted in the cross-flow mode, nanofiltration also enabled efficient removal of the micro-pollutants examined. In the cross-flow mode, the retention of the micropollutants decreased with the rise in temperature and transmembrane pressure, and there was a concomitant increase in the performance of the membrane. The rise in the linear velocity of the feed flow was found to be a factor contributing to the increase in the retention coefficient. An increase in the retention coefficient was also observed under conditions of membrane fouling caused by the presence of humic acid in the water.
Źródło:
Ochrona Środowiska; 2009, 31, 3; 33-36
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of membrane techniques for municipal wastewater treatment and reuse
Zastosowanie technik membranowyoh do odzyszozania ścieków i ich ponownego wykorzystania
Autorzy:
Pervov, A.
Spitsov, D.
Powiązania:
https://bibliotekanauki.pl/articles/400277.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ścieki bytowe
osad ściekowy
nanofiltracja
odwrócona osmoza
odzysk
regeneracja
membrane fouling
nanofiltration
open-channel module
reclamation
recovery
reverse osmosis
sludge dewatering
spiral wound module
domestic wastewater
Opis:
State-of-the-art chemical, physical and biological water treatment techniques do not always properly remove some biogenic elements (nitrates, ammonia and phosphates) to reuse or reclaim wastewater. Modern membrane techniques provide high efficiency in removal of suspended and colloidal matter, bacteria and viruses, organic compounds as well as dissolved ions. For wastewater reuse and reclamation application of reverse osmosis provides reduction of BOD, phosphates and ammonia without application of biological treatment. To successfully apply reverse osmosis to treat wastewater, adequate pretreatment is required. Often pretreatment costs even exceed reverse osmosis facilities costs. Long research in fouling and scaling mechanisms revealed that fouling rates are dependent not only on hydrodynamic factors, but on membrane properties and channel configuration as well. Therefore, development of a new type of membrane channel with improved hydraulic and fouling characteristics enabled us to present efficient water treatment techniques for wastewater treatment and reclamation. Schematic flow diagrams are presented for different wastewater treatment cases, such as car washing and laundry effluent as well as domestic wastewater treatment and reuse.
Dostępne techniki chemicznego, fizycznego i biologicznego oczyszczania nie zawsze są w stanie efektywnie usuwać związki biogenne (azotany, azot amonowy, fosforany) w celu ponownego użycia oczyszczonych ścieków. Nowoczesne techniki membranowe zapewniają wysoką efektywność usuwania zawiesiny rozpuszczonej i koloidalnej, bakterii, wirusów, związków organicznych i rozpuszczonych jonów. Zastosowanie techniki membranowej w celu odzysku wody ze ścieków nie wymaga stosowania biologicznego oczyszczania ścieków. Efektywne zastosowanie procesów membranowych wymaga wstępnego oczyszczania ścieków, którego koszty mogą przewyższać te związane z eksploatacją membran.
Źródło:
Inżynieria Ekologiczna; 2011, 24; 107-119
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of membranes to treat natural and waste waters: new considerations to reduce fouling and increase recovery Up to 99%
Zastosowanie membran do oczyszczania wody i ścieków: nowe aspekty zmniejszenia zanieczyszczenia i zwiększenia odzysku do 99%
Autorzy:
Pervov, A.
Andrianov, A.
Gorbunova, T.
Powiązania:
https://bibliotekanauki.pl/articles/400299.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ścieki bytowe
nanofiltracja
odwrócona osmoza
odzysk
regeneracja
domestic wastewater
fouling-free technologies
membrane fouling
nanofiltration
natural water treatment
open-channel module
reclamation
recovery
reverse osmosis
scaling
spiral wound module
urban surface water
zero discharge
Opis:
Survey shows that high operational costs of membrane facilities and large amounts of effluents are mainly attributed to fouling and scaling. Research of scaling and fouling mechanisms showed that these processes depend not only on hydraulic and hydrodynamic factors, but on membrane type, material and channel configuration as well. Operational parameters of different membrane configurations show that spiral wound modules demonstrate best hydraulic and hydrodynamic characteristics combined with lowest price. Main ways to develop new fouling-free techniques are outlined that require modified "open-chan-nel" spiral wound membranes. Elimination of "deadlocks" as a main cause of scaling and fouling provide new technological approach to develop water treatment techniques without pretreatment facilities and chemicals. Modification of channel provides possibility to reach high recoveries and high supersaturation values due to strong stability of calcium carbonate solutions. Membrane transport is not only purification instrument it is also a reactor to coagulate, concentrate and precipitate water constituents on membrane surface. Several examples of water treatment flow diagrams are presented to demonstrate principles of zero concentrate flow discharge. Coagulated suspended matter after membrane flushes is collected, sedimented and finally dewatered. The dewatered sludge contains averagely 0,8 per cent of initial water. Due to the use of an "open-channel" modules membrane brine flow could be concentrated by many times without a fear of scaling and added to the sludge. Thus the excessive salts and impurities could be withdrawn from water systems together with partially dewatered sludge. Similarly excessive calcium carbonate could be also concentrated in membrane modules and subsequently precipitated, sedimented and dewatered. Solution of fouling problems thus provides a new approach to save operational costs and to increase ecological efficiency of membrane water treatment tools.
Badania wykazują, iż wysokie koszty eksploatacji urządzeń z zastosowaniem membran i duże ilości odcieków są przypisywane zanieczyszczeniom i odkładaniu się kamienia. Procesy te zależą nie tylko od czynników hydraulicznych i hydrodynamicznych, ale także od rodzaju membran i materiałów użytych do ich budowy. Parametry pracy różnych membran wykazały najlepsze właściwości modułów spiralnych przy najniższej cenie. Przepływ przez membrany nie ogranicza się jedynie do oczyszczania, jest to także reaktor do koagulacji, zatężania i strącania. Zawiesina po procesie koagulacji z procesu czyszczenia membran jest poddana sedymentacji i odwadnianiu. Osad z odwadniania zawiera około 8% wody. Zastosowanie modułów o "otwartych kanałach" powoduje zmniejszenie zagrożenia zanieczyszczenia i odkładania się kamienia. Rozwiązanie problemu zmniejszenia zanieczyszczenia membran pozwoli zmniejszyć koszty pracy instalacji i spowoduje wyższy poziom ekologicznej efektywności narzędzi wykorzystujących technikę membranową.
Źródło:
Inżynieria Ekologiczna; 2011, 24; 17-31
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies