Tytuł:
Evaluation of Sound Exposure and Risk of Hearing Impairment in Orchestral Musicians
Autorzy:
Pawlaczyk-Łuszczyńska, M.
Dudarewicz, A.
Zamojska, M.
Śliwinska-Kowalska, M.
Powiązania:
https://bibliotekanauki.pl/articles/90038.pdf
Data publikacji:
2011
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
musicians
exposure to orchestral noise
risk of noise-induced hearing loss
Opis:
This study aimed to assess exposure to sound and the risk of noise-induced hearing loss (NIHL) in orchestral musicians. Sound pressure level was measured in 1 opera and 3 symphony orchestras; questionnaires were filled in. On the basis of that data, the risk of NIHL was assessed according to Standard No. ISO 1999:1990. Classical orchestral musicians are usually exposed to sound at equivalent continuous A-weighted sound pressure levels of 81−90 dB (10th−90th percentiles), for 20−45 h (10th−90th percentiles) per week. Occupational exposure to such sound levels over 40 years of employment might cause hearing loss (expressed as a mean hearing threshold level at 2, 3, 4 kHz exceeding 35 dB) of up to 26%. Playing the horn, trumpet, tuba and percussion carries the highest risk (over 20%).
Źródło:
International Journal of Occupational Safety and Ergonomics; 2011, 17, 3; 255-269
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hearing Ability in Orchestral Musicians
Autorzy:
Pawlaczyk-Łuszczyńska, M.
Dudarewicz, A.
Zamojska, M.
Śliwińska-Kowalska, M.
Powiązania:
https://bibliotekanauki.pl/articles/177978.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
musicians
exposure to orchestral noise
hearing impairment
pure-tone audiometry
transient-evoked otoacoustic emissions
Opis:
Pure-tone audiometry (PTA) and transient-evoked otoacoustic emissions (TEOAEs) were determined in 57 classical orchestral musicians along with a questionnaire inquiry using a modified Amsterdam Inventory for Auditory Disability and Handicap ((m)AIADH). Data on musicians’ working experience and sound pressure levels produced by various groups of instruments were also collected. Measured hearing threshold levels (HTLs) were compared with the theoretical predictions calculated according to ISO 1999:1990. High frequency notched audiograms typical for noise-induced hearing loss were found in 28% of the subjects. PTA and TEOAE consistently showed a tendency toward better hearing in females vs. males, younger vs. older subjects, and lower- vs. higher-exposed to orchestral noise subjects. Audiometric HTLs were better than theoretical predictions in the frequency range of 2000–4000 Hz. The (m)AIADH scores indicated some hearing difficulties in relation to intelligibility in noisy environment in 26% of the players. Our results indicated a need to implement a hearing conservation program for this professional group.
Źródło:
Archives of Acoustics; 2010, 35, 4; 579-594
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies