Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "municipal solid waste" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
The concept of land use development of a municipal solid waste landfill: the Cegłów commune case study
Autorzy:
Kwiatkowska-Malina, J.
Dybowska, S.
Powiązania:
https://bibliotekanauki.pl/articles/101195.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
land use development
municipal solid waste landfill
reclamation
recreation
Opis:
The presence of municipal solid waste landfills is an inevitable spatial phenomenon that expresses the planning properties of the process of land use, economic development and the relationship to the environment. The process of land use is continuous, in which a period of planning, development and management of its operation is followed by a period of decline in the performance of (aging) and the fall of the land. Closing the landfill and reclamation results in the appearance of problem areas, i.e. of degraded areas both on the site and in the area of its influence. The paper presents the concept of development of a closed municipal solid waste landfill in the village Woźbin in the commune Cegłów and adjacent areas. According to the ‘Project of closure and reclamation of municipal solid waste landfill in the village Woźbin, in the commune Cegłów’ after the operation of the landfill as well as the technical and biological reclamation, can be implemented forest restoration direction. The concept of developing the reclaimed municipal landfill and the adjacent land is assumed to introduce the planned forest reclamation and complement the recreational function which will increase the attractiveness of the area and will enable its use in a more economical way aimed at integrating the municipal solid waste site with its surroundings.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, IV/1; 1229-1241
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Emission Assessment at the Štěpánovice Municipal Solid Waste Landfill Focusing on Ch4 Emissions
Autorzy:
Adamcová, D.
Vaverková, M.
Břoušková, E.
Powiązania:
https://bibliotekanauki.pl/articles/123605.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
municipal solid waste landfill
landfill gas
Integrated Register of Pollutants
waste
Opis:
The study was conducted to measure the emission from landfill in the years 2005– 2011. The results are used to diagnose the emissions of CH4. The mean value of CH4 in vol. % in the collection wells ranged from 0 to 2.14 vol. % the mean concentration of CH4 in mg/m3 ranged from 0 to 25 251 mg/m3, the average concentration of CH4 in mg/Nm3 at the measuring and control points ranged from 2.2 to 24.1 mg/Nm3. CH4 emissions from the landfill do not exceed the reporting thresholds the landfill does not meet conditions for being included in the Integrated Register of Pollutants.
Źródło:
Journal of Ecological Engineering; 2016, 17, 3; 9-17
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of landfill leachate pollution: findings from a monitoring study at municipal waste landfill
Autorzy:
Vaverková, M. D.
Adamcová, D.
Powiązania:
https://bibliotekanauki.pl/articles/125392.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
groundwater monitoring
leachate monitoring
municipal solid waste landfill
surface water
water monitoring
Opis:
The monitoring that was carried out at the landfill specialized in leachate, groundwater and surface water. There were 6 sampling sites. The observed parameters were pH, BOD5, CODCr, conductivity. Leachate reached the high values in all observed parameters. Groundwater samples were collected at two monitoring wells and the sampling site (A, B, C). Surface water was collected from two sampling sites (D, E). The pH showed slightly acid values at all sampling points. The pH of surface water was slightly acid to neutral. Both BOD5 and CODCr values remained stable over the reporting period. The average conductivity value at sampling points D, E remained constant. In line with the Czech National Standard ČSN 75 7221 “Classification of Surface Water Quality” sampling point D belongs to II Water Quality Class – slightly polluted water and sampling site E to Class I water quality – unpolluted water. The authors believe that the fluctuations occurring with regard to the values of certain samples were not caused by the operation of the landfill itself, but were a result of the intense agricultural activity nearby the landfill.
Źródło:
Journal of Ecological Engineering; 2015, 16, 2; 19-32
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Redukcja emisji metanu i węglowodorów aromatycznych ze składowisk odpadów w biofiltrze – badania polowe
Minimization of Methane and Selected Aromatic Hydrocarbons Emissions from Municipal Landfill in Biofilters – a Field Study
Autorzy:
Zdeb, M.
Powiązania:
https://bibliotekanauki.pl/articles/1818583.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
biofiltracja
BTEX
metan
składowiska odpadów
biofiltration
BTEXs
methane
municipal solid waste landfill
Opis:
Discussion on counteracting the greenhouse effect focused on the reduction of CO2 emissions mainly from the fossil fuel burning. There is often forgotten that the important role in greenhouse effect play other gases, such as methane, but its production is weakly associated with the combustion of fossil fuels. The global warming potential for methane is approx. 25-fold higher than that of CO2.Methane is located at second place on the list of the substances responsible for rising the temperature of the Earth’ atmosphere. Taking into account the global action towards prevention the climate changes, a reduction of methane emissions should be enhanced. It could significantly improve the atmospheric air quality. The aim of the study was to evaluate the efficiency of bio-oxidation of methane and selected aromatic hydrocarbons emitted from municipal solid waste landfills. The research was carried out under field scale for 10 months, from early summer to early spring. An open type biofilter worked at variable loading rate of landfill gas and under different climatic conditions. Due to the low gas pressure inside the waste body, the gas suction was applied to provide a continuous gas flow to the biofilter. This was resulted in landfill gas dilution by atmospheric air migrating through the leakiness in the gas supply system. The study showed that the temperature was limiting factor in the processes of bio-oxidation of methane and monoaromatic hydrocarbons such as BTEXs in field scale biofilter. During winter season the realbed temperature fall below 0°C throughout the whole profile of the biofilter. This led to the freezing of the water contained in the soil pores, which prevented the flow of gas along the biofilter. In other seasons, where the average bed temperature ranged from 5.5 to 42.3°C, biofilter worked reaching the 100% efficiency of BTEXs removal, at average mass loading rate of 26.75 ug BTEXs m-2d-1, and 42% efficiency of methane removal at average mass loading rate of 14.6 g CH4 m-2d-1. High efficiencies of volatile organic compounds (VOCs) removal from landfill gas can be explained by dilution of gas stream entering the biofilter with the atmospheric air. Calculation of elimination capacity of particular VOCs and the evaluation of the impact of VOCs concentration on removal efficiencies was impossible due to their total oxidation in the biofilter.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 2; 1053-1073
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiany zanieczyszczenia chemicznego i mikrobiologicznego na nasionach bobiku uprawianego wokół składowiska odpadów komunalnych
Changes in chemical and microbiological contamination of horse bean seeds in the vicinity of municipal solid waste landfill
Autorzy:
Frączek, K.
Ropek, D.
Bulski, K.
Powiązania:
https://bibliotekanauki.pl/articles/337915.pdf
Data publikacji:
2017
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
bobik
mikroorganizmy
pierwiastki
składowisko komunalne
elements
horse bean
microorganisms
municipal solid waste landfill
Opis:
Celem niniejszej pracy była analiza składu pierwiastkowego zanieczyszczeń chemicznych i mikrobiologicznych występujących na nasionach bobiku uprawianego w bezpośrednim otoczeniu składowiska odpadów komunalnych. Skład pierwiastkowy zanieczyszczeń chemicznych na powierzchni badanych nasion oraz w glebie analizowano metodą EDS za pomocą mikroskopu elektronowego NOVA NANO SEM s 300. Analizy mikrobiologiczne przeprowadzono metodą seryjnych rozcieńczeń. Wyniki przeprowadzonych analiz wykazały na powierzchni nasion bobiku uprawianego na obszarze i w bezpośrednim otoczeniu składowiska komunalnego obecność zarówno makro- i mikroelementów, jak i pierwiastków z grupy metali ciężkich, a także występowanie bakterii i grzybów. Wykazano, że usytuowanie poletka względem składowiska miało istotny wpływ na stwierdzone na powierzchni nasion bobiku zanieczyszczenia chemiczne i mikrobiologiczne.
The aim of the work was to evaluate the effect of municipal solid waste landfill on the chemical and microbiological contaminants present on seeds surface of horse bean grown in its vicinity. Elemental composition of chemical contaminants on the seeds surface and in the soil was analyzed with the electron microscopy NOVA NANO SEM s 300 with EDS technique. Microbiological analyzes were performed by serial dilutions. Conducted analyses revealed presence of macro and trace elements, including heavy metals, as well as the presence of bacteria and fungi on the surface of faba bean seeds grown in the area of landfill and in its immediate vicinity. It has been shown that the localization of plot to the landfill had a significant effect on chemical and microbiological contaminants identified on the seed surface of horse bean.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2017, 17, 3; 29-40
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rascet parametrov podaci ognetushashchich veshchestv distancionno-upravljaemykh sredstv dlja tushenija poligona tverdykh bytovykh otkhudov
Calculation parameters of the remote‑controlled extinguishing device for landfill fires
Obliczanie parametrów zdalnie sterowanych urządzeń stosowanych do gaszenia pożarów na wysypiskach twardych odpadów komunalnych
Autorzy:
Loyk, V.B.
Lazarenko, А.V.
Powiązania:
https://bibliotekanauki.pl/articles/136431.pdf
Data publikacji:
2016
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
fire
hydraulic calculation
deluge sprinkler
municipal solid waste landfill
fire extinguishing
pożar
obliczenia hydrauliczne
potop tryskaczowy
wysypisko odpadów komunalnych
gaszenie pożaru
Opis:
The use of a remotely controlled sprinkler device, “deluge sprinkler” installation to extinguish fire at landfills of solid waste has been proposed in the article. According to the project the use of such remote controlled installations require laws with basic tactical and technical data. The scheme of the system and the results of hydraulic calculations to the project of the extinguishing device have been proposed. On the basis of these calculations required minimum pressure and water flow rate for the designed extinguishing system have been specified.
W artykule opisano zastosowanie zdalnie sterowanych urządzeń typu zraszacze (instalacji „potopu tryskaczowego”) do gaszenia pożaru na wysypiskach twardych odpadów komunalnych. Stosowanie takich instalacji wymaga odpowiednich przepisów prawnych, przy tworzeniu których należy brać pod uwagę podstawowe dane taktyczne i techniczne urządzeń. Przedstawiony w artykule schemat układu jest wynikiem przeprowadzonych obliczeń hydraulicznych potrzebnych do zaprojektowania takiego urządzenia gaśniczego. Na podstawie tych obliczeń określono wymagane minimalne ciśnienie i prędkość przepływu wody, jakie jest wymagane dla projektowanego systemu gaśniczego.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2016, 4, 60; 79-93
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies